首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Total Reflection X-Ray Fluorescence (TXRF) is a well-established method, mainly applied in the analysis of liquid samples, offering very low detection limits in most of the cases. Direct application of the TXRF method is not so efficient in blood serum analysis, since the high content of the organic matrix increases significantly the background due to Compton scattering. Chemical treatment of the blood serum samples and related preconcentration techniques have been suggested in the literature, but they are time consuming and increase the possibility of adding contaminants in the sample. In this paper, the applicability of direct TXRF analysis in blood serum samples is examined. The insertion of a Mo filter, after the cut-off reflector, has been found to improve significantly the peak-to-background ratio, especially for the elements of interest such as Cu, Zn, Se and Br. The influence of self-absorption phenomena in the quantification procedure was also investigated with respect to the internal standard used and the sample mass analyzed. Precision and accuracy in the analysis was found to be approximately 4% over the whole atomic number range.  相似文献   

2.
Total reflection X-ray fluorescence analysis (TXRF) offers a nondestructive qualitative and quantitative analysis of trace elements. Due to its outstanding properties TXRF is widely used in the semiconductor industry for the analysis of silicon wafer surfaces and in the chemical analysis of liquid samples. Two problems occur in quantification: the large statistical uncertainty in wafer surface analysis and the validity of using an internal standard in chemical analysis. In general TXRF is known to allow for linear calibration. For small sample amounts (low nanogram (ng) region) the thin film approximation is valid neglecting absorption effects of the exciting and the detected radiation. For higher total amounts of samples deviations from the linear relation between fluorescence intensity and sample amount can be observed. This could be caused by the sample itself because inhomogeneities and different sample shapes can lead to differences of the emitted fluorescence intensities and high statistical errors. The aim of the study was to investigate the elemental distribution inside a sample. Single and multi-element samples were investigated with Synchrotron-radiation-induced micro X-ray Fluorescence Analysis (SR-μ-XRF) and with an optical microscope. It could be proven that the microscope images are all based on the investigated elements. This allows the determination of the sample shape and potential inhomogeneities using only light microscope images. For the multi-element samples, it was furthermore shown that the elemental distribution inside the samples is homogeneous. This justifies internal standard quantification.  相似文献   

3.
Multielemental determinations in samples of various types of bee honey, pollen and bee tissue have been carried out using total reflection X-ray fluorescence spectrometry (TXRF) and radioisotope excited X-ray fluorescence spectrometry (XRF). The objective was to establish whether the elemental content of bee honey, in particular, correlates with any useful information about the environment, variety of honey, etc. An attempt has also been made to determine the X-ray techniques' ability to compete with atomic absorption spectrometry (AAS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES), with regard to elemental sensitivity, accuracy, sample preparation procedures, and in particular, economic performance, which is very important in selecting an appropriate technique for the analysis of large numbers of samples. The results confirm the advantages of the TXRF method for trace element analysis, but only when utilising monochromatic excitation and selecting a proper sample preparation procedure. The radioisotope XRF technique, which does not require any sample preparation, is still very competitive in analysis of elements with concentrations above a few ten ppm. Preliminary results also confirm some correlations between the elemental content of honey and the status of the environment, and encourage further work in this direction  相似文献   

4.
建立了微波消解前处理,全反射X射线荧光法(TXRF)同时测定松花粉中K、Ca、Ti、Mn、Fe、Ni、Cu、Zn和Rb9种生命元素含量的分析方法.松花粉原料经过微波消解前处理后,采用全反射X射线荧光光谱净计数、QXAS分析软件解谱和单一内标法进行定量分析.比较了干灰化法、湿消解法和微波消解法3种前处理方法的效果,并确立微波消解法作为样品前处理方法.用微波消解- TXRF法测定了花粉标准物质中的上述9种元素,并计算得到其仪器检出限(LLD)为0.002~0.054 mg/L,方法检出限(LDM)为0.004~0.122 mg/kg.TXRF法测定各元素的相对标准偏差(RSDs)为1.0%~5.5%.该方法操作简单、样品用量少、检出限低,对实际样品松花粉的测定结果与ICP - MS法无显著性差异.  相似文献   

5.
The total reflection X-ray fluorescence (TXRF) method has been used for the analysis of various types of solid materials of biological, geological and environmental origin. The sample preparation step prior to TXRF measurements has been optimized for the various solid samples, including their decomposition by applying both a microwave oven and a PTFE bomb. Complete procedures for the optimized decomposition from the point of view of speed and completeness of digestion, as well as of the overall precision and accuracy are presented.  相似文献   

6.
An intercomparison survey has been carried out in order to evaluate the performance of two related X-ray fluorescence techniques as compared to the achievements of several other analytical techniques applied for trace elements determination in drinking water. A relatively new technique, total reflection X-ray fluorescence (TXRF) and a novel related technique, grazing emission X-ray fluorescence (GEXRF) have been used for the analysis of a mineral water sample. The concentrations of the following elements have been determined: Na, Mg, K, Ca, Ni, Cu, Zn and Sr. The mineral water sample has also been analyzed by a number of other analytical techniques, routinely utilized in drinking water quality control. The analyses were performed in eleven laboratories which reported 286 individual determinations producing 75 laboratory means. From the obtained results, it can be concluded that the TXRF technique is suitable for a direct determination of heavy elements in drinking water (above potassium, Z = 19). This technique can compete with other analytical techniques routinely used in water quality monitoring. First results obtained with GEXRF spectrometry show that this technique can be successfully applied for the determination of low-Z elements in drinking water. However, results for sodium and magnesium were systematically too low, indicating that modifications of the quantification procedure may be required to improve the accuracy of determination for these light elements.  相似文献   

7.
Total Reflection X-ray Fluorescence (TXRF) is a well-established technique for chemical analysis, but it is mainly employed for quality control in the electronics semiconductor industry. The capability to analyze liquid and uniformly thin solid samples makes this technique suitable for other applications, and especially in the very critical field of environmental analysis. Comparison with standard methods like inductively coupled plasma (ICP) and atomic absorption spectroscopy (AAS) shows that TXRF is a practical, accurate, and reliable technique in occupational settings. Due to the greater sensitivity necessary in trace heavy metal detection, TXRF is also suitable for environmental chemical analysis. In this paper we show that based on appropriate standards, TXRF can be considered for non-destructive routine quantitative analysis of environmental matrices such as air filters. This work has been developed in the frame of the EU-FP6 PHIME (Public Health Impact of long-term, low-level Mixed element Exposure in susceptible population strata) Integrated Project (www.phime.org). The aim of this work was to investigate Mn air pollution in the area of Vallecamonica (Italy).  相似文献   

8.
A study regarding uranium determination in seawater by total reflection X-ray fluorescence (TXRF) spectrometry is reported. Uranium, present in seawater in concentration of about 3.3 ng/mL, was selectively extracted in diethyl ether and determined by TXRF after its preconcentration by evaporation and subsequent dissolution in a small volume of 1.5% suprapure HNO3. Yttrium was used as an internal standard. Before using diethyl ether for selective extraction of uranium from seawater, its extraction behavior for different elements was studied using a multielement standard solution having elemental concentrations in 5 ng/mL levels. It was observed that the extraction efficiency of diethyl ether for uranium was about 100% whereas for other elements it was negligible. The detection limit of TXRF method for uranium in seawater samples after pre-concentration step approaches to 67 pg/mL. The concentrations of uranium in seawater samples determined by TXRF are in good agreement with the values reported in the literature. The method shows a precision within 5% (1σ). The study reveals that TXRF can be used as a fast analytical technique for the determination of uranium in seawater.  相似文献   

9.
A quick method for trace element determination of marine periphyton communities on soda float glass discs is presented. After addition of an internal standard, the community is measured by total-reflection X-ray fluorescence (TXRF) spectrometry. No sample preparation is required except a gentle wash with distilled water. The soda glass disc on which the periphyton community grows is used directly as the sample reflector in TXRF. The method was evaluated by the analysis of a certified reference material of plankton (CRM 414) and by comparison to a wet digestion method. Recovery rates for 13 and 130 μg-samples of CRM 414 are reasonable: between 0.6 and 1.4 for the elements K, Ca, Mn, Fe, Ni, Cu, Zn, As, Rb and Sr. Relative standard deviations for 130 μg-samples are 10% or less for most of these elements. In the comparison to wet digestion, natural periphyton samples were used and the two methods showed a good agreement.The different steps used in the quantification, such as accounting for the contribution from the glass to the TXRF spectrum, and the calculation of the sample mass from the spectrum, are described. It is shown that complicating factors, such as the required water wash and the influence of an inhomogeneous spatial distribution of the periphyton on the glass disc, do not adversely affect the quantification.  相似文献   

10.
XRF and TXRF were established as useful techniques for multi-element analysis of whole blood and human head hair samples. Direct-XRF with different collimation units and different X-ray excitation modes was successfully used for the determination of S, P, K, Ca, Fe, and Br elements in blood samples and K, Ca, Mn, Fe elements in human hair samples. Direct analysis by TXRF was used for the determination of Rb and Sr in digested blood and human hair samples, respectively, while, the co-precipitation method using APDC for TXRF analysis was used for the determination of Ni, Cu, Zn, and Pb elements in both matrices. As a result, the improved XRF and TXRF methods were applied for multi-element determination of elements in whole blood and human hair samples in non-occupational exposed population living in Damascus city. The mean concentrations of analyzed elements in both matrices were on the reported range values for non-occupational population in other countries.  相似文献   

11.
PM 10 and PM 2.5 (PMx) have been recently introduced as new air quality standards in the EU (Council Directive 1999/30/EC) for particulate matter. Different estimates and measurements showed that the limit values for PM 10 will be exceeded at different locations in Europe, and thus measures will have to be taken to reduce PMx mass concentrations. Source apportionment has to be carried out, demanding comparable methods for ambient air and emission sampling and chemical analysis. Therefore, a special ambient-air sampler and a specially designed emission sampler have been developed. Total-reflection X-ray fluorescence analysis (TXRF) was used for multi-element analyses as a fast method with low detection limits. For ambient air measurements, a sampling unit was built, impacting particle size classes 10–2.5 μm and 2.5–1.0 μm directly onto TXRF sample carriers. An electrostatic precipitator (ESP) was used as back-up filter to also collect particles <1 μm directly onto the TXRF sample carriers. Air quality is affected by natural and anthropogenic sources, and the emissions of particles <10 μm and <2.5 μm, respectively, have to be determined to quantify their contributions to the so-called coarse (10–2.5 μm) and fine (<2.5 μm) particle modes in ambient air. For this, an in-stack particle sampling system was developed, according to the new ambient air quality standards and in view of subsequent analysis by TXRF. These newly developed samplers, in combination with TXRF analyses, were employed in field campaigns to prove the feasibility and capabilities of the approach. Ambient air data show the quantification of a wide spectrum of elements. From those concentrations, PMx ratios were calculated as an indicator for different sources of elements. Results useful for source apportionment are also the elemental day/night ratios calculated to determine local contributions to PMx mass concentrations. With regard to the emission measurements, results of mass and elemental concentrations obtained in two different processes (steel industry) show that the new PM 10/PM 2.5 cascade impactor and measurements with TXRF give characteristic fingerprints for different sources. Size-fractionated ambient air and emission sampling, together with multi-element analysis, prove to be a useful approach to derive information for source–receptor modeling, a method necessary to set up effective abatement strategies to reduce PMx mass concentrations.  相似文献   

12.
An intercomparison survey has been carried out in order to evaluate the performance of two related X-ray fluorescence techniques as compared to the achievements of several other analytical techniques applied for trace elements determination in drinking water. A relatively new technique, total reflection X-ray fluorescence (TXRF) and a novel related technique, grazing emission X-ray fluorescence (GEXRF) have been used for the analysis of a mineral water sample. The concentrations of the following elements have been determined: Na, Mg, K, Ca, Ni, Cu, Zn and Sr. The mineral water sample has also been analyzed by a number of other analytical techniques, routinely utilized in drinking water quality control. The analyses were performed in eleven laboratories which reported 286 individual determinations producing 75 laboratory means. From the obtained results, it can be concluded that the TXRF technique is suitable for a direct determination of heavy elements in drinking water (above potassium, Z = 19). This technique can compete with other analytical techniques routinely used in water quality monitoring. First results obtained with GEXRF spectrometry show that this technique can be successfully applied for the determination of low-Z elements in drinking water. However, results for sodium and magnesium were systematically too low, indicating that modifications of the quantification procedure may be required to improve the accuracy of determination for these light elements. Received: 5 January 1998 / Revised: 17 February 1998 / Accepted: 18 February 1998  相似文献   

13.
Selenium is essential for many aspects of human health and, thus, the object of intensive medical research. This demands the use of analytical techniques capable of analysing selenium at low concentrations with high accuracy in widespread matrices and sometimes smallest sample amounts.In connection with the increasing importance of selenium, there is a need for rapid and simple on-site (or near-to-site) selenium analysis in food basics like wheat at processing and production sites, as well as for the analysis of this element in dietary supplements. Common analytical techniques like electrothermal atomic absorption spectroscopy (ETAAS) and inductively-coupled plasma mass spectrometry (ICP-MS) are capable of analysing selenium in medical samples with detection limits in the range from 0.02 to 0.7 μg/l. Since in many cases less complicated and expensive analytical techniques are required, TXRF has been tested regarding its suitability for selenium analysis in different medical, food basics and dietary supplement samples applying most simple sample preparation techniques.The reported results indicate that the accurate analysis of selenium in all sample types is possible. The detection limits of TXRF are in the range from 7 to 12 μg/l for medical samples and 0.1 to 0.2 mg/kg for food basics and dietary supplements. Although this sensitivity is low compared to established techniques, it is sufficient for the physiological concentrations of selenium in the investigated samples.  相似文献   

14.
Sapphire is presented as a new sample carrier material for total-reflection X-ray fluorescence spectrometry (TXRF). A comparison with conventional sample carrier materials such as quartz glass, Perspex®, glassy carbon and boron nitride demonstrates that sapphire has all the physical and chemical properties required for TXRF micro and trace analysis. Moreover, sapphire sample carriers allow the determination of silicon in many matrices in a comparatively simple way. Especially for airborne particulate matter, acid digestion can be avoided by cool-plasma ashing of suitable filter materials directly on the sample carrier. This technique has been successfully applied to environmental samples.  相似文献   

15.
A one-step sample preparation by electro-deposition for total-reflection X-ray fluorescence (TXRF) analysis has been developed using a common three-electrode arrangement with a rotating disc as the working electrode. Several elements such as Cr, Mn, Fe, Co, Ni, Cu, Zn, Ag, Cd, Pb, As and U have been determined simultaneously in saline matrix. A special electrode tip has been constructed as a holder for the TXRF sample carrier, which consists of polished glassy carbon. The influence of parameters such as time, pH value, and trace element concentration on the deposition yield has been examined for 14 elements. From repeatability studies, the uncertainty in deposition yields at the 95% confidence level has been found to be less than 20% for most of these elements. Typical detection limits range from 5 to 20 ng/l under the experimental conditions applied here. By an appropriate choice of the reference element and by calculation of yield factors, reliable quantification can be achieved directly by internal standardization. First results obtained for the standard reference material CRM 505 are presented.  相似文献   

16.
17.
An electrolytic separation and enrichment technique was developed for the determination of trace elements by total-reflection X-ray fluorescence spectroscopy (TXRF). The elements of interest are electrodeposited out of the sample solution onto a solid, polished disc of pure niobium which is used as sample carrier for the TXRF measurement. The electrochemical deposition leads to a high enrichment of the analytes and at the same time to a removal of the matrix. This results in substantially improved detection limits in the lower picogram per gram region. The deposited elements are directly measured by TXRF without any further sample preparation step. The homogeneous thin layer of the analytes is an ideal sample form for TXRF, because scattered radiation from the sample itself is minimized. The proposed sample preparation method is useful particularly for the analysis of heavy metals in liquid samples with for TXRF disturbing matrices, e.g. sea water.  相似文献   

18.
The recently developed dry method for the element determination of single freshwater microcrustacean specimens (Daphnia) using total reflection X-ray fluorescence (TXRF) spectrometry showed that inhomogeneities of the biological material on the glass carriers resulted in some cases in high background and hampered the detection of certain trace elements (e.g. Cr, Ni). The aim of this study was to test how inhomogeneities of the biological material can be reduced using cold plasma ashing (CPA) techniques. For that, single specimens of the microcrustacean Daphnia pulex prepared according to the dry method were measured by TXRF before and after CPA. To determine the efficiency of the removal of organic matrix, the background and signal-to-background relationship of 28 samples were analyzed. The results showed (1) a highly significant reduction of the background by CPA fluctuating between 26 and 46% (all elements) and (2) a significant increase of the signal-to-background relationship by the factor 1.5–2.5 (all elements) and a much better detection of Cr, Pb, As and Se. The element concentrations (with exception of Cr, Ni and Pb) after ashing were in the same range or slightly higher than that before ashing. No significant differences between the two treatments were observed for Mn, As, Pb, Se (November), Sr (November), Cr (March) and Pb (March). The element concentration of P, K, Ca, Cu, Zn, Cr (November), Fe and Rb were significantly higher after ashing. In general, they increased by 1.5–13.6% and were highest for Rb (March) and P (November). In contrast, the element concentration of Ni and Cr (only March) decreased significantly after ashing (Ni: 91.6–92.1%, Cr: 91.3%). We recommend the use of CPA for biological material in the microgram-range as a routine method for TXRF analysis, especially when trace elements in minute concentrations are of interest.  相似文献   

19.
The contents of Cl, Ca, K, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb in raw coal fly ash from five Bulgarian power plants were determined by total reflection X-ray fluorescence (TXRF), using gallium as the internal standard. The samples were analysed as in slurry form in Triton? X-114. The experimental parameters, such as grain size, concentrations of fly ash slurry and excitation time were optimised. For validation of the method, the certified reference material BCR-176R fly ash was used. The precision of the results obtained is characterised by a relative standard deviation of approximately 10%. The resulting data confirm the suitability of TXRF for the simultaneous determination of major, minor and trace elements in coal fly ash samples. Further advantages provided by TXRF are easy sample preparation (no sample dissolution) and the small sample amount required for analysis.  相似文献   

20.
Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ion-implanted semiconductors), in environmental samples (waters, soils, biological and medical materials) and geological samples. Whereas such techniques as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), glow discharge mass spectrometry (GDMS), secondary ion mass spectrometry (SIMS) and inductively coupled plasma mass spectrometry (ICP-MS) have multielemental capability, other methods such as thermal ionization mass spectrometry (TIMS), accelerator mass spectrometry (AMS) and resonance ionization mass spectrometry (RIMS) have been used for sensitive mono- or oligoelemental ultratrace analysis (and precise determination of isotopic ratios) in solid samples. The limits of detection for chemical elements using these mass spectrometric techniques are in the low ng g−1 concentration range. The quantification of the analytical results of mass spectrometric methods is sometimes difficult due to a lack of matrix-fitted multielement standard reference materials (SRMs) for many solid samples. Therefore, owing to the simple quantification procedure of the aqueous solution, inductively coupled plasma mass spectrometry (ICP-MS) is being increasingly used for the characterization of solid samples after sample dissolution. ICP-MS is often combined with special sample introduction equipment (e.g. flow injection, hydride generation, high performance liquid chromatography (HPLC) or electrothermal vaporization) or an off-line matrix separation and enrichment of trace impurities (especially for characterization of high-purity materials and environmental samples) is used in order to improve the detection limits of trace elements. Furthermore, the determination of chemical elements in the trace and ultratrace concentration range is often difficult and can be disturbed through mass interferences of analyte ions by molecular ions at the same nominal mass. By applying double-focusing sector field mass spectrometry at the required mass resolution—by the mass spectrometric separation of molecular ions from the analyte ions—it is often possible to overcome these interference problems. Commercial instrumental equipment, the capability (detection limits, accuracy, precision) and the analytical application fields of mass spectrometric methods for the determination of trace and ultratrace elements and for surface analysis are discussed.  相似文献   