首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid, sensitive chemiluminescent enzyme immunoassay (CLEIA) for ractopamine (RAC) based on a single-chain variable fragment (scFv)-alkaline phosphatase (AP) fusion protein was developed. The scFv gene was prepared by cloning the heavy- and light-chain variable region genes (VH and VL) from hybridoma cell line AC2, which secretes antibodies against RAC, and assembling VH and VL genes with a linker by means of splicing overlap extension polymerase chain reaction. The resulting scFv gene was inserted into the expression vector pLIP6/GN containing AP to produce the fusion protein in Escherichia coli strain BL21. The purified scFv-AP fusion protein was used to develop a direct competitive CLEIA (dcCLEIA) protocol for detection of RAC. The average concentration required for 50% inhibition of binding and the limit of detection of the assay were 0.25 ± 0.03 and 0.02 ± 0.004 ng mL−1, respectively, and the linear response range extended from 0.05 to 1.45 ng mL−1. The assay was 10 times as sensitive as the corresponding enzyme-linked immunosorbent assay based on the same fusion protein. Cross-reactivity studies showed that the fusion protein did not cross react with RAC analogs. DcCLEIA was used to analyze RAC spiked pork samples, and the validation was confirmed by high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS). The results showed a good correlation between the data of dc-CLEIA and HPLC–MS (R2 > 0.99), indicating that the assay was an efficient analytical method for monitoring food safety.  相似文献   

2.
Long-range electron transfer (ET) matrix elements (VPS), rate constants (kET) and reorganization energies for ET from phthalimide radical (pha) moiety to methyl aminoacetate radical (aa) moiety in pa–(gly)n = 0–6–aa (pa = C6H4(CO)2N–(CH2CO), gly = glycine, aa = HNCH2COOCH3) ionic molecules have been investigated using two-state variational method (TSVM) and classical rate model. Calculations on VPS reveal that the overlap between the frontier orbitals of two diabatic states is quite small, which leads to a small value of VPS. kET has a minimum at the range n = 1–3 for β-strand conformation, but linearly increases as the peptide chain length (n) increases for pro II-helix conformation. These results are in good agreement with the experimental predictions. Relevant ET mechanisms are elucidated. The transition energies for charge transfer in such systems are also calculated to test the influences of local dipoles on the potentials of the donor and acceptor. For comparison electron couplings in [pa–(gly)n = 1,3–aa]+ cations are calculated and the effects of electron correlation on inner reorganization energies in pha + pha−/+ self-exchange reactions are examined at different levels of theory respectively. Calculated results are discussed also.  相似文献   

3.
A simple, accurate and sensitive method based on headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography–tandem mass spectrometry (GC–MS/MS) was developed for the analysis of 4-ethylguaiacol, 4-ethylphenol, 4-vinylguaiacol and 4-vinylphenol in beer. The effect of the presence of CO2 in the sample on the extraction of analytes was examined. The influence on extraction efficiency of different fibre coatings, of salt addition and stirring was also evaluated. Divinylbenzene/carboxen/polydimethylsiloxane was selected as extraction fibre and was used to evaluate the influence of exposure time, extraction temperature and sample volume/total volume ratio (Vs/Vt) by means of a central composite design (CCD). The optimal conditions identified were 80 °C for extraction temperature, 55 min for extraction time and 6 mL of beer (Vs/Vt 0.30). Under optimal conditions, the proposed method showed satisfactory linearity (correlation coefficients between 0.993 and 0.999), precision (between 6.3% and 9.7%) and detection limits (lower than those previously reported for volatile phenols in beers). The method was applied successfully to the analysis of beer samples. To our knowledge, this is the first time that a HS-SPME based method has been developed to determine simultaneously these four volatile phenols in beers.  相似文献   

4.
In this work a parathion selective molecularly imprinted polymer was synthesized and applied as a high selective adsorber material for parathion extraction and determination in aqueous samples. The method was based on the sorption of parathion in the MIP according to simple batch procedure, followed by desorption by using methanol and measurement with square wave voltammetry. Plackett-Burman and Box-Behnken designs were used for optimizing the solid-phase extraction, in order to enhance the recovery percent and improve the pre-concentration factor. By using the screening design, the effect of six various factors on the extraction recovery was investigated. These factors were: pH, stirring rate (rpm), sample volume (V1), eluent volume (V2), organic solvent content of the sample (org%) and extraction time (t). The response surface design was carried out considering three main factors of (V2), (V1) and (org%) which were found to be main effects. The mathematical model for the recovery percent was obtained as a function of the mentioned main effects. Finally the main effects were adjusted according to the defined desirability function. It was found that the recovery percents more than 95% could be easily obtained by using the optimized method. By using the experimental conditions, obtained in the optimization step, the method allowed parathion selective determination in the linear dynamic range of 0.20-467.4 μg L−1, with detection limit of 49.0 ng L−1 and R.S.D. of 5.7% (n = 5). Parathion content of water samples were successfully analyzed when evaluating potentialities of the developed procedure.  相似文献   

5.
The aroylhydrazone Schiff base ligands (E)-N’-(2-hydroxybenzylidene)benzohydrazide = H2L1, (E)-N’-(2-hydroxy-3-methoxybenzylidene)benzohydrazide = H2L2 and = (E)-N’-(5-bromo-2-hydroxybenzylidene)benzohydrazide = H2L3 gave the vanadium(V)oxo-aroylhydrazone complexes [VVOL1(OCH3)(OHCH3] (1), [VVOL2(OCH3)(OHCH3]·CH3OH (2) and [VVOL3(OCH3)(OHCH3] (3) on reaction with vanadium(IV) oxide acetylacetonate. The complexes were characterized by spectroscopic methods in the solid state (IR) and in solution (UV–Vis, 1H NMR). Single crystal X-ray analysis was performed with 3. In methanol solution six-coordinated VVOL3(OCH3)(OHCH3) was formed. VIV was oxidized to Vv by aerial oxygen in the synthesis. In the VO5N coordination sphere the alcohol oxygen lies trans to the oxo oxygen. The general V–O bond length order is oxo < methoxylato < phenoxidic < enolato < alcoholic. The complexes are mononuclear, but intermolecular O–H?N hydrogen bonding affords a zigzag chain. DFT calculations on complex 3 reproduced the geometric parameters, IR and UV–Vis spectroscopic data well in a reasonable range.  相似文献   

6.
By using ionic liquid as membrane liquid and tri-n-octylphosphine oxide (TOPO) as additive, hollow fiber supported liquid phase microextraction (HF-LPME) was developed for the determination of five sulfonamides in environmental water samples by high-performance liquid chromatography with ultraviolet detection The extraction solvent and the parameters affecting the extraction enrichment factor such as the type and amount of carrier, pH and volume ratio of donor phase and acceptor phase, extraction time, salt-out effect and matrix effect were optimized. Under the optimal extraction conditions (organic liquid membrane phase: [C8MIM][PF6] with 14% TOPO (w/v); donor phase: 4 mL, pH 4.5 KH2PO4 with 2 M Na2SO4; acceptor phase: 25 μL, pH 13 NaOH; extraction time: 8 h), low detection limits (0.1–0.4 μg/L, RSD ≤ 5%) and good linear range (1–2000 ng/mL, R2 ≥ 0.999) were obtained for all the analytes. The presence of humic acid (0–25 mg/L dissolved organic carbon) and bovine serum albumin (0–100 μg/mL) had no significant effect on the extraction efficiency. Good spike recoveries over the range of 82.2–103.2% were obtained when applying the proposed method on five real environmental water samples. These results indicated that this present method was very sensitive and reliable with good repeatabilities and excellent clean-up in water samples. The proposed method confirmed hollow fiber supported ionic liquid membrane based LPME to be robust to monitoring trace levels of sulfadiazine, sulfamerazine, sulfamethazine, sulfadimethoxine and sulfamethoxazole in aqueous samples.  相似文献   

7.
Organic dyes that consist of a [2.2]paracyclophane moiety between a triphenylamine donor group and a cyanoacrylic acid acceptor group have exhibited considerably high values of open-circuit voltage (Voc) in the range of 0.69–0.74 V. In an experiment that involved using an ion liquid electrolyte (E2 electrolyte), the values of Voc were increased to 0.03–0.04 V because of a decrease in the concentration of LiI. A typical device demonstrated a maximal incident photon-to-current conversion efficiency (IPCE) of 60% in the region of 350–475 nm, a short-circuit photo current density (Jsc) of 8.80 mA cm−2, an open-circuit photovoltage (Voc) of 0.74 V, and a fill factor (FF) of 0.65, corresponding to an overall conversion efficiency of 4.24% of CPG2b. The photophysical properties were analyzed using a time-dependent density functional theory (TDDFT) model with the M062X functional.  相似文献   

8.
In this communication, the first nonelectrocatalysis-type hydrogen peroxide electrochemical sensor is reported. The electroactive iron(III) diethylenetriaminepentaacetic acid (DTPA-FeIII) complex is immobilized on the cysteamine (cys) modified nanoporous gold (NPG) films by covalent method. The immobilized DTPA-FeIII complex quickly communicates an electron with the electrode. Upon addition of hydrogen peroxide, however, hydrogen peroxide inhibits the direct electron transfer of the DTPA-FeIII complex due to the generation of nonelectroactive DTPA-FeIII–H2O2 complex. Based on quenching mechanism, the first hydrogen peroxide electrochemical sensor based on a nonelectrocatalytic mechanism is developed. The novel hydrogen peroxide electrochemical sensor has the ultralow detection limit (1.0 × 10–14 M) and wide linear range (1.0 × 10–13 to 1.0 × 10–8 M) with excellent reproducibility and stability.  相似文献   

9.
Liming Wei  Pengyuan Yang 《Talanta》2010,80(3):1298-1151
Immobilization of enzyme on detonation nanodiamond (dND, 3-10 nm) and its application for efficient proteolysis have been demonstrated. By evaluation of the Michaelis constant (Km) and maximum velocity (Vmax) of immobilized enzyme, its activity was not impaired significantly by immobilization. And enzyme immobilized on dNDs exhibited much better thermal and chemical stabilities than its free counterpart and maintained high activity even after 10 times reuse. The efficient proteolysis by trypsin immobilized on dNDs (dND-trypsin) is demonstrated with the digestion of myoglobin (or other model protein) in a short time (5 min). Large numbers of identified peptides obtained by dNDs-trypsin enable a higher degree of sequence coverage and more positive identification of proteins than those obtained by in-solution digestion and the commercial immobilized trypsin beads, respectively. Moreover, immobilization of peptide-N-glycosidase F (PNGase F) on dNDs was realized and resulted in faster sequential glycosidase digestion of glycopeptides in less than 10 min.  相似文献   

10.
A new method for uric acid (UA) determination based on the quenching of the cathodic ECL of the tris(2,2-bipyridine)ruthenium(II)–uricase system is described. The biosensor is based on a double-layer design containing first tris(2,2-bipyridine)ruthenium(II) (Ru(bpy)32+) electrochemically immobilized on graphite screen-printed cells and uricase in chitosan as a second layer. The uric acid biosensing is based on the ECL quenching produced by uric acid over the cathodic ECL caused by immobilized Ru(bpy)32+ in the presence of uricase. The use of a −1.1 V pulse for 1 s with a dwelling time of 10 s makes it possible to estimate the initial enzymatic rate, which is used as the analytical signal. The Stern–Volmer type calibration function shows a dynamic range from 1.0 × 10−5 to 1.0 × 10−3 M with a limit of detection of 3.1 × 10−6 M and an accuracy of 13.6% (1.0 × 10−4 M, n = 5) as relative standard deviation. Satisfactory results were obtained for urine samples, creating an affordable alternative for uric acid determination.  相似文献   

11.
RF sputtered p-type nickel oxide (NiO) thin film exhibiting tunable semiconductor character which in turns enhanced its functional properties. NiO thin film with high hole mobility is developed as a potential matrix for the realization of glucose biosensor. NiO thin film prepared under the optimized deposition conditions offer good electrical conductivity (1.5 × 10−3 Ω−1-cm−1) with high hole mobility (2.8 cm2 V−1 s−1). The bioelectrode (GOx/NiO/ITO/glass) exhibits a low value of Michaelis–Menten constant (Km = 1.05 mM), indicating high affinity of the immobilized GOx toward the analyte (glucose). Due to the high surface coverage (2.32 × 10−7 mol cm−2) of the immobilized enzyme on to the NiO matrix and its high electrocatalytic activity, the prepared biosensor exhibits a high sensitivity of 0.1 mA (mM−1-cm−2) and a good linearity from 25 to 300 mg dL−1 of glucose concentration with fast response time of 5 s. Various functional properties of the material (mobility, crystallinity and stress) are found to influence the charge communication feature of NiO thin film matrix to a great extent, resulting in enhanced sensing response characteristics.  相似文献   

12.
A simple, precise, and accurate hydrophilic interaction liquid chromatographic (HILIC) method has been developed for the determination of five aromatic amines in environmental water samples. Chromatography was carried out on a bare silica column, using a mixture of acetonitrile and a buffer of NaH2PO4–H3PO4 (pH 1.5, containing 10 mM NaH2PO4) (85:15, v/v) as a mobile phase at a flow rate of 1 mL min−1. Aromatic amines were detected by UV absorbance at 254 nm. The linear range of amines was good (r2 > 0.998) and limit of detection (LOD) within 0.02–0.2 mg L−1 (S/N = 3). The retention mechanism for the analytes under the optimum conditions was determined to be a combination of adsorption, partition and ionic interactions. The proposed method was applied to the environmental water samples. Aromatic amines were isolated from aqueous samples using solid-phase extraction (SPE) with Oasis HLB cartridges. Recoveries of greater than 75% with precision (RSD) less than 12% were obtained at amine concentrations of 5–50 μg L−1 from 100 mL river water and influents from a wastewater treatment plant (WWTP). The present HILIC technique proved to be a viable method for the analysis of aromatic amines in the environmental water samples.  相似文献   

13.
The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption–desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30–60 μm), a specific surface area (SBET) of 281.26 m2 g−1 and a total pore volume (Vt) of 0.459 cm3 g−1. Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2–2.2 ng mL−1. The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL−1 for each BP) were in the range of 81.3–106.7% with RSD values below 8.3%.  相似文献   

14.
The reason why a moving reaction boundary (MRB) can stack analyte in highly saline sample in capillary electrophoresis [C.X. Cao, Y.Z. He, M. Li, Y.T. Qian, S.L. Zhou, L. Yang, Q.S. Qu, Anal. Chem. 74 (2002) 4167] is still unclear. To illuminate the mechanism of such stacking, three MRBs formed by formic acid-NaOH buffer and sodium formate as well as 40, 80 and 120 mmol/L sodium chloride in matrixes were studied. The computation with MRB theory shows that sodium chloride in matrix has weak effect on the stacking efficiency, whether the concentration of sodium chloride is set at 40, or 80, or 120 mmol/L. The conclusion has been highly manifested by numerous experiments. Furthermore, the computer simulation and theoretical analyses depict that this kind of stacking is induced by the mechanism of MRB, rather than that of electrostacking or isotachophoresis (ITP) under the given electrolytic system. Finally, the application of the sample condensation was achieved for the stacking of analyte(s) in highly saline biological sample of skeletonema costarum’ culture with up to 527 mmol/L total salt and health human urine with 150-320 mmol/L inorganic ions (Cl, Na+, K+, PO43−, etc.). The results herein have a clear significance to the design on stacking of analyte in highly saline biological sample.  相似文献   

15.
An extracting medium based on chitosan–polypyrrole (CS–PPy) magnetic nanocomposite was synthesized by chemical polymerization of pyrrole at the presence of chitosan magnetic nanoparticles (CS-MNPs) for micro-solid phase extraction. In this work, magnetic nanoparticles, the modified CS-MNPs and different types of CS–PPy magnetic nanocomposites were synthesized. Extraction efficiency of the CS–PPy magnetic nanocomposite was compared with the CS-MNPs and Fe3O4 nanoparticles for the determination of naproxen in aqueous samples, via quantification by spectrofluorimetry. The scanning electron microscopy images obtained from all the prepared nanocomposites revealed that the CS–PPy magnetic nanocomposite possess more porous structure. Among different synthesized magnetic nanocomposites, CS–PPy magnetic nanocomposite showed a prominent efficiency. Influencing parameters on the morphology of CS–PPy magnetic nanocomposite such as weight ratio of components was also assayed. In addition, effects of different parameters influencing the extraction efficiency of naproxen including desorption solvent, desorption time, amount of sorbent, ionic strength, sample pH and extraction time were investigated and optimized. Under the optimum condition, a linear calibration curve in the range of 0.04–10 μg mL−1 (R2 = 0.9996) was obtained. The limits of detection (3Sb) and limits of quantification (10Sb) of the method were 0.015 and 0.04 μg mL−1 (n = 3), respectively. The relative standard deviation for water sample spiked with 0.1 μg mL−1 of naproxen was 3% (n = 5) and the absolute recovery was 92%. The applicability of method was extended to the determination of naproxen in tap water, human urine and plasma samples. The relative recovery percentages for these samples were in the range of 56–99%.  相似文献   

16.
This work reports the study of the kinetics of zinc recovery from spent pickling solutions by means of emulsion pertraction technology (EPT) in order to reuse the metal in electrolytic processes. Tributyl phosphate (TBP) and service water were used as extraction (EX) and back-extraction (BEX) agents, respectively. Kinetic experiments were carried out in hollow fiber membrane contactors in order to analyse the influence of several operation variables on the rate of zinc recovery. A mathematical model that considers the mass transfer resistance shared between the organic liquid membrane and the organic phase boundary layer was developed; the mass transfer coefficients were estimated by means of the parameter estimation tool ASPEN CUSTOM MODELER (from ASPENTECH) to obtain the values km = 2.68 × 10−7 m/s and AVko = 0.0125 s−1. Simulated results agreed satisfactorily well with experimental data. Consequently, the kinetic model and parameters were confirmed. Finally, a comparison between EPT and non-dispersive solvent extraction (NDSX) was carried out in order to evaluate the advantages and disadvantages of both membrane configurations.  相似文献   

17.
For any particular fluid, the set of three critical constants (CC) – pressure Pc, temperature Tc and molar volume Vc – has a central importance in defining the physical behaviour of the fluid in the gas and liquid states. However, little attention seems to have been paid in the past to the relations between the CC of different substances. In the present paper, some simple and apparently novel relations have been found between the three CC for the set of four noble gases: Ne, Ar, Kr, Xe. Defining the critical quotient Qc ≡ RTc/Pc (where R is the Gas Constant) the correlations may be summarised by the dual equation: (Vc/cm3 mol−1) = 27 + 0.31 (Tc/K) = 3.3 + 0.280 (Qc/cm3 mol−1), which describes the CC data for the quartet Ne–Xe with an average uncertainty of 0.5%. Regarding the other two noble gases, the two isotopes of the lightest member, 3He and 4He, show the deviations from these relations that are expected from quantal effects and their low molar masses; while for the heaviest member, Rn, the correlations enable a value of 145(5) cm3 mol−1 to be estimated for Vc that is not otherwise well defined in the literature. By contrast, and contrary to the general assumption, the second lightest member, Ne, apparently does not show appreciable quantal effects in the area, so that Ne–Xe may be considered together as a group. These correlations are compared with the behaviour of a selection of polyatomic fluids; in these comparisons, the NG dual correlation equation provides a reference line defining the presumed simplest behaviour. This and related areas show a “Residual Volume Effect”, in that extrapolating the equivalent temperature and energy parameters to zero for the state of zero-mass point particles, referred to here as the hypothetical element zeronium (Ze), the system in each case still has a finite intercept; this intercept amounts to essentially 34% of the average volume for the present quartet Ne–Xe, rather than the zero volume expected for this condition.  相似文献   

18.
Electrochemical paper-based analytical devices (ePADs) with integrated plasma isolation for determination of glucose from whole blood samples have been developed. A dumbbell shaped ePAD containing two blood separation zones (VF2 membranes) with a middle detection zone was fabricated using the wax dipping method. The dumbbell shaped device was designed to separate plasma while generating homogeneous flow to the middle detection zone of the ePAD. The proposed ePADs work with whole blood samples with 24–60% hematocrit without dilution, and the plasma was completely separated within 4 min. Glucose in isolated plasma separated was detected using glucose oxidase immobilized on the middle of the paper device. The hydrogen peroxide generated from the reaction between glucose and the enzyme pass through to a Prussian blue modified screen printed electrode (PB-SPEs). The currents measured using chronoamperometry at the optimal detection potential for H2O2 (−0.1 V versus Ag/AgCl reference electrode) were proportional to glucose concentrations in the whole blood. The linear range for glucose assay was in the range 0–33.1 mM (r2 = 0.987). The coefficients of variation (CVs) of currents were 6.5%, 9.0% and 8.0% when assay whole blood sample containing glucose concentration at 3.4, 6.3, and 15.6 mM, respectively. Because each sample displayed intra-individual variation of electrochemical signal, glucose assay in whole blood samples were measured using the standard addition method. Results demonstrate that the ePAD glucose assay was not significantly different from the spectrophotometric method (p = 0.376, paired sample t-test, n = 10).  相似文献   

19.
A novel and efficient digestion method based on choline chloride–oxalic acid (ChCl–Ox) deep eutectic solvent (DES) was developed for flame atomic absorption spectrometry (FAAS) determination of Cu, Zn, and Fe in biological fish samples. Key parameters that influence analyte recovery were investigated and optimized, using the fish protein certified reference material (CRM, DORM-3) throughout the procedure. In this method, 100 mg of the sample was dissolved in ChCl–Ox (1:2, molar ratio) at 100 °C for 45 min. Then, 5.0 mL HNO3 (1.0 M) was added. After centrifugation, the supernatant solution was filtered, diluted to a known volume, and analyzed by FAAS. Under optimized conditions, an excellent agreement between the obtained results and the certified values was observed, using Student's t-test (P = 0.05); the extraction recovery of the all elements was greater than 95.3%. The proposed method was successfully applied to the determination of analytes in different tissues (muscle, liver, and gills) having a broad concentration range in a marine fish sample. The reproducibility of the method was validated by analyzing all samples by our method in a different laboratory, using inductively coupled plasma optical emission spectrometry (ICP-OES). For comparison, a conventional acid digestion (CAD) method was also used for the determination of analytes in all studied samples. The simplicity of the proposed experimental procedure, high extraction efficiency, short analysis time, lack of concentrated acids and oxidizing agents, and the use of safe and inexpensive components demonstrate the high potential of ChCl–Ox (1:2) for routine trace metal analysis in biological samples.  相似文献   

20.
Tyrosinase from a plant source Amorphophallus companulatus was immobilized on eggshell membrane using glutaraldehyde. Among the three different approaches used for immobilization, activation of eggshell membrane by glutaraldehyde followed by enzyme adsorption on activated support could stabilize the enzyme tyrosinase and was found to be effective. Km and Vmax values for dopamine hydrochloride calculated from Lineweaver-Burk plot were 0.67 mM and 0.08 mM min−1, respectively. Studies on effect of pH showed retention of more than 90% activity over a pH range 5.0-6.5. Membrane bound enzyme exhibited consistent activity in the temperature range 20-45 °C. Shelf life of immobilized tyrosinase system was found to be more than 6 months when stored in phosphate buffer at 4 °C. An electrochemical biosensor for dopamine was developed by mounting the tyrosinase immobilized eggshell membrane on the surface of glassy carbon electrode. Dopamine concentrations were determined by the direct reduction of biocatalytically liberated quinone species at −0.19 V versus Ag/AgCl (3 M KCl). Linearity was observed within the range of 50-250 μM with a detection limit of 25 μM.  相似文献   