首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Lechner ML  Somogyi MA  Biró ML 《Talanta》1966,13(4):581-587
A quantitative method for the determination of chlorophenols and chlorophenoxyacetic acids in aqueous solutions is described. The samples investigated contained 2-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol, 2,4,6-trichlorophenol and their phenoxyacetic acid derivatives. The total amount of chlorophenols is determined by spectrophotometry, the ratio of individual chlorophenols by gas chromatography and the total quantity of phenoxyacetic acids by acidimetric titration. The determinations are carried out after extraction with diethyl ether, carbon tetrachloride and petroleum ether, respectively.  相似文献   

2.
A chiral crown ether column with a pH 1.9 perchloric acid buffered aqueous mobile phase is used to separate amino acid enantiomers by high performance liquid chromatography. An inductively coupled plasma atomic emission spectrometer coupled to the chromatographic system is used as a detector by monitoring the carbon atomic emission line at 193.09 nm. Seven underivatized amino acids are separated and detected resulting in an average mass detection limit of 5 ng (2.5 ng carbon). The chiral crown ether column resolves compounds with a primary amino group near the chiral center by forming a complex between the crown ether and an ammonium ion moiety from the sample. The -form amino acid always elutes faster than its antipode. The carbon emission detector provides nearly identical sensitivities and similar detection limits for any compounds with comparable mass percents of carbon. Quantification is performed on unknown ratios of amino acids using an internal standard without the need for a calibration curve. Summing the calculated amounts of and amino acid and comparing to the known mixture quantity results in an average error of 1.0% for the seven amino acids separated.  相似文献   

3.
A complete methodology, incorporating a novel clean-up technique, for quantitative determination of amino acids in plasma by gas chromatography is described. Glucose, a component causing major analytical interference, is removed by an enzymic reaction included in the pre-chromatographic clean-up. The procedure for derivatisation of amino acid standards is shown to be reproducible down to a level of 2.5 micrograms for each amino acid, relative standard deviations for all amino acids except arginine and histidine being 3% or lower. For the entire procedure applied to plasma, relative standard deviations for most amino acids are below 5% with recoveries ranging from 90 to 120%. Normal values, obtained using eighteen plasma samples, are in reasonable agreement with published data. Plasma amino acid values were determined simultaneously by gas chromatographic and ion-exchange chromatographic techniques. Statistical evaluation shows there to be no significant difference between corresponding values for eleven amino acids. Values for tyrosine, histidine and particularly phenylalanine show significant differences (p less than 0.001).  相似文献   

4.
Smithia conferta Sm. (Leguminasae), is a commonly used plant in Indian traditional medicine. In the current study anti-ulcer activity of its petroleum ether, alcohol and aqueous extracts of leaves were investigated using different animal models. All extracts were also subjected to phytochemical analysis and their toxic potential. Petroleum ether extract was found to contain steroids; alcohol extract revealed the presence of isoflavonoids, alkaloids and carbohydrates; while aqueous extract was found to contain amino acids, carbohydrates and flavonoids. S. conferta aqueous and alcoholic extracts were found to be non-toxic up to 5000 mg/kg dose level while petroleum ether extract was safe only up to a dose of 2000 mg/kg after single dose administration of the extracts.During confirmation of the claimed anti-ulcer activity, treatment with aqueous and alcoholic extracts showed significant reduction in ulcer index, free acidity as well as total acidity in pylorus ligated rats. However, petroleum ether extract showed relatively less profound reduction in all these indices. The anti-ulcer activity observed in aqueous extract treatment group was nearly equivalent to the standard group.  相似文献   

5.
A procedure for determining the amino acid and sugar composition of streptococcal peptidoglycan-polysaccharide complexes by capillary gas chromatography-mass spectrometry (GC-MS) was established. Amino acids are analysed as butyl heptafluorobutyl derivatives and sugars as alditol acetates. These two different groups of compounds are derivatized independently but chromatography in both cases utilizes the same OV-1701 fused-silica capillary column which simplifies GC-MS analysis. The butyl heptafluorobutyl procedure incorporates new pre- and post-derivatization clean-up steps. Additionally, selected-ion monitoring MS allows amino acids to be readily analysed without interference from background noise.  相似文献   

6.
A capillary chromatographic procedure using a fused silica column is described which can be used to quantitatively determine amino acids in plasma following the pre-chromatographic “clean-up” described in a recent paper [1]. In substituting this procedure for that involving a packed column, advantage has been taken of the greater resolving power to separate amino acids from background component peaks. In order to extend this advantage and provide a sound basis for quantitative analysis, the technique of cold on-column injection was employed. As a result, good precision of standard analysis was obtained with relative standard deviation (RSD) values for all amino acids of less than 4%. Application of the entire procedure to plasma samples yields RSD values of better than 10% for all amino acids with recoveries ranging from 72% to 104%. Simultaneous determination of plasma amino acid levels by gas chromatography (GC) using capillary columns and by classical ion exchange (CIE) showed reasonable agreement. Statistical evaluation showed no significant difference between twelve amino acids. Values for the remaining two, namely, phenylalanine and histidine are significantly different (p < 0.005). Comparison of the values obtained from GC capillary and packed columns reveals no significant difference between fourteen amino acids. Significant differences exist between results for phenylalanine and tyrosine (p < 0.001). It is concluded that there is good agreement between data obtained by GC capillary and CIE techniques and that differences between results for phenylalanine and histidine are method related.  相似文献   

7.
The densities of 18-crown-6-water and 18-crown-6-amino acid-water solutions at 298.15 K were determined. These values were used to estimate the partial molar volumes of 18-crown-6 in water and 0.15 M aqueous solutions of amino acids, as well as the volumes of transfer of 18-crown-6 from water to aqueous solutions of amino acids. The interaction of 18-crown-6 with amino acids involves H bonds and electrostatic forces. A conclusion was drawn that the nature and arrangement of side groups in amino acids affect their complex formation with the crown ether.  相似文献   

8.
Crown ethers of suitable size are the perfect artificial host compounds for ammonium ion binding, but the rather low affinity in aqueous solution prevents their use at physiological conditions. We report here the synthesis and properties of a luminescent benzo crown ether with a pendant copper imidodiacetic acid complex, which coordinates with high affinity to histidine. The emission intensity of the benzo crown ether increases significantly in the presence of ammonium ions in methanol. At physiological conditions in buffered water at pH 7.5 these interactions are too weak to be detected. If an ammonium ion and an imidazole moiety are present in the analyte, such as in His-Lys-OMe or His-OMe, high binding affinity in aqueous solution is restored. The binding event is signaled by an increase in emission intensity, which can even be observed with the naked eye. This allows the selective detection of small peptides containing N-terminal histidine or histidine among all other amino acids at physiological conditions.  相似文献   

9.
Among the techniques available for quantitative analysis of physiological amino acids, systems using optical detection are of low specificity because of possible interference at the analytical wavelength. Another disadvantage is problems of sample extraction from complex biological matrices, for example plasma. This paper describes reversed-phase LC of phenylthiocarbamyl (PTC) amino acids in plasma deproteinated by addition of acetonitrile. Specificity was monitored by photo-diode UV detection and accuracy was assessed by a plasma spiking procedure with more than one internal standard. Dual-wavelength spectrophotometry (254 and 283 nm) was also used for separate measurement of co-eluting adducts of tryptophan and ornithine. This method enables the quantification, with high reproducibility, of a total of twenty-three plasma amino acids from fasting healthy subjects. LOQ values are satisfactory for all the amino acids (average 6 μmol L?1). However, the method does not enable analysis of aspartate and overall homocystine, present at very low concentrations, in all plasma samples. This PTC–amino acid chromatographic method is inexpensive, reliable, and suitable for clinical research and therapeutic drug monitoring, but adaptation to dual on-line detection is required to improve its sensitivity.  相似文献   

10.
水稻秸秆石油醚和乙醇萃取物的组成分析   总被引:2,自引:2,他引:0  
宫贵贞  曹洪 《应用化学》2014,31(6):726-731
用石油醚和乙醇在索式萃取器中对水稻秸秆进行了萃取,萃取物用傅里叶转换红外光谱仪(FTIR)和气相色谱 质谱联用仪(GC/MS)分析。 结果表明,乙醇和石油醚的萃取率分别为8%和6%。 萃取物中共检测到40种物质,主要分为醇酚(APs)、醛、酮、酸、酯、烃(HCs)及含氮化合物(ONs)7种类别。 其中,石油醚萃取物中酯、HCs和APs 3类物质含量较高,总的相对含量为91.7%;乙醇萃取物中HCs、酸、酯及APs含量较高,总的相对含量为83.9%。 该研究在开发稻秆的高附加值利用方面具有重要的基础理论意义。  相似文献   

11.
A quantitative procedure for the analysis of volatile organic acids and lactic acid in silage is described. The samples were extracted with diethyl ether, derivatized by t-butyldimethylsilylation, and then separated by capillary gas chromatography. The same procedure was useful for the identification by gas chromatography/mass spectrometry of organic acids in samples such as the metabolic fermentation products of anaerobic bacteria.  相似文献   

12.
A procedure was developed for the determination of trace petroleum products in water by gas chromatography with steam as the carrier gas. Solid-phase microextraction was used for sample preparation. A method for the stabilization and homogenization of water samples before the analysis and a method for the removal of polar components of the sample were proposed. The precision and accuracy indices of the proposed procedure were estimated for aqueous solutions of a mixture of diesel fuel and oil with a concentration close to the maximum permissible concentration. The relative error in the measurement is no more than ~25% in the concentration range of petroleum products of 0.05–0.5 mg/L.  相似文献   

13.
A practical method for the quantitative determination of protein amino acids by gas-liquid chromatography (GLC) is described. All of the common protein amino acids except arginine can be readily converted into their N-isobutyloxycarbonyl (N-isoBOC) methyl ester derivatives by a simple procedure involving isobutyloxycarbonylation with isobutyl chloroformate in aqueous medium, followed by methylation with diazomethane. Arginine was converted into N-isoBOC ornithine methyl ester by treatment with arginase, followed by the above derivatization procedure. The resulting N-isoBOC methyl esters of the amino acids have good GLC properties. Complete resolution of the derivatives of 20 protein amino acids was achieved by using a dual-column system consisting of a 0.65% Poly-A-101A column and a 0.70% FFAP-Poly-A-101A (1:1, w/w) column. The reproducibility of response was found to be good for derivatives carried through the entire chemical and chromatographic procedure. The calibration graphs were linear and showed no statistical bias. The results of recovery experiments with synthetic mixtures containing known amounts of the amino acids were satisfactory, the recoveries ranging from 94.3 to 106.2%.  相似文献   

14.
Several amino acid enantiomer derivatives were prepared with different chloroformates and analysed by gas chromatography (GC) on a Chirasil-L-Val GC column, at a temperature below 200 degrees C. Among them the N(O,S)-ethoxycarbonyl heptafluorobutyl esters presented the best compromise between short retention times, high yield responses and good resolution for almost all the tested amino acids. These derivatives proved to be suited for quantification of amino acids in aqueous media, with L-p-chlorophenylalanine as internal standard. The developed procedure was applied to several food samples for determination of their free amino acid profiles.  相似文献   

15.
In order to comprehensively evaluate the aroma-active substances and taste components of durian, solid-phase microextraction combined with gas chromatography mass spectrometry (SPME/GC-MS), high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) and ultra-high-performance liquid chromatography (UHPLC) were used to test the key components of three popular durian cultivars. A total of 27 volatile compounds, 5 sugars, 27 organic acids and 19 free amino acids were detected in Black Thorn (BT) durian. A total of 38 volatile compounds, 4 sugars, 27 organic acids and 19 free amino acids were detected in Monthong (MT) durian. A total of 36 volatile compounds, 4 sugars, 27 organic acids and 20 free amino acids were detected in Musang King (MK) durian. Finally, the flavor differences of the three durians were evaluated using electronic nose (e-nose) and electronic tongue (e-tongue), and different cultivars were classified through principal component analysis (PCA).  相似文献   

16.
Amino acids Trp, Gly, Ala, Leu are extracted efficiently from aqueous solution at pH 1.5–4.0 (Lys and Arg at pH 1.5–5.5) into the room temperature ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (BmimPF6) with dicyclohexano-18-crown-6 (CE). The most hydrophilic amino acids such as Gly are extracted as efficiently as the less hydrophilic (92–96%). The influence of pH, amino acid and crown ether concentration, volume ratio of aqueous and organic phases, and presence of some cations on amino acid recovery were studied. The ratio of amino acid to crown ether in the extracted species is 1:1 for cationic Trp, Leu, Ala, and Gly and to 1:2 for dicationic Arg and Lys. This ionic liquid extraction system was used successfully for the recovery of amino acids from pharmaceutical samples and fermentation broth, and was followed by fluorimetric determination.These results were published in part in Smirnova SV (2002) Ph.D. Thesis, Moscow State University.  相似文献   

17.
Amino acids in biological fluids have previously been shown to be detectable using liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) with perfluorinated acids as ion-pairing agents. To date, these studies have used precursor mass, retention time and tandem mass spectrometry (MS/MS) to identify and quantify amino acids. While this is a potentially powerful technique, we sought to adapt the method to time-of-flight (TOF)MS. A new application of a recently described liquid chromatographic separation method was coupled with TOFMS to employ accurate mass for qualitative identification; resulting in additional qualitative data not available with standard single quadrupole data. In the current study, we evaluated 25 physiological amino acids and one dipeptide that are routinely quantified in human plasma. Accuracy and precision of the method was evaluated by spiking human plasma with a mix of the 25 amino acids; in addition, the inclusion of a cation-exchange cleanup step was evaluated. The calibration curves were linear over a range from 1.56 to 400 microM. The dynamic range was found to be within physiological levels for all amino acids analyzed. Accuracy and precision for most of the amino acids was between 80-120% spike recovery and <10% relative standard deviation (RSD). The LC/MS technique described in this study relies on mass accuracy and is suitable for the quantitation of free amino acids in plasma.  相似文献   

18.
A method to quantitate blood and plasma amino acids by isotope dilution gas chromatography/mass spectrometry (GC/mS) is described. Samples were spiked with U-(13)C amino acids as internal standards and the tert-butyldimethylsilyl derivatives (tBDMS) separated by capillary column gas chromatography. Linear regression curves, generated for individual amino acids, gave correlation coefficients of 0.9999. The reproducibility of the method was assessed from the analysis of 10 replicate blood and plasma samples. For most amino acids a coefficient of variance (CV) of 相似文献   

19.
Plasma chemically modified carbon nanofibers were characterized by X-ray photoelectron spectroscopy with regard to the content of carbon, oxygen, and nitrogen and the contribution of carboxylic groups or ester, carbonyl and hydroxylic groups or ether on the surface. Unfortunately, X-ray photoelectron spectroscopy only provides an average value of the first 10 to 15 molecular layers. For comparison, depth profiles were measured and wet chemical methods were applied to estimate the thickness of the functionalized layer and the distribution of oxygen-containing functional groups within the near-surface layers. The results indicate that the fiber surface is covered by a monomolecular oxygen-containing layer and that plasma treatment allows a complete oxygen functionalization of the uppermost surface layer. The best conditions for plasma treatment found within the set of parameters applied to generate complete functionalization are: plasma gas O(2)/Ar ratio 1:1, gas pressure 1-1.5 hPa, plasma power 80 W, treatment time >or= 5 min. Additionally, three quick and easy methods are presented to estimate the efficiency of plasma treatment with regard to surface functionalization: pyrolysis, contact angle measurements, and light permeability measurements of aqueous carbon nanofiber suspensions.  相似文献   

20.
建立毛细管柱气相色谱法测定液化石油气中二甲醚含量的分析方法。采用静止进样法直接进样,用PLOT–Q毛细管色谱柱进行分离,以FID检测器进行检测,外标法进行定量分析。液化石油气中二甲醚的含量(体积分数)在0%~20.0%范围内与其色谱峰面积呈良好线性关系,线性相关系数r=0.999 9,方法检出限为0.05%(体积分数),测定结果的相对标准偏差小于5%(n=6),回收率在98.2%~102.9%之间。该方法与校正面积归一法测定结果相一致。该方法准确、快速、简便,适用于液化石油气中二甲醚含量的检测。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏