首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper describes the use of double-pulse laser ablation to improve ICP-MS internal (temporal relative standard deviation, %TRSD) and external (%RSD) precision. The first laser pulse is used to ablate a large quantity of mass from the sample surface. The second pulse is applied with a variable time delay after the first pulse to break the ablated mass into a finer aerosol, which is more readily transported to and digested in the ICP-MS. A factor of two improvement in %TRSD and factor of five in %RSD are demonstrated.  相似文献   

2.
The paper describes the application of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for the isotopic analysis of individual uranium-oxide particles. The procedure developed is suitable for the accurate measurement of 234U, 235U, 236U and 238U isotopes in single actinide particles with lateral dimensions down to 10 μm. The 235U/238U isotope ratios can be obtained with a precision of a few percent relative standard deviation using a single collector ICP-MS instrument. The precision could be improved by the use of slow ablation and by taking several LA-ICP-MS replicate spectra on the same particle investigated. For the minor isotopes use of higher mass resolution (R = 4000) was necessary in some cases to avoid spectral interferences. The technique developed offers a rapid and accurate possibility for the isotopic composition determination of uranium-containing individual particles in environmental and safeguards samples.  相似文献   

3.
Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science. ICP-MS is used for the sensitive determination of trace and ultratrace elements in digested solutions of solid samples or of process chemicals (ultrapure water, acids and organic solutions) for the semiconductor industry with detection limits down to sub-picogram per liter levels. Whereas ICP-MS on solid samples (e.g. high-purity ceramics) sometimes requires time-consuming sample preparation for its application in materials science, and the risk of contamination is a serious drawback, a fast, direct determination of trace elements in solid materials without any sample preparation by LA-ICP-MS is possible. The detection limits for the direct analysis of solid samples by LA-ICP-MS have been determined for many elements down to the nanogram per gram range. A deterioration of detection limits was observed for elements where interferences with polyatomic ions occur. The inherent interference problem can often be solved by applying a double-focusing sector field mass spectrometer at higher mass resolution or by collision-induced reactions of polyatomic ions with a collision gas using an ICP-MS fitted with collision cell. The main problem of LA-ICP-MS is quantification if no suitable standard reference materials with a similar matrix composition are available. The calibration problem in LA-ICP-MS can be solved using on-line solution-based calibration, and different procedures, such as external calibration and standard addition, have been discussed with respect to their application in materials science. The application of isotope dilution in solution-based calibration for trace metal determination in small amounts of noble metals has been developed as a new calibration strategy. This review discusses new analytical developments and possible applications of ICP-MS and LA-ICP-MS for the quantitative determination of trace elements and in surface analysis for materials science.  相似文献   

4.
The particle size distribution in laser ablation inductively coupled plasma mass spectrometry is known to be a critical parameter for complete vaporization of particles. Any strategy to reduce the particle size distribution of laser generated aerosols has the potential to increase the ion signal intensity and to reduce fractionation effects. Due to the fact that vapor generation, nucleation, condensation, and agglomeration take place within an extremely short period of time, ablation under atmospheric pressure might not allow influencing these processes while under reduced pressure condition the cooling of the aerosol and therefore the condensation is expected to be slower. In this study, a low pressure laser ablation cell for the generation of laser aerosols was coupled to an ICP-MS. In contrast to the previously developed trapped ablation mode, the newly designed cell allows the adjustment of the pressure in the ablation cell between 20 and 1400 mbar prior to the ablation.Ablation experiments carried out using this configuration showed a dependence of the aerosol properties (size distribution and particle structure) on the ablation cell pressure. The intensity ratio U/Th measured as a figure of merit for complete vaporization within the ICP indicated a change in the aerosol structure at approximately 500 mbar toward smaller particle size. A significant difference between low pressure and at ambient pressure ablated aerosol was observed. The intensity ratios (U/Th) of the ablated sample moves closer to the bulk composition at lower pressures at the expense of sensitivity. Therefore the decrease in the ICP-MS signal intensity in the low pressure cell can be attributed to vapor deposition within the ablation cell walls.Moreover, scanning electron microscope images of aerosols collected on filters after the low pressure ablation cell suggest the possibility of a slower cooling velocity of the aerosol, which was observed in the condensed material on the surface of ejected spherical particles. The expansion of the laser aerosol was also investigated using polished brass substrates in the expansion path-way for particle collection.  相似文献   

5.
The major challenge to the use of laser ablation sample introduction, combined with inductively coupled plasma mass spectrometry, is the problem of calibration. In the geological analysis of minerals, calibration is complicated by the extraordinarily wide variety of sample matrices which may be encountered. While there is a lack of mineral standards with well characterized concentrations near 1 g/g, the NIST glass reference materials (SRM 610–617) have been demonstrated to be very useful for the analysis of a wide variety of lithophile elements in silicate samples. An internal reference element, for which the concentration is known in the sample, has been widely used to make corrections for the multiplicative effects of volume (or weight) of the sample ablated, instrument drift, and matrix effects. This procedure works extremely well where elements being determined and the internal reference element being used share similar ablation behaviours; i.e., they do not fractionate progressively during the ablation and transport process. In this study, it is demonstrated that, in terms of ablation behaviour, elements fall into several distinct clusters and that the elements within these clusters correlate well with each other during a period of ablation. Thus, elements within a cluster can be determined using an internal reference element from within the same cluster. While a combination of periodic varying properties typifies the clusters, the geochemical classification of elements into lithophile (silicate loving), and chalcophile (sulphide loving) appears to offer the best characterization of the major groups.  相似文献   

6.
The major challenge to the use of laser ablation sample introduction, combined with inductively coupled plasma mass spectrometry, is the problem of calibration. In the geological analysis of minerals, calibration is complicated by the extraordinarily wide variety of sample matrices which may be encountered. While there is a lack of mineral standards with well characterized concentrations near 1 microg/g, the NIST glass reference materials (SRM 610-617) have been demonstrated to be very useful for the analysis of a wide variety of lithophile elements in silicate samples. An internal reference element, for which the concentration is known in the sample, has been widely used to make corrections for the multiplicative effects of volume (or weight) of the sample ablated, instrument drift, and matrix effects. This procedure works extremely well where elements being determined and the internal reference element being used share similar ablation behaviours; i.e., they do not fractionate progressively during the ablation and transport process. In this study, it is demonstrated that, in terms of ablation behaviour, elements fall into several distinct clusters and that the elements within these clusters correlate well with each other during a period of ablation. Thus, elements within a cluster can be determined using an internal reference element from within the same cluster. While a combination of periodic varying properties typifies the clusters, the geochemical classification of elements into lithophile (silicate loving), and chalcophile (sulphide loving) appears to offer the best characterization of the major groups.  相似文献   

7.
The dependence of analyte sensitivity and vaporization efficiency on the operating parameters of an inductively coupled plasma mass spectrometer (ICPMS) was investigated for a wide range of elements in aerosols, produced by laser ablation of silicate glass. The ion signals were recorded for different carrier gas flow rates at different plasma power for two different laser ablation systems and carrier gases. Differences in atomization efficiency and analyte sensitivity are significant for the two gases and the particle size distribution of the aerosol. Vaporization of the aerosol is enhanced when helium is used, which is attributed to a better energy-transfer from the plasma to the central channel of the ICP and a higher diffusion rate of the vaporized material. This minimizes elemental fractionation caused by sequential evaporation and reduces diffusion losses in the ICP. The sensitivity change with carrier gas flow variation is dependent on m/z of the analyte ion and the chemical properties of the element. Elements with high vaporization temperatures reach a maximum at lower gas flow rates than easily vaporized elements. The sensitivity change is furthermore dependent on m/z of the analyte ion, due to the mass dependence of the ion kinetic energies. The mass response curve of the ICPMS is thus not only a result of space charge effects in the ion optics but is also affected by radial diffusion of analyte ions and the mismatch between their kinetic energy after expansion in the vacuum interface and the ion optic settings.  相似文献   

8.
In this study we developed a dried-droplet method for laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method provides accurate and precise results when building calibration curves and determining elements of interest in real liquid samples. After placing just 1 μL of a liquid standard solution or a real sample onto the filter surface and then converting the solution into a very small, thin dry spot, the sample could be applied as an analytical subject for LA. To demonstrate the feasibility of this proposed method, we used LA-ICP-MS and conventional ICP-MS to determine the levels of 13 elements (Li, V, Mn, Co, Ni, Cu, Zn, As, Mo, Cd, Sb, Tl, and Pb) in five water samples. The correlation coefficients obtained from the various calibration curves ranged from 0.9920 (205Tl) to 0.9998 (51V), sufficient to allow the determination of a wide range of elements in the samples. We also investigated the effects of Methylene Blue (MB) and the NaCl concentration on the elemental analyses. MB could be used as an indicator during the ablation process; its presence in the samples only negligibly influenced the intensities of the signals of most of the tested elements. Notably, high NaCl contents led to signal suppression for some of the elements. In comparison with the established sample introduction by nebulization, our developed technique abrogates the need for time-consuming sample preparation and reduces the possibility of sample contamination.  相似文献   

9.
Of all the inorganic mass spectrometric techniques, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) plays a key role as a powerful and sensitive microanalytical technique enabling multi- element trace analysis and isotope ratio measurements at trace and ultratrace level. LA-ICP-MS was used to produce images of detailed regionally-specific element distribution in 20 microm thin sections of different parts of the human brain. The quantitative determination of copper, zinc, lead and uranium distribution in thin slices of human brain samples was performed using matrix-matched laboratory standards via external calibration procedures. Imaging mass spectrometry provides new information on the spatially inhomogeneous element distribution in thin sections of human tissues, for example, of different brain regions (the insular region) or brain tumor tissues. The detection limits obtained for Cu, Zn, Pb and U were in the ng g(-1) range. Possible strategies of LA-ICP-MS in brain research and life sciences include the elemental imaging of thin slices of brain tissue or applications in proteome analysis by combination with matrix-assisted laser desorption/ionization MS to study phospho- and metal- containing proteins will be discussed.  相似文献   

10.
Journal of Radioanalytical and Nuclear Chemistry - The 6th Collaborative Materials Exercise, CMX-6, was organized by the Nuclear Forensic International Technical Working Group in 2018 and 2019. Two...  相似文献   

11.
A laser ablation setup including outer chamber, sample tube, sample holder and transport tubing was modelled and optimized using advanced computational fluid dynamics techniques. The different components of the setup were coupled and the whole device was modelled at once. The mass transport efficiency and transit times of near infrared femtosecond (fs) laser generated brass aerosols in pure argon and helium–argon mixtures were calculated at experimentally optimized conditions and a transient signal was constructed. The use of helium or argon did not influence the mass transport efficiency, but the signal structure changed. The signal fine structure was retrieved and experimentally validated. Bimodal peak structures were observed that seemed to originate from turbulent effects in the tubing connecting a Y-connector and the injector.  相似文献   

12.
The applicability of laser ablation (LA) inductively coupled plasma (ICP) spectrometry for assessing elemental distributions in layered ceramics was investigated and compared with electron probe microanalysis (EPMA). Ordinary glazed wall tiles were employed as model specimens due to their defined structure and composition. They were used for calibration in the analysis of ancient pottery. A qualitative depth profile was acquired by single-spot laser drilling perpendicular to coatings with a Nd:YAG (1064 nm) laser coupled with an ICP optical emission spectrometer (OES). The lower lateral resolution associated with the laser spot diameter of 1.0 mm led to smoothing of the depth profile due to the averaging of local irregularities. In addition, transverse line scans by ablation across the tile section using an ArF* (193 nm) laser coupled with an ICP mass spectrometer (MS) were performed. LA-ICP-OES depth profiles and LA-ICP-MS transverse scans were validated by EPMA section scans and 2D back-scattered electrons images. The LA-ICP-OES acquisition was less dependent on sample surface and layer irregularities, whereas the transverse line scan over the tile section with the small-spot beam offered insight into the micromorphology of the individual layer. The combined approach revealed the occurrence of individual mineral grains, micro-heterogeneities and the character of interfaces between layers.  相似文献   

13.
This paper is a summary of the current knowledge of laser-generated aerosols under atmospheric conditions. It is restricted to typical laser sampling conditions as they are used in LA-ICP spectrometry. Published experimental evidence and proposed models are reviewed and critical summarized. The collected works show that a certain agreement exists that independently of the sample two size fractions with different chemical composition are found. The mechanism generating the different particle fractions are currently not clear. Possible sources of particle generation are described and critically reviewed. Fundamentally three distinguishable modes (gas, liquid, solid) can be described that can appear: gas-to-particle conversion, hydrodynamic sputtering, mechanical spallation/exfoliation. More recently explosive boiling as a mechanism of liquid expulsion has been discussed as a further possible source under certain conditions. Particle conditioning during transport is discussed as a source for agglomeration. The correlation between size distribution and laser parameters is discussed.  相似文献   

14.
A method of controlling the focus position of the ablating laser was evaluated. This system consists of a displacement measuring unit based on the triangulation displacement measurement principle. A simple preliminary experimental setup with a light source (LED, light emitting diode) and a displacement-sensor (PSD, position sensing detector) with optics and a electronic circuit, resulted in a reproducibility of a given lateral position of ±5 μm. A fine-tuning of the components, as well as the use of a laser diode as a light source will certainly improve this value.  相似文献   

15.
Coedo AG  Padilla I  Dorado MT 《Talanta》2005,67(1):136-143
Element determination in solid waste products from the steel industry usually involves the time-consuming step of preparing a solution of the solid. Laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS) has been applied to the analysis of Cr, Ni, Cu, As, Cd and Sn, elements of importance from the point of view of their impact on the environment, in electric arc furnace flue dust (EAFD). A simple method of sample preparation as pressed pellets using a mixture of cellulose and paraffin as binder material was applied. Calibration standards were prepared spiking multielement solution standards to a 1:1 ZnO + Fe2O3 synthetic matrix. The wet powder was dried and mechanically homogenised. Quantitative analysis were based on external calibration using a set of matrix matched calibration standards with Rh as a internal standard. Results obtained using only one-point for calibration without matrix matched, needing less time for standardization and data processing, are also presented. Data are calculated for flue dust reference materials: CRM 876-1 (EAFD), AG-6203 (EAFD), AG-6201 (cupola dust) and AG-SX3705 (coke ashes), and for two representative electrical arc furnace flue dusts samples from Spanish steelmaking companies: MS-1 and MS-2. For the reference materials, an acceptable agreement with certificate values was achieved, and the results for the MS samples matched with those obtained from conventional nebulization solutions (CN). The analytical precision was found to be better than 7% R.S.D. both within a single pellet and between several pellets of the same sample for all the elements.  相似文献   

16.
Wet-milling protocol was employed to produce pressed powder tablets with excellent cohesion and homogeneity suitable for laser ablation (LA) analysis of volatile and refractive elements in sediment. The influence of sample preparation on analytical performance was also investigated, including sample homogeneity, accuracy and limit of detection. Milling in volatile solvent for 40 min ensured sample is well mixed and could reasonably recover both volatile (Hg) and refractive (Zr) elements. With the exception of Cr (−52%) and Nb (+26%) major, minor and trace elements in STSD-1 and MESS-3 could be analysed within ±20% of the certified values. Comparison of the method with total digestion method using HF was tested by analysing 10 different sediment samples. The laser method recovers significantly higher amounts of analytes such as Ag, Cd, Sn and Sn than the total digestion method making it a more robust method for elements across the periodic table. LA-ICP-MS also eliminates the interferences from chemical reagents as well as the health and safety risks associated with digestion processes. Therefore, it can be considered as an enhanced method for the analysis of heterogeneous matrices such as river sediments.  相似文献   

17.
Detection efficiencies of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), defined as the ratio of ions reaching the detector and atoms released by LA were measured. For this purpose, LA of silicate glasses, zircon, and pure silicon was performed using nanosecond (ns) as well as femtosecond (fs) LA. For instance, ns-LA of silicate glass using helium as in-cell carrier gas resulted in detection efficiencies between approximately 1E-7 for low and 3E-5 for high mass range elements which were, in addition, almost independent on the laser wavelength and pulse duration chosen. In contrast, the application of argon as carrier gas was found to suppress the detection efficiencies systematically by a factor of up to 5 mainly due to a less efficient aerosol-to-ion conversion and ion transmission inside the ICP-MS.  相似文献   

18.
19.
Hui-Fang Hsieh 《Talanta》2009,79(2):183-240
This work describes a simple procedure for blood lead level determination. The proposed method requires little sample pretreatment and subsequent direct analysis of a dried blood spot on a filter membrane using laser ablation coupled with inductively coupled plasma mass spectrometry (LA-ICP-MS). In general, LA-ICP-MS studies are somewhat limited by the lack of matrix-matched standards for calibration purposes. Here we describe aqueous standard calibration and matrix-matched calibration methods. This method was validated by analysis of the reference materials. With the matrix-matched calibration method, the recovery ranged from 97.8% to 112.8%, while the aqueous standard calibration method ranged 90.4% to 122.4%. The lower detection limit was estimated as 0.1 ng mL−1. The determination precision, expressed as the relative standard deviation (RSD), was not worse than 10% for all results. A sample throughput of approximately 5 min per sample made it possible to rapidly screen a large number of samples.  相似文献   

20.
Many tasks in bulk analysis, micro analysis and depth profile analysis can be solved advantageously by laser ablation inductively coupled plasma mass spectrometry (Laser ICP-MS) in particular, when both the chemical and elemental distributions in the sample are to be determined. However, the analyst has to take into account that the analytical precision and accuracy of the Laser ICP-MS is influenced decisively by signal standardization, the homogeneity of the samples as well as calibration standards and the mass-spectrometric measuring mode, which is usually sequential when performed with scanning mass spectrometers such as quadrupol- or sector-based instruments. Using the ablated mass as standard, an excellent level of the analytical precision and accuracy (relative standard deviation R.S.D.<0.5%) has been obtained for homogeneous sample materials such as alloys. For inhomogeneous samples, such as pressed pellets, a statistical test is described, which is based upon the auto-correlation function to characterize the sample inhomogeneity. The application of the test allows us to calculate the representative mass for the quantitative analysis at previously defined analytical precision. In the instrumental part of the paper a new type of an ICP—time-of-flight (TOF) mass spectrometer—is described, constructed and built up in our laboratory. For fast signal counting an application-specific integrated circuit (ASIC) was developed, which permits a time resolution of 1 ns. The analytical performance of the TOF when used in combination with an ICP is demonstrated in terms of resolution, ion extraction rate, detection limits and dynamic range. The determination of 39K+ and 40Ca+ at trace level can be realized in a cool plasma condition (high central gas flow) only with a small interference by 40Ar+. Detection limits of 23 elements were measured with typical values in the lower nanograms per liter range. The ion extraction rates, measured for a sample mass of 1 ng in terms of counts per second divided by the relative isotope abundance, are one order of magnitude higher than those obtained with a quadrupol-based instrument.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏