首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Summary In order to follow levels of S-Carboxymethyl-L-cysteine in biological fluids for a period as long as three half-lives after drug administration during pharmacokinetic studies, an improved method for its determination had to be developed. Like the previous one, this method uses a protein precipitation step followed by an O-Phthalaldehyde derivatization step and then an HPLC on-line clean-up. This latter was obtained by means of a switching valve system, including a Nucleosil CN 5 m (3 cm × 4.6 mm i.d.) precolumn and a Spherisorb ODS 5 m (15 cm×4.6 mm i.d.) analytical column. The sensitivity limit was improved to 0.1 g/ml in plasma samples and 0.2 g/ml in urine samples.This method was applied in studies comparing single (0.75 g) and repeated (0.75 g tid) oral administration of the drug to 30 elderly patients and 20 healthy volunteers. Results showed that the half-life was 40% longer in elderly patients than in healthy volunteers, and that area under the plasma concentration versus time curve (AUC) values in elderly patients were twice those obtained with young subjects.  相似文献   

2.
The aim of this study was to develop a technique for performing automatic static headspace analysis of volatiles without a cryogenic device. Reconcentration of solutes was accomplished using a graphitized carbon coated precolumn between two splitting points and stopping carrier gas flow during injection. Chromatographic profiles of volatile compounds from ground coffee compared with split and splitless injections provide confirmation of the good sensitivity of the technique. The analysis of a standard mixture covering a wide range of volatility confirms that the described technique might be useful to achieve enrichement of low volatile headspace compounds, even if discrimination against the various components is present.  相似文献   

3.
Summary This paper describes the direct injection analysis of the anti-cancer drug hexamethylene bisacetamide (HMBA) in biological fluids by an HPLC column switching technique. The first chromatographic column, which provides for sample extraction and cleanup, employs a micellar mobile phase with SDS as the modifier. The second column, coupled on-line to the first, utilizes reversed-phase conditions for analysis. UV detection is employed at 210 nm. 282 samples from 12 cancer patients were analysed and good pharmacokinetics curves obtained. The drug gives recoveries of 94.0–100.9% with a relative standard deviation of 1.88%. A sample analysis is completed within 15 minutes. This method should be satisfactory not only for the analysis of HMBA but also, probably for other drugs in biological fluids.  相似文献   

4.
5.
6.
Z. Yu  D. Westerlund 《Chromatographia》1998,47(5-6):299-304
Summary A new restricted access media (RAM) type of precolumn, Bio Trap 500 C18, for direct injection of plasma samples in column-switching systems was evaluated with respect to the elution of plasma proteins in different mobile phases, the loading capacity of plasma samples, the chromatographic behavior during plasma injections and protein contamination of the packing and sealings. More than 95% of plasma proteins could be excluded from the precolumn within three minutes for all selected mobile phases. Quantitative analyte recoveries could be obtained by injecting plasma samples ranging from 5 to 500 μL with the analyte mass>150 ng onto a BioTrap 500 C18 column (20×4 mm I.D.). One precolumn tolerated about 15 mL of plasma injection without out noticeable change in retention and pressure. Clogging of the precolumn was encountered (≥45 mL of plasma) due mainly to the adsorption of proteins on the packing. The performance of the analytical column (Kromasil C18) was also examined. The column efficiency decreased by 60% after processing 45 mL plasma in total.  相似文献   

7.
A direct sample injection technique was developed for supercritical fluid chromatography in a packed capillary column, with carbon dioxide as mobile phase and a flame ionization detector. The method allowed solutions, neat liquids, and even solids to be introduced as samples. Also, extraction with supercritical carbon dioxide was combined with this method to separate polymer additives.  相似文献   

8.
9.
The sequential injection (SIA) technique was applied in pharmacokinetic studies of the transporter-mediated passage of a model substrate, rhodamine 123 (Rho123), through the dually perfused rat term placenta. The method described was used for real-time monitoring of Rho123 concentrations in both the maternal and fetal compartments. Determination was processed by fluorescence detection (λex=480 nm, λem580 nm); calibration curve was linear over the range 0.01–50 μmol l−1 (r=0.99965), detection limit was 10 nmol l−1 (3σ) and RSD2% (10 readings). Transport of Rho123 was scanned under various conditions (ATP-synthesis inhibition) and several inhibitors of P-glycoprotein transporter were tested (e.g. quinidine). The advantages of the modern SIA method—an automated analytical tool providing both fast and precise analysis—were successfully demonstrated for examination of transport profiles to investigate the effect of P-glycoprotein on the placental transfer of Rho123.  相似文献   

10.
Organic acids in cerebrospinal fluid (CSF) are potential diagnostic markers for neurological diseases and metabolic disorders. A capillary electrophoretic (CE) method for the direct analysis, i.e., without any sample preparation, of six organic acids in CSF was developed. A capillary coating consisting of a triple layer of charged polymers (polybrene-dextran sulfate-polybrene) was used in combination with a negative separation voltage, providing fast and efficient analysis of acidic compounds. Separation conditions, such as background electrolyte (BGE) concentration and pH were optimized, and the influence of albumin and sodium chloride was systematically studied using a set of test compounds. With injection volumes of ca. 44 nL, plate numbers of up to ca. 150,000 were obtained with a BGE of 200 mM sodium phosphate (pH 6.0). It appeared that high sodium chloride concentrations in the sample hardly affected the peak width and shape of the organic acids, most probably due to transient isotachophoresis effects occurring in the sample zone. Adverse effects of CSF proteins, which frequently compromise the CE performance, could be effectively minimized by the triple layer coating in combination with rinses of 0.1 M hydrochloric acid. Overall, the developed CE system allowed direct injections of CSF samples, yielding good separation efficiencies and stable migration times (RSDs < 2%) for organic acids. Validation of the method with artificial and real CSF samples showed good linear responses (r > 0.99), and LODs for the organic acids were in the range of 2–8 μg/mL when applying UV detection. RSDs for migration times and peak areas were <2% and <7%, respectively. The applicability of the CE system is shown for the determination of organic acids in CSF samples.  相似文献   

11.
12.
Online combination of hydrophilic interaction chromatography (HILIC) and RP chromatography for separation of tryptic peptides is a challenging approach due to the incompatibility of direct loading HILIC fractions on the RP trapping column. High amounts of organic modifiers in loading solvents decrease the binding efficiency of tryptic peptides on C18 phases and lower the number of identifications. A 500 μL loop upfront of the trapping column filled with aqueous mobile phase was employed as a mixing chamber and enabled direct injections and improved saliva protein identification rates of HILIC fractions.  相似文献   

13.
Mass spectrometric developments in the last decade enable (sub)nanomolar detection of drug compounds in biological matrices in a few microliters of blood. However, the sampling and especially the handling of these small blood volumes is not straightforward. We studied the feasibility of a recently developed 'sorbent sampling technique' to handle these small blood volumes and the application to support pharmacokinetic (PK) screening programs. This technique applies 5-10 microL of blood on a fibrous material packed into a cartridge. Blood samples absorbed on these cartridges are eluted directly, on-line onto a solid-phase extraction liquid chromatography/tandem mass spectrometry (SPE-LC/MS/MS) system. It is shown that the sorbent sampling technique can be applied for a range of drug compounds. In spite of issues with recovery and sample clean-up that need further improvement, the sorbent sampling technique provided similar data as compared to conventional analytics. The technique was successfully applied to derive kinetic data from individual mice, thereby decreasing the number of required mice for a PK study from 21 to 3.  相似文献   

14.
A simple and robust method was developed for the routine identification and quantification of amoxicillin by micellar LC. Amoxicillin, a beta-lactamase inhibitor, is one of the most commonly prescribed drugs in the treatment of urine and skin structure infections. In this work, amoxicillin was determined in urine samples without any pretreatment step in a phenyl column using a micellar mobile phase of 0.10 M SDS and 4% butanol at pH 3. A UV detection set at 210 nm was used. Amoxicillin was eluted at 5.1 min with no interference by the protein band or endogenous compounds. Linearities (r >0.9998), intra- and interday precisions were determined (RSD (%) 0.4-2.7% and 0.3-5%, respectively, in micellar media, and 0.14-2.6% and 0.13-6%, respectively, in urine), and robustness was studied in the method validation. LOD and LOQ were 0.04 and 0.1 microg/mL in micellar media and 0.14 and 0.34 microg/mL in urine, respectively. Recoveries in the urine matrix were in the range of 95-110%. The validated method proved to be reliable and sensitive for the determination of amoxicillin in urine samples.  相似文献   

15.
Shenkang injection is a traditional Chinese formula with good curative effect on chronic renal failure. In this paper, a novel, rapid and sensitive ultra‐high‐performance liquid chromatography coupled with Q Exactive hybrid quadrupole Orbitrap high‐resolution accurate mass spectrometry was developed and validated for simultaneous determination of seven bioactive constituents of Shenkang injection in rat plasma and tissues after intravenous administration. Acetonitrile was used as a protein precipitation agent in biological samples disposal with carbamazepine as internal standard. The chromatographic separation was carried out on a C18 column with a gradient mobile phase consisting of acetonitrile and water (containing 0.1% formic acid). The MS analysis was performed in the full‐scan positive and negative ion mode. The lower limits of quantification for the seven analytes in rat plasma and tissues were 0.1–10 ng/mL. The validated method was successfully applied to tissue distribution and pharmacokinetic studies of Shenkang injection after intravenous administration. The results of the tissue distribution study showed that the high concentrations of seven constituents were primarily in the kidney tract. This is the first report of the application of Q‐Orbitrap with full‐scan mass spectrometry in tissue distribution and pharmacokinetic studies of Shenkang injection.  相似文献   

16.
This is an original report proposed a CE method for direct analysis of the underivatized amino acids using UV detection with relatively higher sensitivity, which was based on coordination interactions between amino acids and Cu (II) ions. In addition, an online sweeping preconcentration technique was easily combined to improve the detection sensitivity. Satisfying separations of the amino acids were obtained under optimized conditions: 50 mmol/L CuSO4–0.05% HAc–H2O (pH 4.5), and the separation voltage of 15 kV. The LODs for the analytes ranged from 0.1 to 0.5 μmol/L. The linearity of detection for all analytes was two orders of magnitude with the correlation coefficients greater than 0.99. The repeatability was displayed with an RSD less than 3% for migration time and peak height (n = 5). Moreover, some amino acids in real samples of human saliva and green tea were analyzed by this direct UV detection CE method with acceptable sensitivity.  相似文献   

17.
Summary A rapid and direct gas chromatographic (GC) method for determining free cholesterol in milk fat using a capillary column and programmed-temperature vaporizer-injector was assayed. It was compared with other procedures involving saponification of fat, solvent extraction of unsaponifiable matter — with and without fractionation by thin-layer chromatography — and transformation of sterols into silyl derivatives prior to GC analysis. This paper proposes an alternative to other published procedures. Repeatability of the method was assessed and the coefficient of variation determined as 2.1 %. The alternative saponification method exhibited comparable accuracy (coefficient of variation=1.8 %). Recovery ranged from 99.1 % to 105.6 %.  相似文献   

18.
对1991~2008年间各种纳米材料,包括纳米金属粒子、纳米无机材料、纳米碳材料等在蛋白质直接电化学中的应用进行了综述,引用文献58篇。  相似文献   

19.
An ionic liquid modified carbon paste electrode (CILE) was prepared with 1‐hexylpyridine hexafluorophosphate (HPPF6) and used as a substrate electrode. Then hexagonal boron nitride (BN) nanosheet, myoglobin (Mb) and Nafion were fixed on the electrode surface by coating method to get a new‐style chemically modified electrode (Nafion/Mb/BN/CILE). The morphology and crystal phase of BN nanosheet were characterized by SEM, TEM and XRD. UV‐Vis and FT‐IR results showed that Mb retained its original conformation in the composite modified film. In phosphate buffer solutions (PBS) with pH 3.0, cyclic voltammetry (CV) was performed to investigate the direct electrochemical behaviour of Mb. A pair of quasi‐reversible redox reaction peaks was obtained on the CV curve, proving that BN nanosheet had good biocompatibility and could accelerate electron transfer between Mb and electrode surface. Electrocatalytic reduction of trichloroacetic acid (TCA) was investigated, which was further applied to TCA detection. The catalytic reduction peak current at ?0.355 V depended linearly on the TCA concentration in the range of 0.2~30.0 mmol/L with the equation of Ipc (μA)=6.340 C (mmol/L)+0.305 (r=0.998), and the detection limit was 0.05 mmol/L (3 σ).  相似文献   

20.
Summary A procedure is described for the determination of the nerve agent Soman in serum. The nerve agent is separated from the serum on C18 modified silica and then eluted with benzene. The concentrated sample, to which butylacetate is added, is injected splitless into a polyethylene glycol (CP Wax 57) coated fused silica column. Solvent trapping of the analytes occurs due to the added butyl-acetate. The detection is performed with a nitrogen-phosphorus detector (NPD). The determination limit of the method is 40 pg/ml.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号