首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The electrooxidation of the antitumour drug 2-methyl-9-hydroxyellipticinium (Celiptium) was investigated by cyclic, differential-pulse and adsorptive voltammetry at carbon paste (CPE) and lipid-modified carbon paste electrodes (LM-CPE). The influence of the paste composition, i.e., the ratio of graphite to binder, was studied in order to elucidate the nature of the accumulation process at the surface of the CPE. The electrode surface coverage at saturation was calculated. A.c. measurements at the CPE and at the LM-CPE during the accumulation of Celiptium demonstrated an increased differential double layer capacity of the LM-CPE. The influence of several parameters that affect the adsorptive step at the CPE was investigated, such as pH, ionic strength and interfering ions. Improved signals were obtained at the CPE and the detection limit in 0.1 M sodium perchlorate (tacc.=3 min) was found to be 2 × 10?10 M. Measurements of the drug in dilute standard serum samples were done using the medium-exchange technique.  相似文献   

2.
Li Liu  Jun-feng Song  Peng-fei Yu  Bin Cui 《Talanta》2007,71(5):1842-1848
A novel voltammetric method for the determination of β-d-glucose (GO) is proposed based on the reduction of Cu(II) ion in Cu(II)(NH3)42+–GO complex at lanthanum(III) hydroxide nanowires (LNWs) modified carbon paste electrode (LNWs/CPE). In 0.1 mol L−1 NH3·H2O–NH4Cl (pH 9.8) buffer containing 5.0 × 10−5 mol L−1 Cu(II) ion, the sensitive reduction peak of Cu(II)(NH3)42+–GO complex was observed at −0.17 V (versus, SCE), which was mainly ascribed to both the increase of efficient electrode surface and the selective coordination of La(III) in LNW to GO. The increment of peak current obtained by deducting the reduction peak current of the Cu(II) ion from that of the Cu(II)(NH3)42+–GO complex was rectilinear with GO concentration in the range of 8.0 × 10−7 to 2.0 × 10−5 mol L−1, with a detection limit of 3.5 × 10−7 mol L−1. A 500-fold of sucrose and amylam, 100-fold of ascorbic acid, 120-fold of uric acid as well as gluconic acid did not interfere with 1.0 × 10−5 mol L−1 GO determination.  相似文献   

3.
Preeti Nigam  Subir Kundu 《Talanta》2009,77(4):1426-1431
Cefotaxime a third generation cephalosporin drug estimation in nanomolar concentration range is demonstrated for the first time in aqueous and human blood samples using novel Schiff base octahedral Zn(II) complex. The cefotaxime electrochemistry is studied over graphite paste and Zn(II) complex modified graphite paste capillary electrodes in H2SO4 (pH 2.3) using cyclic voltammetry and differential pulse voltammetry. Cefotaxime enrichment is observed over Zn(II) complex modified graphite paste electrode probably due to interaction of functional groups of cefotaxime with Zn(II) complex. Possible interactions between metal complex and cefotaxime drug is examined by UV-vis and electrochemical quartz crystal microbalance (EQCM) techniques and further supported by voltammetric analysis. Differential pulse voltammetry (DPV) with modified electrode is applied for the determination of cefotaxime in acidified aqueous and blood samples. Cefotaxime estimation is successfully demonstrated in the range of 1-500 nM for aqueous samples and 0.1-100 μM in human blood samples. Reproducibility, accuracy and repeatability of the method are checked by triplicate reading for large number of samples. The variation in the measurements is obtained less than 10% without any interference of electrolyte or blood constituents.  相似文献   

4.
Zen JM  Hsu CT 《Talanta》1998,46(6):1363-1369
A square-wave voltammetric method together with Nafion®-coated carbon paste electrodes were used for the selective determination of uric acid in the presence of a high concentration of ascorbic acid. Since the oxidation potential of uric acid is about 200 mV more positive than that of ascorbic acid at the Nafion®-coated carbon paste electrode, the selectivity can be greatly improved simply by applying an electrolysis potential of +0.4 V vs. Ag/AgCl where only ascorbic acid is oxidised. The acceptable tolerance of ascorbic acid concentration for the determination of uric acid is as high as 1.5 mM. With 30 s of electrolysis time, a linear calibration curve is obtained over the 0–50 μM range in 0.05 M citrate buffer solution, pH 4.0, with slope (μA/μM) and correlation coefficient of 0.34 and 0.9984, respectively. The detection limit (3σ) is 0.25 μM. The practical analytical utility is illustrated by selective measurements of uric acid in human urine without any preliminary treatment.  相似文献   

5.
A new modified carbon paste electrode based on a recently synthesized mercury (II) complex of a pyridine containing proton transfer compound as a suitable carrier for Br ion is described. The electrode has a linear dynamic range between 3.00×10−2 and 1.0×10−5 M with a near-Nernastian slope of 61.0±0.9 mV per decade and a detection limit of 4.0×10−6 M (0.32 ppm). The potentiometric response is independent of the pH of the solution in the pH range 4.0–8.3. The electrode possesses the advantages of low resistance, fast response and good over a variety of other anions. It was applied as an indicator electrode in potentiometric titration of bromide ions and for the recovery of Br from tap water.  相似文献   

6.
A new modified carbon paste electrode (CPE) based on a recently synthesized Schiff base complex of Fe(III) as a suitable carrier for I ion is described. The electrode exhibits a super Nernstian slope of 71.0±0.3 mV per decade for I ion over a wide concentration range from 1.0×10−6 to 5.0×10−1 M, with a low detection limit of 6.5×10−7 M. It has a relatively fast response time, a satisfactory reproducibility and relatively long life time. The proposed sensor shows a fairly good selectivity toward I ion in comparison to other common anions. The potentiometric response is independent of the pH of the test solution in the pH range 3.5–10.0. Spectrophotometric studies confirmed the redox-type response mechanism of the electrode toward iodide ion. The proposed electrode was used as an indicator electrode in potentiometric titration of iodide ion.  相似文献   

7.
Lawrence NS  Deo RP  Wang J 《Talanta》2004,63(2):443-449
The use of a carbon-nanotube paste (CNTP) electrode provides an effective means for the determination of homocysteine. A decrease of ca. 120 mV in the overpotential for the oxidation of homocysteine compared to a traditional carbon paste electrode, is reported along with greatly enhanced signal-to-noise characteristics. The analytical parameters have been assessed with a linear range from 5 to 200 μM and a detection limit of 4.6 μM. Furthermore, the generic nature of this increased reactivity of the CNTP surface towards thiol moieties has been demonstrated with cysteine, glutathione and n-acetylcysteine, providing a greatly enhanced electrochemical response compared to the carbon paste electrode.  相似文献   

8.
A chemically modified carbon paste electrode with 3,4-tetra pyridinoporphirazinatocobalt(II) (Co(3,4 tppa) was applied to the determination of free cyanide ion. The electrode has a linear range between 1.5 × 10−5 M and 1.0 × 10−2 M with a Nernstian slope of 60 ± 1.5 mV/decade and its detection limit is 9 × 10−6 M. The response time of electrode is 5 min. The proposed electrode was applied successfully for the determination of cyanide in commercially available spring water. Some anions, such as SCN, I, Cl, Br and oxalate that are usually serious interfering species for most of cyanide selective electrodes, did not have any interfering effect for this proposed electrode.  相似文献   

9.
The preparation and aqueous electrochemistry of carbon paste electrodes modified by some amino-substituted 9,10-anthraquinones are reported. In all cases, the reduction processes studied by cyclic voltammetry reveal a quasi-reversible behavior. The half-wave potentials were calculated as a function of the solution pH and from the resulting potential-pH plots the formal potentials and pK a values of different redox and acid-base couples involved at various pH ranges were evaluated. The diffusion coefficients of different anthraquinone derivatives used in paraffin oil were calculated by chronoamperometry. Received: 3 May 1999 / Accepted: 15 November 1999  相似文献   

10.
Zhang Y  Zheng J 《Talanta》2008,77(1):325-330
An ionic liquid modified carbon paste electrode (IL/CPE) had been fabricated by using hydrophilic ionic liquid 1-amyl-3-methylimidazolium bromide ([AMIM]Br) as a modifier. The IL/CPE was characterized by scanning electron microscope and voltammetry. Electrochemical behavior of rutin at the IL/CPE had been investigated in pH 3.29 Britton-Robinson (B-R) buffer solution by cyclic voltammetry (CV) and square wave voltammetry (SWV). The experimental results suggested that the modified electrode exhibited an electrocatalytic activity toward the redox of rutin. The electron transfer coefficient (α) and the standard rate constant (ks) of rutin at the modified electrode were calculated. Under the selected conditions, the reduction peak current was linearly dependent on the concentration of rutin in the range of 4.0 × 10−8 to 1.0 × 10−5 mol L−1 (r = 0.9998), with a detection limit of 1.0 × 10−8 mol L−1 (S/N = 3). The relative standard deviation (R.S.D.) for six times successful determination of 8.0 × 10−7 mol L−1 rutin was 1.2%. The proposed method was applied to determine rutin in tablet and urine sample. In addition, the IL/CPE exhibited a distinct advantage of simple preparation, surface renewal, good reproducibility and good stability.  相似文献   

11.
The electrocatalytic oxidation of cephalexin and cefazolin has been studied at a carbon paste electrode modified with cobalt salophen (CoSal) by cyclic voltammetry. The selectivity of the carbon paste modified with CoSal in detecting cephalexin and cefazolin was examined. To suggest the electrocatalytic mechanism for electro-oxidation of cefazolin, the electrochemical behavior of ceftriaxone was investigated which has a thiol group out of the beta lactam ring. The electrocatalytic oxidation of these antibiotics is shown to be irreversible at the CoSal modified electrode. Scan rate dependence of cefazolin, which is a sulfur-containing compound, has been examined. The results indicated that the electrocatalytic oxidation of the compounds is diffusion controlled. The responses of the modified electrode were compared with those of unmodified electrode and it has shown that the modified electrode has better sensitivity than unmodified electrode to the detection of cefazolin. The overall number of electrons contributed to the oxidation of cefazolin is obtained 1 by chronoamperometry; the number of electron involved in the rate-determining step was 1. The results of differential pulse voltammetry (DPV) using the modified electrode with high sensitivity were applied for the determination of cefazolin in human synthetic serum samples. The linear range was obtained from 1 × 10−5 to 1 × 10−3 M for DPV determination of cefazolin in buffered solutions (pH 3.0).  相似文献   

12.
A new chemically modified electrode (CME), -benzoinoxime (CUPRON) modified carbon paste electrode, for determining copper(II) is reported because of its excellent selectivity and sensitivity. The electrode is made by mixing a quantity of CUPRON (25%, w/w) with graphite powder (50%, w/w) and paraffin oil (25%, w/w). The CME preferentially deposits copper from the pH 8.5 NH3-NH4Cl buffer solution containing copper(II) under an open circuit and most of metal ions do not interfere with the measurements. The detection limit (S/N of three) for determining Cu(II) is 3 × 10–10 g/ml after 10 min accumulation in fast linear scan stripping voltammetric measurement. Linear calibration curves are obtained for Cu(II) concentration ranged from 1 × 10–8 M to 1 × 10–6 M. The response can be maintained with relative standard deviation of 6.0% in a 5 × 10–6 M Cu(II) solution after eight accumulation/measurement/ regeneration cycles at the same electrode surface. The effect resulted from carbon paste preparation, reduction potential, electrode renewal, electrolyte and solution pH, preconcentration time, concentration dependence, possible interference and other variables has been evaluated. As for application, the CME demonstrates its high sensitivity and copper-selectivity in complex composition samples, such as anodic mud and polluted water.  相似文献   

13.
El-Desoky HS  Ghoneim MM 《Talanta》2011,84(1):223-234
Silymarin is one of the most powerful natural substances that have the ability to protect and rebuild the liver cells damaged by alcohol and other toxic substances. Silymarin showed two irreversible anodic peaks in buffered solutions (pH 2.5-8.0) at either the bare carbon paste electrode or the montmorillonite-Ca modified carbon paste one. These two peaks have been attributed to oxidation of the two phenolic OH groups at positions C-20 and C-7 of silymarin molecule. A square-wave adsorptive anodic stripping voltammetry method was optimized for determination of silymarin utilizing the bare and the modified carbon paste electrodes. The method was fully validated and successfully applied for the determination of silymarin in commercial formulations and human serum without prior extraction utilizing both carbon paste electrodes. Limits of quantitation of 1 × 10−7 and 7 × 10−9 mol L−1 silymarin have been achieved in bulk form or in formulations while 2 × 10−7 and 8 × 10−9 mol L−1 silymarin were achieved in spiked human serum utilizing the bare carbon paste electrode and the modified one, respectively. The two electrodes exhibited excellent selectivity towards silymarin even in the presence of 102to 103-fold excess of its co-formulated drugs, common excipients, and common metal ions. The pharmacokinetic parameters of silymarin in plasma of healthy human volunteers were estimated following the administration of a single oral dose of 120 mg silymarin utilizing the modified carbon paste electrode. The estimated pharmacokinetic parameters were favorably compared with those reported in literature.  相似文献   

14.
A chemically modified carbon paste electrode was prepared by incorporating appropriate amounts of sodium humate(NaA). Palladium(II) was selectively accumulated in a solution of Britton-Robinson(B-R) buffer (pH 2.8) onto the electrode surface in open circuit mode. The subsequent electrochemical measurement was carried out by cyclic voltammetry (CV) and linear sweep anodic stripping voltammetry (LSASV) in a supporting electrolyte of 1.0 M HCl. The obtained oxidation currents (Ipa1 and Lpa2) were proportional to the Pd(II) concentration in the range of 4.7 × 10–6 - 9.4 × 10–8 M. The developed method was applied to the quantitative determination of palladium in real samples.  相似文献   

15.
A chemically modified carbon paste electrode was prepared by incorporating appropriate amounts of sodium humate(NaA). Palladium(II) was selectively accumulated in a solution of Britton-Robinson(B-R) buffer (pH 2.8) onto the electrode surface in open circuit mode. The subsequent electrochemical measurement was carried out by cyclic voltammetry (CV) and linear sweep anodic stripping voltammetry (LSASV) in a supporting electrolyte of 1.0 M HCl. The obtained oxidation currents (Ipa1 and Lpa2) were proportional to the Pd(II) concentration in the range of 4.7 × 10–6 - 9.4 × 10–8 M. The developed method was applied to the quantitative determination of palladium in real samples. Received: 6 March 1998 / Revised: 3 June 1998 / Accepted: 3 July 1998  相似文献   

16.
We report about the use of carbon paste electrode modified with kaolinite for analytical detection of trace lead(II) in domestic water by differential pulse voltammetry. Kaolinite clay was modified with tripolyphosphate (TPP) by impregnation method. The results show that TPP in kaolinite clay plays an important role in the accumulation process of Pb(II) on the modified electrode surface. The electroanalytical procedure for determination of Pb(II) comprised two steps: chemical accumulation of the analyte under open-circuit conditions, followed by electrochemical detection of the pre-concentrated species using differential pulse voltammetry. The analytical performance of this system has been explored by studying the effects of preconcentration time, carbon paste composition, pH, supporting electrolyte concentration, as well as interferences due to other ions. The calculated detection limit based on the variability of a blank solution (3sb criterion) for 10 measurements was 8.4 × 10−8 mol L−1, and the sensitivity determined from the slope of the calibration graph was 0.910 mol L−1. The reproducibility (RSD) for five replicate measurements at 1.0 mg L−1 lead level was 1.6%. The results indicate that this electrode is sensitive and effective for the determination of Pb2+.  相似文献   

17.
碳糊电极在有机物电化学分析中的应用   总被引:8,自引:1,他引:8  
碳糊电极作为一种制备简单、易于更新和重现性好的新型电极,在有机物分析中应用非常广泛。本文就从电极材料的选择、修饰剂的选用和有机物分类等几个方面对近几年碳糊电极在有机物电化学分析上的进展进行评述。引用文献54篇。  相似文献   

18.
研究了抗坏血酸(AA)和尿酸(UA)在裸碳糊电极(CPE)和溴化十六烷基吡啶(CPB)现场修饰碳糊电极(CPB/CPE)上的电化学行为.研究结果表明,在PBS水溶液中,AA和UA在CPB/CPE上氧化峰电流增加,峰电位负移,CPB/CPE对AA,UA电化学氧化反应产生了催化作用.微分脉冲法研究表明,在AA和UA共存体系中,AA和UA的氧化峰电位相差约220 mV,以此建立了AA和UA的电化学选择性测定方法.AA和UA的微分脉冲伏安氧化峰电流和其相应浓度分别在7.0×10-6~6.0×10-3 mol/L和5.0×10-7~6.0×10-4 mol/L的范围内呈良好的线性关系.在200倍AA共存时UA的检出限为5.0×10-6 mol/L,CPB修饰的碳糊电极直接应用于实际尿样中UA的测定.  相似文献   

19.
A Nickel Schiff base complex, insoluble in water, was synthesized and used as modifier. A Nickel Schiff base modified carbon paste electrode MCPE was build. The electrodes were characterized by scanning electron microscopy (SEM), energy dispersive X-Ray spectroscopy (EDXS), cyclic voltammetry and chronoamperometry. The modifier is elctroactive, a well defined redox couple of NiIII/NiII in alkaline medium was made in evidence. It presents a quasi-reversible system with electron transfer coefficient (0.38) and electron transfer rate of 4.5 s−1. The electrogenerated NiIII species on the surface of the electrode act as an excellent catalyst toward thiosulfate oxidation reaction with a chemical rate constant Kh equal to 23,6 M−1s−1. The different techniques involved in this study qualify our modified electrode as sensitive, reliable and very stable for thiosulfate analysis.  相似文献   

20.
The electrochemical removal of tramadol hydrochloride from aqueous solutions has been investigated under several operating conditions using a Pb/PbO2 electrode. The optimum conditions of the treatment process are: current density of 1000 mA/cm−2, pH ≈6, temperature of 10 °C and initial tramadol hydrochloride concentration of 100 mg/L. The time of electrolysis is 25 min for degradation rate of tramadol hydrochloride and chemical oxygen demeaned (COD) removal is 22 h. The results were obtained by UV–Vis spectrophotometer and the presently designed electrode was coincident.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号