首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work we measured the lead concentration in human bones of Middle Age by means of a portable X-ray fluorescence system based on 109Cd radioactive source. The detection system consists on a Ge hyperpure detector. This system, conceived for in vivo Pb analysis in bone, is portable, non-destructive and is based on lead K lines detection.

The analysed bones are part of two collections of bones both from the end of Middle Age and submitted for some years to a lead polluted burial environment. The bones of one collection were buried initially on the soil in a convent, in Lisbon (Portugal) and further on, kept in a lead coffin for around 100 years. The second collection contains bones buried permanently on the soil around an old church on the south of Portugal. This place became a parking car for around 20 years.

In this work we studied the distribution of Pb in cortical bone, and trabecular regions from the outside surface to the inner part of the bone and the results are compared with the obtained ones by energy dispersive X-ray fluorescence (EDXRF).

The obtained values present a strong contamination of Pb in spongy bones kept in the lead coffin with concentrations ranging from 250 to 350 μg Pb/g bone mineral, and 4 to 7 μg Pb/g bone mineral for bones buried in the soil. Good agreement was observed between the results obtained by the two techniques.  相似文献   


2.
Summary A combined procedure enabling simultaneous multielement analysis of trace impurities in high-purity iron is presented. After removal of the iron matrix by solvent extraction with methyl isobutyl ketone, the trace elements Ti, V, Cr, Mn, Ni, Cu, Pb and Bi are determined by means of total reflection X-ray fluorescence analysis. Detection limits are found in the range of 100 ng/g. The reliability of the method is verified by the analysis of commercial high-purity iron and by the comparison of analytical data obtained by ICP-AES.  相似文献   

3.
Total reflection X-ray fluorescence (TXRF) analysis after the separation of matrix element was studied for the determination of trace impurity elements (Ca, Sc, V, Cr, Mn, Fe, Co, Ni and Zn) in high purity copper. Matrix copper was removed by electrolysis (0.2 A, 8 h) of a nitric acid solution. A 10 μL aliquot of the remaining solution of the electrolysis was dropped on a silicon-wafer sample-carrier and dried in a vacuum. This was repeated five times and the precipitate of five 10 μL-aliquots was analyzed by TXRF using a W-Lβ beam with an incident angle of 0.05?°. TXRF analytical values were obtained by using relative sensitivity factors of the analytes to the internal standard element (Pd). Detection limits of the analytes ranges from 0.077 ng for Zn to 0.785 ng for Ca.  相似文献   

4.
Total reflection X-ray fluorescence (TXRF) analysis after the separation of matrix element was studied for the determination of trace impurity elements (Ca, Sc, V, Cr, Mn, Fe, Co, Ni and Zn) in high purity copper. Matrix copper was removed by electrolysis (0.2 A, 8 h) of a nitric acid solution. A 10 μL aliquot of the remaining solution of the electrolysis was dropped on a silicon-wafer sample-carrier and dried in a vacuum. This was repeated five times and the precipitate of five 10 μL-aliquots was analyzed by TXRF using a W-Lβ beam with an incident angle of 0.05 °. TXRF analytical values were obtained by using relative sensitivity factors of the analytes to the internal standard element (Pd). Detection limits of the analytes ranges from 0.077 ng for Zn to 0.785 ng for Ca. Received: 25 December 1997 / Revised: 30 March 1998 / Accepted: 2 April 1998  相似文献   

5.
The paper describes the analysis of a set of metals in macrozoobenthos samples from a river in Western Austria by using total reflection X-ray fluorescence analysis (TXRF). Metal concentrations in aquatic insect larvae from an industrially contaminated site are significantly higher than in larvae from a reference site. Furthermore, species-specific differences in metal accumulation were found. TXRF allows multi-element analysis of very low metal concentrations in very small sample masses (e.g. single aquatic insect larvae with a dry weight of only a few milligrams). Due to its multi-element capability and high sensitivity total reflection X-ray fluorescence analysis is a valuable tool for biomonitoring studies of metal contamination in aquatic ecosystems.  相似文献   

6.
Uranium has been classified as a toxic chemical. It affects the kidneys, with nephritis being the primarily chemically-induced effect in animals and humans. Intermediate-term studies on animals indicate that increased uranium doses are positively correlated with various biochemical effects and histopathological changes. Since the kidneys efficiently excrete in urine the major portion of solubilized uranium circulating in blood, an increased urinary uranium excretion can provide a sensitive quantitative measure of exposure, especially in the case of acute exposure. In the present work a method was developed for the quantitative determination of uranium in human urine. It combines the chemical treatment of urine, which results in a significant pre-concentration of uranium, with its subsequent detection by means of total reflection X-ray fluorescence (TXRF). The method has been proven to be relatively fast, offering detection limits that allow for monitoring uranium intake above normal levels.  相似文献   

7.
Applicability of Total Reflection X-ray Fluorescence (TXRF) spectrometry for the determination of trace metals at concentration of µg/g level in thorium oxide was studied. The TXRF spectrometer was calibrated using a multielement standard solution and the method was validated by analyzing another multielement standard solution. Sample preparation conditions were optimized for the TXRF determinations of trace metals in thorium oxide. The elements K, Ca, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Sr, Y, Ba and Pb present in thorium oxide standards were determined after dissolving them in HNO3/HF mixture and separating the bulk matrix, thorium, by solvent extraction using tri-n-butyl phosphate (TBP) and tri-n-octyl phosphine oxide (TOPO) as extractants. A comparison of TXRF determined concentrations of trace elements Ca, V, Cr, Mn, Fe, Ni and Cu with the certified values shows that TXRF determined concentrations have an RSD of 20% (1 s for n = 4) and are within an agreement of 20% of the certified values in most of the cases.  相似文献   

8.
The measurement of technetium in inorganic solutions is reported for the first time using total reflection X-ray fluorescence (TXRF). Sodium pertechnetate solutions eluted from decayed 99Mo generators were efficiently excited with a silver-anode X-ray tube in a standard configuration. The technique has been developed to aid establishing the extent of stoichiometric relations between Tc and a ligand in organo-metallic compounds synthesized with diagnostic purposes for nuclear medicine. The precision attained was 5% and the detection limit achieved for Tc in inorganic solutions by TXRF at 1000 s was 0.039 μg/ml.  相似文献   

9.
Total reflection X-ray fluorescence (TXRF) is essential for 300-mm silicon wafer production and fabrication of semiconductor devices. The 300-mm TXRF enables non-destructive contamination analysis on wafers for process development and process control. The TXRF system shows a very stable continuous operation, which allows accurate trace and ultra trace analysis on the silicon surface. It is equipped with two excitation sources covering the requirements of very sensitive measurement and wide element range. The TXRF is a key technology for contamination control during wafer reclaim. For this purpose we show that the system is able to examine the wafers during different processing states of reclaim. The system sensitivity is influenced by the surface of the wafer. For important processing steps, e.g. double side polishing, the sensitivity is as good as for measurements on hazefree polished wafers. We show with TXRF that cross-contamination with copper during double side polishing is suppressed.  相似文献   

10.
X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba).  相似文献   

11.
There is a growing interest in determination of low Z elements, i.e. carbon to phosphorus, in various samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as a suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon).  相似文献   

12.
This paper proposes an optimized method to mark polysaccharide macromolecules with heavy atoms in order to make possible their detection by total reflection X-ray fluorescence. A chemical reaction was employed to produce the substitution of OH groups of the polymer macromolecules by iodine atoms. Temperature, time, concentration of reactants and pH of the labeling chemical reaction were the variables and the relative sensitivities of the introduced atoms in the TXRF determinations were the optimization parameters for the TXRF determinations. Control of the physical properties of the polymer and the labeled product were made in order to prevent chemical alterations. The quantification of the labeled macromolecules was made by a previous careful calibration.  相似文献   

13.
Water soluble polyelectrolyte samples containing mono-, bi- and trivalent metal ions were investigated without any pretreatment. Acid digestion of linear polymers may lead to a product insoluble in water so the digestion has to be avoided. The determination of analytical characteristics and limitations of the total reflection X-ray fluorescence (TXRF) analysis for poly(vinylalcohol-vinylsulfate) copolymers containing the following cations: Cs+; Ba2+; Cu2+ and La3+ are presented in this communication. On the basis of our results efficiency of ion-exchange during preparation of polyelectrolytes and stoichiometry of the end-product were determined. TXRF results were compared with data gained by inductively coupled plasma atomic emission spectrometry (ICP-AES) measurements except in the case of Cs+, which has poor sensitivity in ICP-AES. Good agreement was found between the results of the two techniques and calculations from titrimetric data. Concentration of Li+ and Mg2+ in polymer samples was measured only by ICP-AES.  相似文献   

14.
A study regarding uranium determination in seawater by total reflection X-ray fluorescence (TXRF) spectrometry is reported. Uranium, present in seawater in concentration of about 3.3 ng/mL, was selectively extracted in diethyl ether and determined by TXRF after its preconcentration by evaporation and subsequent dissolution in a small volume of 1.5% suprapure HNO3. Yttrium was used as an internal standard. Before using diethyl ether for selective extraction of uranium from seawater, its extraction behavior for different elements was studied using a multielement standard solution having elemental concentrations in 5 ng/mL levels. It was observed that the extraction efficiency of diethyl ether for uranium was about 100% whereas for other elements it was negligible. The detection limit of TXRF method for uranium in seawater samples after pre-concentration step approaches to 67 pg/mL. The concentrations of uranium in seawater samples determined by TXRF are in good agreement with the values reported in the literature. The method shows a precision within 5% (1σ). The study reveals that TXRF can be used as a fast analytical technique for the determination of uranium in seawater.  相似文献   

15.
Trace elements in tobacco and tobacco smoke by X-ray fluorescence technique   总被引:1,自引:0,他引:1  
Trace elements in tobacco and tobacco smoke of a large number of commonly available brands of cigarettes were analyzed by energy dispersive X-ray fluorescence. This work supplements the data on same samples gathered by INAA and reported earlier. Data on some toxic elements like Pb, Cu and Ni that could not be measured by INAA are presented here. A number of chewing and snuff tobacco samples were also analyzed. The concentrations of Ca, K, Cl, Br, Cu, Fe, Ni, Pb, Rb, Sr, Ti and Zn in all these samples are presented and their relative hazards are discussed.  相似文献   

16.
In clinical service laboratories, one of the most common analytical tasks with regard to inorganic traces is the determination of the nutrition-relevant elements Fe, Cu, Zn, and Se.  相似文献   

17.
The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL1. As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL1 of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 μg g– 1 for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al2O3, powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective samples over a concentration range from 2.5 to 1470 μg g– 1 were found to be 0.995, 0.991 and 0.997, respectively.  相似文献   

18.
Besides photochemical smog, particulate air pollution is a constantly growing problem in urban areas. The particulate matter present in pollution events contains often toxic or health impacting elements and is responsible for low visibility, might be triggering respiratory diseases like asthma, and can play an important role in formation or duration of smog events. To characterize particulate pollution in two different cities, samples were taken during intensive field campaigns in Chicago, IL, in 2002 and Phoenix, AZ, in 2001. Both cities experience regularly photochemical smog events as well as particulate pollution, but show very different meteorological and topographical conditions. Therefore it is expected that the particulate composition varies significantly, providing information about different pollution forms. Sampling took place in both cases at elevated locations and had a temporal resolution of 1.5 h and 1 h, respectively. The samples were analyzed by total reflection X-ray fluorescence after digestion of the filter matrix. As expected the elemental composition of particulate matter varied between both cities substantially with Phoenix showing a higher abundance of crustal elements, and Chicago enrichment in anthropogenically produced ones. In both cities diurnal patterns were found, exerting maxima in the morning and minima in the early afternoon. The diurnal pattern was much more regularly and also more strongly pronounced in Phoenix. Phoenix's valley location permits for a more stable nocturnal boundary layer to build up during the night thus trapping particulates efficiently during this time, until mixing occurs in the early morning hours and the residual layer lifts. In Chicago, the diurnal variation was less extreme, but another pattern determines the situation with the lake breeze. The lake breeze corresponds to a shift in wind direction towards the east, i.e. from Lake Michigan during the late morning. It was found that certain elemental species were enriched during a lake breeze event whereas this was not the case during other days. In conclusion, the low sample mass needed for TXRF analysis and the corresponding short sampling times, permitted the observation and characterization of local meteorological patterns in Phoenix and in Chicago.  相似文献   

19.
Nuclear energy is one of the available energy options for long term energy security of world. In order to produce electricity using this mode of energy generation in an efficient and safe manner, it is necessary that the materials used for such energy generation comply with the specifications assigned. The major and trace composition of these materials is an important specification for their quality control. Different analytical techniques are used for such quality control. Total reflection X-ray fluorescence (TXRF) is a comparatively new technique having several features well suited for trace and major element determinations in nuclear materials. However, this technique has not been used so far extensively for characterization of nuclear materials. The present paper gives a brief introduction of TXRF, its suitability for nuclear material characterization and some details of the TXRF studies made in our laboratory for the characterization of nuclear materials.  相似文献   

20.
A portable total reflection X-ray fluorescence spectrometer was applied to commercial bottled drinking water containing 62 ppb (microg/L) V, 7.5 ppm (mg/L) Ca, and 1 ppm K. A dry residue, prepared by repeated pipetting and drying a 20 microL portion of drinking water on a sample holder six times, and another dry residue, prepared by pipetting and drying a 120 microL portion of the drinking water, were measured. The size of the dry residue of the drinking water was reduced by repeating the pipetting and drying. Calcium and potassium were easily detected in these two dry residues. Vanadium was detected in the dry residue prepared by repeated pipetting and drying. Vanadium, calcium, and potassium were quantified by using an internal standard, and the average quantified concentrations of V, Ca, and K were 91 ppb, 8.2 ppm, and 1.5 ppm, respectively. Although these quantified concentrations deviated from the certified concentrations (62 ppb of V, 7.5 ppm of Ca, and 1 ppm of K), it was possible for this portable spectrometer to estimate approximate concentrations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号