首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
A selective, sensitive probe for Hg(II) ions, 7-(diethylamino)-3-methyl-2H-benzo[b][1,4] oxazine-2-thione (1), is developed. Compound 1 behaves as a ratiometric probe, exhibiting a large blue shift of 100 nm in its absorption spectra upon exposure to Hg(II) ions. The dramatic color change of the solution made ‘naked-eye’ detection of Hg(II) ions possible. Emission spectra of 1 displayed a selective enhancement in intensity in the presence of Hg(II) ions. ESI+-MS analysis indicated that Hg2+-induced desulfurization caused the large absorption response.  相似文献   

2.
Herein, a novel sensitive pseudobienzyme electrocatalytic DNA biosensor was proposed for mercury ion (Hg2+) detection by using autonomously assembled hemin/G-quadruplex DNAzyme nanowires for signal amplification. Thiol functionalized capture DNA was firstly immobilized on a nano-Au modified glass carbon electrode (GCE). In presence of Hg2+, the specific coordination between Hg2+ and T could result in the assembly of primer DNA on the electrode, which successfully triggered the HCR to form the hemin/G-quadruplex DNAzyme nanowires with substantial redox probe thionine (Thi). In the electrolyte of PBS containing NADH, the hemin/G-quadruplex nanowires firstly acted as an NADH oxidase to assist the concomitant formation of H2O2 in the presence of dissolved O2. Then, with the redox probe Thi as electron mediator, the hemin/G-quadruplex nanowires acted as an HRP-mimicking DNAzyme that quickly bioelectrocatalyzed the reduction of produced H2O2, which finally led to a dramatically amplified electrochemical signal. This method has demonstrated a high sensitivity of Hg2+ detection with the dynamic concentration range spanning from 1.0 ng L−1 to 10 mg L−1 Hg2+ and a detection limit of 0.5 ng L−1 (2.5 pM) at the 3Sblank level, and it also demonstrated excellent selectivity against other interferential metal ions.  相似文献   

3.
We report a simple and sensitive aptamer-based colorimetric detection of mercury ions (Hg2+) using unmodified gold nanoparticles as colorimetric probe. It is based on the fact that bare gold nanoparticles interact differently with short single-strand DNA and double-stranded DNA. The anti-Hg2+ aptamer is rich in thymine (T) and readily forms T–Hg2+–T configuration in the presence of Hg2+. By measuring color change or adsorption ratio, the bare gold nanoparticles can effectively differentiate the Hg2+-induced conformational change of the aptamer in the presence of a given salt with high concentration. The assay shows a linear response toward Hg2+ concentration through a five-decade range of 1 × 10−4 mol L−1 to 1 × 10−9 mol L−1. Even with the naked eye, we could identify micromolar Hg2+ concentrations within minutes. By using the spectrometric method, the detection limit was improved to the nanomolar range (0.6 nM). The assay shows excellent selectivity for Hg2+ over other metal cations including K+, Ba2+, Ni2+, Pb2+, Cu2+, Cd2+, Mg2+, Ca2+, Zn2+, Al3+, and Fe3+. The major advantages of this Hg2+ assay are its water-solubility, simplicity, low cost, visual colorimetry, and high sensitivity. This method provides a potentially useful tool for the Hg2+ detection.  相似文献   

4.
Lin YW  Liu CW  Chang HT 《Talanta》2011,84(2):324-329
We have developed a fluorescence technique for the detection of Hg2+ and Pb2+ ions using polythymine (T33)/benzothiazolium-4-quinolinium dimer derivative (TOTO-3) and polyguanine (G33)/terbium ions (Tb3+) conjugates, respectively. Hg2+ ions induce T33 to form folded structures, leading to increased fluorescence of the T33/TOTO-3 conjugates. Because Pb2+ ions compete with Tb3+ ions to form complexes with G33, the extent of formation of the G33-Tb3+ complexes decreases upon increasing the Pb2+ concentration, leading to decreased fluorescence at 545 nm when excited at 290 nm. To minimize interference from Hg2+ ions during the detection of Pb2+ ions, we conducted two-step fluorescence measurements; prior to addition of the G33/Tb3+ probe, we recorded the fluorescence of a mixture of the T33/TOTO-3 conjugates and Hg2+ ions. The fluorescence signal obtained was linear with respect to the Hg2+ concentration over the range 25.0-500 nM (R2 = 0.99); for Pb2+ ions, it was linear over the range 3.0-50 nM (R2 = 0.98). The limits of detection (at a signal-to-noise ratio of 3) for Hg2+ and Pb2+ ions were 10.0 and 1.0 nM, respectively. Relative to other techniques for the detection of Hg2+ and Pb2+ ions in soil and water samples, our present approach is simpler, faster, and more cost-effective.  相似文献   

5.
Multiplex electrochemical detection of two DNA target sequences in one sample using enzyme-functionalized Au nanoparticles (AuNPs) as catalytic labels for was proposed. This DNA sensor was fabricated using a “sandwich” detection strategy, involving two kinds of capture probes DNA immobilized on glassy carbon electrode (GCE), and hybridization with target DNA sequences, which further hybridized with the reporter DNA loaded on the AuNPs. The AuNP contained two kinds of DNA sequences, one was complementary to the target DNA, while the other was noncomplementary to the target. The noncomplementary sequences were linked with horseradish peroxidase (HRP) and alkaline phosphatase (ALP), respectively. Enhanced detection sensitivity was obtained where the AuNPs carriers increased the amount of enzyme molecules per hybridization. Electrochemical signals were generated from the enzymatic products produced from the substrates catalyzed by HRP and ALP. Under optimal conditions, a 33-mer sequence could be quantified over the ranges from 1.5 × 10−13 to 5.0 × 10−12 M with a detection limit of 1.0 × 10−13 M using HRP-AuNP as labels, and a 33-mer sequence could be quantified over the ranges from 4.5 × 10−11 M to 1.0 × 10−9 M with a detection limit of 1.2 × 10−11 M using ALP-AuNP as labels.  相似文献   

6.
In this study, we developed a fluorescence assay for the highly sensitive and selective detection of Hg2+ and Pb2+ ions using a gold nanoparticle (Au NP)-based probe. The Hg–Au and Pb–Au alloys that formed on the Au NP surfaces allowed the Au NPs to exhibit peroxidase-mimicking catalytic activity in the H2O2-mediated oxidation of Amplex UltraRed (AUR). The fluorescence of the AUR oxidation product increased upon increasing the concentration of either Hg2+ or Pb2+ ions. By controlling the pH values of 5 mM tris–acetate buffers at 7.0 and 9.0, this H2O2–AUR–Au NP probe detected Hg2+ and Pb2+ ions, respectively, both with limits of detection (signal-to-noise ratio: 3) of 4.0 nM. The fluorescence intensity of the AUR oxidation product was proportional to the concentrations of Hg2+ and Pb2+ ions over ranges 0.05–1 μM (R2 = 0.993) and 0.05–5 μM (R2 = 0.996), respectively. The H2O2–AUR–Au NP probe was highly selective for Hg2+ (>100-fold) and Pb2+ (>300-fold) ions in the presence of other tested metal ions. We validated the practicality of this simple, selective, and sensitive H2O2–AUR–Au NP probe through determination of the concentrations of Hg2+ and Pb2+ ions in a lake water sample and of Pb2+ ions in a blood sample. To the best of our knowledge, this system is the first example of Au NPs being used as enzyme-mimics for the fluorescence detection of Hg2+ and Pb2+ ions.  相似文献   

7.
Isabel López 《Talanta》2010,82(2):594-599
A fast method for mercury extraction from biological samples based on the use of HCl leaching plus different enzymatic hydrolysis (with and without mercury complexing agents), and the use of focussed ultrasounds (2-mm microtip) is here proposed. Total mercury content in several biological samples was determined by FI-ICP-MS using a carrier solution consisting of 0.1% (v/v) HCl, 0.1% (v/v) 2-mercaptoethanol, to avoid memory effect, and 0.15% (w/v) KCl. For mercury speciation a RP18 chromatographic column coupled to ICP-MS was used. A mobile phase consisting of 0.1% (v/v) formic acid, 0.1% (v/v) HFBA, 2% (v/v) methanol, and 0.02% (w/v) mM l-cysteine at pH 2.1 was used for chromatographic separation of the mercury species in the sample extracts. Extraction procedures were validated by using 50 mg of tuna fish tissue CRM-463 (2.85 ± 0.16 mg kg−1 for methylmercury). The recoveries obtained were 99 ± 3% and 93 ± 1% after acid leaching (HCl 7 M) and enzymatic extraction (15 mg protease type XIV in 2.5% (v/v) 2-mercaptoethanol), respectively. The optimal sonication conditions (5 min of exposure time and 40% of ultrasound amplitude) were applied to 5 mg of CRM-463 (88 ± 5%), 5 mg of mussel tissue (81 ± 11%) and to 2 mg of zebra fish embryos (90 ± 10%) obtaining good recoveries in all cases. Methylmecury was found to be the most abundant Hg specie in all samples. The developed method is simple and rapid (5 min sample treatment); it is suitable for very small samples and does not alter the original form of the mercury species. Thus, it is of special interest in those cases in which validation of the results may often be hampered by lack of sample availability.  相似文献   

8.
9.
A systematic analytical method is proposed and applied to directly determine the total concentration of Hg(II) and Hg(I) ions in water. Experimental results demonstrate that this method provides a low detection limit of 0.05 mM and small relative error within 1.5% in an ion concentration range of 0.2–50 mM. The technique is especially applicable for sample solutions that the traditional titration method like Volhard and EDTA complexation titrimetry could not analyze directly. This method could be employed to analyze solutions in any ratio of Hg(II) and Hg(I) ions including pure Hg(II) or pure Hg(I) ions, exhibiting several advantages, such as simple operation, good reproducibility, and low cost. Correspondence: Xin-Gui Li, Key Laboratory of Advanced Civil Engineering Materials, Institute of Materials Chemistry, College of Materials Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China.  相似文献   

10.
The present work investigates the adsorptive interactions of Hg(II) ions in aqueous medium with hydroxylated silica, aminopropylsilica and silica chemically modified by β-cyclodextrin. Batch adsorption studies were carried out with various agitation times and mercury(II) concentrations. The maximum adsorption was observed within 15–30 min of agitation. The kinetics of the interactions, tested with the model of Lagergren for pseudo-first and pseudo-second order equations, showed better agreement with first order kinetics (k1 = 3.4 ± 0.2 to 5.9 ± 0.3 min−1). The adsorption data gave good fits with Langmuir isotherms. The results have shown that β-cyclodextrin-containing adsorbent has the largest adsorption specificity to Hg(II): K L = 4125 ± 205 mmol−1. “β-cyclodextrin-NO3-” inclusion complexes with ratio 1: 1 and super molecules with composition C42H70O35 ⊎ 3 Hg(NO3)2 are formed on the surface of β-cyclodextrin-containing silica.   相似文献   

11.
Selectivity is one of the main challenges of sensors, particularly those based on chemical interactions. Multivariate analytical models can determine the concentration of analytes even in the presence of other potential interferences. In this work, we have determined the presence of mercury ions in aqueous solutions in the ppm range (0-2 mg L−1) using a ruthenium bis-thiocyanate complex as a chemical probe. Moreover, we have analyzed the mercury-containing solutions with the co-existence of higher concentrations (19.5 mg L−1) of other potential competitors such as Cd2+, Pb2+, Cu2+ and Zn2+ ions. Our experimental model is based on partial least squares (PLS) method and other techniques as genetic algorithm and statistical feature selection (SFS) that have been used to refine, beforehand, the analytical data. In summary, we have demonstrated that the root mean square error of prediction without pre-treatment and with statistical feature selection can be reduced from 10.22% to 6.27%.  相似文献   

12.
A novel and sensitive electrochemical method for determination of mercury (II) ions (Hg2+) based on the formation of thymine–Hg2+–thymine complexes and gold nanoparticle-mediated signal amplification is reported. Two 5′ end thiolated complementary oligonucleotides containing six strategically placed thymine–thymine mistakes were introduced in this work. One of the two oligonucleotides was immobilized on a gold electrode and the other one on gold nanoparticles (AuNPs). Due to six thymine–thymine mistakes the two oligonucleotides were not able to be hybridized, so AuNPs could not be immobilized onto the electrode surface after the electrode was immersed in the DNA–AuNPs solution. However, if Hg2+ existed, T–Hg2+–T complexes could be formed and AuNPs could be immobilized onto the electrode surface. Meanwhile, large numbers of [Ru(NH3)6]3+ molecules as electrochemical species could be localized onto the electrode surface. The Hg2+ detection limit of this assay could be as low as 10 nM, which is the US Environmental Protection Agency (EPA) limit of Hg2+ for drinkable water. This method is proven to be simple, convenient, high sensitive and selective.  相似文献   

13.
A rapid,sensitive,selective and reliable strip assay based on DNA-functionalized gold nanoparticles for Hg2+ detection has been developed,with a detection limit 5 nmol/L.The measurement principle was based on thymine-Hg2+-thymine(T-Hg2+-T) coordination chemistry and streptavidin-biotin interaction.The major advantages of this assay are that results can be read visually without any instrument in less than 10 min and that it does not require any sample pretreatment.  相似文献   

14.
Water-soluble l-cysteine-capped-CdS nanoparticles were prepared in aqueous solution at room temperature through a straightforward one-pot process by using safe and low-cost inorganic salts as precursors, and characterized by transmission electron microscopy, X-ray diffraction spectrometry, Fourier transform infrared spectrometry, spectrofluorometry and ultraviolet-visible spectrometry. The prepared l-cysteine-capped-CdS nanoparticles were evaluated as fluorescence probe for Hg(II) detection. The fluorescence quenching of the l-cysteine-capped-CdS nanoparticles depended on the concentration and pH of Hg(II) solution. Maximum fluorescence quenching was observed at pH 7.4 with the excitation and emission wavelengths of 360 nm and 495 nm, respectively. Quenching of its fluorescence due to Hg(II) at the 20 nmol l−1level was unaffected by the presence of 5 × 106-fold excesses of Na(I) and K(I), 5 × 105-fold excesses of Mg(II), 5 × 104-fold excesses of Ca(II), 500-fold excesses of Al(III), 91-fold excesses of Mn(II), 23.5-fold excesses of Pb(II), 25-fold excesses of Fe(III), 25-fold excesses of Ag(I), 8.5-fold excesses of Ni(II) and 5-fold excesses of Cu(II). Under optimal conditions, the quenched fluorescence intensity increased linearly with the concentration of Hg(II) ranging from 16 nmol l−1 to 112 nmol l−1. The limit of detection for Hg(II) was 2.4 nmol l−1. The developed method was applied to the detection of trace Hg(II) in aqueous solutions.  相似文献   

15.
In this work, we explored a novel fabrication method to construct Au and Ag electrodes on chip, utilizing the different solubility of gold and silver in different etching solutions. KI-I2 etching solution and 50% HNO3 were chosen to dissolve the metal layers alternatively. Planar electrodes with gold and silver could be simultaneously and accurately patterned on chip using photolithographic technique. The as-prepared electrode could be directly served as integrated three-electrode system for electrochemical measurement. Based on it, a sensing strategy has been carried out using home-made electrochemical sensing (ECS) chip, which depended on the competition of double strand DNA and Hg(II)-mediated T–T base pairs (T-Hg(II)-T). Actually, a mercury specific oligonucleotide (MSO) was immobilized onto the thus-fabricated gold working electrode and employed as the sensing element. Chronocoulometry (CC) was chosen to monitor the differences of surface charge volume and quantify the concentrations of Hg(II) ions with a low detection limit down to 1 nM. Therefore, a facile method to fabricate Au and Ag electrodes has been demonstrated to simplify the production of ECS chip. The ECS chip was finally used for constructing an effective sensing platform for sensitive Hg(II) determination, which held promising potential for designing ECS chip in lab-on-a-chip device or point-of-care diagnosis.  相似文献   

16.
ABSTRACT

In this approach, a new carbon paste electrode modified with N,N′-bis(5-bromo-2-hydroxybenzylidene)-2,2-dimethylpropane-1,3-diamine Schiff base ligand (L) was synthesised for selective and effective determination of Hg2+ ions in aqueous environmental samples using cyclic and square wave anodic stripping voltammetric methods. First, the selective detection of mercury ion was confirmed by evaluating the stability constants of metal complexes formed between the Schiff base ligand (L) and some desired cations by conductometric measurements. Afterwards, by preparing an effective carbon paste electrode modified with L, the experimental and instrumental parameters affecting the performance of modified electrode were investigated. Square wave anodic stripping voltammograms were obtained after applying an accumulation potential ?0.5 V and accumulation time 150 s in Britton–Robinson buffer solution at pH 2.0. The optimal square wave parameters found are pulse amplitude 75 mV, frequency 50 Hz and step potential 6 mV. The procedure exhibited linear range from 0.4 to 120 μg L?1 Hg2+ with a limit of detection of 0.042 μg L?1. The proposed electrode was proved to be highly selective in the presence of various cations and anions and was successfully used for determination of mercury in tobacco and several water samples.  相似文献   

17.
Improving the reproducibility of electrochemical signal remains a great challenge over the past decades. In this work, i-motif oligonucleotide probe-based electrochemical DNA (E-DNA) sensor is introduced for the first time as a regenerated sensing platform, which enhances the reproducibility of electrochemical signal, for label-free detection of glucose and urea. The addition of glucose or urea is able to activate glucose oxidase-catalyzed or urease-catalyzed reaction, inducing or destroying the formation of i-motif oligonucleotide probe. The conformational switch of oligonucleotide probe can be recorded by electrochemical impedance spectroscopy. Thus, the difference of electron transfer resistance is utilized for the quantitative determination of glucose and urea. We further demonstrate that the E-DNA sensor exhibits high selectivity, excellent stability, and remarkable regenerated ability. The human serum analysis indicates that this simple and regenerated strategy holds promising potential in future biosensing applications.  相似文献   

18.
We report a new method for the trace analysis of mercury (II) ions in water. The approach involves the use of droplet-based microfluidics combined with surface-enhanced Raman scattering (SERS) detection. This novel combination provides both fast and sensitive detection of mercury (II) ions in water. Specifically, mercury (II) ion detection is performed by using the strong affinity between gold nanoparticles and mercury (II) ions. This interaction causes a change in the SERS signal of the reporter molecule rhodamine B that is a function of mercury (II) ion concentration. To allow both reproducible and quantitative analysis, aqueous samples are encapsulated within nanoliter-sized droplets. Manipulation of such droplets through winding microchannels affords rapid and efficient mixing of the contents. Additionally, memory effects, caused by the precipitation of nanoparticle aggregates on channel walls, are removed since the aqueous droplets are completely isolated by a continuous oil phase. Quantitative analysis of mercury (II) ions was performed by calculating spectral peak area of rhodamine B at 1,647 cm−1. Using this approach, the calculated concentration limit of detection was estimated to be between 100 and 500 ppt. Compared with fluorescence-based methods for the trace analysis of mercury (II) ions, the detection sensitivities were enhanced by approximately one order of magnitude. The proposed analytical method offers a rapid and reproducible trace detection capability for mercury (II) ions in water.  相似文献   

19.
Rapid and ultrasensitive detection of trace heavy metal mercury(II) ions (Hg2+) are of significant importance due to the induced serious risks for environment and human health. This presented article reports the gold nanoparticle-based dual labeling colorimetric method (Dual-COLO) for ultrasensitive and rapid detection of Hg2+ using the specific thymine–Hg2+–thymine (T–Hg2+–T) as recognition system and the dual labeling strategy for signal amplification. Both qualitative and quantitative detections of Hg2+ are achieved successfully in aqueous samples. More importantly, the achieved detection limit of 0.005 ng mL−1 (0.025 nM) without any instruments is very competitive to other rapid detection methods even ICP-MS based methods. This Dual-COLO method is also applied directly for real water sample monitoring and, more importantly, applied in analysis of mercury poisoned animal tissues and body fluidic samples, indicating a potentially powerful and promising tool for environmental monitoring and food safety control.  相似文献   

20.
Exposure to mercury causes severe damage to various tissues and organs in humans. Concern over mercury toxicity has encouraged the development of efficient, sensitive, and selective methods for the in vivo detection of mercury. Although a variety of chemosensors have been exploited for this purpose, no in vivo monitoring systems have been described to date. In this report, we describe an irreversible rhodamine chemosensor-based, real-time monitoring system to detect mercury ions in living cells and, in particular, vertebrate organisms. The chemosensor responds rapidly, irreversibly, and stoichiometrically to mercury ions in aqueous media at room temperature. The results of experiments with mammalian cells and zebrafish show that the mercury chemosensor is cell and organism permeable and that it responds selectively to mercury ions over other metal ions. In addition, real-time monitoring of mercury-ion uptake by cells and zebrafish using this chemosensor shows that saturation of mercury-ion uptake occurs within 20-30 min in cells and organisms. Finally, accumulation of mercury ions in zebrafish tissue and organs is readily detected by using this rhodamine-based chemosensor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号