首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel analytical technique for isotopic analysis of dissolved and particulate iron (Fe) from various marine environments is presented in this paper. It combines coprecipitation of dissolved Fe (DFe) samples with Mg(OH)2, and acid digestion of particulate Fe (PFe) samples with double pass chromatographic separation. Isotopic data were obtained using a Nu Plasma MC-ICP-MS in dry plasma mode, applying a combination of standard-sample bracketing and external normalization by Cu doping. Argon interferences were determined prior to each analysis and automatically subtracted during analysis. Sample size can be varied between 200 and 600 ng of Fe per measurement and total procedural blanks are better than 10 ng of Fe. Typical external precision of replicate analyses (1S.D.) is ±0.07‰ on δ56Fe and ±0.09‰ on δ57Fe while typical internal precision of a measurement (1S.E.) is ±0.03‰ on δ56Fe and ±0.04‰ on δ57Fe. Accuracy and precision were assured by the analysis of reference material IRMM-014, an in-house pure Fe standard, an in-house rock standard, as well as by inter-laboratory comparison using a hematite standard from ETH (Zürich). The lowest amount of Fe (200 ng) at which a reliable isotopic measurement could still be performed corresponds to a DFe or PFe concentration of ∼2 nmol L−1 for a 2 L sample size. To show the versatility of the method, results are presented from contrasting environments characterized by a wide range of Fe concentrations as well as varying salt content: the Scheldt estuary, the North Sea, and Antarctic pack ice. The range of DFe and PFe concentrations encountered in this investigation falls between 2 and 2000 nmol L−1 Fe. The distinct isotopic compositions detected in these environments cover the whole range reported in previous studies of natural Fe isotopic fractionation in the marine environment, i.e. δ56Fe varies between −3.5‰ and +1.5‰. The largest fractionations were observed in environments characterized by redox changes and/or strong Fe cycling. This demonstrates the potential use of Fe isotopes as a tool to trace marine biogeochemical processes involving Fe.  相似文献   

2.
Hg concentrations in seawater are usually too low to allow direct (without pre-concentration and removal of salt matrix) measurement of its isotope ratios with multicollector-inductively coupled plasma mass spectrometry (MC-ICP-MS). Therefore, a new method for the pre-concentration of Hg from large volumes of seawater was developed. The final method allows for relatively fast (about 2.5 L h−1) and quantitative pre-concentration of Hg from seawater samples with an average Hg recovery of 98 ± 6%. Using this newly developed method we determined Hg isotope ratios in seawater. Reference seawater samples were compared to samples potentially impacted by anthropogenic activity. The results show negative mass dependent fractionation relative to the NIST 3133 Hg standard with δ202Hg values in the range from −0.50‰ to −1.50‰. In addition, positive mass independent fractionation of 200Hg was observed for samples from reference sites, while impacted sites did not show significant Δ200Hg values. Although the influence of the impacted sediments is limited to the seawater and particulate matter in very close proximity to the sediment, this observation may raise the possibility of using Δ200Hg to distinguish between samples from impacted and reference sites.  相似文献   

3.
An improved technique for precise and accurate determination of boron isotopic composition in Na-rich natural waters (groundwater, seawater) and marine biogenic carbonates was developed. This study used a ‘micro-sublimation’ technique to separate B from natural sample matrices in place of the conventional ion-exchange extraction. By adjusting analyte to appropriate pH, quantitative recovery of boron can be achieved (>98%) and the B procedural blank is limited to <8 pg. An additional mass bias effect in MC-ICP-MS was observed which could not be improved via the standard-sample-standard bracketing or the ‘pseudo internal’ normalization by Li. Therefore a standard other than NBS SRM 951 was used to monitor plasma condition in order to maintain analytical accuracy. An isotope cross-calibration with results from TIMS shows that the space-charge mass bias on MC-ICP-MS can be successfully corrected using off-line mathematical manipulation. Several reference materials, including the seawater IAPSO and two groundwater standards IAEA-B-2 and IAEA-B-3, were used to validate this approach. We found that the δ11B of the reference coral JCp-1 was 24.22 ± 0.28‰, corresponding to seawater pH based on the coral δ11B-pH function.  相似文献   

4.
A second-generation multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) was applied to lithium isotopic measurements. The high sensitivity of the ICP-MS enabled high precision (±0.82‰, 2σ) analyses with small amount of Li (∼45 ng Li). A single-step column separation protocol was established with which rapid purification of lithium from rock solutions can be carried out with reduced blank (<10 pg). The influence of potential sources of error for acquisition of lithium isotopic data introduced during the separation, such as matrix effects and isotopic fractionation due to incomplete recovery, were examined with an artificially mixed solution of a composition similar to that of basalt, which was doped with Li isotopic standard reagent. The examinations demonstrated that our protocol suffered from negligible isotopic fractionation.The Li isotopic ratios obtained by our method for seawater and standard rocks (JA-1, JB-2, and JB-3) agree well with those of previously reported data by Moriguti and Nakamura [1] and [2], which were determined using a four-step column separation method and thermal ionisation mass spectrometry (TIMS). Our separation protocol combined with a sensitive MC-ICP-MS will enable Li isotopic analyses on silicate rock with low Li contents, such as meteorite and peridotites with increased sample throughput.  相似文献   

5.
We developed an analytical method for measuring compound-specific stable carbon isotope ratios (δ13C) of phenols and nitrophenols in filter samples of particulate organic matter. The method was tested on 13 phenols derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA), together with four nonphenolic compounds. The data obtained by our method required two specific corrections for the determination of valid δ13C values: (1) for nitro compounds, the routine correction with use of m/z 46 for the contribution of 12C17O16O molecules) to m/z 45 was modified due to impact of NO2 on the m/z 46 trace, and (2) for the derivatized phenols, measured δ13C values were corrected for the shift in δ13C due to the addition of carbon atoms from the BSTFA moiety. Analysis of standard-spiked filters showed that overall there was a small compound-dependent bias in the δ13C values: the average bias ± the standard error of the mean of −0.21 ± 0.1‰ for the standard compounds tested, except 3-methylcatechol, methylhydroquinone, 4-methyl-2-nitrophenol, and 2,6-dimethyl-4-nitrophenol, whereas the average biases ± the standard errors of the mean for those were +1.2 ± 0.3‰, +1.2 ± 0.2‰, −1.2 ± 0.2‰, and −1.4 ± 0.5‰, respectively, when the injected mass of a derivatized compound exceeded 15 ngC. In situations where such small biases and uncertainties are acceptable, the method described here could be used to obtain valuable information about δ13C values. We also analyzed a real filter sample to demonstrate the practical applicability of the method.  相似文献   

6.
A new method for the determination of seawater Pb isotope compositions and concentrations was developed, which combines and optimizes previously published protocols for the separation and isotopic analysis of this element. For isotopic analysis, the procedure involves initial separation of Pb from 1 to 2 L of seawater by co-precipitation with Mg hydroxide and further purification by a two stage anion exchange procedure. The Pb isotope measurements are subsequently carried out by thermal ionization mass spectrometry using a 207Pb–204Pb double spike for correction of instrumental mass fractionation. These methods are associated with a total procedural Pb blank of 28 ± 21 pg (1sd) and typical Pb recoveries of 40–60%. The Pb concentrations are determined by isotope dilution (ID) on 50 mL of seawater, using a simplified version of above methods. Analyses of multiple aliquots of six seawater samples yield a reproducibility of about ±1 to ±10% (1sd) for Pb concentrations of between 7 and 50 pmol/kg, where precision was primarily limited by the uncertainty of the blank correction (12 ± 4 pg; 1sd). For the Pb isotope analyses, typical reproducibilities (±2sd) of 700–1500 ppm and 1000–2000 ppm were achieved for 207Pb/206Pb, 208Pb/206Pb and 206Pb/204Pb, 207Pb/204Pb, 208Pb/204Pb, respectively. These results are superior to literature data that were obtained using plasma source mass spectrometry and they are at least a factor of five more precise for ratios involving the minor 204Pb isotope. Both Pb concentration and isotope data, furthermore, show good agreement with published results for two seawater intercomparison samples of the GEOTRACES program. Finally, the new methods were applied to a seawater depth profile from the eastern South Atlantic. Both Pb contents and isotope compositions display a smooth evolution with depth, and no obvious outliers. Compared to previous Pb isotope data for seawater, the 206Pb/204Pb ratios are well correlated with 207Pb/206Pb, underlining the significant improvement achieved in the measurement of the minor 204Pb isotope.  相似文献   

7.
A new technique for the determination of suspended particulate trace metals (P-metals >0.2 μm), such as Co, Ni, Cu, Zn, Cd and Pb, in open ocean seawater has been developed by using microwave digestion coupled with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Suspended particulate matter (SPM) was collected from 500 mL of seawater on a Nuclepore filter (0.2 μm) using a closed filtration system. Both the SPM and filter were completely dissolved by microwave digestion. Reagents for the digestion were evaporated using a clean evaporation system, and the metals were redissolved in 0.8 M HNO3. The solution was diluted with buffer solution to give pH 5.0 and the metals were determined by FI-ICP-MS using a chelating adsorbent of 8-hydroxyquinoline immobilized on fluorinated metal alkoxide glass (MAF-8HQ). The procedure blanks with a filter were found to be 0.048 ± 0.008, 10.3 ± 0.3, 0.27 ± 0.05, 3.3 ± 1.8, 0.02 ± 0.03 and 0.85 ± 0.09 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively (n = 14). Detection limits defined as 3 times the standard deviation of the blanks were 0.023, 0.90, 0.14, 5.3, 0.078 and 0.28 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively. Accuracy was evaluated using certified reference materials of chlorella (NES CRM No. 3) and marine sediment (HISS-1). The method was applied to the determination of vertical distributions for P-Co, Ni, Cu, Zn, Cd and Pb in the Western North Pacific.  相似文献   

8.
A new method is described for a precise and simultaneous determination of the rate of production and dissolution of biosilica in marine waters, using isotopic dilution technique. No HF or F2 is required for chemical preparations as the change in isotopic composition is measured on silica producing SiO2 ions. The seawater sample flask is spiked with 30Si(OH)4 (<10% of increase in situ concentration) and incubated in in situ conditions. At the end of incubation, changes of the 30Si:28Si ratios in particulate and liquid phases are measured by using a thermal ionisation mass spectrometer Finnigan THQ. The relative analytical precision of the isotopic ratio measurements is <0.5%. The limit of detection of the change in isotopic ratio during incubation is 0.02 atom%. The overall repeatability determined on eight subsamples (average production: 0.23 μM day−1; average dissolution: 0.07 μM day−1) is ±0.02 and ±0.01 μM day−1 for production and dissolution, respectively. Using mass and isotopic balances of the particulate and dissolved phases in the incubation flask, the best estimates for production and dissolution rates are calculated iteratively. This method was applied to 112 samples of marine waters (production, range: 0.00-2.38 μM day−1; dissolution, range: 0.00-1.18 μM day−1).  相似文献   

9.
The study of Fe, Zn and Cd stable isotopes (δ56Fe, δ66Zn and δ114Cd) in seawater is a new field, which promises to elucidate the marine cycling of these bioactive trace metals. However, the analytical challenges posed by the low concentration of these metals in seawater has meant that previous studies have typically required large sample volumes, highly limiting data collection in the oceans. Here, we present the first simultaneous method for the determination of these three isotope systems in seawater, using Nobias PA-1 chelating resin to extract metals from seawater, purification by anion exchange chromatography, and analysis by double spike MC-ICPMS. This method is designed for use on only a single litre of seawater and has blanks of 0.3, 0.06 and <0.03 ng for Fe, Zn and Cd respectively, representing a 1–20 fold reduction in sample size and a 4–130 decrease in blank compared to previously reported methods. The procedure yields data with high precision for all three elements (typically 0.02–0.2‰; 1σ internal precision), allowing us to distinguish natural variability in the oceans, which spans 1–3‰ for all three isotope systems. Simultaneous extraction and purification of three metals makes this method ideal for high-resolution, large-scale endeavours such as the GEOTRACES program.  相似文献   

10.
This paper reports on investigations into interferences with the measurements of nanomolar nitrate + nitrite and soluble reactive phosphate (SRP) in oceanic surface seawater using a segmented continuous flow autoanalyser (SCFA) interfaced with a liquid-waveguide capillary flow-cell (LWCC). The interferences of silicate and arsenate with the analysis of SRP, the effect of sample filtration on the measurement of nanomolar nitrate + nitrite and SRP concentrations, and the stability of samples during storage are described.The investigation into the effect of arsenate (concentrations up to 100 nM) on phosphate analysis (concentrations up to 50 nM) indicated that the arsenate interference scaled linearly with phosphate concentrations, resulting in an overestimation of SRP concentrations of 4.6 ± 1.4% for an assumed arsenate concentration of 20 nM. The effect of added Si(OH)4 was to increase SRP signals by up to 36 ± 19 nM (at 100 μM Si(OH)4). However, at silicate concentrations below 1.5 μM, which are typically observed in oligotrophic surface ocean waters, the effect of silicate on the phosphate analysis was much smaller (≤0.78 ± 0.15 nM change in SRP). Since arsenate and silicate interferences vary between analytical approaches used for nanomolar SRP analysis, it is important that the interferences are systematically assessed in any newly developed analytical system.Filtration of surface seawater samples resulted in a decrease in concentration of 1.7-2.7 nM (±0.5 nM) SRP, and a small decrease in nitrate concentrations which was within the precision of the method (±0.6 nM). A stability study indicated that storage of very low concentration nutrient samples in the dark at 4 °C for less than 24 h resulted in no statistically significant changes in nutrient concentrations. Freezing unfiltered surface seawater samples from an oligotrophic ocean region resulted in a small but significant increase in the SRP concentration from 12.0 ± 1.3 nM (n = 3) to 14.7 ± 0.6 nM (n = 3) (Student's t-test; p = 0.021). The corresponding change in nitrate concentration was not significant (Student's t-test; p > 0.05).  相似文献   

11.
Takata H  Zheng J  Tagami K  Aono T  Uchida S 《Talanta》2011,85(4):1772-1777
This article describes an analytical method for the separation, preconcentration and determination of 232Th in seawater samples at sub-ng/L levels using a NOBIAS CHELATE PA1 resin and a sector field (SF) inductively coupled plasma mass spectrometer (ICP-MS). The resin showed excellent adsorption of 232Th at a low pH of 2.4 ± 0.4 in a relatively small volume (200 mL) of seawater. 232Th adsorbed on the resin was easily eluted using 5 mL of 0.8 M HNO3. An enrichment factor of 40 was achieved for 232Th analysis. Ethylenediamine-tetraacetic acid disodium salt dehydrate (EDTA) was used to investigate the effect of 232Th-binding organic ligand on the retention of 232Th on the chelating resin. Results obtained using acidified samples (pH of 2.4 ± 0.4) showed EDTA had no significant effect on 232Th recovery, indicating that at this low pH, 232Th was dissociated from the 232Th-binding organic ligand and quantitatively retained on the NOBIAS CHELATE PA1 resin. The developed analytical method was characterized by a separation and preconcentration taking approximately 4 h and a low detection limit of 0.0038 ng/L for 232Th, and was successfully applied to the determination of 232Th in seawater samples collected from coastal areas, Japan.  相似文献   

12.
A novel method, combining isotope dilution with standard additions, was developed for the analysis of eight elements (Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb) in seawater. The method requires just 12 mL of sample and employs an off-line pre-concentration step using the commercially available chelating resin Toyopearl AF-Chelate-650M prior to determination by high resolution inductively coupled plasma magnetic sector mass spectrometry (ICP-MS). Acidified samples were spiked with a multi-element standard of six isotopes (57Fe, 62Ni, 65Cu, 68Zn, 111Cd and 207Pb) enriched over natural abundance. In addition, standard additions of a mixed Co and Mn standard were performed on sub-sets of the same sample. All samples were irradiated using a low power (119 mW cm−2; 254 nm) UV system, to destroy organic ligands, before pre-concentration and extraction from the seawater matrix. Ammonium acetate was used to raise the pH of the 12 mL sub-samples (off-line) to pH 6.4 ± 0.2 prior to loading onto the chelating resin. The extracted metals were eluted using 1.0 M Q-HNO3 and determined using ICP-MS. The method was verified through the analysis of certified reference material (NASS-5) and the SAFe inter-comparison samples (S1 and D2), the results of which are in good agreement with the certified and reported consensus values. We also present vertical profiles of the eight metals taken from the Bermuda Atlantic Time Series (BATS) station collected during the GEOTRACES inter-comparison cruise in June 2008.  相似文献   

13.
A new, simple, sensitive, selective, precise and robust high-performance thin-layer chromatographic (HPTLC) method for analysis of trigonelline was developed and validated for the determination of trigonelline in herbal extracts and in pharmaceutical dosage forms. Analysis of trigonelline was performed on TLC aluminium plates pre-coated with silica gel 60F-254 as the stationary phase. Linear ascending development was carried out in twin trough glass chamber saturated with mobile phase consisting of n-propanol-methanol-water (4:1:4, v/v/v) at room temperature (25 ± 2 °C). Camag TLC scanner III was used for spectrodensitometric scanning and analysis in absorbance mode at 269 nm. The system was found to give compact spots for trigonelline (Rf value of 0.46 ± 0.02). The linear regression analysis data for the calibration plots showed good linear relationship with r2 = 0.9991 ± 0.0002 in the concentration range 100-1200 ng spot−1 with respect to peak area. According to the International Conference on Harmonization (ICH) guidelines the method was validated for precision, recovery, robustness and ruggedness. The limits of detection and quantification were determined. The trigonelline content of herbal extracts quantified and estimated from the formulation was found to be well within limits (±5% of the labeled content of the formulations). Statistical analysis of the data showed that the method is reproducible and selective for the estimation of trigonelline.  相似文献   

14.
A simple, sensitive, selective, precise and stability indicating high-performance thin-layer chromatographic method for determination of gatifloxacin both as a bulk drug and from polymeric nanoparticles was developed and validated as per the International Conference on Harmonization (ICH) guidelines. The method employed thin-layer chromatography (TLC) aluminium plates precoated with silica gel 60F-254 as the stationary phase and the mobile phase consisted of n-propanol-methanol-concentrated ammonia solution (25%) (5:1:0.9, v/v/v). This solvent system was found to give compact spots for gatifloxacin (Rf value of 0.60 ± 0.02). Densitometric analysis of gatifloxacin was carried out in the absorbance mode at 292 nm. The linear regression analysis data for the calibration plots showed good linear relationship with r = 0.9953 with respect to peak area in the concentration range of 400-1200 ng spot−1. The mean value (±S.D.) of slope and intercept were 9.66 ± 0.05 and 956.33 ± 27.67, respectively. The method was validated for precision, accuracy, ruggedness and recovery. The limits of detection and quantitation were 2.73 and 8.27 ng spot−1, respectively. Gatifloxacin was subjected to acid and alkali hydrolysis, oxidation, photodegradation and dry heat treatment. The drug undergoes degradation under acidic and basic conditions and upon wet and dry heat treatment. The degraded products were well separated from the pure drug. The statistical analysis proves that the developed method for quantification of gatifloxacin as bulk drug and from polymeric nanoparticles is reproducible and selective. As the method could effectively separate the drug from its degradation products, it can be employed as stability-indicating one.  相似文献   

15.
A new technique for stable lead (Pb) isotope extraction from seawater is established using Toyopearl AF-Chelate 650 M® resin (Tosoh Bioscience LLC). This new method is advantageous because it is semi-automated and relatively fast; in addition it introduces a relatively low blank by minimizing the volume of chemicals used in the extraction. Subsequent analyses by HR ICP-MS have a good relative external precision (2σ) of 3.5‰ for 206Pb/207Pb, while analyses by MC-ICP-MS have a better relative external precision of 0.6‰. However, Pb sample concentrations limit MC-ICP-MS analyses to 206Pb, 207Pb, and 208Pb. The method was validated by processing the common Pb isotope reference material NIST SRM-981 and several GEOTRACES intercalibration samples, followed by analyses by HR ICP-MS, all of which showed good agreement with previously reported values.  相似文献   

16.
Two liquid-phase microextraction procedures: single-drop microextraction (SDME) and dispersive liquid-liquid microextraction (DLLME), have been developed for the determination of several endocrine-disrupting phenols (EDPs) in seawaters, in combination with high-performance liquid chromatography (HPLC) with UV detection. The EDPs studied were bisphenol-A, 4-cumylphenol, 4-tertbutylphenol, 4-octylphenol and 4-n-nonylphenol. The optimized SDME method used 2.5 μL of decanol suspended at the tip of a micro-syringe immersed in 5 mL of seawater sample, and 60 min for the extraction time. The performance of the SDME is characterized for average relative recoveries of 102 ± 11%, precision values (RSD) < 9.4% (spiked level of 50 ng mL−1), and detection limits between 4 and 9 ng mL−1. The optimized DLLME method used 150 μL of a mixture acetonitrile:decanol (ratio 15.7, v/v), which is quickly added to 5 mL of seawater sample, then subjected to vortex during 4 min and centrifuged at 2000 rpm for another 5 min. The performance of the DLLME is characterized for average relative recoveries of 98.7 ± 3.7%, precision values (RSD) < 7.2% (spiked level of 20 ng mL−1), and detection limits between 0.2 and 1.6 ng mL−1. The efficiencies of both methods have also been compared with spiked real seawater samples. The DLLME method has shown to be a more efficient approach for the determination of EDPs in seawater matrices, presenting enrichment factors ranging from 123 to 275, average relative recoveries of 110 ± 11%, and precision values (RSD) < 14%, when using a real seawaters (spiked level of 3.5 ng mL−1).  相似文献   

17.
Y. Fajardo  F. Garcias  M. Casas 《Talanta》2007,71(3):1172-1179
A new automatic method for preconcentration and separation of radium in water samples has been developed. Such method combines both multisyringe (MSFIA) and multi-pumping (MPFS) flow analysis techniques allowing to analyze larger sample volumes with a higher throughput than other previous methodologies. Ra adsorbed on MnO2, deposited on cotton fiber, is eluted with hydroxylamine and subsequently coprecipitated with BaSO4. 226Ra activity is determined off-line by using a low background proportional counter. The procedure yield is (90 ± 3)% and its lower limit of detection 0.05 Bq L−1. This method has been applied satisfactorily to different types of spiked water (tap, mineral and seawater).  相似文献   

18.
Morales L  Toral MI  Alvarez MJ 《Talanta》2007,74(1):110-118
In this work, a characterization of reagent chromophere 5-(4-sulphophenylazo)-8-aminoquinoline [SPA] by IR and 1H RMN was carried out and a pKa value of 3.55 ± 0.03 was found as well. An 1:2 stoichiometry for the Cu(II)-SPA complex was determined at pH 9 by Job and molar ratio methods. A value of 1.4 × 1014 for the stability constant was also found. Based on the formation of this complex a new method for the copper determination in presence of gold and silver was developed by derivative spectrophotometry using a previous preconcentration on solid phase. In this method, the analytical measures were executed directly in the solid phase containing the complex. The Cu(II) reacts with the reagent chromophere SPA previously retained in the anionic exchange DEAE Sephadex A25. In this determination, the first derivative at 605 nm was used. The quantification range was between (3.2 ± 0.3 × 10−1) × 10−8 and (94.4 ± 0.9) × 10−8 mol L−1 (3.2 ± 0.3 × 10−1) × 10−8 , and (94.4 ± 0.9) × 10−8 mol L−1. The repeatability expressed as RSD was between 1.1 and 2.0%. The method was applied successfully for the copper determination in mineral residuals and natural water samples. The results were consistent with those provided by ICP-mass spectrometry.  相似文献   

19.

Background

Exhaled breath condensate (EBC) is a biofluid collected non invasively that, enabling the measurement of several biomarkers, has proven useful in the study of airway inflammatory diseases, including asthma, COPD and cystic fibrosis. To the best of our knowledge, there is no previous report of any analytical method to detect ADMA in EBC.

Objectives

Aim of this work was to develop an online sample trapping and enrichment system, coupled with an UPLC–MS/MS method, for simultaneous quantification of seven metabolites related to “Arginine-ADMA cycle”, using the isotopic dilution.

Methods

Butylated EBC samples were trapped in an online cartridge, washed before and after each injection with cleanup solution to remove matrix components and switched inline into the high pressure analytical column. Multiple reaction monitoring in positive mode was used for analyte quantification by tandem mass spectrometry.

Results

Validation studies were performed in EBC to examine accuracy, precision and robustness of the method. For each compound, the calibration curves showed a coefficient of correlation (r2) greater than 0.992. Accuracy (%Bias) was <3% except for NMMA and H-Arg (<20%), intra- and inter-assay precision (expressed as CV%) were within ±20% and recovery ranged from 97.1 to 102.8% for all analytes.Inter-day variability analysis on 20 EBC of adult subjects did not demonstrate any significant variation of quantitative data for each metabolite. ADMA and SDMA mean concentrations (μmol L−1), measured in EBC samples of asthmatic adolescents are significantly increased (p < 0.0001) than in normal controls (0.0040 ± 0.0021 vs. 0.0012 ± 0.0005 and 0.0020 ± 0.0015 vs. 0.0002 ± 0.0001, respectively), as well the ADMA/Tyr (0.34 ± 0.09 vs. 0.12 ± 0.02, p < 0.0001) and the SDMA/Tyr ratio (0.10 ± 0.04 vs. 0.015 ± 0.004, p < 0.0001).

Conclusions

The proposed method features simple specimen preparation, maintenance of an excellent peak shape of all metabolites and reduced matrix effects as well mass spectrometer noise. Moreover, the possibility to perform different cycles of enrichment, using large injection volumes, compensated for the low concentration of analytes contained in EBC, leading to a good analytical sensitivity. Preliminary data obtained from asthmatic and healthy adolescents, demonstrated that the analytical method applied to EBC seems suitable not only for research purposes, but also for clinical routinely analysis.  相似文献   

20.
An autonomous multi-parameter flow-through CO2 system has been developed to simultaneously measure surface seawater pH, carbon dioxide fugacity (fCO2), and total dissolved inorganic carbon (DIC). All three measurements are based on spectrophotometric determinations of solution pH at multiple wavelengths using sulfonephthalein indicators. The pH optical cell is machined from a PEEK polymer rod bearing a bore-hole with an optical pathlength of ∼15 cm. The fCO2 optical cell consists of Teflon AF 2400 (DuPont) capillary tubing sealed within the bore-hole of a PEEK rod. This Teflon AF tubing is filled with a standard indicator solution with a fixed total alkalinity, and forms a liquid core waveguide (LCW). The LCW functions as both a long pathlength (∼15 cm) optical cell and a membrane that equilibrates the internal standard solution with external seawater. fCO2 is then determined by measuring the pH of the internal solution. DIC is measured by determining the pH of standard internal solutions in equilibrium with seawater that has been acidified to convert all forms of DIC to CO2. The system runs repetitive measurement cycles with a sampling frequency of ∼7 samples (21 measurements) per hour. The system was used for underway measurements of sea surface pH, fCO2, and DIC during the CLIVAR/CO2 A16S cruise in the South Atlantic Ocean in 2005. The field precisions were evaluated to be 0.0008 units for pH, 0.9 μatm for fCO2, and 2.4 μmol kg−1 for DIC. These field precisions are close to those obtained in the laboratory. Direct comparison of our measurements and measurements obtained using established standard methods revealed that the system achieved field agreements of 0.0012 ± 0.0042 units for pH, 1.0 ± 2.5 μatm for fCO2, and 2.2 ± 6.0 μmol kg−1 for DIC. This system integrates spectrophotometric measurements of multiple CO2 parameters into a single package suitable for observations of both seawater and freshwater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号