首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
王宁  李永仙  郑飞云  刘春凤  李崎  顾国贤 《色谱》2009,27(3):372-375
采用Waters Sep-Pak C18固相萃取小柱对啤酒样品进行分离纯化,建立了啤酒中黄腐酚的固相萃取-高效液相色谱检测方法。选用色谱柱Zorbax Eclipse XDB-C18柱(250 mm×4.6 mm,5 μm),以甲醇和0.1%甲酸水溶液为流动相进行梯度洗脱,柱温25 ℃,流速0.4 mL/min,检测波长370 nm。在此条件下,黄腐酚分离良好且无杂质峰干扰,在0.5~500 μg/L的范围内线性关系良好(r21),在高、中、低浓度下的加标回收率为91.21%~95.58%,相对标准偏差小于2%。方法的检出限为0.24 μg/L,定量限为0.80 μg/L。该方法简便快速、结果准确、重现性好,是检测啤酒中黄腐酚含量的有效方法。  相似文献   

2.
A rapid technique based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography (DMAE-SPE-HPLC) has been developed. A TM010 microwave resonance cavity built in the laboratory was applied to concentrate the microwave energy. The sample placed in the zone of microwave irradiation was extracted with 95% acetonitrile (ACN) aqueous solution which was driven by a peristaltic pump at a flow rate of 1.0 mL min−1. The extraction can be completed in a recirculating system in 10 min. When a number of extraction cycles were completed, the extract (1 mL) was diluted on-line with water. Then the extract was loaded into an SPE column where the analytes were retained while the unretained matrix components were washed away. Subsequently, the analytes were automatically transferred from the SPE column to the analytical column and determined by UV detector at 238 nm. The technique was used for determination of organochlorine pesticides (OCPs) in grains, including wheat, rice, corn and bean. The limits of detection of OCPs are in the range of 19-37 ng g−1. The recoveries obtained by analyzing the four spiked grain samples are in the range of 86-105%, whereas the relative standard deviation (R.S.D.) values are <8.7% ranging from 1.2 to 8.7%. Our method was demonstrated to be fast, accurate, and precise. In addition, only small quantities of solvent and sample were required.  相似文献   

3.
C18-functionalized magnetic microspheres synthesized in a three-stage system and characterized by Fourier transform infrared (FTIR) spectroscopy and SEM were applied for clean-up and enrichment of polycyclic aromatic hydrocarbons (PAHs) in soil samples combined with ultrasonication extraction. Magnetic solid-phase extraction (MSPE) parameters, such as elution solvents, amounts of sorbents, enrichment time and organic modifier, were optimized together with ultrasonication time and extraction solvents. Under the optimal conditions, the developed method provided spiked recoveries of 63.2-92.8% with RSDs of less than 6.4% and limits of detection were 0.5-1.0 ng/g. This new method provides several advantages, such as high extraction efficiency, convenient extraction procedure and short analysis times. Finally, the method was successfully applied to the determination of polycyclic aromatic hydrocarbons in soil samples.  相似文献   

4.
石芳  寿旦  金米聪  王宏伟  陈旭光  朱岩 《色谱》2022,40(2):139-147
随着麻醉剂广泛用于渔业生产过程和水产品运输等领域,建立水产品中麻醉剂残留的检测方法具有重要意义.由于水产品基质复杂且麻醉剂残留水平低,因此需要合适的前处理方法以提高检测灵敏度.该研究基于分散固相萃取-高效液相色谱,建立了一种同时检测水产品中普鲁卡因、丁氧卡因、三卡因、丁香酚、甲基丁香酚、异丁香酚、甲基异丁香酚7种麻醉剂...  相似文献   

5.
固相萃取-高效液相色谱检测葡萄酒中赭曲霉毒素A   总被引:7,自引:0,他引:7  
使用C18小柱固相萃取, C18反相柱(250 mm×4.6 mm i.d.)分离,V(乙腈):V(水):V(乙酸)=99:99:2为流动相,荧光检测器(激发波长333 nm,发射波长460 nm)检测,测定葡萄酒中赭曲霉毒素A.其质量浓度在6.25~200 ng/mL范围内呈良好线性,相关系数为0.9997.样品经浓缩60倍后,方法检出限为0.027 ng/mL.对红葡萄酒、干红及白葡萄酒进行了加标回收实验,回收率为80.1%~109.8%.平行7份样品加标回收率相对标准偏差为5.9%.对市售6种葡萄酒进行了赭曲霉毒素A的测定.  相似文献   

6.
An HPLC method with an evaporative light scattering detector was optimized and validated for quantification of carbohydrates in beer. The chromatographic separation was achieved using a Spherisorb NH2, 5 microm chromatographic column and gradient elution with acetonitrile/water. The determinations were performed in the linear range of 0.05-5.0 g/L for fructose, 0.05-5.0 g/L for glucose, 0.05-15.0 g/L for maltose, 0.05-10.0 g/L for maltotriose, and 0.05-5.0 g/L for maltotetraose. The detection limits were 0.005 g/L for fructose, 0.008 g/L for glucose, and 0.01 g/L for maltose, maltotriose, and maltotetraose. The reliability of the method in terms of precision and accuracy was evaluated in three beer matrices, low alcohol beer, 6% alcohol beer, and beer made with part of adjuncts (4.5% alcohol). Relative standard deviations (RSDs) ranged between 1.59 and 5.95% (n = 10), and recoveries ranged between 94 and 98.4%.  相似文献   

7.
A procedure based on solid-phase extraction (SPE) followed by high-performance liquid chromatography (HPLC) with diode array detection has been developed for the simultaneous analysis of 16 widely used pesticides in groundwater samples. The compounds analysed were: aldicarb, atrazine, desethylatrazine, desysopropylatrazine, carbofuran, 2,4-D, dicloran, fenitrothion, iprodione, linuron, metalaxyl, metazachlor, phenmedipham, procymidone, simazine and vinclozolin. Five different SPE sorbents, C18 bonded silica (Isolute SPE C18 (EC)), graphitised carbon black (Superclean Envi-Carb), highly cross-linked polystyrene-divinylbenzene (Lichrolut EN), divinylbenzene-N-vinylpyrrolidone (Oasis HLB) and surface modified styrene-divinylbenzene (Strata X), were compared. HPLC separation and quantification of the selected pesticides was carried out under isocratic conditions by means of a new reversed-phase column (Gemini from Phenomenex) based on C18 bonded to organic-silica particles. Oasis HLB and Strata X provided the best results in the preconcentration of 1-l samples, yielding average recoveries higher than 70%, except for phenmedipham that rapidly degrades in groundwater. Detection limits of the target pesticides provided by the proposed SPE-HPLC procedure were between 0.003 and 0.04 μg l−1.  相似文献   

8.
The synthesis and evaluation of a molecularly imprinted polymer (MIP) as a selective matrix solid-phase dispersion (MSPD) sorbent, coupled with high-performance liquid chromatography for the efficient determination of chloramphenicol (CAP) in fish tissues are studied. The polymer was prepared using CAP as the template molecule, vinylpyridine as the functional monomer and ethylene glycol dimethacrylate as the cross-linking monomer, and sodium dodecyl sulfate as the surfactant in the presence of water as a solvent by miniemulsion polymerization. The CAP-imprinted polymers and nonimprinted polymers (NIPs) were characterized by Fourier transform IR spectroscopy, scanning electron microscopy, and static adsorption experiments. The CAP-imprinted material prepared showed high adsorption capacity, significant selectivity, and good site accessibility. The maximum static adsorption capacity of the CAP-imprinted and the NIP material for CAP was 78.4 and 59.9 mg g(-1), respectively. The relative selectivity factors of this CAP-imprinted material were larger than 1.9. Several parameters influencing the MSPD process were optimized. Finally, the CAP-imprinted polymers were used as the sorbent in MSPD to determine CAP in three kinds of fishes and resulted in satisfactory recovery in the range 89.8-101.43%. CAP-imprinted polymer as a sorbent in MSPD is better than C18 and attapulgite in terms of both recovery and percent relative standard deviation. The baseline noise was measured from a chromatogram of a blank fish sample which was treated after the MSPD procedure using CAP-imprinted polymer as a sorbent. Signal values of 3 times the noise (signal-to-noise ratio of 3) and 10 times the noise (signal-to-noise ratio of 10) were used to calculate the limit of detection and the limit of quantitation of the calibration curve. The limit of detection for CAP was 1.2 ng g(-1) and the limit of quantitation was 3.9 ng g(-1).  相似文献   

9.
In this study, a mixed hemimicelle solid‐phase extraction method based on Fe3O4 nanoparticles coated with sodium dodecyl sulfate was applied for the preconcentration and fast isolation of six fluoroquinolones in environmental water samples before high‐performance liquid chromatography determination. The main factors affecting the extraction efficiency of the analytes, such as amount of surfactant, amount of Fe3O4 nanoparticles, extraction time, sample volume, sample pH, ionic strength, and desorption conditions, were investigated and optimized. The method has detection limits from 0.05 to 0.1 ng/mL and good linearity (r ≥ 09948) in the range 0.1–200 ng/mL depending on the fluoroquinolone. The enrichment factor is ~200. The recoveries (at spiked levels of 1, 5, and 50 ng/mL) are in the range of 79–120%.  相似文献   

10.
Li J  Chen L  Wang X  Jin H  Ding L  Zhang K  Zhang H 《Talanta》2008,75(5):1245-1252
An automated system using on-line solid-phase extraction (SPE) high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was developed for the determination of tetracyclines (TCs), such as tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC), metacycline (MC), and doxycycline (DC) in honey. One milliliter diluted honey sample was injected into a conditioned C18 SPE column and the matrix was washed out with water for 3 min. By rotation of the switching valve, TCs were eluted and transferred to the analytical column by the chromatographic mobile phase. Chromatographic conditions were optimized. TCs were separated in less than 8 min with a gradient elution using a mixture of 0.8% formic acid and acetonitrile. The UV detection was performed at 365 nm. The conditions for on-line SPE, including solvent and total time for loading sample and washing matrix were also optimized. Time for extraction and separation decreased greatly. For the five kinds of TCs, the limits of detection (LODs) at a signal-to-noise of 3 ranged from 5 to 12 ng g−1. The relative standard deviations (R.S.D.) for the determination of TCs ranged from 3.4 to 7.1% within a day and ranged from 3.2 to 8.9% in 3 days, respectively.  相似文献   

11.
Yu QW  Ma Q  Feng YQ 《Talanta》2011,84(4):2989-1025
The silica nanoparticle (SiO2 NP)-deposited capillary fabricated by liquid phase deposition (LPD) was bonded by 3-(triethoxysilyl) propyl methacrylate and then modified with poly(N-isopropylacrylamide) (PNIPAAm) by polymerization. The resulting PNIPAAm modified SiO2 NP-deposited capillary was applied to in-tube solid-phase microextraction coupled to high-performance liquid chromatography (in-tube SPME-HPLC). To investigate the extraction performance of the prepared capillary, diethylstilbestrol (DES) with moderate polarity was selected as the model analyte. Results demonstrate that PNIPAAm modified SiO2 NP-deposited capillary exhibited obvious temperature responsive character. Finally, the PNIPAAm modified SiO2 NP-deposited capillary was applied to the analysis of three synthetical estrogens from milk samples. The detection limit of the method was found to be in the range 1.2-2.2 ng/g, and recovery was 71.7-98.9% with relative standard deviations in the range of 2.8-12.6%.  相似文献   

12.
罗伟强  肖小华  杜卓  李攻科 《色谱》2014,32(4):407-412
建立了整体柱固相萃取-高效液相色谱/紫外检测在线联用方法并用于水果中氯吡脲的分析测定。考察了萃取溶剂的pH值及其流速、溶剂解吸时间及其流速等因素对氯吡脲萃取率的影响。在优化的条件下,该方法对氯吡脲的富集倍数为214倍,方法的线性范围为0.01~50.00 μg/L,检出限为25 ng/L,相对标准偏差(RSD)为3.9%。黑葡萄、猕猴桃和西瓜等水果中氯吡脲的加标回收率为87.0%~120.7%,RSD为0.6%~9.2%。结果表明该方法快速、灵敏,能满足水果中痕量氯吡脲残留分析的要求。  相似文献   

13.
Polyphenolic compounds occurring in hop extracts and their phases I and II metabolites formed during in vivo rat biotransformation have been analyzed using HPLC/MS/MS with electrospray ionization (ESI). Two main groups of polyphenolics are present in the hops, i.e., xanthohumol related compounds and so called α- and β-bitter acids (humulones and lupulones). In our study, hybrid quadrupole-time-of-flight (QqTOF) analyzer is used for the identification of both natural phenolics and their metabolites due to the possibility of accurate mass measurements in full scan and tandem mass spectra supported by MSn data obtained with the ion trap analyzer. Both ESI polarity modes are used for the determination of molecular weights based on [M+H]+ and [M−H] ions in the full scan spectra and the structural information in subsequent tandem mass spectra. The emphasis is given on the elemental composition determination of individual metabolites based on accurate masses typically better than 5 ppm even with the external calibration. Advanced software tools are used for the metabolite identification using the comparison of the blank chromatogram with the real incubation sample together with the software prediction and detection of possible metabolites. Chromatograms of rat incubations are also compared with chromatograms of pure rat feed, rat feed enriched with hop extracts and the placebo experiment. More than ten compounds originating from the hops are identified in rat feces, two of them belong to phase I metabolites and five compounds are phase II metabolites.  相似文献   

14.
A selective and sensitive determination of buspirone in serum by high-performance liquid chromatography is described. The procedure is based on separation on a C18 column. A solid-phase extraction procedure is used for sample clean-up. The retention on the first column is based on the hydrophobic interaction of buspirone with the stationary phase, and the retention on the second column is based on ionic interactions due to the presence of sodium lauryl sulphate in the mobile phase as well as hydrophobic interaction. This allows for good separation of buspirone from impurities and consequently allows lower detection limits than previously reported for liquid chromatographic methods. Detection by ultraviolet absorbance gives a detection limit of 0.2 ng/ml.  相似文献   

15.
A direct method for the determination of piroxicam in plasma is described. Plasma is directly injected onto the extraction column (10 mm x 2 mm I.D., packed with 40-microns Bond Elut C2) where proxicam is separated from the plasma concomitants using a solid-phase extraction procedure. Using a laboratory-made on-line column-switching system, the drug is quantitatively transferred and separated on the analytical column (15 cm x 4.6 mm I.D., Supelcosil LC18 DB, 5 microns) followed by determination using ultraviolet absorption at 331 nm. Validation of the method demonstrated a good recovery (100%), sensitivity (limit of determination 0.2 microgram/ml, based on a 20-microliters sample volume), accuracy and precision (better than 5%). The developed method has been adopted for studying the steady-state pharmacokinetics of the drug.  相似文献   

16.
An improved quality control method was developed to simultaneously determine 15 major constituents (eight flavonoids and seven saponins) in various radix Astragali preparations, using SPE for pretreatment of samples, HPLC with diode-array and evaporative light scattering detectors (DAD-ELSD) for quantification in one run, and HPLC-ESI-TOF/MS for definite identification of compounds in preparations. Optimum separations were obtained with a ZORBAX C(18) column, using a gradient elution with 0.3% aqueous formic acid and ACN. This established method was fully validated with respect to linearity, precision, repeatability, and accuracy, and was successfully applied to quantify the 15 compounds in 19 commercial samples, including 3 dosage forms, i. e., oral solution, injection, concentrated granule, and its processed products of radix Astragali. The results demonstrated that many factors might result in significant differences in quality of the final preparations, including crude drugs, pretreatment processes, manufacturing procedure, storage conditions, etc. Then the developed method provided a reasonable and powerful manner to ensure the efficacy, safety, and batch-to-batch uniformity of radix Astragali products by standardizing each procedure, and thus should be proposed as quality control for the clinical use and modernization of herbal preparations.  相似文献   

17.
The chelating agent EDTA is widely used, and as a result is showing up widely in the aquatic environment. Here we describe a preconcentration procedure for measuring EDTA concentration in sea water samples by HPLC. The procedure consists of forming an Fe(III) complex followed by solid-phase extraction using an activated carbon cartridge. After the preconcentration, EDTA was quantified by HPLC with ultraviolet detection (260 nm). The enrichment permitted the determination of EDTA at concentrations as low as 1 nM. Good recoveries were obtained for both brackish and full-strength sea water with high repeatability (RSD < 6%). The method was applied to sea water samples taken from near the mouth of the Oyabe River in Japan.  相似文献   

18.
A rapid and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for determination of myrislignan in rat plasma after intravenous administration. The analytes extracted from plasma samples by solid-phase extraction were successfully carried out on a Diamonsiltrade mark ODS C(18) column (250 x 4.6 mm i.d., 5 microm) with an RP(18) guard column (8 x 4.6 mm i.d., 5 microm) and a mobile phase of MeOH-H(2)O (4:1, v/v). The UV detector was set at a single wavelength of 270 nm. The linear ranges of the standard curves were 0.5-30.0 microg/mL with the correlation coefficients greater than 0.9992. The lower limits of detection and quantification were 0.1 and 0.3 microg/mL for myrislignan. Intra- and inter-day precisions were 2.4-7.5 and 1.3-5.7%, respectively. The extraction recovery from plasma was more than 90%. This assay method has been successfully used to study the pharmacokinetics of myrislignan in rats.  相似文献   

19.
Multiwalled carbon nanotubes (MWCNTs) were used as a novel kind of solid-phase extraction adsorbents in this work as well as an analytical method based on MWCNTs solid-phase extraction (SPE) combined with high-performance liquid chromatography (HPLC) was established for the determination of polycyclic aromatic hydrocarbons (PAHs), some of which belong to typical persistent organic pollutants (POPs) owing to their carcinogenicity and endocrine disrupting activity. Several conditions that probably affected the extraction efficiency including the eluent volume, sample flow rate, sample pH and the sample volume were optimized in detail. The characteristic data of analytical performance were determined to investigate the sensitivity and precision of the method, and the method was applied to the determination of PAHs in environmental water samples such as river water sample, tap water sample and wastewater sample from the constructed wetland effluent. The experimental results indicated that there were excellent linear relationship between peak area and the concentration of PAHs over the range of 0.04-100 microg L(-1), and the precisions (RSD) were 1.7-4.8% under the optimal conditions. The detection limits of proposed method for the studied PAHs were 0.005-0.058 microg L(-1) (S/N=3). The recoveries of PAHs spiked in environmental water samples ranged from 78.7 to 118.1%. It was concluded that MWCNTs packed cartridge coupled with HPLC was an excellent alternative for the routine analysis of PAHs at trace level.  相似文献   

20.
The potential of eggshell membrane (ESM) as a novel solid-phase extraction bio-adsorbent was investigated in the present study. The ESM with a unique structure of intricate lattice network showed a predominant ability to capture linear alkylbenzene sulfonates (LAS) as a model of organic pollutants by the hydrophobic interactions between ESM and LAS molecular at pH very close to the isoelectric point of ESM, which was similar to the most widely used trapping mechanism for SPE. Under the optimal conditions, the breakthrough capacities of the ESM packed cartridge for C10–C13 LAS homologues were found to be 30, 53, 50, and 43 μg g−1, respectively. On the basis of high-performance liquid chromatography separation and UV detection of LAS homologues, the proposed system could respond down to 0.027 ng mL−1 of LAS with a linear calibration range from 0.2 to 100 ng mL−1, showing a good LAS enrichment ability of eggshell membrane biomaterial with high sensitivity, and could be successfully used for the detection of residual LAS in environmental water samples. The reproducibility among columns was satisfactory (RSD among columns is less than 10%). A comparison study with ESM, C8 and C18 as adsorbents for LAS demonstrated that ESM-based bio-adsorbent was advantageous over C8 and C18, the widely used traditional adsorbents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号