首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
In this paper, we report the first-ever isotropic Compton profile of hafnium measured at an intermediate resolution, with 661.65 keV γ-radiation. To compare our experimental data, the theoretical computations have also been carried out within the framework of pseudopotential using CRYSTAL03 code and the renormalized-free-atom (RFA) model. It is found that the present experimental profile is in better agreement with the RFA calculations if the outer electronic configuration is chosen as 5d3.26s0.8. The cohesive energy of Hf is also deduced from the experimental data and is compared with the available data. On leave from Hindu College, Sonepat 131 001, India  相似文献   

2.
Anil Gupta  B K Sharma  B L Ahuja 《Pramana》1988,31(3):225-232
The results of a Compton profile study on polycrystallineα-Mn are reported. Our measurement are compared with theoretical results computed for different 3d-4s electron configurations within the RFA model. Best agreement between the measured and calculated values is found for 3d 5·44s 1·6 configuration. Theoretical Compton profile ofγ-Mn calculated using the same procedure is close to that for bcc phase with similar electron configurations.  相似文献   

3.
A longitudinal polarized positron beam is foreseen for the international linear collider (ILC). A proof-of-principle experiment has been performed in the final focus test beam at SLAC to demonstrate the production of polarized positrons for implementation at the ILC. The E166 experiment uses a 1 m long helical undulator in a 46.6 GeV electron beam to produce a few MeV photons with a high degree of circular polarization. These photons are then converted in a thin target to generate longitudinally polarized e + and e . The positron polarization is measured using a Compton transmission polarimeter. The data analysis has shown asymmetries in the expected vicinity of 3.4% and ∼1% for photons and positrons respectively and the expected positron longitudinal polarization is covering a range from 50% to 90%.   相似文献   

4.
A densitometer system, operating in a non-destructive and non-invasive way, is presented to investigate the density and moisture variation in wood samples of Pinus roxburghii (known as chir pine). The inherent ability of Compton scattering can ascertain quantitative information of electron density of the target material. A well collimated beam of 662?keV gamma rays from 137Cs radioactive source has been used to extract the information of density from interior of sample by recording scattered spectra with NaI(Tl) scintillation detector. An inverse matrix approach for unfolding of observed pulse-height distribution to a true photon spectrum is used, by choosing bin mesh (E1/2) of 0.025 (MeV)1/2, for the measurements of scattered spectra. The regression lines, obtained from data of scattered spectra, provide the density and moisture content of selected wood sample. The adjusted R2 value 0.984 for fitted curve, justifies the linear dependence of scattered intensity upon wood density. Also, Compton scatter measurements results that the technique is less sensitive beyond wood thickness of ~110?mm due to overlying scatter components in the measured spectrum.  相似文献   

5.
A novel dual-emitter vacuum Compton detector (D-VCD) with higher gamma ray detecting efficiency is proposed. The emitters are made of Ta--Al clad metal. The gamma ray sensitivity is studied by Monte Carlo simulation using the MCNP code. A comparison between calculations and results measured by using the 1.25~MeV gamma ray of Co-60 is also performed. Experimental sensitivities for two sample D-VCDs with the same materials and structures are 1.92×10^ - 20 and 2.02×10^ - 20~C.cm2/MeV separately, which are consistent with the simulation result of 1.98×10^ - 20~C.cm2/MeV and are 4 times higher than that of VCD with a single Fe emitter. According to the simulation results, in a gamma energy range from 0.5 to 3~MeV, the maximum sensitivity variance for the D-VCD is less than 15%, and less than 5% in a range from 1 to 2~MeV in particular. The novel D-VCD is applicable to the detection of intense pulse gamma rays.  相似文献   

6.
B L Ahuja  B K Sharma  O Aikala 《Pramana》1987,29(3):313-320
Compton profile of cobalt has been calculated employing the renormalized-free-atom model for fcc as well as hcp phases choosing several 3d-4s configurations. The results have been compared with recent gamma-ray measurements on polycrystalline Co. Best agreement between theory and experiment is found for 3d 74s 2 configuration. Comparison with free electron model has also been made for this case.  相似文献   

7.
B L Ahuja  N L Heda 《Pramana》2007,68(5):843-850
In this paper, a new design and construction of a low intensity (100 mCi) 241Am γ-ray Compton spectrometer is presented. The planar spectrometer is based on a small disc source with the shortest geometry. Measurement of the momentum density of polycrystalline Al is used to evaluate the performance of the new design. The measured profile is in good agreement with the existing theoretical data and our density functional calculations.   相似文献   

8.
Clover detector has been used as a Compton polarimeter to measure the linear polarization of γ-rays produced in heavy ion fusion reaction. The polarization sensitivity of the clover detector has been measured over γ-ray energies ranging from 386 to 1368 ke V. The E1 multipolarity of the 1117 keV transition in 99Rh has been established using this polarimeter. This has resulted in the assignment of negative parity to the band head at 3710 keV in 99Rh.  相似文献   

9.
The scattering and absorption differential cross sections for nonlinear QED process such as double photon Compton scattering have been measured as a function of independent final photon energy. The incident gamma photons are of 0.662 MeV in energy as produced by an 8 Ci137Cs radioactive source and thin aluminum foils are used as scatterer. The two simultaneously emitted photons in this process are detected in coincidence using two Nal(T1) scintillation detectors and a slow-fast coincidence set-up of 30 nsec resolving time. The measured values of scattering and absorption differential cross sections agree with theory within experimental estimated error.  相似文献   

10.
The effective compton cross section in a non-degenerate plasma (n?{((kT/c)2+2mkT)/h2}3/2) is investigated in a wide range of temperatures. The results show a decreasing behavior with temperatures especially for kT?mec2. The results may be important in phenomena like accretion discs or ultra-relativistic blast waves in GRB models, where the emitted radiation has to pass through a medium containing high-energy electrons.  相似文献   

11.
B. L. Ahuja  M. Sharma 《Pramana》2005,65(1):137-145
In this paper, we present the design and construction of a 20 Ci γ-ray Compton spectrometer that employs a137 Cs source with a strong line at 661.65 keV. The total resolution of the spectrometer in momentum scale is 0.40 a.u., which is much better than the conventional241Am Compton spectrometers. The in-house137Cs spectrometer is very useful for the measurement of momentum densities of heavy materials. The performance of the machine is assessed using aluminum, terbium and mercury samples and the experimental data from comparable apparatus.  相似文献   

12.
We present the first-ever experimental Compton profiles (CPs) of Sc2O3 and Y2O3 using 740 GBq 137Cs Compton spectrometer. The experimental momentum densities have been compared with the theoretical CPs computed using linear combination of atomic orbitals (LCAO) within density functional theory (DFT). Further, the energy bands, density of states (DOS) and Mulliken's population (MP) data have been calculated using LCAO method with different exchange and correlation approximations. In addition, the energy bands, DOS, valence charge density (VCD), dielectric function, absorption coefficient and refractive index have also been computed using full potential linearized augmented plane wave (FP-LAPW) method with revised functional of Perdew–Becke–Ernzerhof for solids (PBEsol) and modified Becke Johnson (mBJ) approximations. Both the ab-initio calculations predict wide band gaps in Sc2O3 and Y2O3. The band gaps deduced from FP-LAPW (with mBJ) are found to be close to available experimental data. The VCD and MP data show more ionic character of Sc2O3 than Y2O3. The ceramic properties of both the sesquioxides are explained in terms of their electronic and optical properties.  相似文献   

13.
Differential cross-sections for quasi-free Compton scattering from the proton and neutron bound in the deuteron have been measured using the Glasgow/Mainz photon tagging spectrometer at the Mainz MAMI accelerator together with the Mainz [48]cm ;SPMOslash; × [64]cm NaI(Tl) photon detector and the G?ttingen SENECA recoil detector. The data cover photon energies ranging from [200]MeV to [400]MeV at θLAB γ = 136.2°. Liquid deuterium and hydrogen targets allowed direct comparison of free and quasi-free scattering from the proton. The neutron detection efficiency of the SENECA detector was measured via the reaction p(γ,π+ n). The “free” proton Compton scattering cross-sections extracted from the bound proton data are in reasonable agreement with those for the free proton which gives confidence in the method to extract the differential cross-section for free scattering from quasi-free data. Differential cross-sections on the free neutron have been extracted and the difference of the electromagnetic polarizabilities of the neutron has been determined to be αn - βn = 9.8±3.6(stat)+2.1 -1.1(syst)±2.2(model) in units of [10-4]fm 3. In combination with the polarizability sum αn + βn = 15.2±0.5 deduced from photoabsorption data, the neutron electric and magnetic polarizabilities, αn = 12.5±1.8(stat)+1.1 -0.6(syst)±1.1(model) and βn = 2.7±1.8(stat)+0.6 -1.1(syst)±1.1(model) are obtained. The backward spin polarizability of the neutron was determined to be γ(n) π = (58.6±4.0)×10-4 fm 4. Received: 21 August 2002 / Accepted: 16 October 2002 / Published online: 11 February 2003 RID="a" ID="a"Part of the Doctoral Thesis. RID="b" ID="b"Present address: Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig. RID="a" ID="a"Part of the Doctoral Thesis. RID="b" ID="b"Present address: Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig. RID="c" ID="c"Part of the Habilitation Thesis. RID="d" ID="d"e-mail: schumacher@physik2.uni-goettingen.de Communicated by Th. Walcher  相似文献   

14.
Virtual Compton scattering off the proton has been studied at Q 2 = 0.33 (GeV/c)2 at the MAMI accelerator in Mainz (Germany). The goal of the experiment is to measure the generalized polarizabilities (GPs) of the proton using the double polarized e pe' p'γ reaction. This paper reports the measurement of the unpolarized photon electroproduction cross-section for the new data and the extraction of two linear combinations of GPs, which are essential for the analysis of the double spin asymmetry.  相似文献   

15.
The Compton scattering on a charged pion and the process γγ→π0π0 are studied using the dispersion relations. Unknown parameters of the S-wave ππ interaction and a sum and a difference of the π0 meson polarizabilities are found from a fit to the experimental data for the γγ→π0π0 process. The found parameters of the ππ interaction are used for the calculation of the cross section of the elastic γπ± scattering. The analysis of the obtained results shows that the experimental data for the elastic γπ± scattering in the energy region up to 1 GeV together with the data for the γγ→π0π0 process could be used both for a determination of the pion polarizability values and for study of the S-wave ππ interaction. Received: 20 November 1998 / Revised version: 22 January 1999  相似文献   

16.
The G0 experiment is dedicated to the determination of the strange quark contribution to the electric and magnetic nucleon form factors for a large range of momentum transfers between 0.1 to 1(GeV/c)2 . This information is provided by the asymmetries of cross-sections measured with longitudinally polarized electrons in elastic electron-proton scattering and quasi-elastic electron-deuteron scattering. A set of measurements at two different Q2 will allow the complete separation of the electric and magnetic weak, as well as axial nucleon form factors. This report summarizes the physics case, gives details about the dedicated set-up used, and shows the results of the combination of the strange quark contribution in the electric and magnetic form factors of the protons. The experiment was performed at the Jefferson Laboratory, during years 2003 and 2004, and will be completed after backward-angle measurements in 2006, 2007.  相似文献   

17.
The coherent (Rayleigh) to incoherent (Compton) scattering cross-section ratio of elements, in the range 6 ≤ Z ≤ 82, are determined experimentally for 145 keV incident gamma photons. An HPGe (High purity germanium) semiconductor detector is employed, at scattering angle of 50°, 70° and 90°, to record the spectra originating from interactions of incident gamma photons with the target under investigation. The intensity ratio of Rayleigh to Compton scattered peaks observed in the recorded spectra, and corrected for photo-peak efficiency of gamma detector and absorption of photons in the target and air, along with the other required parameters provides the differential cross-section ratio. The measured values of cross-section ratio are found to agree with theoretical predictions (corresponding to 4.939, 6.704 and 8.264 Å−1 photon momentum transfer) based upon non-relativistic form factor, relativistic form factor, modified form factor and S-matrix theory.  相似文献   

18.
This study is related to Compton scattering of photons from a p-Si sample whose surface charge density distributions are changed by an external electric field. The external electric field intensity in the range 0-75 kV/m was used to change the surface charge density distributions of the sample. The sample surface perpendicular to the electric field was selected as the scattering surface. The p-Si sample was bombarded by 59.5 keV γ-photons emitting from an Am-241 point source. The Compton scattered photons at an angle of 90o were detected by an Si(Li) detector. The Compton scattering intensity suddenly increased with the application of the electric field since the applied electric field distorts both the negatively charged scattering center (free electron, bound electron, ionized acceptor) and the positively charged scattering center (hole) and their momentum distribution in the sample. There is a good third-order polynominal relation between the Compton scattering intensity and the increasing (or decreasing) electric field intensity. The results show that the positively charged scattering centers behave like negatively charged scattering centers, but the latter are slightly more effective than the former in the Compton scattering of γ-rays from the sample in the electric field.  相似文献   

19.
The fundamental performance of microangiography has been evaluated using the S‐band linac‐based inverse‐Compton scattering X‐ray (iCSX) method to determine how many photons would be required to apply iCSX to human microangiography. ICSX is characterized by its quasi‐monochromatic nature and small focus size which are fundamental requirements for microangiography. However, the current iCSX source does not have sufficient flux for microangiography in clinical settings. It was determined whether S‐band compact linac‐based iCSX can visualize small vessels of excised animal organs, and the amount of X‐ray photons required for real time microangiography in clinical settings was estimated. The iCSX coupled with a high‐gain avalanche rushing amorphous photoconductor camera could visualize a resolution chart with only a single iCSX pulse of ~3 ps duration; the resolution was estimated to be ~500 µm. The iCSX coupled with an X‐ray cooled charge‐coupled device image sensor camera visualized seventh‐order vascular branches (80 µm in diameter) of a rabbit ear by accumulating the images for 5 and 30 min, corresponding to irradiation of 3000 and 18000 iCSX pulses, respectively. The S‐band linac‐based iCSX visualized microvessels by accumulating the images. An iCSX source with a photon number of 3.6 × 103–5.4 × 104 times greater than that used in this study may enable visualizing microvessels of human fingertips even in clinical settings.  相似文献   

20.
New measurements of photoionization cross-sections of the lithium isotopes are reported employing a Time of Flight (TOF) mass spectrometer in conjunction with an atomic beam apparatus. Using a two-step selective photoionization and saturation technique, we have simultaneously measured the photoionization cross-section of the 2p excited state of both the isotopes Li6 and Li7 as 15±2.5 Mb and 18 ±2.5 Mb where as the corresponding number densities have been determined as N0≈5.3×1010 atoms/cm3 and N0≈6.2×1011 atoms/cm3 respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号