首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 456 毫秒
1.
A mixture of piracetam and vincamine was determined by 3 different methods. The first was the determination of piracetam and vincamine using the ratio-spectra first-derivative (DD1) spectrophotometric technique at 209 and 293 nm in concentration ranges of 10-45 and 2-14 microg/mL with mean recoveries of 99.22 +/- 0.72 and 99.67 +/- 0.79%, respectively. The second method was based on the resolution of the 2 components by bivariate calibration depending on a mathematic algorithm that provides simplicity and rapidity. The method depended on quantitative evaluation of the absorbencies at 210 and 225 nm in concentration ranges of 5-45 and 2-14 microg/mL, with mean recoveries of 100.33 +/- 0.54 and 100.44 +/- 0.98% for piracetam and vincamine, respectively. The third method was reversed-phase liquid chromatography using 0.05 M potassium dihydrogen phosphate-methanol (50 + 50, v/v) as the mobile phase, with the pH adjusted to 3.5 with phosphoric acid. The eluent was monitored at 215 nm in concentration ranges of 5-100 and 2-200 microg/mL, with mean recoveries of 99.62 +/- 0.67 and 99.32 +/- 0.85% for piracetam and vincamine, respectively. The suggested procedures were checked using laboratory-prepared mixtures and were successfully applied for the analysis of their pharmaceutical preparation. The methods retained their accuracy and precision when applying the standard addition technique. The results obtained by applying the proposed methods were statistically analyzed and compared with those obtained by the manufacturer's method.  相似文献   

2.
Four new methods were developed and validated for the determination of cinnarizine HCl in its binary mixture with piracetam in pure and pharmaceutical preparations. The first one was a densitometric analysis that provides a simple and rapid method for the separation and quantification of cinnarizine HCI. The method depends on the quantitative densitometric evaluation of thin-layer chromatograms of cinnarizine HCI at 252 nm over concentration range of 1-6 microg/spot, with a mean accuracy of 100.05 +/- 0.91%. The second method was determination of the drug using a colorimetric method that utilizes the reaction of 3-methyl-benzothiazolin-2-one in the presence of FeCl3 as an oxidant. The green color of the resulting product was measured at 630 nm over concentration range 10-40 microg/mL, with a mean accuracy of 100.10 +/- 1.13%. The third method was a direct spectrophotometric determination of cinnarizine HCI at 252 nm over the concentration range 7-20 microg/mL, while piracetam was determined by derivative ratio spectrophotometry at 221.6 nm over concentration range 5-30 microg/mL, with a mean accuracy of 100.14 +/- 0.79 and 100.26 +/- 1.24% for cinnarizine HCI and piracetam, respectively. The last method was a liquid chromatography analysis of both cinnarizine HCI and piracetam, depending on quantitative evaluation of chromatograms of cinnarizine HCI and piracetam at 252 and 212 nm, respectively, over the concentration range 10-200 microg/mL for cinnarizine HCI and 20-500 microg/mL for piracetam, with a mean accuracy of 100.03 +/- 0.89 and 100.40 +/- 0.94% for cinnarizine HCI and piracetam, respectively. The proposed procedures were checked using laboratory-prepared mixtures and successfully applied for the analysis of their pharmaceutical preparations. The validity of the proposed procedures was further assessed by applying the standard addition technique. Recoveries were quantitative, and the results obtained agreed with those obtained by other reported methods.  相似文献   

3.
Four stability-indicating assays were developed for determining omeprazole and octylonium bromide. Omeprazole is photodegraded and estimated in the presence of its degradation products sulphenamide (I) and benzimidazole sulphide (II) by 2 methods. The first method depends on use of first-, second-, and third-derivative spectrophotometry at 290.4, 320.6, and 311.6 nm, respectively. The second method is based on applying the charge-transfer technique with chloranil as pi acceptor to form a complex with omeprazole, the absorbance of which is measured at 377 nm. These methods determine omeprazole in concentration ranges of 5-20 micrograms/mL by first-, second-, and third-derivative spectrophotometry and 10-50 micrograms/mL by charge-transfer complexation with mean accuracies of 99.92 +/- 0.73, 99.71 +/- 1.02, 99.64 +/- 0.66, and 100.24 +/- 0.81%, respectively. Octylonium bromide is determined by a densitometric method using thin-layer chromatography in the presence of its degradation products p-[2-(n-octyoxy)benzoyl]-aminobenzoic acid (III) and diethyl-(2-hydroxyethyl)-methyl ammonium bromide (IV) without any interferences. Alternatively, octylonium bromide is evaluated by a colorimetric method using the acid dye rose bengal. The ion pair formed is extracted in chloroform at pH 4, and its absorbance is measured at 562 nm. These methods determine octylonium bromide in the presence of its degradation products in concentration ranges of 0.1-0.5 microgram/microL by densitometry and 4.5-22.5 micrograms/mL by colorimetry, with mean accuracies of 100.21 +/- 0.93 and 99.73 +/- 0.89%, respectively. The suggested methods were used to determine drugs in bulk powder, laboratory-prepared mixtures, and pharmaceutical dosage forms. Results were compared statistically with those obtained with reference methods.  相似文献   

4.
Thin-layer chromatography, first derivative, ratio spectra derivative spectrophotometry and Vierordt's method have been developed for the simultaneous determination of paracetamol and drotaverine HCl. TLC densitometric method depends on the difference in Rf values using ethyl acetate:methanol:ammonia (100:1:5 v/v/v) as a mobile phase. The spots of the two drugs were scanned at 249 and 308 nm over concentration ranges of 60-1200 microg/ml and 20-400 microg/ml with mean percentage recovery 100.11%+/-1.91 and 100.15%+/-1.87, respectively. The first derivative spectrophotometric method deals with the measurements at zero-crossing points 259 and 325 nm with mean percentage recovery 99.25%+/-1.08 and 99.45%+/-1.14, respectively. The ratio spectra first derivative technique was used at 246 and 305 nm with mean percentage recovery 99.75%+/-1.93 and 99.08%+/-1.22, respectively. Beer's law for first derivative and ratio spectra derivative methods was obeyed in the concentration range 0.8-12.8 and 0.4-6.4 microg/ml of paracetamol and drotaverine HCl, respectively. Vierordt's method was applied to over come the overlapping of paracetamol and drotaverine HCl in zero-order spectra in concentration range 2-26 and 2-40 microg/ml respectively. The suggested methods were successfully applied for the analysis of the two drugs in laboratory prepared mixtures and their pharmaceutical formulation. The validity of the methods was assessed by applying the standard addition technique. The obtained results were statistically agreed with those obtained by the reported method.  相似文献   

5.
Three new, different, simple, sensitive, and accurate methods were developed for quantitative determination of nifuroxazide (I) and drotaverine hydrochloride (II) in a binary mixture. The first method was spectrophotometry, which allowed determination of I in the presence of II using a zero-order spectrum with an analytically useful maximum at 364.5 nm that obeyed Beer's law over a concentration range of 2-10 microg/mL with mean percentage recovery of 100.08 +/- 0.61. Determination of II in presence of I was obtained by second derivative spectrophotometry at 243.6 nm, which obeyed Beer's law over a concentration range of 2-10 microg/mL with mean recovery of 99.82 +/- 1.46%. The second method was spectrodensitometry, with which both drugs were separated on a silica gel plate using chloroform-acetone-methanol-glacial acetic acid (6 + 3 + 0.9 + 0.1) as the mobile phase and ultraviolet (UV) detection at 365 nm over a concentration range of 0.2-1 microg/band for both drugs, with mean recoveries of 99.99 +/- 0.15 and 100.00 +/- 0.34% for I and II, respectively. The third method was reversed-phase liquid chromatography using acetonitrile-water (40 + 60, v/v; adjusted to pH 2.55 with orthophosphoric acid) as the mobile phase and pentoxifylline as the internal standard at a flow rate of 1 mU/min with UV detection at 285 nm at ambient temperature over a concentration range of 2-10 microg/mL for both drugs, with mean recoveries of 100.24 +/- 1.51 and 100.08 +/- 0.78% for I and II, respectively. The proposed methods were checked using laboratory-prepared mixtures and were successfully applied for the analysis of pharmaceutical formulations containing the above drugs with no interference from other dosage form additives. The validity of the suggested procedures was further assessed by applying the standard addition technique which was found to be satisfactory, and the percentage recoveries obtained were in accordance with those given by the EVA Pharma reference spectrophotometric method.  相似文献   

6.
New, simple, rapid, and precise reversed-phase high-performance liquid chromatographic (LC) methods were developed for the simultaneous determination of chlorzoxazone (CH) and ketoprofen (KT) in binary mixtures and in ternary mixtures containing the CH degradation product, 2-amino-4-chlorophenol (CD). The analytes were separated by LC on a Lichrosphere 60 C18 column (250 x 4 mm, 5 microm). The mobile phases, methanol-water (40:60, v/v) at 1 mL/min and methanol-0.05% phosphoric acid (60:40, v/v, pH 2.81) at 1.5 mL/min, satisfactorily resolved the binary and ternary mixtures, respectively. The UV detector was operated at 280 nm for the determination of CH and at 254 nm for the determination of KT and CD. Linearity, accuracy, and precision were found to be acceptable over the concentration ranges of 20-240 and 5-60 microg/mL for CH and KT, respectively, in the binary mixtures and 50-300, 10-60, and 20-160 microg/mL for CH, KT, and CD, respectively, in the ternary mixtures. The optimized methods proved to be specific, robust, and accurate for the quality control of CH and KT in pharmaceutical preparations.  相似文献   

7.
8.
Four polyvinyl chloride (PVC) membrane sensors for the determination of hyoscine butylbromide are described and characterized. The sensors are based on the use of the ion association complexes of hyoscine cation with ammonium reineckate counter anions as ion exchange sites in the PVC matrix. The membranes incorporate ion association complexes of hyoscine with dibutylsebathete (sensor 1), dioctylphthalate (sensor 2), nitrophenyl octyl ether (sensor 3) and β-cyclodextrin (sensor 4). The performance characteristics of these sensors were evaluated according to IUPAC recommendations, which reveal a fast, stable and linear response for hyoscine over the concentration range of 10−5-10−2 M for sensors 1 and 2 and 10−6-10−2 for sensors 3 and 4 with cationic slopes of −53.19, −55.17, −51.44 and −51.51 mV per concentration decade for the four sensors, respectively. The direct potentiometric determination of hyoscine butylbromide using the proposed sensors gave average recoveries % of 99.92 ± 1.11, 99.93 ± 1.00, 99.94 ± 1.18 and 99.87 ± 1.39 for the four sensors, respectively. The sensors are used for determination of hyoscine butylbromide in laboratory prepared mixtures, pharmaceutical formulations in combination with ketoprofen and in plasma. Validation of the method shows suitability of the proposed sensors for use in the quality control assessment of hyoscine butylbromide. The developed method was found to be simple, accurate and precise when compared with a reported HPLC method.  相似文献   

9.
Four different stability-indicating procedures are described for determination of tiapride in pure form, dosage form, and human plasma. Second derivative (D2), first derivative of ratio spectra (1DD), spectrofluorimetric, and high-performance column liquid chromatographic (LC) methods are proposed for determination of tiapride in presence of its acid-induced degradation products, namely 2-methoxy-5-(methylsulfonyl) benzoic acid and 2-diethylaminoethylamine. These approaches were successfully applied to quantify tiapride using the information included in the absorption, excitation, and emission spectra of the appropriate solutions. In the D2 method, Beer's law was obeyed in the concentration range of 1.5-9 microg/mL with a mean recovery of 99.94 +/- 1.38% at 253.4 nm using absolute ethanol as a solvent. In 1DD, which is based on the simultaneous use of the first derivative of ratio spectra and measurement at 245 nm in absolute ethanolic solution, Beer's law was obeyed over a concentration range of 1.5-9 microg/mL with mean recovery 99.64 +/- 1.08%. The spectrofluorimetric method is based on the determination of tiapride native fluorescence at 339 nm emission wavelength and 230 nm excitation wavelength using water-methanol (8 + 2, v/v). The calibration curve was linear over the range of 0.2-3 microg/mL with mean recovery of 99.66 +/- 1.46%. This method was also applied for determination of tiapride in human plasma. A reversed-phase LC method performed at ambient temperature was validated for determination of tiapride using methanol-deionized water-triethylamine (107 + 93 + 0.16, v/v/v) as the mobile phase. Sulpiride was used as an internal standard at a flow rate of 1 mL/min with ultraviolet detection at 214 nm. A linear relation was obtained over a concentration range of 2-30 microg/mL with mean recovery of 99.66 +/- 0.9%. Results were statistically analyzed and compared with those obtained by applying the reference method. They proved both accuracy and precision.  相似文献   

10.
This research paper describes validated reversed-phase high-performance column liquid chromatographic (RP-HPLC) and first-derivative UV spectrophotometric methods for the estimation of voriconazole (VOR) in oral suspension powder. The RP-HPLC separation was achieved on Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) using water-acetonitrile (40 + 60, v/v; pH adjusted to 4.5 +/- 0.02 with acetic acid) as the mobile phase at a flow rate of 1.4 mL/min and ambient temperature. Quantification was achieved with photodiode array detection at 255 nm over the concentration range of 0.1-1 microg/mL with mean recovery of 99.49 +/- 0.83% for VOR by the RP-HPLC method. Quantification was achieved with UV detection at 266 nm over the concentration range of 8-20 microg/mL with mean recovery of 99.74 +/- 0.664% for VOR by the first-derivative UV spectrophotometric method. These methods are simple, precise, and sensitive, and they are applicable for the determination of VOR in oral suspension powder.  相似文献   

11.
Ratio subtraction and isosbestic point methods are 2 innovating spectrophotometric methods used to determine vincamine in the presence of its acid degradation product and a mixture of cinnarizine (CN) and nicergoline (NIC). Linear correlations were obtained in the concentration range from 8-40 microg/mL for vincamine (I), 6-22 microg/mL for CN (II), and 6-36 microg/mL for NIC (III), with mean accuracies 99.72 +/- 0.917% for I, 99.91 +/- 0.703% for II, and 99.58 +/- 0.847 and 99.83 +/- 1.039% for III. The ratio subtraction method was utilized for the analysis of laboratory-prepared mixtures containing different ratios of vincamine and its degradation product, and it was valid in the presence of up to 80% degradation product. CN and NIC in synthetic mixtures were analyzed by the 2 proposed methods with the total content of the mixture determined at their respective isosbestic points of 270.2 and 235.8 nm, and the content of CN was determined by the ratio subtraction method. The proposed method was validated and found to be suitable as a stability-indicating assay method for vincamine in pharmaceutical formulations. The standard addition technique was applied to validate the results and to ensure the specificity of the proposed methods.  相似文献   

12.
Three new, simple, sensitive, and accurate stability-indicating methods were developed for quantitative determination of bisacodyl in the presence of its degradation products, monoacetyl bisacodyl (I) and desacetyl bisacodyl (II), in enteric coated tablets, suppositories, and raw material. The first is a spectrodensitometric method in which the drug is separated from I and II on silica gel plates using chloroform-acetone (9 + 1, v/v) as the mobile phase with ultraviolet detection of the separated bands at 223 nm over a concentration range of 0.2-1.4 microg/band for bisacodyl with mean recovery 100.35 +/- 1.923%. The second method is fourth derivative D4 spectrophotometry, which allows determination of bisacodyl in the presence of its degradation products in raw material at 223 nm using acetonitrile as the solvent with adherence to Beer's law over the concentration range 2-18 microg/mL with mean recovery 99.77+/-1.056%. In the third method, the spectrophotometric data of bisacodyl, I, and II using absolute ethanol as solvent were processed by 3 chemometric techniques: classical least-squares, principal component regression, and partial least-squares. A training set consisting of 15 mixtures containing different ratios of bisacodyl, I, and II was used for construction of the 3 models. A validation set consisting of 6 mixtures was used to validate the prediction ability of the suggested models. The 3 chemometric methods were applicable over a concentration range between 2-14microg/mL for bisacodyl with mean recovery of 99.97+/-0.865, 100.01 +/- 0.749, and 99.97 +/- 0.616% for the 3 models, respectively. The proposed methods were checked using laboratory-prepared mixtures and were successfully applied to the analysis of raw material and pharmaceutical formulations containing bisacodyl, except for the second method that applies only for raw material. The validity of the suggested procedures was further assessed by applying the standard addition technique; the recoveries obtained were in accordance with those given by the reference method.  相似文献   

13.
Two simple, accurate, and reliable spectrophotometric methods have been developed for the determination of 2 antiviral drugs, acyclovir (ACV) and ribavirin (RBV), in their pharmaceutical formulations. These methods are based on oxidation of the 2 drugs with either cerium (IV) ammonium sulfate (Method A) or potassium persulfate (Method B). The products of oxidation in both methods are coupled with 3-methylbenzothiazolin 2-one hydrazone, producing a deep blue color with a maximum absorption wavelength at 630 nm. In Method A, the absorbance-concentration plots were linear over the ranges of 5-50 and 10-60 microg/mL with detection limits of 0.18 microg/mL (8 x 10(-7) M) and 0.63 microg/mL (2.58 x 10(-6) M) for ACV and RBV, respectively. In Method B, the ranges were 5-45 and 20-50 microg/mL with detection limits of 0.11 microg/mL (4.88 x 10(-7) M) and 1.40 microg/mL (5.73 x 10(-6) M) for the 2 drugs, respectively. The molar absorptivities were 4.1 x 10(3) and 3.65 x 10(3) L/mol/cm in Method A and 5.03 x 10(3) and 3.97 x 10(3) L/mol/cm in Method B for the 2 drugs, respectively. The proposed methods were applied successfully for the determination of the 2 drugs in their pharmaceutical formulations. The percentage recoveries +/- standard deviation were 99.57 +/- 0.86 and 100.82 +/- 0.46 for ACV; 99.41 +/- 1.08 and 100.35 +/- 1.03 for RBV. The results obtained were compared statistically with those given by official methods and showed no significant differences regarding accuracy and precision.  相似文献   

14.
This paper describes validated high-performance column liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of acetylsalicylic acid (ASA) and clopidogrel bisulfate (CLP) in pure powder and formulations. The HPLC separation was achieved on a Nucleosil C8 column (150 mm length x 4.6 mm id, 5 microm particle size) using acetonitrile-phosphate buffer, pH 3.0 (55 + 45, v/v) mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol-toluene-glacial acetic acid (5.0 + 1.0 + 4.0 + 0.1, v/v/v/v) mobile phase. Quantitation was achieved with UV detection at 235 nm over the concentration range 4-24 microg/mL for both drugs, with mean recoveries of 99.98 +/- 0.28 and 100.16 +/- 0.66% for ASA and CLP, respectively, using the HPLC method. Quantitation was achieved with UV detection at 235 nm over the concentration range of 400-1400 ng/spot for both drugs, with mean recoveries of 99.93 +/- 0.55 and 100.21 +/- 0.83% for ASA and CLP, respectively, using the HPTLC method. These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of ASA and CLP in pure powder and formulations.  相似文献   

15.
This paper describes validated high-performance liquid chromatographic (LC) and high-performance thin-layer chromatographic (TLC) methods for the simultaneous estimation of olanzapine and fluoxetine in pure powder and tablet formulations. The LC separation was achieved on a Lichrospher 100 RP-180, C18 column (250 mm, 4.0 mm id, 5 microm) using 0.05 M potassium dihydrogen phosphate buffer (pH 5.6 adjusted with o-phosphoric acid)-acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1 mL/min and ambient temperature. The TLC separation was achieved on aluminum sheets coated with silica gel 60F254 using methanol-toluene (40 + 20, v/v) as the mobile phase. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 10-70 and 40-280 microg/mL with mean recovery of 99.54 +/- 0.89 and 99.73 +/- 0.58% for olanzapine and fluoxetine, respectively, by the LC method. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 100-800 and 400-3200 ng/spot with mean recovery of 101.53 +/- 0.06 and 101.45 +/- 0.35% for olanzapine and fluoxetine, respectively, by the TLC method with densitometry. These methods are simple, precise, and sensitive, and they are applicable for simultaneous determination of olanzapine and fluoxetine in tablet formulations.  相似文献   

16.
Two sensitive and selective methods were developed for the determination of some oxicams, namely, lornoxicam (LOX), tenoxicam (TEX), and meloxicam (MEX), in the presence of their alkaline degradation products. The first method is based on the thin-layer chromatographic separation of the 3 drugs from their alkaline degradation products, followed by densitometric measurement of the intact drug spots for LOX, TEX, and MEX at 380, 370, and 364 nm, respectively. The developing systems used for separation are ethyl acetate-methanol-26% ammonia (17 + 3 + 0.35, v/v/v) for LOX and TEX and chloroform-n-hexane-96.0% acetic acid (18 + 1 + 1, v/v/v) for MEX. The linear ranges were 0.25-6.0 microg/spot for LOX and TEX and 0.5-10 microg/spot for MEX, with mean recoveries of 99.80 +/- 1.32, 100.57 +/- 1.34, and 100.71 +/- 1.57%, respectively. The second method is based on the liquid chromatographic separation of the 3 drugs from their alkaline degradation products on a reversed-phase C18 column, using mobile phases of methanol-acetonitrile-acetate buffer, pH 4.6 (4.5 + 0.5 + 5.0, v/v/v) for LOX and MEX and methanol-acetonitrile-acetate buffer, pH 4.6 (1.9 + 0.1 + 3.0, v/v/v) for TEX at ambient temperature. Quantification is achieved by UV detection at 280 nm, based on peak area. The linear ranges were 0.5-20 microg/mL for LOX and TEX and 1.25-50 microg/mL for MEX, with mean recoveries of 99.81 +/- 1.01, 98.90 +/- 1.61, and 100.86 +/- 1.55%, respectively. The methods were validated according to guidelines of the International Conference on Harmonization. The developed methods were successfully applied to the determination of LOX, TEX, and MEX in bulk powder, laboratory-prepared mixtures containing different percentages of degradation products, and pharmaceutical dosage forms.  相似文献   

17.
Simple, accurate, economical, and reproducible UV spectrophotometric and column high-performance liquid chromatographic (HPLC) methods were developed for simultaneous estimation of a 2-component drug mixture of metoprolol tartrate and hydrochlorothiazide in combined tablet dosage form. The first method used the simultaneous equation method with 7 mixed standards and the absorption maxima at 223 and 271 nm, respectively, for metoprolol tartrate and hydrochlorothiazide in methanol. Linearity was observed in the concentration ranges of 4-24 and 2-16 microg/mL for metoprolol tartrate and hydrochlorothiazide, respectively. The developed HPLC method used a reversed-phase C18 column and methanol-water (95 + 5) mobile phase at an ambient temperature of 27 +/- 2 degrees C and UV detection at 225 nm; the run time was 10 min, and quantification was based on peak area. The injection repeatability and intraday and interday repeatability were calculated. Paracetamol was used as an internal standard for the HPLC method, and linearity was observed in the concentration range of 5-50 microg/mL for metoprolol and 2-20 microg/mL for hydrochlorothiazide. The proposed methods were successfully applied for the determination of metoprolol tartrate and hydrochlorothiazide in bulk powder and dosage form. The results obtained were analyzed statistically, and there was no significant difference between the 2 methods. The validation was performed according to International Conference on Harmonization guidelines.  相似文献   

18.
Two simple and accurate methods to determine atorvastatin calcium and ramipril in capsule dosage forms were developed and validated using HPLC and HPTLC. The HPLC separation was achieved on a Phenomenex Luna C18 column (250 x 4.6 mm id, 5 microm) in the isocratic mode using 0.1% phosphoric acid-acetonitrile (38 + 62, v/v), pH 3.5 +/- 0.05, mobile phase at a flow rate of 1 ml/min. The retention times were 6.42 and 2.86 min for atorvastatin calcium and ramipril, respectively. Quantification was achieved with a photodiode array detector set at 210 nm over the concentration range of 0.5-5 microg/mL for each, with mean recoveries (at three concentration levels) of 100.06 +/- 0.49% and 99.95 +/- 0.63% RSD for atorvastatin calcium and ramipril, respectively. The HPTLC separation was achieved on silica gel 60 F254 HPTLC plates using methanol-benzene-glacial acetic acid (19.6 + 80.0 + 0.4, v/v/v) as the mobile phase. The Rf values were 0.40 and 0.20 for atorvastatin calcium and ramipril, respectively. Quantification was achieved with UV densitometry at 210 nm over the concentration range of 50-500 ng/spot for each, with mean recoveries (at three concentration levels) of 99.98 +/- 0.75% and 99.87 +/- 0.83% RSD for atorvastatin calcium and ramipril, respectively. Both methods were validated according to International Conference on Harmonization guidelines and found to be simple, specific, accurate, precise, and robust. The mean assay percentages for atorvastatin calcium and ramipril were 99.90 and 99.55% for HPLC and 99.91 and 99.47% for HPTLC, respectively. The methods were successfully applied for the determination of atorvastatin calcium and ramipril in capsule dosage forms without any interference from common excipients.  相似文献   

19.
A rapid, simple, and highly sensitive second derivative synchronous fluorometric method has been developed for the simultaneous determination of metoclopramide (MT) and pyridoxine (PY) in a binary mixture. The method is based on measurement of the native fluorescence of these drugs at delta lambda = 80 nm in methanol. The different experimental parameters affecting the native fluorescence of the drugs were carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the ranges of 0.02-0.4 and 0.1-2 microg/mL for MT and PY, respectively. The limits of detection were 0.003 and 0.007 microg/mL and the limits of quantification were 0.008 and 0.02 microg/mL for MT and PY, respectively. The proposed method was successfully applied to the determination of MT and PY in synthetic mixtures and in commercial syrup. The results were in good agreement with those obtained with a reported method. The high sensitivity attained by the proposed method allowed the determination of MT in spiked and real human plasma samples. The mean percent recoveries of MT from spiked and real human plasma (n = 3) were 93.72 +/- 3.15 and 89.72 +/- 2.19 respectively.  相似文献   

20.
Four methods were developed for the determination of intact disopyramide phosphate in the presence of its degradation product. In the first and second methods, third-derivative spectrophotometry and first derivative of the ratio spectra were used. For the third-derivative spectrophotometric method, the peak amplitude was measured at 272 nm, while for the derivative ratio spectrophotometric method, disopyramide phosphate was determined by measuring the peak amplitude at 248 and 273 nm. Both methods were used for the determination of disopyramide phosphate in the concentration range 12.5-87.5 microg/mL, with corresponding mean recovery 100.8 +/- 0.7% for the first method and 99.9 +/- 0.7% and 99.6 +/- 0.7% for the second method at 248 and 273 nm, respectively. In the third method, an ion selective electrode (ISE) was fabricated using phosphotungstic acid as an anionic exchanger, PVC as the polymer matrix, and dibutylsebacate as a plasticizer. The ISE was used for the determination of disopyramide phosphate in pure powder form in the concentration range 10(-2)-10(-5) M. The slope was found to be 58.5 (mV/decade), and the average recovery was 99.9 +/- 1.6%. The fourth method depended on the quantitative densitometric determination of the drug in concentration range of 0.25-2.5 microg/spot using silica gel 60 F245 plates and ethyl acetate-chloroform-ammonium hydroxide (85 + 10 + 5, v/v/v) as the mobile phase, with corresponding mean accuracy of 100.3 +/- 1.1%. The 4 proposed methods were found to be specific for disopyramide phosphate in presence of up to 80% of its degradation product for the spectrophotometric methods, 90% of its degradation for the densitometric method, and 40% for the ISE method. The 4 proposed procedures were successfully applied for the determination of disopyramide phosphate in Norpace capsules. Statistical comparison between the results obtained by these methods and the official method of the drug was done, and no significant differences were found.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号