首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An environmentally benign processing approach for furfural production from xylose and xylan under very mild conditions(353–373 K) was developed with the addition of metal chlorides in ChCl–oxalic acid(a deep eutectic solvent(DES)) synthesized from cheap and renewable starting materials). ChCl–oxalic acid acted as both a Br?nsted acid catalyst and a reaction medium in this catalytic route. In addition, a biphasic system with methyl isobutyl ketone as an extracting reagent(DES/MIBK) to further increase furfural yield was also proposed. This processing approach for producing furfural eliminated the large energy consumption for high pressure saturated steam and the generation of acidic effluent, which was very difficult to handle. The whole catalytic system was more environmentally friendly compared with the commercial process for furfural production.  相似文献   

2.
In this study, we present a new set of Henry’s constant data for the system carbon dioxide-aqueous deep eutectic solvent (DES) (20 to 80 wt% DES) at T = (303.15, 308.15, and 313.15) K. The DESs used were choline chloride-based: ethaline (choline chloride/ethylene glycol), glyceline (choline chloride/glycerol), and maline (choline chloride/malonic acid). A differential Henry’s coefficient model was used to describe the behaviour of Henry’s constant, and correlate it with temperature and concentration of DES in the aqueous DES solution. The correlation was found satisfactory such that the proposed model can be used in engineering calculations with reasonable accuracy.  相似文献   

3.
Immobilization of copper(I) ions on magnetic nanoparticles was performed using surface modification of Fe3O4 with creatine. Fe3O4@creatine-Cu(I) magnetic catalyst was synthesized and applied in C&bond;X cross-coupling reactions with aryl halides in a deep eutectic as a green solvent. The results indicate the Fe3O4@creatine-Cu(I) magnetic nanoparticles showed excellent activity and high stability. In addition, it was revealed that this catalyst can be recycled five times without significant loss in catalytic activity.  相似文献   

4.
Herein, a novel, fast, green and sensitive surfactant ion pair-switchable solvent dispersive liquid–liquid microextraction (SIP-SS-DLLME) method was developed for the preconcentration of phenazopyridine. Protonated triethylamine bicarbonate is synthesized by the reaction of triethylamine and CO2 in the presence of water. This protonated switchable solvent (soluble in water) easily converted to triethylamine which is insoluble in water. Aliquat 336 was used as an ion-pair agent in this method, which results in the increase of the phenazopyridine extraction into the switchable solvent. Variables affecting the performance of extraction were studied and optimized. The relative standard deviation (RSD) was 3.1% for five repeated determinations containing 20 µg/L of phenazopyridine. The linear range of the method for microextraction and determination of phenazopyridine was found to be 5–180 µg/L with a detection limit of 0.88 µg/L. The presented method was applied successfully for the determination of phenazopyridine in pharmaceutical and biological samples.  相似文献   

5.
Zhou  Quan  Qian  Le  Pan  Qianqian  Si  Guanqing  Qi  Zhaopeng  Zheng  Yuchuan  Li  Changjiang 《Research on Chemical Intermediates》2020,46(1):533-545
Research on Chemical Intermediates - In this paper, a novel chemosensor (named L1) for Fe3+ based on the rhodamine 6G and o-vanillin has been synthesized, which can selectively recognize Fe3+. The...  相似文献   

6.
In this study, for the first time, a deep eutectic solvent-based microwave-assisted extraction was combined with ionic liquid–based temperature controlled liquid phase microextraction for the extraction of several aflatoxins from cheese samples. Briefly, the analytes are extracted from cheese sample (3 g) into a mixture of 1.5 mL choline chloride:ethylene glycol deep eutectic solvent and 3.5 mL deionized water by exposing to microwave irradiations for 60 s at 180 W. The liquid phase was taken and mixed with 55 μL 1-hexyl-3-methylimidazolium hexafluorophosphate. By cooling the solution in the refrigerator centrifuge, a turbid state was obtained and the analytes were extracted into the ionic liquid droplets. The analytes were determined by high-performance liquid chromatography equipped with fluorescence detector. Low limits of detection (9–23 ng kg–1) and quantification (30–77 ng kg–1), high extraction recovery (66%–83%), acceptable enrichment factor (40–50), and good precision (relative standard deviations ≤ 5.2%) were obtained using the offered approach. These results reveal the high extraction capability of the method for determination of aflatoxins in the cheese samples. In this method, there was no need for organic solvents and it can be considered as green extraction method.  相似文献   

7.
In this work, a simple, inexpensive, and environmentally friendly extractive spectrophotometric method for the determination of manganese is suggested. The method is based on the formation and dispersive liquid–liquid microextraction (DLLME) of a violet-coloured ion pair of Mn(II) with 1,3,3-trimethyl-2-[3-(3-methyl-3H-benzothiazol-2-ylidene)-propenyl]-3H-indolium (BTIC) in the presence of 1-nitroso-2-naphthol (HL) as ligand, and subsequent UV-VIS spectrophotometric detection at 560?nm of the ion pair formed. The appropriate experimental conditions for the DLLME procedure were found to be: a pH of 9.5; 0.12?mmol?L?1 of BTIC; extraction solvent – toluene containing 1.75?mmol?L?1 of HL; disperser solvent – methanol; auxiliary solvent – tetrachloromethane. Beer's law is obeyed in the range 0.055–0.88 µg?mL?1 of Mn(II). The limit of detection (LOD), calculated based on three times of the standard deviation of the blank test (n?=?10), was found to be 0.004?µg?mL?1 of Mn(II). The precision (as relative standard deviation, RSD%) and accuracy (as recovery percentage, R%) of the method were examined by performing five replicate determinations at four concentration levels over two days and varied between 1.2 and 3.8, and 97.7 and 104.5, respectively. The suggested method was successfully applied to the analysis of various water samples (mineral water, spring water and drinking water).  相似文献   

8.
This work validated an automated, fast, and low solvent- consuming methodology suited for routine analysis of tributyltin (TBT) and degradation products (dibutyltin, DBT; monobutyltin, MBT) in biota samples. The method was based on the headspace solid-phase microextraction methodology (HS-SPME), coupled with gas chromatographic separation and tandem mass-spectrometry (GC–MS/MS). The effectiveness of the matrix-matched signal ratio external calibration was tested for quantification purposes. The exclusion of matrix influences in the calibration curves proved the suitability of this versatile quantification method. The method detection limits obtained were of 3 ng Sn g−1 dw for all the analytes. The analysis of references materials showed satisfying accuracy under optimum calibration conditions (% recovery between 87–111%; |Z-scores|<2). The repeatability RSD% and intra-laboratory reproducibility RSD% were lower than 9.6% and 12.6%, respectively. The work proved the remarkable analytical performances of the method and its high potential for routine application in monitoring organotin compounds (OTC).  相似文献   

9.
Journal of Solid State Electrochemistry - Electroless nickel-phosphorus plating is an important surface treatment method for copper due to its good corrosion resistance and nonmagnetic properties....  相似文献   

10.
A method to determine water content in organic solvents was developed based on the color change of cobalt(Ⅱ) nitrate in different solvents.The color-change mechanism and optimal conditions for determining the water content were investigated.The results showed that there was a good linear relationships between the absorbance of cobalt(Ⅱ) complexes in organic solvents and water contents withγin 0.9989~0.9994.This method has the advantages of low cost,good reproducibility,good sensitivity,simple in operation,fast in detection,friendly to the environment and no limitation on linear range for determining water content.It was used to determine water in samples with a satisfactory recovery in 97.81%~101.24%.  相似文献   

11.
A magnetized molecularly imprinted polymer (MIP) was prepared via a surface-imprinting technique. An allyl-based deep eutectic solvent was chosen as the functional monomer to obtain the polymer for specific recognition of lysozyme. It was deposited on silica-coated magnetite nanoparticles. The structure of the polymer was confirmed by X-ray diffraction, Fourier transform infrared spectrometry, transmission electron microscopy, thermogravimetric analysis and vibrating sample magnetometry. The maximum binding capacity of the imprinted polymer is found to be 108 mg·g?1, which is higher than that of non-imprinted polymer. Compared to reference proteins such as cytochrome C, bovine hemoglobin and bovine serum albumin, the MIP shows favorable selectivity for lysozyme. Besides, the imprinted polymer can be further used to specifically recognize lysozyme from the protein mixture and chicken egg white. Reusability studies demonstrate that the polymer can be recycled four times without significant loss of adsorption capacity. The LOD of the method is 12.8 μg·mL?1. The relative standard deviations (for n = 3) are 1.38% for precision and 2.76% for repeatability. Its facile synthesis, high adsorption performance and excellent selectivity to capture lysozyme make this polymer an attractive candidate to be applied in biomacromolecular purification.
Graphical abstract Magnetic molecularly imprinted polymer (MIP) based on deep eutectic solvent as functional monomer was fabricated and applied for the specific recognition of lysozyme. The MIP exhibits high adsorption capacity and excellent selectivity for lysozyme.
  相似文献   

12.
A novel sensitive screening method based on liquid chromatography–tandem mass spectrometry (LC–MS/MS) has shown the feasibility of separation and detection of thiodiglycolic acid in aqueous samples. The analysis of this compound is of interest since it is specific microbiological metabolite of thiodiglycol, which is precursor and degradation product of chemical warfare agent sulfur mustard. The LC–electrospray ionisation (ESI)–MS method provides a sensitive and direct approach for thiodiglycolic acid identification and quantification using non-extracted non-derivitised samples from aqueous solutions. Chromatographic separation of the thiodiglycolic acid was produced using a reverse phase LC column with gradient mobile phases consisting of 0.1% formic acid in water and acetonitrile. Identification and quantification of species were achieved using ESI–tandem MS monitoring two precursor-to-product ion transitions for thiodiglycolic acid. The method demonstrates linearity over at least two orders of magnitude and detection limit of 10 ng...mL1 in environmental water samples.  相似文献   

13.
A novel technique called miniaturized homogeneous liquid–liquid extraction (MHLLE) followed by high performance liquid chromatographic-fluorescence detection (HPLC-FL) was developed for the extraction and determination of some polycyclic aromatic hydrocarbons (PAHs) as model for analytical problem in sediment samples. The method is based on the rapid extraction of PAHs from a methanolic sample solution into 0.5 mL n-hexane, as a solvent of lower density than water. After addition of water, the extracting solvent immediately forms a distinct water-immiscible phase at the top of the vial, which can be easily separated, evaporated and re-dissolved in 25 μL of methanol and injected to the HPLC instrument. The parameters affecting the extraction process such as type and volume of organic extraction solvent, extraction time, and salt addition were investigated and the partition coefficient between methanol/water–n-hexane phases was evaluated and used to predict the extraction efficiency. Under optimal conditions, the limits of detection were estimated for the individual PAHs as 3Sb (three times of the standard deviation of baseline) of the measured chromatogram, are in the range of 0.003–0.04 ng g−1 for sediment samples. The relative recoveries of PAHs at spiking levels of 1.0 ng g−1 for sediment samples were in the range of 81–92%. The method was also applied to a corresponding standard references materials (IAEA-408) successfully. The proposed method is very fast, simple, and sensitive without any need for stirring and centrifugation.  相似文献   

14.
A multi-residue analytical method based on high-performance liquid chromatographic separation, electrospray ionization with tandem mass spectrometric detection (HPLC/MS–MS) was developed for the simultaneous analysis of 46 basic, neutral and acidic compounds covering a wide range of polarity (log KOW < 0–5.9). The compound list included selected iodinated contrast media, analgesics, anti-inflammatories, stimulants, beta-blockers, antibiotics, lipid regulators, anti-histamines, psychiatric drugs, herbicides, corrosion inhibitors and the gastric acid regulator pantoprazole. The main feature of the presented method was a simultaneous solid phase extraction (SPE) of all analytes followed by simultaneous separation and detection by HPLC/MS–MS with electrospray ionization in both positive and negative polarization within the same chromatogram. Optimization of electrospray drying gas temperature resulted in using a temperature gradient on the ion source. Six different polymeric sorbents for SPE were compared with respect to recoveries, taking into account the specific surface of each sorbent. Method quantitation limits (MQL) in surface and seawater ranged from 1.2 to 28 ng/L, in wastewater from 5.0 to 160 ng/L, respectively. In order to demonstrate the applicability of the method, river water, treated wastewater and seawater were analyzed.  相似文献   

15.
A simple and fast dispersive liquid–liquid micro-extraction (DLLME)–spectrofluorimetric technique was developed and validated for the extraction and quantification of trace amounts of Al in fish samples, where 8-hydroxyquinoline was utilized as a spectrofluorimetric probe. In order to optimize the efficacy of the DLLME technique, the impact of experimental parameters on the extraction of Al(III) from fish samples was evaluated. Under the optimal conditions, the method was linear in the concentration range of 0.1–7.0 μg/g (r = 0.9996) with a LOD of 0.092 μg/g; additionally, the method was accurate (RE% of ? 3.0 to + 10.0%), precise (RSD% of 1.2–14.3%) and robust (RSD% of 3.8 and p value of 0.21) and its recovery was in the range of 97.0 ± 3.89–110.0 ± 12.5%; moreover, samples were stable before and during the analyses. Therefore, it can be claimed that the developed method could be successfully applied for the quantification of Al in fish samples.  相似文献   

16.
Russian Journal of Physical Chemistry A - Concentrations of particles in acid–base equilibria in aqueous and nonaqueous solutions of electrolytes are calculated on the basis of logarithmic...  相似文献   

17.
In the present study, a new method for extraction and preconcentration of amoxicillin and ceftriaxone was used in hospitalised sewage samples, called vortex-assisted liquid-phase microextraction based on the solidification of deep eutectic solvent. Samples were analysed by high-performance liquid chromatography–ultraviolet detection after preparation and extraction. In this method, the new deep eutectic solvent is used as the extraction solvent, which is obtained from the combination of 1-decyl-3-methylimidazolium chloride and n-butanoic acid. The important advantages of this novel extraction solvent include material stability, low density and good freezing point near room temperature. Under the optimum conditions, enrichment factors are in the range of 164–172. Repeatability and reproducibility of the method based on seven replicate measurements of 50.0 µg L?1 of the target analytes in analysed samples were in the range of 2.1–3.5% and 3.8–5.2%, respectively. The limit of detections and linearity are in the range of 0.005–0.10 and 3–600 µg L?1, respectively. The method was successfully applied for the determination of amoxicillin and ceftriaxone in the real sewage samples. The relative recoveries of sewage samples spiked with amoxicillin and ceftriaxone are 91–107%.  相似文献   

18.
A rapid and sensitive method for the quantitative detection of busulfan (BU) in children's hemolytic samples by HPLC–tandem mass spectrometry (MS/MS) was established. In this study, the sample preparation procedure involved a one-step protein precipitation with acetonitrile (ACN) solution, and the HPLC–MS/MS method used Hypersil GOLD C18. The mobile phase consisted of 10 mM ammonium acetate solution (containing 0.1% formic acid) and ACN with a flow rate of 0.4 mL/min. Multiple reaction monitoring modes were used for quantitative analysis and the ion pairs of BU and BU-d8 were m/z 263.9 → 150.9 and 272.0 → 159.0, respectively. BU had a good linearity in the range of 0.01–10 μg mL−1. The intra- and inter-day relative error was between –7.21% and 8.26%, and the coefficient of variation was less than 12.64%. The average extraction recovery rate in plasma samples was 99.76% ± 6.53%, and the matrix in normal plasma and hemolyzed plasma had no significant effect on the detection results. Normal and hemolytic samples could maintain good stability at 4, 25 and –40°C. As a result, this method is particularly suitable for determining BU in hemolytic samples from children with hematopoietic stem cell transplantation (HSCT), and this study provides the methodological basis for further research on the pharmacokinetics of BU in children with HSCT.  相似文献   

19.
In this work, a hydrophilic task-specific ionic liquid (TSIL) of 1-chloroethyl-3-methylimidazolium chloride functionalized with 8-hydroxyquinoline was used in a dispersive liquid–liquid microextraction method followed by flame atomic absorption spectrometry for the enrichment and determination of trace amounts of cadmium (Cd2+) ions. The simultaneous chelation and extraction of Cd2+ ions was carried out by the TSIL. Fine droplets of the water-immiscible TSIL containing target analyte were generated in situ by addition of an anion exchanger potassium hexafluorophosphate (KPF6) salt to the sample tube. After phase separation by centrifugation for 4 min, the sedimented TSIL was diluted with acidified ethanol for measurement of Cd2+ content. Some significant parameters influence the preconcentration of Cd2+ ions such as sample pH, TSIL volume, amount of KPF6, non-ionic surfactant and salt concentration were investigated. Under the optimal conditions, calibration curve was linear in the range of 5–250 µg L?1 Cd2+ with correlation coefficient of 0.9975 and a detection limit of 0.55 µg L?1. The relative standard deviation for six replicate measurements of 50 µg L?1 Cd2+ was 1.5%. The method was successfully applied for the extraction and determination of Cd2+ ions in water and food samples.  相似文献   

20.
Herein we report first time choline chloride–zinc chloride based deep eutectic solvent is a green and efficient reaction medium for the [2+3] cycloaddition reaction of organic nitriles with sodium azide to afford the corresponding 5-substituted 1H-tetrazoles. The present method provides an environment-friendly route, short reaction times with excellent yields, safe process, and simple workup which make this method an attractive and useful contribution to the existing conventional processes for the synthesis of 5-substituted 1H-tetrazoles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号