共查询到20条相似文献,搜索用时 15 毫秒
1.
Various flow sample handling approaches coupled to capillary electrophoresis (CE) are reviewed, covering the research in this field in the 12 years since the milestone year of 1997, when practical interfaces to on-line couple flow injection (FI) and capillary electrophoresis were first developed independently by two research groups. Some previous attempts are also presented. Since 1997 a plethora of ingenious coupled systems have been developed. Although several reviews are available on various aspects of the topic, we have opted for a comprehensive overview of all FI-CE systems, as well as related and similar systems. This coupling has thus also led to the development of systems based on hybrids between the classical and microchip approaches. Truly microchip FI-CE systems are also included in this review.The developed systems have been used for various sample treatments, including on-line membrane-assisted sample treatment, column-based preconcentration, on-line derivatization and monitoring, to name just a few. The utility of coupling flow sampling to CE has been demonstrated in various practical applications that are discussed in detail. The current state-of-the-art and foreseeable future developments are also discussed. 相似文献
2.
A background electrolyte (BGE) containing a 100 mM concentration of an alkylammonium cation with ethyl, propyl or butyl groups provides an excellent medium for separation of anions by capillary electrophoresis (CE). Two major effects were noted. Use of one of a series of alkylammonium cations in the BGE at a selected pH provides a simple and effective way to vary and control electroosmotic flow (EOF) over a broad range. It is believed that the alkylammonium cations are coated onto the capillary surface through a reversible dynamic equilibrium. Secondly, alkylammonium cations modify the electrophoretic migration of sample anions and the electroosmotic migration of neutral organic analytes by association interaction. This selective interaction results in improved anion separations and permits the simultaneous separation of neutral analytes. The degree of association interaction varies with the bulk and hydrophobicity of the alkylammonium cations. Incorporation of an aliphatic amine salt of moderate molecular weight in the running electrolyte provides a valuable new way to vary the migration times of sample anions and to optimize their resolution. The interactions between alkylammonium cations and sample anions or neutral organics appear to take place entirely within the liquid phase and do not require a polymeric or micellar pseudo phase. 相似文献
3.
Burkhard Horstkotte Olaf Elsholz 《International journal of environmental analytical chemistry》2013,93(12):797-811
A combination of a laboratory-made capillary electrophoresis system and a sequential injection analysis equipment is described. For characterization, the system was successfully applied to the separation and quantification of nitrophenols. A blue LED was used as light source, and hydrodynamic injection was carried out by using a pressure-stable solenoid valve and an inflatable pressure reservoir. A good reproducibility of migration time (0.5%) and peak heights (5%) were obtained. The calibration by using peak heights was found to be linear up to 776?µmol?L?1 for all three compounds. The system was robust and reliable for autonomous analysis without observation. All maintenance requirements including the conditioning of the capillary and flushing of both buffer reservoirs were carried out automatically. Instrumentation aspects of the capillary electrophoresis part are compared with former described hyphenated flow systems showing maximal operation versatility. Instrumental control and data evaluation were carried out using the software package AutoAnalysis. 相似文献
4.
The system comprises two flow injection-capillary electrophoresis interfaces into which the opposite ends of the separation capillary are inserted. The electrolyte solution flows through both interfaces by use of hydrostatic pressure. The injection of the samples into the electrolyte flow is accomplished by a rotary-type chromatographic valve at the grounded side and by a pinch-valve injector at the high-voltage side that provides sufficient isolation from the high electric field. The system allows a fully automated dual-injection sequence of samples from both capillary ends and simultaneous electrophoretic separation of anions and cations in the samples. The analytes are detected by a high-voltage contactless conductometric detector positioned approximately in the middle of the separation capillary. The parameters of the system were evaluated. The repeatability of the flow injection-capillary electrophoresis system for the simultaneous determination of anions and cations was evaluated for ten consecutive injections and relative standard deviation (RSD) values for peak areas were better than 1.0%. The sample throughput for total ionic analysis was estimated to be 25 samples per hour. The system was used for automated simultaneous analysis of anions and cations in various real samples. Using a short separation capillary, rapid total ionic analysis in less then 1 min is demonstrated. 相似文献
5.
Qun Fang Fu-Ren Wang Shi-Li Wang Shu-Sheng Liu Shu-Kun Xu Zhao-Lun Fang 《Analytica chimica acta》1999,390(1-3):27-37
A sequential injection micro-sample introduction system was coupled to a microfluidic-chip based capillary electrophoresis system through a split–flow sampling interface integrated on the micro-chip. The microfluidic system measured 20×70×3 mm in dimension, and was produced using a non-lithographic approach with components readily available in the analytical laboratory. In the H-configuration channel design the horizontal separation channel was a 75 μm I.D.×60 mm quartz capillary, with two vertical side arms produced from plastic tubing. The conduits were embedded in silicon elastomer with a planar glass base. Sequential introduction of a series of samples with about 2.5% carryover was achieved at 48 h−1 throughput with samples containing a mixture of fluorescein isothiocyanate (FITC)-labeled amino acids using SI sample volumes of 3.3 μl and carrier flow-rate of 2.0 ml min−1. Baseline separation was achieved for FITC-labeled arginine, phenylalanine, glycine and FITC (laser induced fluorescence detection) in sodium tetraborate buffer (pH 9.2) within 8–80 s, at separation lengths of 25–35 mm and electrical field strengths of 250–1500 V cm−1, with plate heights in the 0.7–3 μm range. 相似文献
6.
Sequential capillary electrophoresis analysis using optically gated sample injection and UV/vis detection
下载免费PDF全文

Xiaoxia Liu Miaomiao Tian Mohamed Amara Camara Liping Guo Li Yang 《Electrophoresis》2015,36(19):2380-2385
We present sequential CE analysis of amino acids and l ‐asparaginase‐catalyzed enzyme reaction, by combing the on‐line derivatization, optically gated (OG) injection and commercial‐available UV‐Vis detection. Various experimental conditions for sequential OG‐UV/vis CE analysis were investigated and optimized by analyzing a standard mixture of amino acids. High reproducibility of the sequential CE analysis was demonstrated with RSD values (n = 20) of 2.23, 2.57, and 0.70% for peak heights, peak areas, and migration times, respectively, and the LOD of 5.0 μM (for asparagine) and 2.0 μM (for aspartic acid) were obtained. With the application of the OG‐UV/vis CE analysis, sequential online CE enzyme assay of l ‐asparaginase‐catalyzed enzyme reaction was carried out by automatically and continuously monitoring the substrate consumption and the product formation every 12 s from the beginning to the end of the reaction. The Michaelis constants for the reaction were obtained and were found to be in good agreement with the results of traditional off‐line enzyme assays. The study demonstrated the feasibility and reliability of integrating the OG injection with UV/vis detection for sequential online CE analysis, which could be of potential value for online monitoring various chemical reaction and bioprocesses. 相似文献
7.
A purpose-made set-up featuring an automated fast injector allowed the easy optimization of the injected amount and the adjustment of the separation length of conventional capillaries from a minimum of 5 cm upward. It was found that a compromise in capillary length for separation efficiency and analysis time also has to take into account the injected amount, which in turn affects the sensitivity and hence the detection limit. The versatility of the system was demonstrated by the analysis of the major cations and anions in natural water samples in less than 1 min, the concurrent determination of a mixture of amino acids and carbohydrates in 160 s, and of three active ingredients in a pharmaceutical preparation in 40 s. Plate numbers were typically around 50,000 and detection limits down to 1 M could be achieved. 相似文献
8.
James P. Landers Robert P. Oda Benjamin Madden Tamara P. Sismelich Thomas C. Spelsberg 《Journal of separation science》1992,15(8):517-525
Run-to-run sample separation reproducibility has been compared on two commercial high performance capillary electrophoresis units which differ in the mode by which the capillary temperature is thermostatted. Three standard analytes, differing dramatically in molecular character and size, were used for the analysis: benzoic acid, a 14 amino acid peptide from human chorionic gonadotropin, and ribonuclease A represent, respectively, small stable organic molecules, small peptides with little or no secondary structure, and proteins with secondary structure. These standards were evaluated with regard to reproducibility of migration time, peak area, and peak height. The analyses, performed in buffers of optimum pH for the separations, demonstrated that the liquid and forced air convection thermostatted systems both performed extremely well. The reproducibility, as judged by the percent coefficient of variance (% CV) of replicate analyses, was generally found to be less than 1 % (migration time); the reproducibility decreased in the order migration time > peak height > peak area. Whereas the absolute % CV values for MTrel (migration relative to a standard) observed with the liquid thermostatted system were 2- to 4-fold lower than those observed with the forced air convection thermostatted system, there was little statistically significant difference between the two. As expected, the data indicated a reduction in reproducibility as the complexity of the analyte increased, perhaps as the result of an increased potential for wall interactions. Comparing separations in which low (≈?1 watt/meter [W/m] of capillary) and high (>5 W/m) Joule heat was generated by altering the sodium chloride content of the buffer revealed few statistically significant differences in the reproducibility obtained from the two systems. With these particular standard analytes and their respective buffer systems, there appears to be little difference between forced air convection and liquid thermostatting of the capillary. 相似文献
9.
Micelle to solvent stacking (MSS) is a new on-line sample concentration technique for charged analytes in capillary zone electrophoresis (CZE). Sample concentration in MSS mainly relies on the reversal in the effective electrophoretic mobility of the analyte at the boundary zone between the sample solution (S) and CZE background solution (BGS) inside the capillary. The basic condition for MSS is that the S is prepared in a matrix that contains an additive (i.e., micelles) which interacts with and has an opposite charge compared to the analytes. In addition, the BGS must contain a sufficient percentage of organic solvent. MSS was first reported for organic cations using anionic dodecyl sulfate micelles as additive in the S and methanol or acetonitrile as organic solvent in the BGS. Here, theoretical and experimental studies on MSS are described for organic anions using cationic cetyltrimethyl ammonium micelles as additive in the S and methanol as organic solvent in the BGS. Up to an order of magnitude improvement in concentration sensitivity was obtained for the test hypolipidaemic drugs using MSS in CZE with UV detection. The optimized method was also evaluated to the analysis of a spiked wastewater sample that was subjected to a simple extraction step. 相似文献
10.
Thanh Duc Mai Benjamin Bomastyk Hong Anh Duong Hung Viet Pham Peter C. Hauser 《Analytica chimica acta》2012
An extension of a capillary electrophoresis instrument coupled to a sequential injection analysis manifold was developed for automated measurements with on-line solid-phase extraction preconcentration. An in-house built capacitively coupled contactless conductivity detector was employed for sensitive detection with narrow capillaries of 25 μm internal diameter. The system was assembled into standardized 19 in. frames and racks for easy transport and mobile deployment. The system can be left running unattendedly without manual intervention with good operation stability. To demonstrate the application of the system, a method for the determination of four drugs, namely ibuprofen, diclofenac, naproxen and bezafibrate, was developed with enrichment factors of up to several hundreds. Detection of the drug residues down to the nM-scale was found possible and the method was found suitable for the detection of ibuprofen in the waste water of a hospital in Hanoi. 相似文献
11.
A capillary electrophoresis (CE) instrument with capacitively coupled contactless conductivity detection (C4D) based on a sequential injection analysis (SIA) manifold was refined. Hydrodynamic injection was implemented to avoid a sampling bias by using a split-injection device based on a needle valve for precise adjustment. For safety and reliability, the integrity of the high voltage compartment at the detection end was fully maintained by implementing flushing of the high voltage interface through the capillary. With this set-up, extended fully automated monitoring applications are possible. The system was successfully tested in the field for the determination of the concentration levels of major inorganic cations and anions in a creek over a period of 5 days. 相似文献
12.
Enantiomer separation by capillary electrophoresis using DEAE-dextran and aminoglycosidic antibiotics 总被引:2,自引:0,他引:2
Summary Diethylaminoethyl (DEAE) dextran hydrochloride and three kinds of aminoglycosidic antibiotics; fradiomycin sulfate, kanamycin sulfate and streptomycin sulfate, were employed as chiral selectors in capillary electrophoresis, enantiomer separation. These selectors are cationic or basic because of amino functionality and therefore used for enantiomer separation of acidic compounds. To avoid adsorption of the basic or cationic selectors on the capillary inner surface, a coated capillary was employed. Among those tested, enantiomers of binaphthyl compounds and synthetic intermediates of diltiazem analogues were separated. Methanol addition was effective for the improvement of peak shape and resolution. 相似文献
13.
Changgang Huang Youri E.C. Taes Willy R.G. Baeyens Joris R. Delanghe Xiumin Shen Na Na Jin Ouyang 《Journal of chromatography. A》2010,1217(3):405-410
To improve the detection sensitivity and determine phenotypes of haptoglobin (Hp), a prefilling technique was developed and tested in capillary electrophoresis (CE) with UV–vis absorbance detection. Adding 0.01% sodium dodecyl sulfate (SDS) to the protein sample and 0.1% SDS to the prefilling buffer solution, on-line stacking and microheterogeneity separation of Hp were achieved. In addition, the influences of pH, buffer concentration, sample and prefilling buffer SDS concentration upon resolution were examined. Under optimized conditions, Hp-microheterogeneity was well resolved and two phenotypes of Hp (Hp 1-1 and Hp 2-2) were differentiated. This method was applied to the analysis of sera from normal individuals and β-Thalassemia patients. After the depletion of albumin (HSA) and immunoglobulin G (IgG), this method allowed to determine two phenotypes in different individuals and to detect the decrease of Hp in β-Thalassemia patients. Featuring high efficiency, speed and simplicity, the proposed method shows great potential for use in clinical diagnosis and proteome research. 相似文献
14.
A dialyser unit, equipped with a passive neutral membrane, was incorporated into the conduits of a sequential injection (SI) system for the on-line removal of suspended solids and simultaneous dilution of the analyte before reaction and detection of the analyte. The system was applied to the determination of zinc(II) in fertilisers. The fully automated system is able to analyse zinc at a sampling frequency of ten samples per hour at a %R.S.D. of better than 0.55. The calibration graph was linear between 10 and 50 mg l−1. The detection limit was found to be 4.75 mg l−1. The results obtained with the proposed SI analyser compared favourably with the standard manual flame atomic absorption spectrometric method. 相似文献
15.
Lourdes Arce Petr Kuban Angel Rí os Miguel Valc rcel Bo Karlberg 《Analytica chimica acta》1999,390(1-3):39-44
On-line ion-exchange preconcentration, performed in a flow injection analysis system, has been integrated with capillary electrophoresis via a specially designed interface, and a sensitive and selective method for the determination of nitrite, nitrate, bromide and iodide using direct UV absorbance detection has been developed. Fivefold enrichment of these aforementioned anions can be realised. Separation conditions such as carrier electrolyte and concentration of electroosmotic modifier were investigated. Limits of detection were ca. 10 ng ml−1 for nitrite and nitrate in aqueous samples, and the overall relative standard deviation was about 5%. 相似文献
16.
Pressure assisted capillary electrophoresis in capillaries with internal diameters of 10 μm was found possible without significant penalty in terms of separation efficiency and sensitivity when using contactless conductivity detection. A sequential injection analysis manifold consisting of a syringe pump and valves was used to impose a hydrodynamic flow in the separation of some inorganic as well as organic cations. It is demonstrated that the approach may be used to optimize analysis time by superimposing a hydrodynamic flow parallel to the electrokinetic motion. It is also possible to improve the separation by using the forced flow to maintain the analytes in the capillary, and thus the separation field, for longer times. The use of the syringe pump allows flexible and precise control of the pressure, so that it is possible to impose pressure steps during the separation. The use of this was demonstrated for the speeding up of late peaks, or forcing repeated passage of the sample plug through the capillary in order to increase separation. 相似文献
17.
Studying the size/shape separation and optical properties of silver nanoparticles by capillary electrophoresis 总被引:3,自引:0,他引:3
This paper describes the feasibility of employing capillary electrophoresis (CE) to separate silver particles in nanometer regimes. We have found that the addition of an anionic surfactant, sodium dodecyl sulphate (SDS), to the running electrolyte prevents coalescence of the silver particles during the process, which improves the separation performance; the concentration of SDS required for optimal silver nanoparticle separation is ca. 20 mM. By monitoring the electropherograms using a diode-array detection (DAD) system, we have also investigated the separation of suspended silver nanorods with respect to their shapes. Our results demonstrate that the combination of CE and DAD is a powerful one for the separation and characterization of various silver nanoparticles. 相似文献
18.
Mikhail Kamencev Nina Yakimova Leonid Moskvin Irina Kuchumova Kirill Tkach Yulia Malinina Oleg Tungusov 《Electrophoresis》2015,36(24):3014-3017
Separation of 6Li and 7Li isotopes by CZE was demonstrated. The BGE contained 5 mM 4‐aminopyridine, 0.9 mM oxalic acid, 0.25 mM CTAB, and 0.25% w/v Tween 20 (рН = 9.2). The running conditions were +25 kV at 30°C with indirect photometric detection at 261 nm. Under optimal experimental conditions, the analysis time was less than 21 min. Separation of Li preparations with mole fraction of 6Li ranging from 3.44 up to 90.38% was demonstrated. 相似文献
19.
20.
We developed a capillary electrophoresis with chemiluminescence detection system using 2-methyl-6-p-methoxyphenylethynylimidazopyrazinone as a chemiluminescence reagent for determination of antioxidants of superoxide anions. 2-Methyl-6-p-methoxyphenylethynylimidazopyrazinone reacted with superoxide anions generated through the reaction of hypoxanthine and xanthine oxidase, and then emitted chemiluminescence. Suppression of the chemiluminescence in the presence of antioxidants for superoxide anions was introduced as a detection principle for antioxidants into the capillary electrophoresis with chemiluminescence detection system. After optimizing the analytical conditions, various antioxidants, such as superoxide dismutase, nitroblue tetrazolium, ascorbic acid, and catechin, were subjected to the present system. They gave negative peaks due to the quenching effect; the detection limits of superoxide dismutase, nitroblue tetrazolium, ascorbic acid, and catechin were 1, 100, 100, and 10 μM, respectively (S/N = 2). A model sample consisting of superoxide dismutase and nitroblue tetrazolium was satisfactorily separated and detected within ca. 10 min. We also applied the present system to analysis of catechin in green tea as a real sample. 相似文献