首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Substance P is a neuropeptide that belongs to the tachykinin neuropeptide family. It is an 11-amino acid polypeptide with the amino acid sequence: Arg-Pro-Lys-Pro-Gln-Gln-Phe-Phe-Gly-Leu-Met. It is synthesized as a larger protein and then enzymatically converted into the active undecapeptide. Substance P is widely distributed in the central and peripheral nervous systems. In the central nervous system, substance P participates in various behavioral responses and in regulating neuronal survival and degeneration. In the spinal cord, substance P participates in neurotransmission of pain and modulates autonomic reflexes. A rapid and selective method was developed for the determination of substance P concentration in rat spinal cord. The method consisted of a tissue homogenization, dilution, centrifugation and analysis by full-scan liquid chromatography electrospray quadrupole ion trap mass spectrometry (LC-ESI-QIT). The separation was achieved using a 50 x 2.1 mm C(18) analytical column combined with a gradient mobile phase composed of methanol: 0.1% formic acid in water set at a flow rate of 0.2 mL/min. An analytical range of 10-500 pmol/g was tested to analyze rat spinal cord. The LOD observed was 10 fmol injected on column. The novel method met all requirements of specificity, sensitivity, linearity, precision, accuracy and stability. In conclusion, a rapid and sensitive LC-ESI/MS/MS method was developed to identify and quantify substance P in rat spinal cord.  相似文献   

2.
A reliable and sensitive ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method was developed for the determination of zanubrutinib in the plasma of beagle dogs. The column used was an Acquity BEH C18 column (2.1 mm × 50 mm, 1.7 μm), maintained at 40°C with an injection volume of 2 μl. The gradient elution program was as follows: 0–1 min, 10–10% A; 1–1.1 min, 10–90% A; 1.1–2.1 min, 90–90% A; 2.1–2.2 min, 90–10% A; 2.2–3.0 min, 10–10% A. Mobile phase A was 0.1% formic acid, B was acetonitrile, and the total analysis time was 3 min. The mass spectrometry was performed in positive ion mode, and the scanning mode was multi-reaction monitoring mode with electrospray ionization as the ion source; m/z 472.2 → 455.01 for zanubrutinib and m/z 441.03 → 137.99 for ibrutinib (internal standard). The plasma samples were processed by protein precipitation. The standard curve showed good linearity (r2 = 0.999 8) in the range of 1.0–1,000 ng/ml (zanubrutinib) with a low limit of quantification of 1 ng/ml. Also, the intra-day and inter-day precision (RSD) was <5.88% and the accuracy (RE) ranged from −1.56 to 1.08%; the recoveries of zanubrutinib in beagle plasma ranged from 90.12 to 93.53% (RSD 1.67–6.42%) and the ME values of zanubrutinib were 98.70–101.06% (RSD 5.37–8.49%, n = 6). All values meet US Food and Drug Administration requirements. A rapid, highly selective and sensitive method for the determination of zanubrutinib concentration in plasma by UPLC–MS/MS was successfully developed. This method is suitable for pharmacokinetic studies in beagle dogs by following oral administration of zanubrutinib.  相似文献   

3.
A UHPLC–MS/MS method for the quantification of ADP355, an adiponectin-derived active peptide, was developed and validated. The extraction method employed simple protein precipitation using methanol and chromatographic separation was achieved on anAccucore™ RP-MS C18 column (100 × 2.1 mm, 2.6 μm, 80 Å), using 0.1% formic acid in both water and acetonitrile with gradient elution at the flow rate of 400 μl/min within 4.0 min. Detections were performed under positive ion mode with multiple reaction monitoring ion transitions m/z 1109.2 → 309.8 and 871.4 → 310.1 for ADP355 and Jt003 respectively at unit resolution. The linearity range of the calibration curve was 2–1,000 ng/ml with a lower limit detection of 0.5 ng/ml. The selectivity, linearity, precision, accuracy, recovery, matrix effect and stability were validated, and all items met the requirement of US Food and Drug Administration guidance. This method was successfully applied to an intravenous pharmacokinetic study of ADP355 in rats and the in-vitro stability in rat serum, plasma and whole blood was also assessed.  相似文献   

4.
A liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the quantification of tunicamycin in rat plasma as per regulatory guideline. Chromatography of tunicamycin and the IS in the processed plasma samples was achieved on an X‐Terra phenyl column using a binary gradient (mobile phase A, acetonitrile and mobile phase B, 5 mm ammonium formate) elution at a flow rate of 0.6 ml/min. LC–MS/MS was operated under the multiple reaction monitoring mode using the electrospray ionization technique in positive ion mode and the transitions of m/z 817.18 → 596.10, 831.43 → 610.10, 845.29 → 624.10, 859.23 → 638.10 and 309.24 → 163.20 were used to quantitate homologs A–D and the IS, respectively. The total chromatographic run time was 4.5 min. The correlation coefficient (r2) was >0.99 for all homologs with accuracy 90.7–107.4% and precision 0.74–15.1%. The recovery of homologs was 78.6–90.2%. No carryover was observed and the matrix effect was minimal. Tunicamycin four homologs were found to be stable on the bench‐top for 6 h, for up to three freeze–thaw cycles, in the injector for 24 h and for 1 month at ?80 ° C. The applicability of the validated method has been demonstrated in a rat pharmacokinetic study.  相似文献   

5.
A highly sensitive and rapid ultraperformance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed and validated for simultaneous quantification of the four main bioactive compounds, i.e. baicalin, baicalein, wogonoside and wogonin, in rat plasma after oral administration of Radix Scutellariae extract. Clarithromycin was used as an internal standard (IS). Plasma samples were processed by protein precipitation with methanol. The separation was performed on an Acquity BEH C18 column (100 × 2.1 mm, 1.7 μm) at a flow rate of 0.4 mL/min, using 0.1% formic acid–acetonitrile as mobile phase. The MS/MS ion transit ions monitored were 447.5 → 270.1 for baicalin, 270.1 → 168.1 for baicalein, 461.2 → 284.0 for wogonoside, 284.2 → 168.1 for wogonin and 748.5 → 158.1 for IS. Method validation was performed according to US Food and Drug Administration guidelines and the results met the acceptance criteria. The lower limit of quantification (LLOQ) achieved was 1.13 ng/mL for baicalin, 1.23 ng/mL for baicalein, 0.82 ng/mL for wogonoside and 0.36 ng/mL for wogonin. The calibration curves obtained were linear (r > 0.99) over the concentration range ~ 1–1000 ng/mL. The intra‐ and inter‐day precision was <15% and the accuracy was within ±14.7%. After validation, this method was successfully applied to a pharmacokinetic study of Radix Scutellariae extract.  相似文献   

6.
A bioanalytical method for the quantification of rosiglitazone in rat plasma and tissues (adipose tissue, heart, brain, bone, and kidney) using LC–MS/MS was developed and validated. Chromatographic separation was achieved on a Gemini C18 column (50 × 4.6 mm, 3 μm) using a mobile phase consisting of 10 mM ammonium formate (pH 4.0) and acetonitrile (10:90, v/v) at a flow rate of 0.8 mL/min and injection volume of 10 μL (internal standard: pioglitazone). LC–MS detection was performed with multiple reaction monitoring mode using target ions at m/z → 358.0 and m/z → 357.67 for rosiglitazone and pioglitazone (internal standard), respectively. The calibration curve showed a good correlation coefficient (r2) over the concentration range of 1–10,000 ng/mL. The mean percentage recoveries of rosiglitazone were found to be over the range of 92.54–96.64%, with detection and lower quantification limit of 0.6 and 1.0 ng/mL, respectively. The developed method was validated per U.S. Food and Drug Administration guidelines and successfully utilized to measure rosiglitazone in plasma and tissue samples. Further, the developed method can be utilized for validating specific organ-targeting delivery systems of rosiglitazone in addition to conventional dosage forms.  相似文献   

7.
A sensitive and rapid LC‐MS/MS method was developed and validated for the determination of kadsurenone in rat plasma using lysionotin as the internal standard (IS). The analytes were extracted from rat plasma with acetonitrile and separated on a SB‐C18 column (50 × 2.1 mm, i.d.; 1.8 µm) at 30 °C. Elution was achieved with a mobile phase consisting of methanol–water–formic acid (65:35:0.1, v/v/v) at a flow rate of 0.30 mL/min. Detection and quantification for analytes were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 357.1 → 178.1 for kadsurenone, and m/z 345.1 → 315.1 for IS. Calibration curves were linear over a concentration range of 4.88–1464 ng/mL with a lower limit of quantification of 4.88 ng/mL. The intra‐ and inter‐day accuracies and precisions were <8.9%. The LC‐MS/MS assay was successfully applied for oral pharmacokinetic evaluation of kadsurenone using the rat as an animal model. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A precise, high‐throughput and sensitive ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed for the determination of fluorochloridone (FLC) in rat plasma. The extraction of analytes from plasma samples was carried out by protein precipitation procedure using acetonitrile prior to UPLC‐MS/MS analysis. Verapamil was proved as a proper internal standard (IS) among many candidates. The chromatographic separation based on UPLC was well optimized. Multiple reaction monitoring in positive electrospray ionization was used with the optimized MS transitions at: m/z 312.0 → 292.0 for FLC and m/z 456.4 → 165.2 for IS. This method was well validated with good linear response (r2 > 0.998) observed over the investigated range of 3–3000 ng/mL and with satisfactory stability. This method was also characterized with adequate intra‐ and inter‐day precision and accuracy (within 12%) in the quality control samples, and with high selectivity and less matrix effect observed. Total running time was only 1.5 min. This method has been successfully applied to a pilot FLC pharmacokinetic study after oral administration. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
We developed and validated a semi‐automated LC/LC‐MS/MS assay for the quantification of imatinib in human whole blood and leukemia cells. After protein precipitation, samples were injected into the HPLC system and trapped onto the enrichment column (flow 5 mL/min); extracts were back‐flushed onto the analytical column. Ion transitions [M + H]+ of imatinib (m/z = 494.3 → 394.3) and its internal standard trazodone (372.5 → 176.3) were monitored. The range of reliable response was 0.03–75 ng/mL. The inter‐day precisions were: 8.4% (0.03 ng/mL), 7.2% (0.1 ng/mL), 6.5% (1 ng/mL), 8.2% (10 ng/mL) and 4.3% (75 ng/mL) with no interference from ion suppression. Autosampler stability was 24 hs and samples were stable over three freeze–thaw cycles. This semi‐automated method is simple with only one manual step, uses a commercially available internal standard, and has proven to be robust in larger studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
A sensitive LC–MS/MS method for the determination of bruceine D in rat plasma was developed. The analyte and IS were separated on a Luna C18 column (2.1 × 50 mm, 1.7 μm) using a mobile phase of acetonitrile and 0.1% formic acid in water (40:60, v/v) at a flow rate of 0.25 mL/min. The selected reaction monitoring mode was chosen to monitor the precursor‐to‐product ion transitions of m/z 409.2 → 373.2 for bruceine D and m/z 469.2 → 229.3 for IS using a negative ESI mode. The method was validated over a concentration range of 0.5–2000 ng/mL for bruceine D. Total chromatography time for each run was 3.5 min. The method was successfully applied to a pharmacokinetic study of bruceine D in rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
Zearalenone, a mycotoxin biosynthesized by various Fusarium fungi, is widely found as a contaminant in grains and animal feeds. This study describes a rapid and sensitive LC/MS/MS assay method for the quantification of zearalenone in rat serum. The assay was validated to demonstrate the specificity, linearity, recovery, lower limit of quantification (LLOQ), accuracy and precision. The multiple reaction monitoring was based on the transition of m/z 317.0 → 130.9 for zearalenone and 319.0 → 204.8 for zearalanone (internal standard). The assay utilized a single liquid–liquid extraction with t‐butyl methyl ether and isocratic elution, and the LLOQ was 0.5 ng/mL using 0.1 mL rat serum. The assay was linear over a concentration range from 0.5 to 200 ng/mL, with correlation coefficients >0.9996. The mean intra‐ and inter‐day assay accuracy was 101.2–112.9 and 96.3–108.0%, respectively. The mean intra‐ and inter‐day precision was between 1.3–7.6 and 3.6–10.6%, respectively. The developed assay was applied to a pharmacokinetic study after a bolus intravenous injection of zearalenone in rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
A highly sensitive, specific and enantioselective assay has been validated for the quantitation of OTX015 enantiomers [(+)‐OTX015 and (−)‐OTX015] in mice plasma on LC–MS/MS‐electrospray ionization as per regulatory guidelines. Protein precipitation was used to extract (±)‐OTX015 enantiomers and internal standard (IS) from mice plasma. The active [(−)‐OTX015] and inactive [(+)‐OTX015] enantiomers were resolved on a Chiralpak‐IA column using an isocratic mobile phase (0.2% ammonia/acetonitrile 20 : 80, v /v) at a flow rate of 1.2 mL/min. The total run time was 6.0 min. (+)‐OTX015, (−)‐OTX015 and IS eluted at 3.34, 4.08 and 4.77 min, respectively. The MS/MS ion transitions monitored were m/z 492 → 383 for OTX015 and m/z 457 → 401 for IS. The standard curves for OTX015 enantiomers were linear (r 2 > 0.998) in the concentration range 1.03–1030 ng/mL. The inter‐ and intraday precisions were in the range 2.20–13.3 and 8.03–12.1% and 3.80–14.4 and 8.97–13.6% for (+)‐OTX015 and (−)‐OTX015, respectively. Both the enantiomers were found to be stable in a battery of stability studies. This novel method has been applied to the study of stereoselective oral pharmacokinetics of (−)‐OTX015 and unequivocally demonstrated that (−)‐OTX015 does not undergo chiral inversion to its antipode in vivo in mice.  相似文献   

13.
A sensitive, selective and rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the quantification of gypenoside XLIX, a naturally occurring gypenoside of Gynostemma pentaphyllum in rat plasma and then validated according to the US Food and Drug Administration's Guidance for Industry: Bioanalytical Method Validation . Plasma samples were prepared by a simple solid‐phase extraction. Separation was performed on a Waters XBridgeTM BEH C18 chromatography column (4.6 × 50 mm, 2.5 μm) using a mobile phase of acetonitrile and water (62.5:37.5, v /v). Gypenoside XLIX and the internal standard gypenoside A were detected in the negative ion mode using selection reaction monitoring of the transitions at m/z 1045.6 → 913.5 and 897.5 → 765.4, respectively. The calibration curve was linear (R 2 > 0.990) over a concentration range of 10–7500 ng/mL with the lower quantification limit of 10 ng/mL. Intra‐ and inter‐day precision was within 8.6% and accuracy was ≤10.2%. Stability results proved that gypenoside XLIX and the IS remained stable throughout the analytical procedure. The validated LC–MS/MS method was then applied to analyze the pharmacokinetics of gypenoside XLIX after intravenous administration to rats (1.0, 2.0 and 4.0 mg/kg).  相似文献   

14.
A highly sensitive, rapid assay method has been developed and validated for the estimation of S‐citalopram (S‐CPM) in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves a simple liquid–liquid extraction of S‐CPM and phenacetin (internal standard, IS) from rat plasma with t‐butyl methyl ether. Chromatographic separation was operated with 0.2% formic acid:acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on a Symmetry Shield RP18 column with a total run time of 3.0 min. The MS/MS ion transitions monitored were 325.26 → 109.10 for S‐CPM and 180.10 → 110.10 for IS. Method validation and pre‐clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.5 ng/mL and the linearity was observed from 0.5 to 5000 ng/mL. The intra‐ and inter‐day precisions were in the range of 1.14–5.56 and 0.25–12.3%, respectively. This novel method has been applied to a pharmacokinetic study and to estimate brain‐to‐plasma ratio of S‐CPM in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
A sensitive and specific UPLC‐MS/MS method was developed and validated for the simultaneous determination of 2‐amino‐2‐(2‐(4′‐(2‐propyloxazol‐4‐yl)‐[1,1′‐biphenyl]‐4‐yl)ethyl)propane‐1,3‐diol (SYL930), phosphorylated metabolite (SYL930‐P) and hydroxylated metabolite (SYL930‐M) in dog blood using SYL927 and SYL927‐P, analogues of SYL930, as the internal standards. Analytes were extracted with protein precipitation followed by chromatographic separation on a ZorbaxSB‐C18 column (3.5 μm, 2.1 × 100 mm) with a gradient elution of methanol–water containing 0.1% formic acid (v /v). A triple quadrupole tandem mass spectrometer operating in the positive electrospray ionization mode was used to detect SYL930, SYL930‐P, SYL930‐M and IS transitions of 381.2 → 364.2, 461.2 → 334.2, 397.3 → 380.3, 367.1 → 350.4 and 447.5 → 320.2, respectively. The linear calibration curves for SYL930, SYL930‐P and SYL930‐M were 0.5–500, 0.2–100 and 0.5–100 ng/mL, respectively (r 2 > 0.99). The intra‐day and inter‐day precisions (RSD, %) of analytes did not exceed 9.16% except for low QCs (≤16.22%), and the accuracy (RE, %) ranged from −14 to 11.4%. The mean recoveries for SYL930, SYL930‐P and SYL930‐M in dog blood were 85.13–107.94, 73.84–80.08 and 85.64–95.44%, respectively. The validated method was successfully applied to pharmacokinetic and PK/PD studies of SYL930 and its two major metabolites in dogs after an oral administration of SYL930.  相似文献   

16.
A rapid and sensitive LC–MS/MS method was developed and validated for the simultaneous determination of nicotinamide and its metabolite N1-methylnicotinamide in human serum. Serum samples were prepared by protein precipitation with acetonitrile. The chromatographic separation was performed on a Waters Spherisorb S5 CN microbore column (2.0 × 100 mm, 5 μm) with gradient elution within 7 min. Acetonitrile and 5 mm ammonium formate aqueous solution (containing 0.1% formic acid) were used as mobile phases. Nicotinamide, N1-methylnicotinamide and N′-methylnicotinamide (internal standard) were detected with a triple-quadrupole tandem mass spectrometer in the positive ion mode. Multiple reaction monitoring was used to monitor precursor to product ion transitions of m/z 123.1 → 80.1 for nicotinamide, m/z 137.1 → 94.1 for N1-methylnicotinamide and m/z 137.1 → 80.1 for the internal standard. The linear ranges of nicotinamide and N1-methylnicotinamide were 5.000–160.0 and 2.500–80.00 ng/ml, respectively. The intra- and inter-day precisions (RSD) of both analytes were within 6.90%. The recoveries were >88%. The analytes were proven to be stable during all sample storage, preparation and analytic procedures. The method was successfully applied to determine the concentrations of nicotinamide and N1-methylnicotinamide in human serum to investigate the association between their concentrations and obesity in 1160 Chinese subjects.  相似文献   

17.
A selective and sensitive liquid chromatography tandem mass spectrometry method (LC‐MS/MS) was developed and validated for the determination of cefdinir in rat plasma and urine. Following a simple protein precipitation using methanol, chromatographic separation was achieved with a run time of 10 min using a Synergi 4 µ polar‐RP 80A column (150 × 2.0 mm, 4 µm) with a mobile phase consisting of 0.1% formic acid in water and methanol (65:35, v/v) at a flow rate of 0.2 mL/min. The protonated precursor and product ion transitions for cefdinir (m/z 396.1 → 227.2) and cefadroxil, an internal standard (m/z 364.2 → 208.0) were monitored in the multiple reaction monitoring in positive ion mode. The calibration curves for plasma and urine were linear over the concentration range 10–10,000 ng/mL. The lower limit of quantification was 10 ng/mL. All accuracy values were between 95.1 and 113.0% and the intra‐ and inter‐day precisions were <13.0% relative standard deviation. The stability under various conditions in rat plasma and urine was also found to be acceptable at three concentrations. The developed method was applied successfully to the pharmacokinetic study of cefdinir after oral and intravenous administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
A sensitive and specific high‐performance liquid chromatography–electrospray ionization–tandem mass spectrometry (HPLC‐ESI‐MS/MS) method was developed and validated for determination of rupestonic acid in rat plasma. Protein precipitation method was used to extract rupestonic acid and the internal standard (IS) warfarin sodium from rats plasma. The chromatographic separation was performed on an Agela Venusil XBP Phenyl column with an isocratic mobile phase consisting of methanol–0.1% formic acid in water (40:60, v/v), pumped at 0.4 mL/min. Rupestonic acid and the internal standard (IS) warfarin sodium were detected at m/z 247.2 → 203.1 and 307.1 → 161.3 in positive ion and multiple reaction monitoring mode respectively. The standard curves were linear over the concentration range of 2.5–5000 ng/mL (r2 > 0.99). The within‐day and between‐day precision values for rupestonic acid at four concentrations were 4.7–5.7 and 4.4–8.7%, respectively. The method described herein was fully validated and successfully applied to the pharmacokinetic study after an intravenous administration of rupestonic acid in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
A selective, sensitive and rapid LC–MS/MS method has been developed and validated as per US Food and Drug Administration regulatory guidelines for the simultaneous quantitation of colchicine and febuxostat in rat plasma. Colchicine and febuxostat were extracted from the rat plasma using 10% tert-butyl methyl ether in ethyl acetate using colchicine-d6 as an internal standard (IS). The chromatographic separation of colchicine, febuxostat and the IS was achieved using a mobile phase comprising 5 mm ammonium formate and 0.025% formic acid in acetonitrile (20:80, v/v) in isocratic mode on an Eclipse XDB-C18 column. The injection volume and flow rate were 5.0 μl and 0.9 ml/min, respectively. Colchicine and febuxostat were detected by positive electrospray ionization in multiple reaction monitoring mode using transition pairs (Q1 → Q3) of m/z 400.10 → 358.10 and 317.05 → 261.00, respectively. The assay was linear in the ranges of 0.25–254 and 2.60–622 ng/ml for colchicine and febuxostat, respectively. The inter- and intra-day precision values were 0.58–13.0 and 1.03–4.88% for colchicine and febuxostat, respectively. No matrix or carryover effects were observed during the validation. Both analytes were stable on the bench-top, in the autosampler and in storage (freeze–thaw cycles and long-term storage at −80 ° C). A pharmacokinetic study in rats was performed to show the applicability of the validated method.  相似文献   

20.
A sensitive and accurate LC–MS/MS method was established for quantifying bisabolangelone in rat plasma and tissues. Bisabolangelone was isolated and purified from Angelicae Pubescentis Radix. The pharmacokinetic and tissue distribution of bisabolangelone after administration to rat was performed by LC–MS/MS. Separation was carried out on a C8 (4.6 × 100 mm, 1.8 μm) column. The MS/MS transitions of bisabolangelone and tussilagone (internal standard) were set at m/z 249.1 → 109.1 and m/z 391.4 → 217.4, respectively. The lower limit of quantification in plasma and other tissues ranged from 1 to 4 ng/mL. The biosamples were prepared using protein precipitation method with acetonitrile. The recovery was >92%. The results showed that values of maximum concentrations and area under the curve depended linearly on the studied doses (2.5, 5 and 7.5 mg/kg body weight). The other ingredients in Angelicae Pubescentis Radix extract possibly reduce the absorption of bisabolangelone in rat. Tissue distribution revealed that bisabolangelone was widely distributed in vivo. The highest and lowest concentrations of bisabolangelone were found in the stomach and in the brain, respectively. It was concluded that the newly established HPLC–MS/MS method was suitable to describe the pharmacokinetic characteristics of bisabolangelone in rat after administration.  相似文献   