首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
This work describes chromatographic properties of reversed-phase/cation-exchange/anion-exchange trimodal stationary phases. These stationary phases were based on high-purity porous spherical silica particles coated with nano-polymer beads using an electrostatically driven self-assembly process. The inner-pore area of the material was modified covalently with an organic layer that provided both reversed-phase and anion-exchange properties while the outer surface was coated with nano-sized polymer beads with strong cation-exchange characteristics. This design ensured spatial separation of the anion-exchange and the cation-exchange regions, and allowed reversed-phase, anion-exchange and cation-exchange retention mechanisms to function simultaneously. Chromatographic evaluation of ions and small molecules suggested that retention of ionic analytes was influenced by the ionic strength, pH, and mobile phase organic solvent content, and governed by both ion-exchange and hydrophobic interactions. Meanwhile, neutral analytes were retained by hydrophobic interaction and was mainly affected by mobile phase organic solvent content. Depending on the specific application, selectivity could be optimized by adjusting the anion-exchange/cation-exchange capacity ratio (selectivity), which was achieved experimentally by using porous silica particles with different surface areas.  相似文献   

2.
This work describes the use of mixed-mode stationary phases which exhibit both strong ion-exchange (either cation-exchange, SCX, or anion-exchange, SAX) and reversed-phase chromatographic characteristics in capillary electrochromatographic separations of pyrimidine derivatives. Different packing materials, namely C6, SCX/C6 and SAX/C6, were compared and the influence of the composition of the carrier electrolyte (concentration of acetonitrile and pH) on the retention behavior of the selected solutes was investigated. A separation of all eight pyrimidine derivatives could be obtained on a 6.5 cm column packed with the SAX/C6 stationary phase in less than 3 min, with good peak shapes and efficiencies in the range 39,000 to 81,000 plates per meter.  相似文献   

3.
This work describes the separation of basic aromatic compounds by capillary electrochromatography employing acidic carrier electrolytes and bare silica as well as strong cation-exchange stationary phases. A mixed-mode separation mechanism was involved, comprising chromatographic interactions (adsorption, ion-exchange) as well as electrophoretic migration. The influence of ion-exchange on the retention/migration of the solutes could be manipulated according to procedures commonly employed in ion chromatography. These include variations of the eluting strength and/or the concentration of the competing ion present in the background electrolyte. Using this approach, separation times could be shortened and changes in selectivity could be achieved for a number of analytes.  相似文献   

4.
Summary An ion chromatographic method has been developed for the separation of Te (IV) and Se(IV) in hydrochloric acid mobile phases; the method has been used to determine tellurium in a high-purity non-stoichiometric semiconducting ZnCdTe-based material. Different cation-exchange columns (IonPac CS2, CS3, CS10), a mixed bed ion-exchange column (IonPac CS5), a multi-mode cation-exchange column (OmniPac PCX-500), anion-exchange columns (IonPac AS4, AS4A, AS5, AS5A, AS10, AS11) and a multi-mode anion-exchange column (OmniPac PAX-500) were evaluated for ion chromatographic separation of Se and Te and to study the chemical forms in which the analytes were eluted. The chromatographic data obtained enabled the calculation of both the sign and the chaarge of the eluting species.  相似文献   

5.
The effect of treatment of porous graphitic carbon (PGC) stationary phases with hydrogen peroxide and with sodium sulfite on the retention behavior of analyte compounds has been investigated using benzene, aromatic sulfonate ions, and benzyltrialkylammonium ions as model compounds. It is shown that the retention times of the cationic analytes are increased by treating the PGC column with the reducing agent, while decreased by treating it with the oxidizing agent. On the other hand, the retention times of the anionic analytes are decreased by treating the column with the reducing agent, while increased by treating it with the oxidizing agent. The effect of the redox treatment on the retention of benzene is negligibly small. The investigation of the ion-exchange property of the PGC packings have shown that PGC has anion-exchange property and the anion-exchange capacity is decreased by treating PGC with the reducing agent, whereas it is increased by treatment with the oxidizing agent. This means that the modification of the retention selectivity of the PGC stationary phases with redox treatment can be interpreted in terms of the change of the surface charge. The mechanism of chemical modification of the PGC stationary phase with redox treatment is discussed on the basis of the experimental results obtained on the ion-exchange capacity and the redox activity.  相似文献   

6.
Three n-octadecylphosphonic acid-modified magnesia-zirconia reversed stationary phases (C18PZM) are prepared via the strong Lewis base interactions between organophosphonate and magnesia-zirconia composite. And two of them are end-capped by using trimethylchlorosilane as end-capping agent in different procedures. Stability studies at extreme high pH conditions (pH 9-12) show that both the non-endcapped and endcapped columns are quite stable at pH 12 mobile phase. The reversed-phase liquid chromatographic behavior of three C18PZM stationary phases are comparatively investigated in detail using a variety of basic compounds as probes. The retention of basic compounds on the three phases is studied over a wide range of pHs. And the possible retention mechanisms of basic compounds on the three stationary phases are discussed. The results show that the basic solutes retain by a hydrophobic and cation-exchange interaction mixed mechanism on three stationary phases when they are operated in eluents at pH values near to the pKa of the Brönsted conjugate acid form of the analyte, suggesting that inherent zirconol groups on ZM are not expected to interact with bases via cation-exchange interaction at lower pH. Nonetheless, the non-endcapped phase differs markedly from the edncapped ones in retention and selectivity of basic solutes using eluents at pH 4.1, implying a complex retention mechanism at this pH. The cation-exchange sites under such conditions are more likely due to the adsorbed Lewis base anionic buffer constituents (acetate) on accessible ZM surface sites than the chemisorbed phosphonate. Although the three phases exhibit very similar chromatographic behavior with eluents at pH 10.1, and show in general satisfactory separation of basic compounds and alkaloids studied, the performance for a specific analyte, however, differs largely from column to column.  相似文献   

7.
There has recently been increased interest in coupling ion chromatography (IC) to high resolution mass spectrometry (HRMS) to enable highly sensitive and selective analysis. Herein, the first comprehensive study focusing on the direct coupling of suppressed IC to HRMS without the need for post-suppressor organic solvent modification is presented. Chromatographic selectivity and added HRMS sensitivity offered by organic solvent-modified IC eluents on a modern hyper-crosslinked polymeric anion-exchange resin (IonPac AS18) are shown using isocratic eluents containing 5–50 mM hydroxide with 0–80% methanol or acetonitrile for a range of low molecular weight anions (<165 Da). Comprehensive experiments on IC thermodynamics over a temperature range between 20–45 °C with the eluent containing up to 60% of acetonitrile or methanol revealed markedly different retention behaviour and selectivity for the selected analytes on the same polymer based ion-exchange resin. Optimised sensitivity with HRMS was achieved with as low as 30–40% organic eluent content. Analytical performance characteristics are presented and compared with other IC-MS based works. This study also presents the first application of IC-HRMS to forensic detection of trace low-order anionic explosive residues in latent human fingermarks.  相似文献   

8.
A novel stationary phase prepared by the thermal immobilization of poly(dimethylsiloxane) onto the surface of silica (PDMS–SiO2) has been described, evaluated and compared with 229 commercially available RP-LC stationary phases using the Tanaka column classification protocol. The phase exhibited many unique chromatographic properties and, based on the phases in the database, was most similar to the fluoroalkylated phases (aside from the obvious lack of fluoro selectivity imposed by the C–F dipole). The phase exhibited classic reversed-phase behaviour in acid mobile phase conditions and mixed-mode reversed-phase/cation-exchange retention behaviour in neutral mobile phase conditions. The phase exhibited acceptable stability at both low and intermediate pH, conditions which should impart optimum chromatographic selectivity to the phase. Retention of basic analytes was shown to occur by a “three site model” as proposed by Neue. This new PDMS–SiO2 stationary phase is extremely interesting in that the dominancy of its hydrophobic and ion-exchange interactions can be controlled by the influence of mobile phase pH, buffer type and concentration. The PDMS–SiO2 stationary phase may provide a complementary tool to reversed-phase and HILIC stationary phases. The present results highlight the fact that the type of buffer, its concentration and pH can not only affect peak shape but also retention, selectivity and hence chromatographic resolution. Therefore, in method development and optimization strategies it is suggested that more emphasis should be given to the evaluation of these mobile phase operating parameters especially when basic solutes are involved.  相似文献   

9.
The potential of methacrylate-based mixed-mode monolithic stationary phases bearing sulfonic acid groups for the separation of positively charged analytes (alkylanilines, amino acids, and peptides) by capillary electrochromatography (CEC) is investigated. The retention mechanism of protonated alkylanilines as positively charged model solutes on these negatively charged mixed-mode stationary phases is investigated by studying the influence of mobile phase and stationary phase parameters on the corrected retention factor which was calculated by taking the electrophoretic mobility of the solutes into consideration. It is shown that both solvophobic and ion-exchange interactions contribute to the retention of these analytes. The dependence of the corrected retention factor on (1) the concentration of the counter ion ammonium and (2) the number of methylene groups in the alkyl chain of the model analytes investigated shows clearly that a one-site model (solvophobic and ion-exchange interactions take place simultaneously at a single type of site) has to be taken to describe the retention behaviour observed. Comparison of the CEC separation of these charged analytes with electrophoretic mobilities determined by open-tubular capillary electrophoresis shows that mainly chromatographic interactions (solvophobic and ion-exchange interactions) are responsible for the selectivity observed in CEC, while the electrophoretic migration of these analytes plays only a minor role.  相似文献   

10.
Capillary-channeled polymer (C-CP) fibers extruded from nylon-6 are used as the stationary phase for the ion-exchange/reversed-phase mixed-mode chromatographic separation of a three protein mixture. The nylon-6 C-CP fibers are packed collinearly in a 250 x 1.5-mm i.d. column with an interstitial fraction of approximately 0.6. The effects of four displacing salts at three different pHs are studied with regards to protein retention time, peak width, selectivity, and resolution for a synthetic mixture consisting of myoglobin, ribonuclease A, and lysozyme to determine the optimum mobile phase conditions. The net charge model is found to be inadequate in fully explaining the retention behavior, as the proteins are retained by anion and cation-exchange interactions, as well as hydrophobic interactions with the stationary phase. It is found that pH and displacing salt strength had a significant influence on the retention properties and resolution of the proteins.  相似文献   

11.
This work describes the separation of acidic, basic and neutral organic compounds as well as inorganic anions in a single run by capillary electrochromatography employing a stationary phase which exhibits both strong anion-exchange and reversed-phase chromatographic characteristics. The positive surface charge of this stationary phase provided a substantial anodic electroosmotic flow. The analytes were separated by a mixed-mode mechanism which comprised chromatographic interactions (hydrophobic interactions, ion-exchange) as well as electrophoretic migration. The influence of ion-exchange and hydrophobic interactions on the retention/migration of the analytes could be manipulated by varying the concentration of a competing ion and/or the amount of organic modifier present in the background electrolyte. Additionally the effects of pH changes on both the chromatographic interactions as well as the electrophoretic migration of the analytes were investigated.  相似文献   

12.
The retention and selectivity of the chromatographic separation of basic (cationic) analytes on a polybutadiene-coated zirconia (PBD-ZrO2) stationary phase have been studied in greater detail than in previous studies. These separations are strongly influenced by the chemistry of the accessible surface of zirconia. In the presence of buffers which contain hard Lewis bases (e.g., phosphate, fluoride, carboxylic acids) zirconia's surface becomes negatively charged due to adsorption of the buffer anion at the hard Lewis acid sites. Consequently, under most conditions (e.g., neutral pH), cationic analytes undergo both hydrophobic and cation-exchange interactions. This mixed-mode retention process generally leads to greater retention factors for cations relative to those on silica-based reversed phases despite the lower surface areas of the zirconia phase, but, more importantly, adsorption of hard Lewis bases can be used to control the chromatographic selectivity for cationic analytes on these zirconia-based stationary phases. In contrast to our prior work, here we show that when mixed-mode retention takes place, both retention and selectivity are easily adjusted by changing the type of hard Lewis base buffer anion, the type of buffer counter-ion (e.g., sodium, potassium, ammonium), the pH, and the ionic strength of the eluent as well as the type and amount of organic modifier.  相似文献   

13.
In the present work, we study the effect of mobile phase anionic additive type and concentration on the selectivity, efficiency, and sample loading capacity of cationic drugs in reversed-phase liquid chromatography (RPLC). The type and concentration of an anionic additive are known to have a strong effect on the absolute retention of cations in RPLC; in contrast they have only a small effect on the selectivity of one cation relative to a second as seen here. This is mainly due to the similarity of the ion pair formation constants between the selected cations. The limiting retention factors of cations (i.e. the retention factor of the fully ion-paired analyte at very high additive concentration) are roughly proportional to their inherent hydrophobicities (i.e. the retention factor of the analyte in the absence of the anionic additive). With a given anion, differences in ion pairing strength between the solutes are required for effective selectivity adjustment. Based on the Wade–Lucy–Carr (W–L–C) kinetic model of overload peaks, the approach we developed in our previous work was used to study the effect of mobile phase anionic additives type and concentration on the limiting plate count (N0) and sample loading capacity (ω0.5) of various cationic drugs. Under linear chromatographic conditions, where the analyte exhibits its smallest peak width and thus maximum apparent plate count, the type and concentration of anionic additives have almost no effect on peak width. In comparison to neutral analytes the sorption isotherms of cationic species are very easily overloaded even when many fewer moles of cations as compared to neutrals are injected. We showed that different anionic additives profoundly affect the cations’ “overload profiles” (i.e. plots of plate count versus amount injected) by changing the sample loading capacities. The increase in sample loading capacities with different anions show the same order as the extent of ion pairing between the anions and the basic analytes. The detrimental effect of sample overloading on peak width can be greatly diminished by using either a stronger ion pairing agent or a higher concentration of a given ion pairing agent. Both effects operate by increasing the sample loading capacity, thereby allowing more solute to be injected. We believe that the increase in sample loading capacity described above is due in part to the increase in the number of ion-exchange sites as more anions sorb to the stationary phase. At the same time, the formation of a neutral ion-paired analyte also increases the amount of cation which can be loaded onto the stationary phase by allowing a greater fraction of the analyte to be present in the stationary phase as an electrically neutral (i.e. ion-paired) species.  相似文献   

14.
A mixed-mode chromatographic (MMC) sorbent was prepared by functionalizing the silica sorbent with a pentafluorophenyl (PFP) ligand. The resulting stationary phase provided a reversed-phase (RP) retention mode along with a relatively mild strong cation-exchange (SCX) retention interaction. While the mechanism of interaction is not entirely clear, it is believed that the silanols in the vicinity of the perfluorinated ligand act as strongly acidic sites. The 2.1 mm x 150 mm column packed with such sorbent was applied to the separation of peptides. Linear RP gradients in combination with salt steps were used for pseudo two-dimensional (2D) separation and fractionation of tryptic peptides. An alternative approach of using linear cation-exchange gradients combined with RP step gradients was also investigated. Besides the attractive forces, the ionic repulsion contributed to the retention mechanism. The analytes with strong negatively charged sites (phosphorylated peptides, sialylated glycopeptides) eluted in significantly different patterns than generic tryptic peptides. This retention mechanism was employed for the isolation of phosphopeptides or sialylated glycopeptides from non-functionalized peptide mixtures. The mixed-mode column was utilized in conjunction with a phosphopeptide enrichment solid phase extraction (SPE) device packed with metal oxide affinity chromatography (MOAC) sorbent. The combination of MOAC and mixed-mode chromatography (MMC) provided for an enhanced extraction selectivity of phosphopeptides and sialylated glycopeptides peptides from complex samples, such as yeast and human serum tryptic digests.  相似文献   

15.
A novel mixed-mode reversed-phase and cation-exchange high-performance liquid chromatography (HPLC) method is described to simultaneously determine four related impurities of cations, zwitterions and neutral compounds in developmental Drug A. The commercial column is Primesep 200 containing hydrophobic alkyl chains with embedded acidic groups in H(+) form on a silica support. The mobile phase variables of acid additives, contents of acetonitrile and concentrations of potassium chloride have been thoroughly investigated to optimize the separation. The retention factors as a function of the concentrations of potassium chloride and the percentages of acetonitrile in the mobile phases are investigated to get an insight into the retention and separation mechanisms of each related impurity and Drug A. Furthermore, the elution orders of the related impurities and Drug A in an ion-pair chromatography (IPC) are compared to those in the mixed-mode HPLC to further understand the chromatographic retention behaviors of each related impurity and Drug A. The study found that the positively charged Degradant 1, Degradant 2 and Drug A were retained by both ion-exchange and reversed-phase partitioning mechanisms. RI2, a small ionic compound, was primarily retained by ion-exchange. RI4, a neutral compound, was retained through reversed-phase partitioning without ion-exchange. Moreover, the method performance characteristics of selectivity, sensitivity and accuracy have been demonstrated to be suitable to determine the related impurities in the capsules of Drug A.  相似文献   

16.
A novel type of silica-based sulfonate-modified reversed phase ((-)SO3-HC-C8) has been synthesized; it is based on a newly developed acid stable "hyper-crosslinked" C8 derivatized reversed phase, denoted HC-C8. The (-)SO3-HC-C8 phases containing controlled amounts of sulfonyl groups were made by sulfonating the aromatic hyper-crosslinked network of the HC-C(8) phase at different temperatures. The (-)SO3-HC-C8 phases are only slightly less hydrophobic than the parent HC-C8 phase. The added sulfonyl groups provide a unique strong cation-exchange selectivity to the hydrophobic hyper-crosslinked substrate as indicated by the very large C coefficient as shown through Snyder's hydrophobic subtraction reversed-phase characterization method. This cation-exchange activity clearly distinguishes the sulfonated phase from all other reversed phases as confirmed by the very high values of Snyder's column comparison function F(s). In addition, as was found in previous studies of silica-based and zirconia-based reversed phases, a strong correlation between the cation-exchange interaction and hydrophobic interaction was observed for these sulfonated phases in studies of the retention of cationic solutes. The overall chromatographic selectivity of these (-)SO3-HC-C8 phases is greatly enhanced by its high hydrophobicity through a "hydrophobically assisted" ion-exchange retention process.  相似文献   

17.
该文以聚苯胺/石墨烯复合材料为涂覆材料,制备了一种涂覆型阴离子交换固定相。首先以苯胺和石墨烯为原料制备聚苯胺/石墨烯复合材料,并通过物理吸附涂覆在聚苯乙烯-二乙烯苯微球表面;然后以聚苯胺中的氮原子为反应位点,通过季铵化制备一系列具有不同交换容量的涂覆型阴离子交换固定相。通过扫描电镜(SEM)、傅里叶红外光谱(FT-IR)和元素分析(EA)对该涂覆型阴离子交换固定相进行表征,结果表明聚苯胺/石墨烯成功地涂覆在微球表面且发生了季铵化。通过分离常规阴离子和有机酸,对自制阴离子交换色谱柱的色谱性能进行评价。结果显示,8次季铵化的聚苯胺/石墨烯涂覆聚苯乙烯-二乙烯苯阴离子交换色谱柱对常规阴离子和有机酸呈现良好的分离效果。  相似文献   

18.
A silica-based monolithic stationary phase with mixed-mode of reversed phase (RP) and weak anion-exchange (WAX) for capillary electrochromatography (CEC) has been prepared. The mixed-mode monolithic silica column was prepared using the sol–gel technique and followed by a post-modification with hexadecyltrimethoxysilane (HDTMS) and aminopropyltrimethoxysilane (APTMS). The amino groups on the surface of the stationary phase were used to generate a substantial anodic EOF as well as to provide electrostatic interaction sites for charged compounds at low pH. A cathodic EOF was observed at pH above 7.3 due to the full ionization of residual silanol groups and the suppression in the ionization of amino groups. A variety of analytes were used to evaluate the electrochromatographic characterization and column performance. The monolithic stationary phase exhibited RP chromatographic behavior toward neutral solutes. The model anionic solutes were separated by the mixed-mode mechanism, which comprised RP interaction, WAX, and electrophoresis. Symmetrical peaks can be obtained for basic solutes because positively charged amino groups can effectively minimize the adsorption of positively charged analytes to the stationary phase.  相似文献   

19.
A new liquid chromatographic system was developed to measure protein-drug binding affinity indirectly without albumin and was evaluated using log nK values of drugs measured by a modified Hummel-Dreyer method using purified human serum albumin. The retention factors of acidic and basic drugs were measured by reversed-phase and ion-exchange liquid chromatography in sodium phosphate buffer, pH 7.40, containing 50 vol.% methanol at 37 °C. The bonded phases were pentyl, guanidino and carboxyl phases. The combined retention factors were correlated with the log nK values measured by a modified Hummel-Dreyer method because glycosylation of human serum albumin did not significantly affect log nK value. The correlation coefficients were 0.949 (n=7) for acidic drugs and 0.978 (n=5) for basic drugs. The log nK values of 26 acidic and 18 basic drugs were predicted from their retention factors measured by reversed-phase and ion-exchange liquid chromatography.  相似文献   

20.
In a previous work, we studied the retention behavior of monovalent and divalent carboxylic acids on a highly cross-linked polystryene-divinylbenzene anion-exchange column (IonPac AS4A-SC) using a carbonate-based buffer, and a retention model was applied to the chromatographic data obtained. In this work we characterized the retention of carboxylates (formic, acetic, propionic, lactic, pyruvic, oxalic, malonic, succinic, fumaric, maleic, tartaric, glutaric, adipic, malic, mucic, trans-beta-hydromuconic, trans,trans-muconic acids) on a column with higher hydrophilicity (IonPac AS11) according to analyte and stationary phase properties, using previously investigated eluent compositions and comparing the retention data obtained. Moreover, the effect of organic modifiers (CH3OH and CH3CN) in the eluent on the retention factors was also evaluated. The chromatographic data obtained on the IonPac AS11 column were fitted by the retention model and allowed one to obtain and to compare ion-specific selectivity constants (parameters of the model) with the ones obtained with the previous column.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号