首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel analytical protocol for the determination of free fatty acids (FFAs; saturated, monounsaturated and polyunsaturated) in shellfish using electrospray ionisation and liquid chromatography-mass spectrometry (LC-MS) is described. Total lipids were extracted from four commercially important shellfish species using chloroform-methanol in a modification of the traditionally used Bligh and Dyer method. FFAs were recovered from lipidic shellfish extracts by solid-phase extraction (SPE) on an aminopropyl-silica column using a 98:2 v/v diethyl ether (DEE)-acetic acid solution. Ether extracts containing the FFAs were evaporated and reconstituted in 70:30 v/v methanol-chloroform before analysis by LC-MS. The limits of quantification (LOQs) of the method ranged from 60 to 560 microgg(-1) wet weight depending on the different FFAs determined with selected ion monitoring (SIM). Results demonstrate that LC-MS is well suited for identification and quantification of FFAs in shellfish and negates the use of sample derivatisation required in gas chromatographic analysis.  相似文献   

2.
A specific, sensitive, precise, and accurate method for the determination of abscisic acid (ABA) in grapevine leaf tissues is described. The method employs high-performance liquid chromatography and electrospray ionization–mass spectrometry (LC-ESI-MS) in selected ion monitoring mode (SIM) to analyze ABA using a stable isotope-labeled ABA as an internal standard. Absolute recoveries ranged from 72% to 79% using methanol/water pH 5.5 (50:50 v/v) as an extraction solvent. The best efficiency was obtained when the chromatographic separation was carried out by using a porous graphitic carbon (PGC) column. The statistical evaluation of the method was satisfactory in the work range. A relative standard deviation (RDS) of < 5.5% and < 6.0% was obtained for intra-batch and inter-batch comparisons, respectively. As for accuracy, the relative error (%Er) was between −2.7 and 4.3%, and the relative recovery ranged from 95% to 107%.  相似文献   

3.
《Analytical letters》2012,45(7):1393-1399
Abstract

A gas chromatographic‐mass spectrometric (GC‐MS) method for the determination of methadone, heroin, cocaine, and their metabolites in urine using Selected Ion Monitoring (SIM) was developed. Following a liquid‐liquid extraction with Toxitubes A® and using their deuterated analogs as internal standards, the analytes were derivatized with 99:1 (v/v) N,O‐bis‐trimethylsilyl‐trifluoroacetamide/trimethylchlorosilane and injected by hand, in the splitless mode, at 240°C and a purging time of 0.75 min. The mass selective detector was kept at 300°C and molecules were ionized in the electron impact mode, using an energy of 70 eV. The detector response was linear for all drugs studied over the range 50–1000 ng/mL.  相似文献   

4.
In reversed-phase liquid chromatography (RPLC), the comparison of experimental results obtained from different columns is a complex problem. A correspondence factor analysis (CFA) and a linear solvation energy relationship (LSER) were applied on retention data to characterize second-order intermolecular interactions responsible for retention on a set of RPLC columns. Seven octadecyl-C18 columns with different packing materials are obtained from different manufacturers and one octyl-C8 column. The retention data were determined under isocratic conditions using a methanol–water (65:35, v/v) mobile phase. The chromatographic retention indices based on alkan-2-ones and alkyl aryl ketones retention index scales are calculated using a multiparametric least-squares regressions iterative method. The CFA and LSER results permitted to highlight that the retention indices were appropriate for studying the second-order retention mechanisms on the eight chromatographic systems investigated and exhibited the best reproducibility. Although many earlier studies have reported the use of chemometric methods to characterize chemical factors affecting retention in RPLC using retention factors as retention parameters, this is the first study based on retention indices.  相似文献   

5.
Adsorption characteristics were studied in a reversed-phase liquid chromatography consisting of an octadecylsilyl (ODS)-silica gel and ethanol/water mixture (70/30, v/v), and were compared with corresponding results obtained by using methanol/water and acetonitrile/water mixtures (70/30, v/v) as mobile phase. Similar tendencies were observed for some adsorption characteristics in the three chromatographic systems. However, the magnitude of the characteristics was not entirely identical in the three systems. Surface diffusion was dominant for intraparticle diffusion in the ODS-silica gel particles irrespective of the type of the organic modifiers in mobile phases. A few correlations were confirmed with regard to surface diffusion, i.e., an enthalpy-entropy compensation and a linear free-energy relation. The analogous correlations on surface diffusion phenomena suggest the similarity in the mechanism of surface diffusion in the three chromatographic systems.  相似文献   

6.
Second derivative-spectrophotometric and high-performance liquid chromatographic methods for the determination of prednisolone in pharmaceutical formulations have been developed. Determination of prednisolone in tablets was conducted by using a second-order derivative UV spectrophotometric method at 250 nm (n = 5). Standards for the calibration graph ranging from 5.0 to 35.0 microg/ml were prepared from stock solution. The proposed method was accurate, with 98% recovery value, and precise, with a coefficient of variation (CV) of 1.38. These results were compared with those obtained by an exclusively developed isocratic reversed-phase high-performance liquid chromatography (HPLC) method. An isocratic reversed-phase Bondapak C(18) column with acetonitrile-citrophosphate buffer (pH 5; 45:55 v/v) mobile phase was used and UV detector was set to 241 nm using 11 alpha-hydroxyprogesterone as an internal standard. Calibration solutions used in HPLC were in the range from 2 to 300 microg/ml. Results obtained by derivative UV spectrophotometric method were comparable to those obtained by HPLC method, as far as analysis of variance (ANOVA) test, F(calculated), 0.762 and F(theoretical), 3.89, results were concerned.  相似文献   

7.
A selective and sensitive reversed-phase (RP) high-performance liquid chromatographic method is developed for the quantitative analysis of five naturally occurring flavonoids of Blumea balsamifera DC, namely dihydroquercetin-7,4'-dimethyl ether (DQDE), blumeatin (BL), quercetin (QN), 5,7,3',5'-tetrahydroxyflavanone (THFE), and dihydroquercetin-4'-methyl ether (DQME). These compounds have been isolated using various chromatographic methods. The five compounds are completely separated within 35 min using an RP C18, Nucleosil column and with an isocratic methanol-0.5% phosphoric acid (50:50, v/v) mobile phase at the flow rate of 0.9 mL/min. The separation of the compounds is monitored at 285 nm using UV detection. Identifications of specific flavonoids are made by comparing their retention times with those of the standards. Reproducibility of the method is good, with coefficients of variation of 1.48% for DQME, 2.25% for THFE, 2.31% for QN, 2.23% for DQDE, and 1.51% for BL. The average recoveries of pure flavonoids upon addition to lyophilized powder and subsequent extraction are 99.8% for DQME, 99.9% for THFE, 100.0% for BL, 100.6% for DQDE, and 97.4% for QN.  相似文献   

8.
A new, simple, precise and rapid high performance liquid chromatographic method was developed for the determination of meropenem in human serum, urine and pharmaceutical dosage forms. Chromatography was carried out on an LC(18) column using a mixture of 15 mM KH(2)PO(4):acetonitrile:methanol (84:12:4; v/v/v), adjusted to pH 2.8 with H(3)PO(4). The proposed method was conducted using a reversed-phase technique, UV monitoring at 307.6 nm and cefepime as an internal standard. The retention times were 5.98 and 7.47 min for cefepime and meropenem, respectively. The detector response was linear over the concentration range of 50-10,000 ng/mL. The detection limit of the procedure was found to be 22 ng/mL. The detection limit for meropenem in human plasma was 108.4 ng/mL and the corresponding value in human urine was 179.3 ng/mL. No interference from endogenous substances in human serum, urine and pharmaceutical preparation was observed. The proposed method is sufficiently sensitive for determination of the concentrations of meropenem and may have clinical application for its monitoring in patients receiving the drug.  相似文献   

9.
高效液相色谱-串联质谱法测定葡萄中的吡效隆和赤霉素   总被引:3,自引:0,他引:3  
Zhang J  Du P 《色谱》2011,29(11):1133-1136
采用高效液相色谱-串联质谱法(HPLC-MS/MS)建立了葡萄果实中吡效隆(CPPU)和赤霉素(GA3)两种植物生长调节剂残留量的定性定量分析方法。样品用0.5%甲酸水溶液和乙腈(体积比4:1)混合溶剂提取,经Strata-X固相萃取净化,使用Agilent SB-C18 色谱柱(50mm×2.1mm,1.8μm),以0.5%甲酸水溶液-乙腈为流动相,流量0.3mL/min,采用电喷雾离子化源(ESI)多反应监测(MRM)模式下HPLC-MS/MS检测。在最佳检测条件下,得到吡效隆和赤霉素在2.0~100.0μg/L检测范围内线性关系良好,相关系数大于0.999;检出限(LOD)分别为0.3μg/L、0.5μg/L,定量限(LOQ)分别为1.0μg/L、2.0μg/L,回收率和精密度均能达到要求,表明该法准确,可用于葡萄中吡效隆和赤霉素残留量测定。  相似文献   

10.
A simple, precise, and rapid stability-indicating reversed-phase column liquid chromatographic (RP-LC) method has been developed and subsequently validated for simultaneous estimation of simvastatin (SIM) and ezetimibe (EZE) from their combination drug product. The proposed RP-LC method utilizes a LiChrospher 100 C18, 5 microm, 250 x 4.0 mm id column at ambient temperature; optimum mobile phase consisting of acetonitrile-water-methanol (60 + 25 + 15, v/v/v) with apparent pH adjusted to 4.0 +/- 0.1; mobile phase flow rate of 1.5 mL/min; and ultraviolet detection at 238 nm. SIM, EZE, and their combination drug product were exposed to thermal, photolytic, hydrolytic, and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. There were no other coeluting, interfering peaks from excipients, impurities, or degradation products due to variable stress conditions, and the method is specific for the estimation of SIM and EZE in the presence of degradation products. The described method was linear over the range of 1-80 and 3-80 microg/mL for SIM and EZE, respectively. The mean recoveries were 99.17 and 100.43% for SIM and EZE, respectively. The intermediate precision data were obtained under different experimental conditions, and the calculated value of the coefficient of variation was found to be less than the critical value. The proposed method can be useful in the quality control of bulk manufacturing and pharmaceutical dosage forms.  相似文献   

11.
Kahle KA  Foley JP 《Electrophoresis》2007,28(11):1723-1734
The first simultaneous use of a chiral surfactant and a chiral oil for microemulsion EKC (MEEKC) is reported. Six stereochemical combinations of dodecoxycarbonylvaline (DDCV: R, S, or racemic, 2.00% w/v), racemic 2-hexanol (1.65% v/v), and dibutyl tartrate (D, L, or racemic, 1.23% v/v) were examined as chiral pseudostationary phases (PSPs) for the separation of six pairs of pharmaceutical enantiomers: pseudoephedrine, ephedrine, N-methyl ephedrine, metoprolol, synephrine, and atenolol. Subtle differences were observed for three chromatographic figures of merit (alpha(enant), alpha(meth), k) among the chiral microemulsions; a moderate difference was observed for efficiency (N) and elution range. Dual-chirality microemulsions provided both the largest and smallest enantioselectivities, due to small positive and negative synergies between the chiral microemulsion components. For the ephedrine family of compounds, dual-chiral microemulsions with surfactant and oil in opposite stereochemical configurations provided higher enantioselectivities than the single-chiral component microemulsion (RXX), whereas dual-chiral microemulsions with surfactant and oil in the same stereochemical configurations provided lower enantioselectivities than RXX. Slight to moderate enantioselective synergies were confirmed using a thermodynamic model. Efficiencies observed with microemulsions comprised of racemic dibutyl tartrate or dibutyl-D-tartrate were significantly higher than those obtained with dibutyl-L-tartrate, with an average difference in plate count of about 25 000. Finally, one two-chiral-component microemulsion (RXS) provided significantly better resolution than the remaining one- and two-chiral-component microemulsions for the ephedrine-based compounds, but only slightly better or equivalent resolution for non-ephedrine compounds.  相似文献   

12.
The article reports a simple, sensitive and fast LC/MS method for the analysis of L-arginine (L-Arg), asymmetric dimethylarginine (ADMA) and symmetric dimethylarginine (SDMA) in human plasma. The homoarginine was used as the internal standard (IS). The chromatographic separation was achieved on C??(150 mm×2.1 mm, 5 μm) column with a mobile phase consisting of ammonium acetate (0.25 mmol/l) and methanol (93 : 7, v/v), at a flow rate of 0.2 ml/min. L-Arg, ADMA and SDMA were well separated by LC/MS with selective ion mode (SIM). The method was successfully applied to type 2 diabetes mellitus (T2DM) study. Twenty-one healthy controls and twenty-two T2DM patients before and after treatment two years were investigated. The results indicated that the level of ADMA in T2DM was significantly higher than that in healthy controls. Furthermore, ADMA has important association with the development of cardiovascular diseases.  相似文献   

13.
A novel analytical method has been developed for the determination of 14 trace chlorophenols in clam tissues by ion chromatography (IC) coupled with atmospheric pressure chemical ionization mass spectrometry (APCI-MS) in the negative mode. The method comprised a fast ultrasound-assisted extraction using a mixture of methanol/water (4:1v/v) containing 5% triethylamine (TEA) as extraction solvent, solid-phase extraction with an Oasis HLB cartridge and gradient separation using KOH/acetonitrile at a flow rate of 1.0 mL/min on an IonPac AG11 guard column (50 mm x 4.0 mm I.D.) and an IonPac AS11 analytical column (250 mm x 4.0 mm I.D.). The molecular ions m/z [M-H](-) 127, 129; 161, 163; 195, 197 and 263, 265, 267 were selected for quantification in the selected ion monitoring (SIM) mode for monochlorophenols (MCPs), dichlorophenols (DCPs), trichlorophenols (TCPs) and pentachlorophenol (PCP), respectively. The average recoveries of the objective compounds spiked in clam tissues were between 80.2% and 98.2%. Within-day and day-to-day relative standard deviations were less than 12.6% and 13.2%, respectively. The optimum IC-APCI-MS conditions were successfully applied to the analyses of 14 trace chlorophenols in clam tissues.  相似文献   

14.
Chromatographic methods have been developed for the separation of the three novel biocompatible iron chelators pyridoxal isonicotinoyl hydrazone (PIH), salicylaldehyde isonicotinoyl hydrazone (SIH), and pyridoxal 2-chlorobenzoyl hydrazone (o-108) from their synthetic precursors and iron chelates. The chromatographic analyses were achieved using analytical columns packed with 5 microm Nucleosil 120-5 C18. For the evaluation of all chelators in the presence of the synthetic precursors, EDTA was added to the mobile phase at a concentration of 2 mM. The best separation of PIH and its synthetic precursors was achieved using a mixture of phosphate buffer (0.01 M NaH2PO4, 5 mM 1-heptanesulfonic acid sodium salt; pH 3.0) and methanol (55:45, v/v). For separation of SIH and its synthetic precursors, the mobile phase was composed of 0.01 M phosphate buffer (pH 6.0) and methanol (60:40, v/v). o-108 was analyzed employing a mixture of 0.01 M phosphate buffer (pH 7.0), methanol, and acetonitrile (60:20:20, v/v/v). These mobile phases were slightly modified to separate each chelator from its iron chelate. Furthermore, a RP-TLC method has also been developed for fast separation of all compounds. The chromatographic methods described herein could be applied in the evaluation of purity and stability of these drug candidates.  相似文献   

15.
The characteristics of the retention and the mass transfer kinetics in reversed-phase liquid chromatography (RPLC) were measured on a system consisting of a C18-silica gel and a tetrahydrofuran-water (50:50, v/v) solution. These parameters were derived from the first and the second moments of the elution peaks, respectively. Further information on the thermodynamic properties of this system was derived from the temperature dependence of these moments. Some correlations previously established were confirmed for this system, namely, an enthalpy-entropy compensation for both retention and surface diffusion and a linear free-energy relationship. These results are compared with those observed in other similar systems using methanol-water (70:30, v/v) and acetonitnile-water (70:30, v/v) solutions. The contribution of surface diffusion to intraparticle diffusion in C18-silica gel particles was shown to be important. The analysis of the thermodynamic properties of surface diffusion suggests that, in these three RPLC systems, its activation energy is lower than the isosteric heat of adsorption. The nature and the extent of the influence of the mobile phase composition on the parameters describing the retention and the mass transfer kinetics are different but the chromatographic mechanisms involved in RPLC systems appear similar, irrespective of the nature of the organic modifier in the mobile phase.  相似文献   

16.
The separation and determination of five herbicides, including propanil and the phenylureas diuron, isoproturon, linuron and neburon, has been performed by an HPLC method, using photochemically-induced fluorescence detection. The non-fluorescent herbicides were transformed into fluorescent compounds by post-column photochemical reaction. A 60:40 (v/v) acetonitrile-buffer solution of potassium phosphate dibasic (pH 7, 0.01 M) was used for the chromatographic elution to separate propanil, linuron and neburon. The overlapping of isoproturon and diuron peaks, in the selected conditions, was resolved by changing the initial movil phase composition to 50:50 (v/v) methanol-buffer solution of potassium phosphate dibasic (pH 7, 0.01 M). The procedure was applied with satisfactory results to the analysis of these herbicides in Guadiana river water samples (Badajoz, Spain), allowing the detection of herbicide residues in the order of mug l(-1), by using a solid-phase extraction (SPE) pre-concentration step.  相似文献   

17.
A liquid chromatographic/tandem mass spectrometric method is described for the determination of phencyclidine (PCP) in small volumes of rat serum (e.g. 50 microl). Samples were extracted using a mixed-mode strong cation-exchange column and then separated isocratically using a narrow-bore (2.1 mm i.d.) 3 microm Hypersil phenyl column and a mobile phase consisting of an ammonium formate buffer (pH 2.7) with 60% (v/v) methanol. Detection was accomplished using positive ion electrospray ionization in the multiple reaction monitoring mode. Mass spectra were obtained and peaks were observed at an m/z (% abundance) of 244 (100), 159 (25), and 86 (89). Tandem mass spectra were also obtained from the m/z 244 precursor ion with peaks observed at m/z 159 (100), 86 (96), and 91 (11). Optimum serum PCP sensitivity and precision were obtained at a transition of m/z 244 --> 159. Matrix-associated ion suppression did not significantly affect the accuracy (100-112%) or precision (CV < or =8%) of the assay. The lower limit of quantitation was 1 ng ml(-1) in 50 microl of serum. The method was used to study the serum pharmacokinetics of PCP in rats after an intravenous bolus dose of PCP.  相似文献   

18.
Vosough M  Mojdehi NR 《Talanta》2011,85(4):2175-2181
A fast chromatographic method is presented for simultaneous quantification of seven organic ultraviolet (UV) filters (benzophenone-3,4-methylbenzilidene camphor, octocrylene, 1-(4-tert-butylphenyl)-3-(4-methyoxyphenyl)1,3-propanedione), ethylhexyl methoxy cinnamate, ethylhexyl salicylate and homosalate) in effluent wastewater samples. The UV filters were pre-concentrated by Bond Elut-ENV cartridges and separated on an ODS column (15 cm × 0.46 cm, 5 μm) in less than 2.5 min using a non-aqueous mobile phase of methanol-acetonitrile (50:50, v/v) with flow-rate of 1.5 mL min−1. Appropriate baseline correction through asymmetric least squares was applied to reduce the matrix of background signals in three way data. Then, second-order calibration based on multivariate curve resolution-alternating least squares (MCR-ALS) was implemented on the unfolded three-way data obtained from liquid chromatography with diode array detection (LC-DAD) through standard addition calibration method for handling co-eluted peaks, systematic and proportional errors. Recoveries ranging from 76% to 130% and %RSD values less than 11.2 for all UV filter shows the accuracy and precision of the proposed method in wastewater samples. In addition, statistical t-test as well as computed elliptical joint confidence region (EJCR) confirms the accuracy of the proposed method and indicates the absence of both constant and proportional errors in the predicted concentrations. This study demonstrates that coupling of the fast HPLC-DAD method with powerful algorithm of MCR-ALS can be considered as an efficient method for quantification of UV filters in highly contaminated samples of wastewaters where both time and cost per each analysis can be reduced significantly.  相似文献   

19.
Hyphenation of thin layer chromatography (TLC) with surface-based spectral methods requires a homogeneous surface for direct and quantitative analysis on the chromatographic plate after separation. Since most chromatographic materials do not produce strong background signals in Raman spectroscopy (RS) or surface-enhanced RS (SERS), we tested the suitability of two different chromatographic substrates and one interface for coupling SERS with TLC. This was carried out by using a chromatographic thin layer, specially produced for RS measurements, and a monolithic silica thin layer. A typical TLC plate with a modified aluminium backplate foil on one side was used as an interface. Three biologically active diterpenes, namely gibberellic acid (GA), abietic acid (AA) and kaurenoic acid (KA), were used as test analytes. Stock solutions were applied directly onto the surface, followed by the addition of silver colloid and measurements were taken by SERS. The strongest signal (excitation at 514.5 nm) was obtained for GA using a Raman treated thin layer where the enhancement factor value was determined to be 102. Several fundamental Raman bands for GA were found at 1622, 1593, 1570, 1542, 1366 and 1236 cm−1. When the monolithic silica layer was used, no useful SERS signals were observed. The SERS spectra on modified aluminium backplate for AA and GA were quite similar and no SERS spectrum was obtained for KA. Future research will be concerned towards the use of nanostructured surfaces for SERS analysis. An erratum to this article can be found at  相似文献   

20.
A liquid chromatographic method with fluorimetric detection was developed to measure taurine (2-aminoethanesulfonic acid) in feline plasma and whole blood. Plasma or lysed whole blood was diluted with a mixture of acetonitrile-methanol-triethylamine-water (25:22:3:50, v/v), filtered through a 10,000 dalton exclusion filter and derivatized with dansyl chloride for 30 min at room temperature. Dansyl taurine was separated from other compounds by reversed-phase liquid chromatography using an octadecyl column and a methanol-acetic acid-triethylamine (30:0.5:0.025, v/v) aqueous mobile phase. The effluent was monitored fluorimetrically at an excitation wavelength of 329 nm and an emission wavelength of 530 nm. The presence of mono-dansylated taurine in feline plasma was confirmed by thermospray mass spectrometry. The limit of detection was 16 nmol/ml and the detector response was linear from 40 to 4000 nmol/ml taurine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号