首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
A gas chromatographic (GC) method with mass spectrometric (MS) detection is developed and validated for the accurate and precise determination of octadecenedioic acid (C18:1 DIOIC) in human skin samples and transdermal perfusates. C18:1 DIOIC is extracted using methanol. The saturated analogue 1,18-octadecanedioic acid (C18:0 DIOIC) is added as internal standard. Prior to analysis, both compounds are converted to their trimethylsilylated derivatives using N,O-bis(trimethylsilyl)trifluoroacetamide with 15% trimethylchlorosilane. Quantitation is performed in selected ion monitoring mode with a limit of quantitation of 250 ng/mL. Linearity with a correlation coefficient of 0.998 is obtained over a concentration range of 250-2000 ng/mL. Values for within-day accuracy range from 94.5% to 102.4%, and from 97.5% to 105.8% for between-day accuracy. Within- and between-day precision values are better than 5% and 7%, respectively. The recovery values from the various matrices vary from 92.6% to 104.0%. The GC-MS method is employed for the determination of C18:1 DIOIC after application of an emulsion containing the active ingredient onto human skin in vitro. The results demonstrate that the method is suitable for the determination of C18:1 DIOIC in human skin samples and transdermal perfusates.  相似文献   

2.
Bilal Yilmaz  Sakir Arslan 《Talanta》2009,80(1):346-8122
A sensitive and efficient method was developed for determination of metoprolol in human plasma by gas chromatography-mass spectrometry (GC-MS). Metoprolol and atenolol (internal standard, IS) were extracted from human plasma with a mixture of ethylacetate and diethylether at basic pH with liquid-liquid extraction. Calibration curves were linear over the concentration range 15-500 ng/ml. Intra- and inter-day precision values for metoprolol in human plasma were less than 6.4, and accuracy (relative error) was better than 8.8%. The analytical recovery of metoprolol from human plasma averaged 91.20%. The limits of detection (LOD) and quantification (LOQ) of metoprolol were 5.0 and 15 ng/ml, respectively. Also the developed and validated GC-MS method was successfully applied to three patients with hypertension who had been given an oral tablet of 100 mg metoprolol.  相似文献   

3.
A sensitive and efficient method was developed for the determination of atenolol in human urine by gas chromatography-mass spectrometry (GC-MS). Atenolol and metoprolol (internal standard, IS) were extracted from human urine with a mixture of chloroform and butanol at basic pH with liquid-liquid extraction. The extracts were derivatized with N-Methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) and analyzed by GC-MS using a capillary column. The standard curve was linear (r = 0.99) over the concentration range of 50-750 ng/mL. Intra- and inter-day precision, expressed as the relative standard deviation were less than 5.0%, and accuracy (relative error) was better than 7.0%. The analytical recovery of atenolol from human urine has averaged 91%. The limit of quantification was 50 ng/mL. Also, the method was successfully applied to a patient with hypertension who had been given an oral tablet of 50 mg atenolol.  相似文献   

4.
A sensitive and selective method for the determination of alpha-cyclodextrin in human plasma is described using beta-cyclodextrin as an internal standard. After protein precipitation with perchloric acid, the analytes were isolated from human plasma by solid-phase extraction on Bond Elut C18 cartridges. The compounds were chromatographed on a narrow-bore aminopropyl column (125 x 2 mm i.d., 5 microm) and analyzed by electrospray ionization mass spectrometry in the positive selected-ion mode using the [M+NH4]+ ion. The lower limit of quantitation was 5 ng ml(-1) of human plasma. Linear calibration curves were obtained over the concentration range 5-1000 ng ml(-1) of human plasma. The intra- and inter-assay precisions were <18% and the accuracy was <10.5% over the entire concentration range. During the method development, the ionization efficiencies of the analytes in plasma samples originating from different sources were examined to overcome the matrix effect problems caused by co-eluting endogenous compounds. The method was successfully applied to pharmacokinetic studies in human volunteers.  相似文献   

5.
A sensitive and rapid liquid chromatography/electrospray ion trap mass spectrometry (LC/MS/MS) method has been developed for the quantitative determination of medroxyprogesterone acetate (MPA) in human plasma. Plasma samples (1.0 mL) were simply extracted with pentane and the extracts were analyzed by HPLC with the detection of the analyte in the selective reaction monitoring (SRM) mode. The determination of MPA was accurate and reproducible, with a limit of quantitation of 0.05 ng/mL in plasma. The standard calibration curve for MPA was linear (r = 0.998) over the concentration range 0.05-6.0 ng/mL in human plasma. Analysis precision over the concentration range of MPA was lower than 18.8% (relative standard deviation, RSD) and accuracy was between 96.2 and 108.7%.  相似文献   

6.
A selective and sensitive method for the determination of piritramide in human plasma is described. A 1-ml aliquot of plasma was extracted with 10 ml of hexane-isoamyl alcohol (99.5:0.5, v/v) (extraction efficiency 86%) after addition of 50 microliters of 2 M ammonia and 20 microliters of aqueous strychnine solution (100 ng per 10 microliters) as internal standard. Gas chromatography was performed with J&W DB-1, 30 m x 0.53 mm I.D. separation column, film thickness 1.5 microns, using an nitrogen-phosphorus-sensitive detector. The assay was linear in the concentration range 3.75-2250 ng/ml (r = 0.999), with a lower limit of detection of 1-2 ng/ml. The precision was determined using spiked plasma samples (10 and 50 ng/ml), with coefficients of variation of 3.5 and 3.1% (intra-day; n = 5) and 4.6 and 4.1% (inter-day; n = 4). In the range 3.75-150 ng/ml, the accuracy of the assay was 3.36%. The method was used for the determination of piritramide plasma concentrations in patients receiving intra- or post-operative analgesia.  相似文献   

7.
提出了气相色谱-串联质谱法测定稻米中毒死蜱及其代谢物3,5,6-三氯-2-羟基吡啶(TCP)含量的方法。样品经含体积分数为1%盐酸的乙腈提取,盐析并浓缩至近干后,残渣用乙酸乙酯溶解TCP用N-甲基-N-叔丁基二甲基硅基三氟乙酰胺衍生化,用气相色谱-串联质谱法测定,外标法定量。毒死蜱及TCP的质量浓度与峰面积均在0.02~0.4mg.L-1范围呈线性关系,测定下限(10S/N)依次为0.5,0.2μg.kg-1。在3个浓度水平下进行了回收和精密度试验,毒死蜱和TCP的回收率分别在94.3%~111.9%和95.1%~109.6%范围内,相对标准偏差(n=5)分别在1.7%~4.0%和3.1%~11.6%范围内。  相似文献   

8.
An analytical method for the simultaneous determination of codeine, morphine and 6-acetylmorphine (6AM) in human oral fluid was developed. The method involves liquid-liquid extraction in Toxitubes A, derivatization with 99:1 (v/v) N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA)/trimethylchlorosilane (TMCS), and gas chromatography/mass spectrometry with positive chemical ionization (GC/PCI-MS) determination. The detector response was linear over the concentration range 30-500 ng/mL with coefficients of correlation higher than 0.99. The precision was acceptable with coefficients of variation less than 7.5%. The limits of detection achieved were 0.7 ng/mL for codeine, 2.0 ng/mL for morphine, and 0.6 ng/mL for 6AM. The method proposed was applied to 80 oral fluid samples from opiates users, 98% of which were positive for the three analytes. Human oral fluid is a suitable biological fluid for the determination of opiates by GC/PCI-MS.  相似文献   

9.
A simple, sensitive and reproducible high-performance liquid chromatographic method for detecting and quantifying saquinavir in human plasma is described. Verapamil was used as internal standard. The method employes a single liquid-liquid extraction step with tert-butil methyl ether followed by chromatography on a Lichrospher 60 Select B C8 reversed-phase column. Ultraviolet detection was used to identify the compounds of interest. The quantitation limit of saquinavir was 1 ng/mL and only 0.5 mL of plasma sample was required for the determination. The average saquinavir recoveries over a concentration range of 2.5-500 ng/mL ranged from 86 to 95%. Precision and accuracy did not exceed 5%.  相似文献   

10.
Choi MH  Chung BC 《The Analyst》1999,124(9):1297-1300
An efficient method for the simultaneous determination of eight steroids, androstenedione, dihydrotestosterone (DHT), dehydroepiandrosterone (DHEA), testosterone, androsterone, etiocholanolone, progesterone and pregnenolone, in human hair by gas chromatography-mass spectrometry (GC-MS) using d3-testosterone as internal standard is described. The method involves alkaline digestion, liquid-liquid extraction and subsequent conversion to mixed pentafluorophenyldimethylsilyl-trimethylsilyl (flophemesyl-TMS) derivatives for sensitive analysis in the selected ion monitoring (SIM) mode. This method showed good overall repeatability and reproducibility of 4.88-11.24 and 3.19-9.58%, respectively. For the first time, the quantification of DHT, DHEA and pregnenolone in human hair has been achieved by GC-MS, testosterone was also quantified. The detection of four steroids in hair samples was possible in the concentration range 0.12-8.45 ng g-1. The other four steroids, androstenedione, androsterone, etiocholanolone and progesterone, were not detected. The detection limits for SIM of the steroids varied in the range 0.02-0.5 ng g-1, and the SIM responses were linear with correlation coefficients varying from 0.991 to 0.996 for most of the steroids studied. The concentrations of the four steroids detected were different in male and female hair samples.  相似文献   

11.
A method for the determination of trace amounts of the herbicide oxadiazon was developed using headspace solid-phase microextraction (HS-SPME), gas chromatography-mass spectrometry (GC-MS) and selected ion monitoring. It was applied to determine oxadiazon in ground water, agricultural soil, must, wine and human urine samples. To determine oxadiazon in liquid samples, a response surface methodology generated with a Doehlert design was applied to optimize the HS-SPME conditions using a 100 microm polydimethylsiloxane fibre. For the analysis of soil samples, they were mixed with water and the SPME fibre suspended in the headspace above the slurry. Ground water, human urine and must show linear concentration range of application of 0.5-50 ng ml(-1)' with detection limits < or =0.02 ng ml(-1). HS-SPME-GC-MS analysis yielded good reproducibility (RSD values between 6.5 and 13.5%). The method validation was completed with spiked matrix samples. The developed analytical procedure is solvent free, cost effective and fast.  相似文献   

12.
This work describes two high-performance liquid chromatographic methods for the individual determination of bisoprolol and metoprolol in human plasma. Analytical methods involve two different liquid-liquid extractions of human plasma, with diethyl ether for bisoprolol and with dichloromethane for metoprolol, coupled with a similar Nucleosil C(18) reversed-phase HPLC column. Fluorimetric detection was used to identify both beta-blockers. Retention times for bisoprolol and metoprolol were 8.7 and 3.2 min, respectively. Linear regressions for the calibration curves were linear at a concentration range of 6.25-200 ng/mL. Intra- and inter-day precision coefficients of variations and accuracy bias were acceptable (within 15%) over the entire range for both drugs. Average recovery was 89% for metoprolol and 98% for bisoprolol. Once the methods had been validated, analytical error functions were established as standard deviation (SD; ng/mL) = 2.216 + 3.608 x 10(-4)C(2) (C = theoretical concentration value) and SD-(ng/mL) = 0.408 + 0.378 x 10(-1)C for bisoprolol and metoprolol, respectively. The methods developed and their associated analytical error functions will be suitable for pharmacokinetic studies and for determination of plasma concentration if posology individualization of these drugs is needed.  相似文献   

13.
A highly sensitive thermospray liquid chromatographic-mass spectrometric method has been developed for the simultaneous determination of FRC-8653 (I), a new calcium antagonist, and its main metabolite (M-4) in plasma. A deuterated analogue of I was added to the plasma as the internal standard. After the purification and concentration of the plasma sample on bonded-phase disposable columns, the extract was injected into the thermospray liquid chromatograph and analysed by selected-ion monitoring mass spectrometry. The calibration curves obtained were linear over the concentration range 0.5-100 ng/ml. The limits of quantification are 0.5 ng/ml for I and 1 ng/ml for M-4 in plasma, which are sufficient to evaluate plasma concentrations after oral administration to rats.  相似文献   

14.
A sensitive and rapid method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) combined with rapid solid-phase extraction (SPE) has been developed and validated for the quantitative determination of enalapril and its active metabolite enalaprilat in human plasma. After addition of internal standard to human plasma, samples were extracted by 96-well SPE cartridge. The extracts were analyzed by HPLC with the detection of the analyte in the multiple reaction monitoring (MRM) mode. This method for the simultaneous determination of enalapril and enalaprilat was accurate and reproducible, with respective limits of quantitation of 0.2 and 1.0 ng/mL in plasma. The standard calibration curves for both enalapril and enalaprilat were linear (r(2) = 0.9978 and 0.9998) over the concentration ranges 0.2-200 and 1.0-100 ng/mL in human plasma, respectively. The intra- and inter-day precision over the concentration range for enalapril and enalaprilat were lower than 13.3 and 15.4% (relative standard deviation, %RSD), and accuracy was between 89.2-105.0 and 91.9-104.7%, respectively.  相似文献   

15.
A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (MS/MS) method was developed and validated for the assay of tizanidine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the selected reaction monitoring mode. The assay exhibited a linear dynamic range of 50-5000 pg/mL for tizanidine in human plasma. The lower limit of quantification was 50 pg/mL with a relative standard deviation of less than 13%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

16.
CPT-11 (I; 7-ethyl-10-[4-(1-piperidino)-1- piperidino]carbonyloxycamptothecin) is a new anticancer agent currently under clinical development. A sensitive high-performance liquid chromatographic assay suitable for the simultaneous determination of I and its active metabolite SN-38 (II) in human plasma, and their preliminary clinical pharmacokinetics, are described. Plasma samples were processed using a solid-phase (C18) extraction step allowing mean recoveries of I, II and the internal standard camptothecin (III) of 84, 99 and 72%, respectively. The extracts were chromatographed on a C18 reversed-phase column with a mobile phase composed of acetonitrile, phosphate buffer and heptanesulphonic acid, with fluorescence detection. The calibration graphs were linear over a wide range of concentrations (1 ng/ml-10 micrograms/ml), and the lower limit of determination was 1 ng/ml for both I and II. The method showed good precision: the within-day relative standard deviation (R.S.D.) (5-1000 ng/ml) was 13.0% (range 4.9-19.4%) for I and 12.8% (6.7-19.1%) for II; the between-day R.S.D. (5-10,000 ng/ml was 7.9% (5.4-17.5%) for I and 9.7% (3.5-15.1%) for II. Using this assay, plasma pharmacokinetics of both I and II were simultaneously determined in three patients receiving 100 mg/m2 I as a 30-min intravenous infusion. The mean peak plasma concentration of I at the end of the intravenous infusion was 2400 +/- 285 ng/ml (mean +/- standard error of the mean). Plasma decay was triphasic with half-lives alpha, beta and gamma of 5.4 +/- 1.8 min, 2.5 +/- 0.5 h and 20.2 +/- 4.6 h, respectively. The volume of distribution at steady state was 105 +/- 15 l/m2, and the total body clearance was 12.5 +/- 1.9 l/h.m2. The maximum concentrations of the active metabolite II reached 36 +/- 11 ng/ml.  相似文献   

17.
A highly sensitive and convenient gas chromatographic-mass spectrometric (GC-MS) method is described for the determination of 5-fluorouracil in the presence of 2'-deoxy-5-fluorouridine (which breaks down into 5-fluorouracil during ordinary GC derivatization) in biological samples such as plasma and urine. After extraction with ethyl acetate, 5-fluorouracil and 5-chlorouracil, the latter being used as an internal standard, were converted into their tert.-butyldimethylsilyl derivatives by allowing the mixture to stand for 30 min at room temperature and were assayed by electron-impact ionization GC-MS. Under these conditions, 2'-deoxy-5-fluorouridine did not decompose or interfere with the determination of 5-fluorouracil. The assay method, including the extraction and tert.-butyldimethylsilyl derivatization of 5-fluorouracil, showed good linearity in the range 0-100 ng/ml for 5-fluorouracil in plasma (detection limit 0.5 ng/ml) and urine (detection limit 1 ng/ml). The usefulness of this method was demonstrated by determining plasma concentrations of 5-fluorouracil in rats treated intravenously with 5-fluorouracil and 2'-deoxy-5-fluorouridine.  相似文献   

18.
A rapid, sensitive and selective determination of delta 9-tetrahydrocannabinol (THC) in human plasma, serum and saliva was developed with high-performance liquid chromatography with electrochemical detection. Initially, samples were deproteinized, followed by a one step liquid-liquid extraction. Samples were measured by high-performance liquid chromatography with electrochemical detection with 4-dodecylresorcinol as the internal standard. The minimal detectable limit for THC in biological samples was ca. 1 ng/ml with a signal-to-noise ratio greater than 3, corresponding to an on-column sensitivity for THC of ca. 0.5 ng. The detector was operated at + 0.90 V vs. Ag/AgCl and exhibited linearity over a concentration range of 1-150 ng/ml with correlation coefficients of the standard curves greater than 0.99.  相似文献   

19.
ICI 204,636 (I) is an orally active antipsychotic agent under development for the treatment of schizophrenia in humans. It is partially converted in animals to an active 7-hydroxy metabolite (II). Methods were developed for the simultaneous determination of both analytes in human plasma using high-performance liquid chromatography (HPLC) and gas chromatography-mass spectrometry (GC-MS). The analytes were extracted from plasma using phenyl solid-phase extraction columns. Quantification by isocratic HPLC was performed in the reversed-phase mode with detection at 250 nm. Extracts were derivatized to trimethylsilyl ethers for quantification by GC-MS using selected-ion monitoring. Both assays were evaluated for consistency of response, precision, accuracy and specificity. Limits of quantification for I and II by HPLC were 15 and 20 ng/ml, respectively; limits of quantification for I and II by GC-MS were 2 and 5 ng/ml, respectively. Both methods were applied to the analysis of clinical samples from oral dosing studies with I.  相似文献   

20.
N-(n-Propyl)-N-(4-pyridinyl)-1H-indol-1-amine hydrochloride (HP 749, I), a non-receptor-dependent cholinomimetic agent with noradrenergic activity, is a potential agent for the treatment of Alzheimer's disease. Pharmacokinetic studies in animals and humans showed that I was well absorbed and metabolized primarily to the N-despropyl metabolite (P7480, II) after oral administration. To facilitate the kinetic studies, a sensitive and selective high-performance chromatographic assay was developed. I and II are extracted from plasma by a mixture of cyclohexane-ethyl acetate and chromatographed on an isocratic reversed-phase high-performance liquid chromatographic system employing an analytical phenyl column with acetonitrile-ammonium formate as mobile phase. The concentrations of these two compounds, quantitated by internal standardization, are monitored by ultraviolet detection. The method is linear in the plasma assay over a concentration range of 0.5-500 ng/ml for both compounds with a quantitation limit of 0.5 ng/ml. The precision and accuracy of the calibration curves and/or method are less than 10%. The recovery of I and II from plasma is 63-74 and 63-68%, respectively, over a concentration range of 0.5-500 ng/ml.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号