1.
Atmospheric pressure chemical ionization (APCI) was primarily applied as the ion source for liquid chromatography-mass spectrometry (LC–MS). While APCI started to be used in gas chromatography-mass spectrometry (GC–MS) in 1970s, GC-APCI-MS was not widely used until recently. As a soft ionization technique, APCI provides highly diagnostic molecular ions, which is favored for the wide-scope screening. With the capability of tandem mass spectrometry (MS/MS), GC-APCI-MS methods with high sensitivity and selectivity have been developed and applied in the analysis of persistent organic pollutants (POPs) in environment and biological samples at trace levels. The present review introduces the history of the APCI source, with emphasis on mechanisms of ionization processes under the positive and negative ionization modes. Comparison between GC-APCI-MS and GC–MS with traditional electron ionization (EI) and chemical ionization (CI) are provided and discussed for selectivity, sensitivity and stability for the analyses of POPs. Previous studies found that the GC-APCI-MS methods provided limits of detection (LODs) around 10–100 times lower than other methods. An overview of GC-APCI-MS applications is given with the discussions on the advantages and drawbacks of various analytical methods applied for the analyses of POPs.  相似文献   

2.
建立了土壤中酸性有机物的同步衍生萃取分析方法,实现了溶剂体积与土壤质量1:1萃取。将土壤、石英砂、Na4-EDTA和纯水充分混合,室温放置36 h左右使酸性有机物释放,并使水分挥发。将该状态的土壤置于衍生瓶,加入丙酮、五氟苄基溴溶液和K2CO3溶液,利用超声技术将酸性有机物的萃取和衍生同时完成,超声时间为30 min时达到最佳萃取衍生效果。萃取液用硅胶柱净化后,用气相色谱-负化学源质谱(NCI)11 min内完成检测。在5.0~250.0μg/L线性范围内,各组分线性系数r2>0.997,检出限在1.2~4.8μg/kg之间,加标回收率在66.2%~102.9%之间,相对标准偏差在8.4%~13%之间。用该技术对土壤样品分析取得满意结果。  相似文献   

3.
Phospholipids are important constituents of all living cell membranes. Lipidomics is a rapidly growing field that provides insight as to how specific phospholipids play roles in normal physiological and disease states. There are many analytical methods available for the qualitative and quantitative determination of phospholipids. This review provides a summary of the methods that were historically used such as thin layer chromatography, gas chromatography and high-performance liquid chromatography. In addition, an introduction to applications of interfacing these traditional chromatographic techniques with mass spectrometry is provided.  相似文献   

4.
Silicones have innumerable applications in many areas of life. Polydimethylsiloxane (PDMS), which belongs to the class of silicones, has been extensively used in the field of analytical chemistry owing to its favourable physicochemical properties. The use of PDMS in analytical chemistry gained importance with its application as a stationary phase in gas chromatographic separations. Since then it has been used in many sample preparation techniques such as solid phase microextraction (SPME), stir bar sorptive extraction (SBSE), thin-film extraction, permeation passive sampling, etc. Further, it is gaining importance in the manufacturing of lab-on-a-chip devices, which have revolutionized bio-analysis. Applications of devices containing PDMS and used in the field of analytical chemistry are reviewed in this paper.  相似文献   

5.
A new method of sample preparation was developed and is reported for the first time. The approach combines in-vial filtration with dispersive solid-phase extraction (d-SPE) in a fast and convenient cleanup of QuEChERS (quick, easy, cheap, effective, rugged, and safe) extracts. The method was applied to simultaneous analysis of 42 diverse pesticides and 17 environmental contaminants, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls (PCBs), and flame retardants, in shrimp as the sample matrix. Final extracts were analyzed by both low-pressure gas chromatography – triple quadrupole tandem mass spectrometry (LPGC-MS/MS), and high-performance liquid chromatography – triple quadrupole tandem mass spectrometry (HPLC-MS/MS) to provide a wide scope of analysis for targeted analytes. During method development, several different commercial sorbents for d-SPE were investigated and compared with respect to analyte recoveries. The method was validated at 10, 50, and 100 ng g−1 spiking levels (10-fold lower for PCBs), and the results for nearly all analytes were between 70 and 115% recoveries with ≤17% relative standard deviations. The method was shown to be simple, fast, and effective for multi-application analysis of chemical residues in the representative food and environmental marker matrix.  相似文献   

6.
《Arabian Journal of Chemistry》2020,13(11):8309-8337
The release of persistent organic pollutants (POPs) into the environment is an issue of global concern, as the chemicals are stable over a prolonged period resulting in their accumulation in many animals and plants. Although POPs are banned in several countries, many chemicals have been proposed as POP candidates to be added to the existing compounds as defined by the United Nations Stockholm Convention committee. To address the safe disposal and clean-up of such chemicals, new, and especially cost-effective, remediation technologies for POPs are urgently required. This review focuses on existing POPs and the types of remediation processes available for their removal. Particular attention is paid towards photocatalysis using nanocatalysts in this review, due to their effectiveness towards POP degradation, technological feasibility, and energy and cost-efficiency. The underlying principles and the key mechanisms of the photocatalysts based on TiO2 based materials, metal oxides, light-assisted Fenton systems, framework materials e.g. metal-organic frameworks and polyoxometalates, including metal-free and hybrid photocatalysts for POPs cleanup are described for advance applications in solving the POPs contamination in the environment. The improvements of photocatalytic performance especially the POPs removal mechanism using the conventional and modified process, the design and optimization of photoreactors, and the integration technology are the critical challenges for the emerging pollutants and require intensive research for the forthcoming future.  相似文献   

7.
A novel method based on the paired ion electrospray ionization (PIESI) mass spectrometry has been developed for determination of acidic pesticides at ultratrace levels in surface and ground waters. The proposed approach provides greatly enhanced sensitivity for acidic pesticides and overcomes the drawbacks of the less sensitive negative ion mode ESI-MS. The limits of detection (LODs) of 19 acidic pesticides were evaluated with four types of dicationic ion-pairing reagent (IPR) in both single ion monitoring (SIM) and selected reaction monitoring (SRM) mode. The LOD of 19 pesticides obtained with the use the optimal dicationic ion-pairing reagent ranged from 0.6 pg to 19 pg, indicating the superior sensitivity provided by this method. The transition pathways for different pesticide-IPR complexes during the collision induced dissociation (CID) were identified. To evaluate and eliminate any matrix effects and further decrease the detection limits, off-line solid-phase extraction (SPE) was performed for DI water and a river water matrix spiked with 2000 ng L−1 and 20 ng L−1 pesticides standards respectively, which showed an average percent recovery of 93%. The chromatographic separation of the acidic pesticides was conducted by high-performance liquid chromatography (HPLC) using a C18 column (250 mm × 2.1 mm) in the reversed phase mode using linear gradient elution. The optimized HPLC–PIESI-MS/MS method was utilized for determination of acidic pesticide at ng L−1 level in stream/pond water samples. This experimental approach is 1–3 orders of magnitude more sensitive for these analytes than other reported methods performed in the negative ion mode.  相似文献   

8.
9.
Flow analysis has achieved its majority as a well-established tool to solve analytical problems. Evolution of flow-based approaches has been analyzed by diverse points of view, including historical aspects, the commutation concept and the impact on analytical methodologies. In this overview, the evolution of flow analysis towards green analytical chemistry is demonstrated by comparing classical procedures implemented with different flow approaches. The potential to minimize reagent consumption and waste generation and the ability to implement processes unreliable in batch to replace toxic chemicals are also emphasized. Successful applications of greener approaches in flow analysis are also discussed, focusing on the last 10 years.  相似文献   

10.
11.
A candidate reference measurement procedure for total testosterone in human serum involving isotope dilution (ID) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The endogenous testosterone and its internal standard (testosterone-d 3) were extracted from the serum matrix using a combination of solid-phase extraction and liquid–liquid extraction prior to reversed-phase LC/MS/MS. Accuracy of the measurements was evaluated by a recovery study using testosterone-spiked serum. The recovery of the added testosterone ranged from 100.0 to 100.3%. This method was applied to the determination of testosterone in frozen serum samples from three individual donors (one female and two males) with the testosterone concentrations ranging from 0.3 to 8.5 ng g−1. Repeatability with within-set coefficients of variation (CVs) from 0.1 to 1.0% and intermediate precision with between-set CVs from 0.1 to 0.5% for both female and male serum materials were demonstrated. Excellent linearity was obtained for all linear regression lines. The detection limit at a signal-to-noise ratio of approximately 3 was 2 pg of testosterone in serum. Structural analogs as well as testosterone metabolites were tested and found to not interfere with the measurement of testosterone. This well-characterized LC/MS/MS method for serum testosterone, which demonstrates good accuracy and precision, and low susceptibility to interferences, qualifies as a reference measurement procedure that can be used to provide an accuracy base to which routine methods for testosterone can be compared and that will serve as a standard of higher order for measurement traceability.  相似文献   

12.
Mass spectrometry (MS) is the most versatile and comprehensive method in “OMICS” sciences (i.e. in proteomics, genomics, metabolomics and lipidomics). The applications of MS and tandem MS (MS/MS or MSn) provide sequence information of the full complement of biological samples in order to understand the importance of the sequences on their precise and specific functions. Nowadays, the control of polymer sequences and their accurate characterization is one of the significant challenges of current polymer science. Therefore, a similar approach can be very beneficial for characterizing and understanding the complex structures of synthetic macromolecules. MS-based strategies allow a relatively precise examination of polymeric structures (e.g. their molar mass distributions, monomer units, side chain substituents, end-group functionalities, and copolymer compositions). Moreover, tandem MS offer accurate structural information from intricate macromolecular structures; however, it produces vast amount of data to interpret. In “OMICS” sciences, the software application to interpret the obtained data has developed satisfyingly (e.g. in proteomics), because it is not possible to handle the amount of data acquired via (tandem) MS studies on the biological samples manually. It can be expected that special software tools will improve the interpretation of (tandem) MS output from the investigations of synthetic polymers as well. Eventually, the MS/MS field will also open up for polymer scientists who are not MS-specialists. In this review, we dissect the overall framework of the MS and MS/MS analysis of synthetic polymers into its key components. We discuss the fundamentals of polymer analyses as well as recent advances in the areas of tandem mass spectrometry, software developments, and the overall future perspectives on the way to polymer sequencing, one of the last Holy Grail in polymer science.  相似文献   

13.
Inductively coupled plasma mass spectrometry (ICPMS), particularly with sector field mass analyzers (SF-ICPMS), has emerged in the past several years as an excellent analytical technique for rapid, highly sensitive determination of transuranic elements (TRU) in environmental samples. SF-ICPMS has advantages of simplicity of sample preparation, high sample throughput, widespread availability in laboratories worldwide, and relatively straightforward operation when compared to other competing mass spectrometric techniques. Arguably, SF-ICPMS is the preferred technique for routine, high-throughput determination of 237Np and the Pu isotopes, excepting 238Pu, at fg-pg levels in environmental samples. Many research groups have now demonstrated the SF-ICPMS determination of 239 + 240Pu activities, 240Pu/239Pu and other Pu atom ratios in several different application areas. Many studies have examined the relative contribution of global fallout vs. local/regional Pu sources in the environment through measurement of 240Pu/239Pu and, in some cases, 241Pu/239Pu and 242Pu/239Pu. “Stratospheric fallout”, which was deposited from thermonuclear tests, conducted largely during the 1952–1964 time period, is characterized by a well-defined 240Pu/239Pu of ~ 0.18, while most other sources have different ratios. Examples of local/regional Pu sources are the Nevada Test Site, the Chernobyl plume, and accidents at Palomares, Spain and Thule, Greenland. The determination of Pu activities and atom ratios has stimulated much interest in the use of Pu as a marine tracer; several studies have shown that Pu is transported over long distances by ocean currents. 240Pu/239Pu ratios > 0.20 in sediments and seawater of the North Pacific are ascribed to ocean current transport of fallout from the Pacific Proving Ground. In nuclear forensics, much effort is focused on detection and fingerprinting of small amounts of TRU in environmental samples consisting of bulk material or individual isolated particles. Activity measurements of 239 + 240Pu, determined by SF-ICPMS, have the potential to supplement and/or replace 137Cs as a tracer of erosion, deposition, and sedimentation. Undoubtedly, the application of SF-ICPMS in TRU analysis will continue to expand, witness new developments, and generate interesting unforeseen applications in upcoming years.  相似文献   

14.
Ivano Marchi 《Talanta》2009,78(1):1-610
This review presents the state-of-the-art techniques that couple liquid chromatography (LC) and mass spectrometry (MS) via atmospheric pressure photoionization (APPI). The different ionization mechanisms are discussed as well as the influence of the mobile phase composition, the nature of the dopant, etc. A comparison with other ionization sources, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), is reported, and the combination of APPI with these sources is also discussed. Several applications, covering the time period of 2005-2008, for the analysis of drugs, lipids, natural compounds, pesticides, synthetic organics, petroleum derivatives, and other substances are presented.  相似文献   

15.
Analytical chemistry is playing an ever-increasingly important role in the global wine industry. Chemical analysis of wine is essential in ensuring product safety and conformity to regulatory laws governing the international market, as well as understanding the fundamental aspects of grape and wine production to improve manufacturing processes. Within this field, advanced instrumental analysis methods have been exploited more extensively in recent years. Important advances in instrumental analytical techniques have also found application in the wine industry. This review aims to highlight the most important developments in the field of instrumental wine and grape analysis in the African context. The focus of this overview is specifically on the application of advanced instrumental techniques, including spectroscopic and chromatographic methods. Recent developments in wine and grape analysis and their application in the African context are highlighted, and future trends are discussed in terms of their potential contribution to the industry.  相似文献   

16.
In recent years, knowledge of the different chemical forms of the elements has gained increasing importance. There has been significant progress in methods that hyphenate chromatographic separations with atomic spectrometry. These hyphenated methods can provide the most complete information on the species distribution and even structure. However, they can be lengthy, relatively costly and difficult to bring to the routine. On the other hand, it is important to remember that chromatographic techniques represent only a minor part of the separation procedures available and, in certain cases, the application of basic chemistry to sample treatments can give quantitative information about specific chemical forms. In this sense, non-chromatographic procedures can provide methods that offer sufficient information on the elemental speciation for a series of situations. Moreover, these non-chromatographic strategies can be less time consuming, more cost effective and available, and present competitive limits of detection. Thus, non-chromatographic speciation analysis continues to be a promising research area and has been applied to the development of several methodologies that facilitate this type of analytical approach. In view of their importance, the present work overviews and discusses different non-chromatographic methods as alternatives for the speciation analysis of clinical, environmental and food samples using atomic spectrometry for detection.  相似文献   

17.
A method for determination of 61 organic pollutants (polycyclic aromatic hydrocarbons and organochlorine, organophosphorous and organonitrogen pesticides) is proposed. It is based on solid phase extraction (SPE) and subsequent analysis of the extract by liquid and gas chromatography coupled to tandem mass spectrometry. Method validation yielded to the following values: limits of quantification, from 0.005 to 0.020?µg?L?1; trueness, 95% to 113% and reproducibility (as percent relative standard deviation), 2% to 15%. Additionally, the method performed well in various proficiency tests.  相似文献   

18.
Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO4. A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99Tc. Due to the extremely low concentration of 99Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99Tc are the most important issues governing the accurate determination of 99Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99Tc using solid extraction or ion exchange chromatography for separation of 99Tc, employing flow injection or sequential injection approaches are also discussed.  相似文献   

19.
In this paper, a broad overview on the applications of different carbon-based nanomaterials, including nanodiamonds, fullerenes, carbon nanotubes, graphene, carbon nanofibers, carbon nanocones-disks and nanohorns, as well as their functionalized forms, in sample preparation is provided. Particular attention has been paid to graphene because many papers regarding its application in this research field are becoming available. The distinctive properties, derivatization methods and application techniques of these materials were summarized and compared. According to their research status and perspective, these nanomaterials were classified in four groups (I: graphene and carbon nanotubes; II: carbon nanofibers; III: fullerenes; and IV: nanodiamonds, carbon nanocones/disks and carbon nanohorns) and characteristics and future trends of every group were discussed.  相似文献   

20.
During the last years (2000–2014), many publications concerning the forensic analysis of questioned documents have been published, and new techniques and methodologies are nowadays employed to overcome forensic caseworks. This article reviews a comprehensive collection of the works focused on this issue, including dating studies, the analysis of inks from pens and printers, the analysis of paper, the analysis of other samples related to questioned documents and studies on intersecting lines. These sections highlight the most relevant analytical studies by a wide range of analytical techniques. Separation and spectrometric techniques are critically discussed and compared, emphasizing the advantages and disadvantages of each one. Finally, concluding remarks on the research published are included.  相似文献   