首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An LC-ESI-MS method was developed and validated for the assay of apomorphine in canine plasma using one-step liquid-liquid extraction. The analytes were separated on a Phenomenex Gemini C18 (150 mm x 2.0 mm id 3 microm) column and determined by MS in the positive ion mode. The linear range was 0.4-40 ng/mL with an LOD of 0.2 ng/mL for apomorphine in plasma. The intraday and interday precision and accuracy of quality control samples were < 5.9% RSD and < 7.5% bias for apomorphine. Extraction recoveries were > 80%. The validated method was successfully applied to analyze canine plasma samples in a pharmacokinetic study of apomorphine in dogs and detailed pharmacokinetic parameters were calculated.  相似文献   

2.
3.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

4.
A simple, sensitive and rapid high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the assay of granisetron in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 313/138 for granisetron and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 0.1-20 ng/mL for granisetron in human plasma. The lower limit of quantification was 100 pg/mL with a relative standard deviation of less than 5%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

5.
A method for the quantification of clindamycin in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS/MS) is presented. Lincomycin is used as the internal standard. The sample preparation includes a simple deproteinization step with trichloroacetic acid. Chromatographic separation is achieved on an RP-18 Hypersil column using gradient elution with 0.01 M ammonium acetate and acetonitrile as mobile phase. Good linearity was observed in the range 0-10 microg ml(-1). The limit of quantification of the method is 50 ng ml(-1) and the limit of detection is 1.3 ng ml(-1). The method was shown out to be of use for pharmacokinetic studies of clindamycin formulations in dogs.  相似文献   

6.
Interaction of carboplatin with cytochrome c (Cyt. c) has been investigated by electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry (MS/MS). ESI-MS studies revealed that the ring-opened adducts of carboplatin with Cyt. c were formed in the stoichiometric ratio of 1:1 and 2:1 at pH 5.0 and 37 degrees C and in the stoichiometric ratio of 1:1 only at pH 7.0 and 37 degrees C. It was also found that Cyt. c could be cleaved by carboplatin at pH 2.5 and 50 degrees C. The cleaved fragments of Cyt. c were determined by ESI-MS and MS/MS analysis to be Glu66 approximately Met80, Ac-Gly01 approximately Met65, Glu66 approximately Glu104, Ac-Gly01 approximately Met80 and Ile81 approximately Glu104. The carboplatin prefers to anchor to Met65 first, then to Met80. To further confirm the binding site of Met, AcMet-Gly was used as the model molecule to investigate its interaction with carboplatin and its hydrolysis reaction. On the basis of species detected during the reaction monitored by ESI-MS, a possible pathway of the cleavage reaction was proposed.  相似文献   

7.
A novel, sensitive and specific method for the quantitative determination of ivermectin B(1a) in animal plasma using liquid chromatography combined with positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is presented. Abamectin was used as the internal standard. Extraction of the samples was performed with a deproteinization step using acetonitrile. Chromatographic separation was achieved on a Nucleosil ODS 5 microm column, using gradient elution with 0.2% (v/v) acetic acid in water and 0.2% (v/v) acetic acid in acetonitrile. The method was validated according to the requirements defined by the European Community. Calibration curves using plasma fortified between 1 and 100 ng ml(-1) showed a good linear correlation (r > or = 0.9989, goodness-of-fit coefficient < or =8.1%). The trueness at 2 and 25 ng ml(-1) (n = 6) was +4.2 and -17.1%, respectively. The trueness and between-run precision for the analysis of quality control samples at 25 ng ml(-1) was -4.0 and 11.0%, respectively (n = 16). The limit of quantification of the method was 1.0 ng ml(-1), for which the trueness and precision also fell within acceptable limits. Using a signal-to-noise ratio of 3 : 1, the limit of detection was calculated to be 0.2 ng ml(-1). The specificity was demonstrated with respect to ivermectin B(1b).The method was successfully used for the quantitative determination of ivermectin B(1a) in plasma samples from treated bovines, demonstrating the usefulness of the developed method for application in the field of pharmacokinetics.  相似文献   

8.
Disulfide polymers obtained by ring‐opening polymerization have been considered to have a possibility of a cyclic catenane structure as judged from their test properties on the loss modulus and stress–strain. Electrospray ionization mass spectrometry (ESI‐MS) was used to detemine molecular structure of polydithiane and polyoxyethylene to find whether they are present as a cyclic or as a linear structure. The results indicated that the polydithiane possesses the cyclic structure, and analysis of the isotope distribution of the spectral ions further showed that the polymer consists entirely of the cyclic structure without contamination of a linear polymer. A linear chain polymer with a benzylmercaptan end group was synthesized, and the ESI‐MS analysis revealed that the polymer was a mixture of both the cyclic and the linear polymer. The cyclic polymer is probably formed by back‐biting of the highly reactive sulfur radicals that had been formed during the polymerization reaction. © 2000 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 38: 4403–4406, 2000  相似文献   

9.
A mass spectrometric-based procedure for anthocyanin profiling was set up to distinguish authentic Vitis vinifera from hybrid red grapevine cultivars. 3-O-Monoglucoside and the related acetyl-, p-coumaryl- and caffeoyl-monoglucoside anthocyanins occurred only in Vitis vinifera, whereas 3,5-O-diglucoside and the substituted acetyl-, p-coumaryl-, feruloyl- and caffeoyl-diglucoside anthocyanins were the additional pigments in hybrid grapevines. The procedure was applied expressly to identify red grape cultivars based on the anthocyanin chemo-type determination. In particular, a red grape cultivar, having 3,5-O-diglucoside anthocyanins and a novel class of anthocyanin monoglucosides, such as cyanidin-3-O-, cyanidin-3-O-(6-O-acetyl)- and cyanidin-3-O-(6-O-p-coumaryl)pentoside, was classified as hybrid. A second vine cultivar, characterized exclusively by 3-O-monoglucoside anthocyanins, was included among the Vitis vinifera species. Anthocyanin profiling by mass spectrometry could represent the core of a chemotaxonomic procedure for distinguishing American and European grapevines based on the identification of post-synthetic anthocyanidin modification.  相似文献   

10.
Single nucleotide polymorphisms (SNPs) are currently being mapped and databased at a remarkable pace, providing a viable means for understanding disease susceptibility, differential drug response and human evolution. Consequently, there is an increasing demand for SNP genotyping technologies that are simple, rapid, cost effective and readily amenable to automation for high-throughput analyses. In this study, we improved the Survivor Assay, a SNP detection method based on electrospray ionization mass spectrometry (ESI-MS), with several developments. One improvement is the development of a one-well assay, requiring no off-line purification of the polymerase chain reaction product, achieved by simple addition of reagent solution into a single well. Another is the on-line separation of magnesium and dideoxynucleotides using an in-house made monolithic metal chelating column, eliminating any off-line sample preparation prior to mass spectrometric analysis. Here the Survivor Assay is extended from a proof-of-principle concept to a validated method by genotyping six SNPs from five different regions of human genomic DNA in 55 individual samples with 100% accuracy. This improved Survivor Assay eliminates the tedious and time-consuming steps of sample preparation, minimizes sample handing and offers a high-throughput analysis of SNPs by ESI-MS. The current combined preparation and analysis time is 2 min per sample. The simplicity of this method has potential for full automation and parallel chromatography and, thus, reduced analysis time. In addition, we have adapted the Survivor Assay for quantitative SNP analysis in pooled DNA samples. The capabilities and sensitivity of this approach were evaluated. We demonstrate that an allele occurring at a frequency of 2% can consistently be quantitated.  相似文献   

11.
The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports.  相似文献   

12.
A method based on the analysis of trimethylsilyl (TMS) derivatives by capillary gas chromatography electrospray ionization mass spectrometry (GC–ESI/MS) was proposed. To improve separation, analytes were derivatized to their TMS derivative. During ESI analysis, TMS derivatives may hydrolyze back to their polar native form and are thus suitable for ESI analysis. Several types of analytes were studied to investigate the potential of the approach. Not all TMS derivatives hydrolyzed back to their native form as anticipated. Incomplete hydrolysis was observed for TMS‐organic acids and TMS‐nonchlorinated phenols. For TMS‐chlorophenols, the observation of only the [M ? H]? ion suggested that these phenols were hydrolyzed back to their native form. For TMS‐beta agonists, the hydrolysis rate was low; therefore, the hydrolysis product was not detected. Both TMS‐chlorophenols and TMS‐beta agonists provide a sensitivity in the range of low parts per billion (0.25–5 ng/ml and 0.5–10 ng/ml respectively). Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
Hitherto analysis of chemicals in the field using mass spectrometry (MS) has been limited to analysis of non-polar and thermally stabile organic compounds using either a direct gas leak or a membrane inlet as MS interface. Recently, Professor R. Graham Cooks’ group demonstrated that miniature mass spectrometers operating at elevated pressures (>0.13?Pa (1?·?10?3??Torr)) can be combined with electrospray ionization (ESI) for analysis of polar as well as thermally labile organic compounds. We present a simple miniaturized ESI unit for analysis of small liquid samples using miniature mass spectrometry. The ESI unit operates without pumps and supplementary sheath gases, which makes it very simple to handle in the field. 20–30?µL of sample solution is simply dropped into a small cavity in the ESI unit, where after the spray is initiated by applying high voltage to it. The miniaturized ESI unit was tested in combination with a miniature mass spectrometer (the Mini 10 developed by Professor R. Graham Cooks, Purdue University, IN) and we found that common herbicides (Atrazine, Prometryne, Terbutryne and Triadimefone) could be detected with detection limits around 1?mg?L?1 and with a quantitative reproducibility of +/?30%. These characteristics, although high for environmental samples, are comparable to detection limits obtained with other ESI units used with miniature mass spectrometers and represent an early step forward towards a future field instrument. A major advantage of the capillary spray cell is its direct compatibility with micro extraction techniques for sample pre-concentration.  相似文献   

14.
In this study, rapid quantitative detection of histamine in beer was achieved by using nano extractive electrospray ionization mass spectrometry (nano EESI‐MS) coupling with standard addition method. Based on the MS2 experiment, histamine concentrations in three beer samples were determined to be 1.10 ± 0.12 µg/ml, 0.81 ± 0.09 µg/ml and 0.79 ± 0.09 µg/ml. The limit of detection for this method was calculated to be 0.02 µg/ml. These results show that this novel method can be used for direct, rapid and sensitive detection of histamine in beer without any tedious sample pretreatment. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
The aim of this study was to develop a rapid and sensitive method for the quantification of cefquinome in animal plasma and bronchoalveolar lavage (BAL) fluid using high-performance liquid chromatography combined with electrospray tandem mass spectrometry (LC-ESI-MS/MS). Cefadroxil is used as internal standard. For plasma, the sample preparation includes a simple deproteinization step with a Microcon filter. This allows detecting the unbound cefquinome concentration, which is correlated with the concentration in other body fluids, such as BAL fluid. To be able to detect the total plasma concentration, deproteinization with acetonitrile, followed by a back-extraction of actonitrile with dichloromethane was performed. The BAL fluid is centrifuged to precipitate floating particles. Chromatographic separation is achieved on a PLRP-S column using 0.005% formic acid and methanol as mobile phase. For plasma, good linearity was observed in the range of 5-2500 ng ml(-1) for both the unbound and total concentration. The response in BAL fluid was linear in the range of 4-1000 ng ml(-1). The limit of quantification (LOQ) was set at 5.00 ng ml(-1) for plasma and at 4.00 ng ml(-1) for BAL fluid. The limit of detection (LOD) was 3.12 ng ml(-1) and 0.41 ng ml(-1) for the unbound and total concentration in plasma, respectively, and was 1.43 ng ml(-1) for BAL fluid. The method was shown to be of use in a pharmacokinetic study in pigs, where the correlation between cefquinome concentrations in plasma and BAL fluid of pigs was studied.  相似文献   

16.
The reactions of ethyl pyruvate with acetic anhydride and pyridine were studied by electrospray ionization mass spectrometry (ESI-MS). Ethyl 2-acetoxy-2-pyridiniumpropionate (1) (m/z 238) resulting from the reaction of the acetylpyridinium cation with ethyl pyruvate, and the adduct of ethyl 2-acetoxyacrylate with a pyridinium cation (2), bound together by non-covalent interactions (m/z 238), were identified by ESI-MS for the first time. Structures 1 and 2 cannot be distinguished, probably because one may be converted into the other and vice versa.  相似文献   

17.
Novel methods for the determination of inorganic oxyanions by electrospray (ES) ionization mass spectrometry have been developed using dehydration reactions between oxyanions and carboxylic acids at the ES interface. Twelve oxyanions (VO3?, CrO42?, MoO42?, WO42?, BO33?, SiO32?, SiO44?, AsO44?, AsO2?, SeO42?, SeO32? and NO2?), out of 16 tested, reacted with at least one of four aminopolycarboxylic acids, i.e. iminodiacetic acid (IDA), nitrilotriacetic acid (NTA), trans‐1,2‐diaminocyclohexane‐N,N,N′,N′‐tetraacetic acid and triethylenetetramine‐N,N,N′,N″,N′″,N′″‐hexaacetic acid, at the ES interface to produce the dehydration products that gave intense mass ion responses, sufficient for trace analysis. As examples, trace determinations of CrVI and silica in water samples were achieved after online ion exchange chromatography, where the dehydration product of CrO42? and NTA (m/z 290) and that of SiO44? and IDA (m/z 192) were measured. The limits of detection of the respective methods were 17 nM (0.83 ng Cr/ml) for CrVI and 0.17 μM (4.8 ng Si/mL) for SiO44?. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

18.
19.
Peroxidation catalysed by Soybean Lypoxigenase was performed on tetralinoleyl-cardiolipin with the aim of generating selectively oxidized products, to be used subsequently as standards for studies on cardiolipin oxidation. The reaction products were characterized by LC-ESI-MS and MS/MS, and the process was found to link a hydroperoxylic group on one or more linoleic chains of cardiolipin, up to a total of four groups per molecule. Interestingly, the incidence of other oxidized products, like those arising from multiple hydroxylation or mixed hydroxylation-hydroperoxydation, previously observed after the chemical oxidation of the same cardiolipin, was found to be negligible. Moreover, evidences for the presence of the hydroperoxylic group(s) almost exclusively on carbon 13 of the linoleic chain(s) were obtained by MS/MS measurements. The enzymatic approach, integrated with a preparative separation step, which could be developed by adapting the chromatographic conditions adopted in the present work for analytical purposes, represents a promising strategy for the synthesis of highly specific mono- or multi-peroxidated derivatives of cardiolipins.  相似文献   

20.
A sensitive and specific liquid chromatographic–electrospray ionization mass spectrometric method was developed for quantification of salvianolic acid B in rat plasma with resveratrol as the internal standard. The analytes were separated on a reversed‐phase column with acetonitrile (40%) and water (60%) containing 0.75% formic acid as mobile phase at a flow rate of 1 mL/min. Liquid–liquid extraction was adopted for the sample preparation, and the analytes were determined using electrospray negative ionization mass spectrometry in the selective monitoring mode. The method was validated over the concentration range 0.1–40 µg/mL using 0.1 mL of plasma with coefficients of correlation >0.999. The intra‐ and inter‐day precisions of analysis were <10%, and accuracy ranged from 94 to 101%. This method was successfully applied to a pharmacokinetics of salvianolic acid B in rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号