首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 70 毫秒
1.
The use of electrospray ionization (ESI) quadrupole ion trap mass spectrometry and reversed-phase high-performance liquid chromatography (HPLC) for the characterization of 2-aminobenzamide (2AB)-labeled oligosaccharides and N-linked protein oligosaccharide mixtures is described. The major signals were obtained under these conditions from the [M+Na]+ ions for all 2AB-derivatized oligosaccharides. Under collision-induced dissociation, sodiated molecular species generated in the ESI mode yield simple and predictable mass spectra. Tandem mass spectrometry (MS/MS) experiments with orders higher than two offer a number of ways to enhance MS/MS spectra and to derive information not present in MS and MS2 spectra. Information on composition, sequence, branching and, to some extent, interglycosidic linkages can be deduced from fragments resulting from the cleavage of glycosidic bonds and from weak cross-ring cleavage products. Reversed-phase HPLC and derivatization by reductive amination using 2-aminobenzamide were finally applied to characterize a glycan pool enzymatically released from glycoproteins.  相似文献   

2.
Electrospray ionization (ESI) and tandem mass spectrometry (MS/MS) experiments, as well as electronic impact (EI) and chemical ionization (CI) techniques, have been applied to the title compounds 1a-h. The observation of different fragmentation pathways in the three sets of spectra is in accord with different degrees of internal excitation of the investigated precursors. In ESI (methanol as solvent) and CI (methane as reagent gas) spectra, the MH(+) ion represents the most important peak, while the fragments [M - OH](+) and [M - SO](+) are either the base peak or a very abundant peak in the EI mass spectra of these compounds. ESI-MS/MS experiments on the parent ions [MH](+) show that the loss of a fragment of 140 Da corresponding to p-toluenesulfenic acid is common from all the precursors. As well as competitive pathways, the second generation ions have also been elucidated to allow some observations to be made concerning the relationships between structure type and mass spectrometric characteristics.  相似文献   

3.
We have previously described the site-specific glycosylation analysis of rat brain Thy-1 by LC/multistage tandem mass spectrometry (MS(n)) using proteinase-digested Thy-1. In the present study, detailed structures of oligosaccharides released from Thy-1 were elucidated by mass spectrometric oligosaccharide profiling using LC/MS with a graphitized carbon column (GCC-LC/MS). First, using model oligosaccharides, we improved the oligosaccharide profiling by ion trap mass spectrometry (IT-MS) coupled with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). Sequential scanning of a full MS(1) scan with FT-ICR-MS followed by data-dependent MS(n) with IT-MS in positive ion mode, and a subsequent full MS(1) scan with FT-ICR-MS followed by data-dependent MS(n) with IT-MS in negative ion mode enabled the monosaccharide composition analysis as well as profiling and sequencing of both neutral and acidic oligosaccharides in a single analysis. The improved oligosaccharide profiling was applied to elucidation of N-linked oligosaccharides from Thy-1 isolated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. It was demonstrated that Thy-1 possesses a significant variety of N-linked oligosaccharides, including Lewis a/x, Lewis b/y, and disialylated structure as a partial structure. Our method could be applicable to analysis of a small abundance of glycoproteins, and could become a powerful tool for glycoproteomics.  相似文献   

4.
Ion mobility spectrometry detection for gas chromatography   总被引:2,自引:0,他引:2  
The hyphenated analytical method in which ion mobility spectrometry (IMS) is coupled to gas chromatography (GC) provides a versatile alternative for the sensitive and selective detection of compounds after chromatographic separation. Providing compound selectivity by measuring unique gas phase mobilities of characteristic analyte ions, the separation and detection process of gas chromatography-ion mobility spectrometry (GC-IMS) can be divided into five individual steps: sample introduction, compound separation, ion generation, ion separation and ion detection. The significant advantage of a GC-IMS detection is that the resulting interface can be tuned to monitor drift times/ion mobilities (as a mass spectrometer (MS) can be tuned to monitor ion masses) of interest, thereby tailoring response characteristics to fit the need of a given separation problem. Because IMS separates ions based on mobilities rather than mass, selective detection among compounds of the same mass but different structures are possible. The most successful application of GC-IMS to date has been in the international space station. With the introduction of two-dimensional gas chromatography (2D-GC), and a second type of mobility detector, namely differential mobility spectrometry (DMS), GC prior to mobility measurements can now produce four-dimensional analytical information. Complex mixtures in difficult matrices can now be analyzed. This review article is intended to provide an overview of the GC-IMS/DMS technique, recent developments, significant applications, and future directions of the technique.  相似文献   

5.
Chen R  Wang L  Xiong C  Zhou Y  Zhen C  Zhang N  Tang Y  Zhou X  Wang J  Nie Z  Chen Y 《The Analyst》2011,136(18):3809-3814
Electrosonic spray ionization (ESSI) is a derivative technique of electrospray ionization (ESI) for mass spectrometry (MS) in which droplets are charged in the course of sonic spray. In this study, we applied ESSI MS to direct analysis of oligosaccharides and alpha hydroxy acids (AHAs) in fruits. The components were extracted from fruit fleshes by a feasible method prior to ESSI MS analysis, but the fruit juices were analyzed without further pretreatment. The results demonstrate that mainly alkali metal adducts of oligosaccharides are favorably produced in positive ion mode, while deprotonated AHAs and oligosaccharides are produced in negative ion mode. Compared with mass spectra obtained using electrospray droplet impact/secondary ion mass spectrometry (EDI/SIMS), mass spectra using ESSI make the identification of oligosaccharides more straightforward in positive ion mode than in negative ion mode.  相似文献   

6.
Differential mobility spectrometry or field asymmetric waveform ion mobility spectrometry (FAIMS) is gaining broad acceptance for analyses of gas-phase ions, especially in conjunction with largely orthogonal separation methods such as mass spectrometry (MS) and/or conventional (drift tube) ion mobility spectrometry. In FAIMS, ions are filtered while passing through a gap between two electrodes that may have planar or curved (in particular, cylindrical) geometry. Despite substantial inherent advantages of the planar configuration and its near-universal adoption in current stand-alone FAIMS devices, commercial FAIMS/MS systems have employed curved FAIMS geometries that can be more effectively interfaced to MS. Here we report a new planar (p-) FAIMS design with slit-shaped entrance and exit apertures that substantially increase ion transmission in and out of the analyzer. The entrance slit interface effectively couples p-FAIMS to multi-emitter electrospray ionization (ESI) sources, improving greatly the ion current introduced to the device and allowing liquid flow rates up to ∼50 μL/min. The exit slit interface increases the transmission of ribbon-shaped ion beams output by the p-FAIMS to downstream stages such as a MS. Overall, the ion signal in ESI/FAIMS/MS analyses increases by over an order of magnitude without affecting FAIMS resolution.  相似文献   

7.
Eighteen isoprenylated flavonoids (8 flavanones, 3 flavanols, and 7 chalcones) isolated from Kushen or synthesized were studied by positive and negative ion electrospray ionization multistage tandem mass spectrometry (ESI-MS(n)). Plausible fragmentation patterns were obtained by comparing their MS(n) spectra with each other, which were further supported by high-resolution MS data and two model compounds. It was shown that the 2'-OH group would make the C-ring of flavonoids studied more labile through a six-membered mechanism, resulting in base peaks of (1,3)A+ (positive mode) and (1,4)A(-) (negative mode). In addition, the 2'-OH is also responsible for the neutral loss of water in (+)ESI/MS(2) of flavanones. The neutral loss of water (or methanol) in (-)ESI/MS(2) of flavanols was elucidated by a E2 elimination mechanism. Different relative abundances (RA) of (1,3)A(+) and S(+) in (+)ESI/MS(2) spectra were used to discriminate flavanones with their open-ring products, chalcones, since the equilibrium for flavanone<-->chalcone isomerization in ESI ion source could not be obtained in positive mode.  相似文献   

8.
Chemical standards for positive ion mode electrospray ionization ion mobility spectrometry/mass spectrometry (ESI(+)-IMS/MS) are suggested. The low clustering tendency of tetraalkylammonium halides makes them ideal chemical standards for ESI(+)-IMS/MS. A homologous series of these compounds forms a useful external standard for instrument testing and resolution calibration of an IMS instrument. Selected homologues or a mixture of tetraalkylammonium halides can be used as mobility standards in the analytical runs. Absolute and relative reduced mobilities were calculated for C2--C8, C10 and C12 tetraalkylammonium halides. Absolute reduced mobilities in nitrogen were 1.88, 1.56, 1.33, 1.15, 1.02, 0.92, 0.84, 0.73, and 0.67 cm2 V(-1) s(-1), for C2--C8, C10 and C12 tetraalkylammonium halides, respectively. Relative reduced mobilities (relative to 2,6-di-tert-butylpyridine) for the same compounds were 1.20, 1.00, 0.855, 0.743, 0.658, 0.59, 0.54, 0.47, and 0.43, respectively.  相似文献   

9.
The separation of oligosaccharides derivatized with various esters of aminobenzoic acid by means of reversed-phase nano-HPLC (nHPLC) with on-line ESI mass spectrometry and off-line MALDI-TOF mass spectrometry as well as MEKC is described. For this purpose methyl, ethyl and butyl aminobenzoates and heptyloxyaniline were used as derivatization agents for homologous maltodextrins and oligosaccharides from human milk. Four different C(18) stationary phases were tested for this purpose because the type of stationary phase was shown to have a dramatic effect on the performance of the separation. Optimal results were obtained using n-butyl aminobenzoate as label and an encapsulated ODS stationary phase. The on-line coupling of nHPLC to ESI MS allowed to separate and identify various oligosaccharides from human milk. This technique enabled the exact attribution of the molecular structure to a signal in the chromatogram. In a second approach oligosaccharides were separated by nHPLC and subsequently fractionated. The fractions were analyzed by MALDI-TOF mass spectrometry. The results obtained by this approach confirmed the ESI MS data. An analogous separation profile was obtained by using sodium dodecyl sulfate in MEKC, which proves that the retention mechanisms of both techniques are identical.  相似文献   

10.
The effect of solvent and counter ion on the complexes of 2,5-bis(2-pyridyl)-1,3,4-oxadiazole (1) with Fe+2 and Fe+3 has been studied by electrospray ionization mass spectrometry (ESI/MS). As expected, upon ESI conditions the metal reduction proceeds, but it can be deduced that complexes with Fe+2 are favored over those with Fe+3. When methanol is used as solvent, the formation of complexes of stoichiometry 2:1 and 1:1 with counter ion attached (monovalent anion) is favored, for example, [1(2)+FeCl]+ ion. The use of methanol/water (1/1) as solvent favors the formation of complexes of stoichiometry 2:1 and 3:1, namely doubly charged [1(2)+Fe]+2 and [1(3)+Fe]+2 ions. The complexes containing anion of oxidative properties (ClO4-, NO3-), when the higher cone voltage is applied, yield unusual species [1n+FeOm]+ (n=1, 2; m=1, 2). The use of divalent counter ion (SO4(-2)) resulted in formation of complexes containing two iron cations, namely [1n+Fe2SO4]+2 (n=2, 3, 4) ions. These ions can be regarded as Fe-1 complexes bridged by a sulfate anion.  相似文献   

11.
The molecular structure of the wild strain of the lipopolysaccharide core of Aeromonas salmonicida, ssp salmonicida has been sequenced using tandem mass spectrometry. The core oligosaccharide was determined to contain an O-4 phosphorylated and O-5 substituted Kdo reducing group, and its structure is proposed as the follows: [structure: see text] After the core oligosaccharide of LPS was released from the lipid A portion by conventional treatment with 1% acetic acid, we demonstrated the existence of a homogeneous mixture composed mainly of the native core oligosaccharide containing the Kdo with its O-4 phosphate group intact, and a degraded core oligosaccharide mixture, which eliminated the O-4 phosphate group with extreme facility. The precise molecular structure and glycone sequence of the homogeneous mixture of phosphorylated and dephosphorylated core oligosaccharides was determined by electrospray ionization (ESI) mass spectrometry and tandem mass spectrometric analysis. CID-MS/MS of the homogeneous mixture of permethylated core oligosaccharides afforded a series of diagnostic product ions which confirmed the established sequence of the glycones to be determined. Matrix-assisted laser desorption/ionization (MALDI) tandem mass spectrometry reconfirmed the molecular structure of the dephosphorylated homogeneous permethylated mixture of the core oligosaccharides containing the diastereomeric 4,8- and 4,7-anhydro-alpha-keto acids.  相似文献   

12.
A sample preparation method that is suitable for sensitive detection of underivatized oligosaccharides by matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) has been investigated. As compared with the conventional dried‐droplet or ethanol (EtOH) recrystallization method, superior mass spectra in terms of ion yield and signal‐to‐noise (s/n) ratio were obtained when methanol (MeOH) was used as a solvent for the mixture of matrix and oligosaccharides. Based on these results, a new sample preparation method, named the ‘reverse thin layer method’, was developed. This method comprises two steps: first, complete drying of the oligosaccharide solution on the MALDI target plate; and second, deposition of the matrix dissolved in a small amount of MeOH. Using this method, a relatively homogeneous matrix crystal was generated and higher yields of both positive and negative ions were obtained from oligosaccharides compared with conventional methods. Notably, the method can be applied to various matrices including both solid and liquid matrices. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A new multifunctional oligosaccharide label with a 1 degree amino-group was synthesized and characterized. The oligosaccharide label was introduced into several neutral oligosaccharides by reductive amination, and the derivatives were analyzed by matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) and by electrospray ionization (ESI) mass spectrometry. It was demonstrated that the labeling reaction was satisfactory, and that as little as 50 pmol of starting material could be efficiently labeled with minimal loss to side reactions. A mixture of high-mannose N-glycans released from ribonuclease B was labeled. The label did not appear to interfere with structural characterization of the oligosaccharides by mass spectrometry. N-quaternization of the labeled oligosaccharides resulted in significantly increased sensitivity of detection with as little as 100 fmol on the probe detected. Deuterium coding of labeled oligosaccharide mixtures and relative abundance of mixture components was investigated. A protocol for the chromatographic separation of mixtures of labeled oligosaccharides by HPLC was developed and is reported here.  相似文献   

14.
Department of Chemistry, University of New Orleans, New Orleans, Louisiana, USA The effect of solvent composition on negative ion electrospray ionization (ESI) mass spectrometry was examined. The onset potentials for ES1 of a series of chlorinated solvents and methanol were found to be within the range predicted by D. P. H. Smith, based on differences in the surface tension of the solvents used. The tendency toward electric discharge decreased with increasing percent weight of chlorine in the solvent. This effect has been attributed to an increasing propensity for electron capture for more highly chlorinated solvents. Addition of the electron scavenger gas SF, was even more effective at suppressing corona discharge phenomena. In a comparison of ultimate signal intensity obtainable for a test analyte in 10% methanol, the highest signal, which was stable over the widest range of temperatures, was exhibited by chloroform compared to dichloromethane, 1,2-dichloroethane, carbon tetrachloride, and methanol (100%). Chloroform, thus, is a recommended solvent for negative ion electrospray mass spectrometry (ES/MS) when solubility is not a limiting issue. Solvent polarity was shown to exhibit a profound influence on the distribution of charge states in negative ion ES/MS. For both chlorinated and nonchlorinated organic solvents, the higher the solution dielectric constant, the more the charge-state distribution is shifted toward higher charge states. These observations build on the “electrophoretic” mechanism of droplet charging. Solvents with high solution dielectric constants are considered to be most effective at stabilizing multiply charged ions (where charge separation is greatest), and they are likely to increase the level of droplet charging. Solvents with high basicities (gas phase and solution phase) and high proton affinities, yet low dielectric constants, favor lower charge states in ES mass spectra of lipid A and cardiolipin from Escherichia coli. This indicates that gas-phase processes and solvent basicity contribute much less toward ion formation than solution-phase solvation via preferred orientation of the solvent dipole.  相似文献   

15.
采用电喷雾萃取电离质谱(EESI-MS)分析致癌性环境有机污染物多环芳烃(PAHs)生物标志物1-羟基芘(1-OHP),探究1-OHP在EESI源中电离的可行性,考察ESI溶剂和样品溶液组成对方法灵敏度的影响,初步建立I-OHP的EESI MS半定量分析方法.结果表明,溶液中1-OHP能够在EES1源中有效电离,生成准分子离子[M-H]- (m/z 217),并得到其二级质谱特征碎片离子[M- H- CO]- (m/z 189);水、甲醇、乙醇、正丙醇和正丁醇5种ESI溶剂中,使用甲醇时,离子峰m/z 217信噪比最大.样品溶液中甲醇含量越高,离子峰m/z 217强度越强.离子峰m/z 217强度与1-OHP浓度在10~200 μg/L内的线性相关性相对最好;相关系数(R)0.982;相对标准偏差(RSD)为3.4%~14.0%(n=5);定量下限约为10 μg/L(S/N=10);单次检测时间小于0.5 min.  相似文献   

16.
For the first time, we observed a stable and intense ion (m/z 376) of the oxygenated water cluster ion ((H(2)O)(20)O(+)) produced from simply spraying an aqueous solution of iron nanoparticles (Fe NPs) into an electrospray mass spectrometry (ESI-MS) system. Tandem mass spectrometric (MS/MS and MS/MS/MS) results were applied to identify the assignments of the fragment ions of m/z 376 in order to explore the possible structures of this cluster ion. The possible structures of the (H(2)O)(20)O(+) ions are proposed as pentagonal dodecahedron water clathrate cages from the results of tandem mass spectrometry since eliminations of five water molecules were frequently observed in the MS/MS results for many subsequent fragment ions of m/z 376. The formation of this oxygenated water cluster ion ((H(2)O)(20)O(+)) in ESI-MS is attributed to the high surface reactivity and surface energy of Fe NPs during ESI processes (under high temperature and high voltage (5 kV) of ESI spray environment). We believe that the observation of self-assembly formation of oxygenated water clusters is an important issue in nanoscience as well as in the fields of water clusters.  相似文献   

17.
Ion mobility-mass spectrometry   总被引:3,自引:0,他引:3  
This review article compares and contrasts various types of ion mobility-mass spectrometers available today and describes their advantages for application to a wide range of analytes. Ion mobility spectrometry (IMS), when coupled with mass spectrometry, offers value-added data not possible from mass spectra alone. Separation of isomers, isobars, and conformers; reduction of chemical noise; and measurement of ion size are possible with the addition of ion mobility cells to mass spectrometers. In addition, structurally similar ions and ions of the same charge state can be separated into families of ions which appear along a unique mass-mobility correlation line. This review describes the four methods of ion mobility separation currently used with mass spectrometry. They are (1) drift-time ion mobility spectrometry (DTIMS), (2) aspiration ion mobility spectrometry (AIMS), (3) differential-mobility spectrometry (DMS) which is also called field-asymmetric waveform ion mobility spectrometry (FAIMS) and (4) traveling-wave ion mobility spectrometry (TWIMS). DTIMS provides the highest IMS resolving power and is the only IMS method which can directly measure collision cross-sections. AIMS is a low resolution mobility separation method but can monitor ions in a continuous manner. DMS and FAIMS offer continuous-ion monitoring capability as well as orthogonal ion mobility separation in which high-separation selectivity can be achieved. TWIMS is a novel method of IMS with a low resolving power but has good sensitivity and is well intergrated into a commercial mass spectrometer. One hundred and sixty references on ion mobility-mass spectrometry (IMMS) are provided.  相似文献   

18.
The rapid separation of isomeric precursor ions of oligosaccharides prior to their analysis by mass spectrometry to the nth power (MS n ) was demonstrated using an ambient pressure ion mobility spectrometer (IMS) interfaced with a quadrupole ion trap. Separations were not limited to specific types of isomers; representative isomers differing solely in the stereochemistry of sugars, in their anomeric configurations, and in their overall branching patterns and linkage positions could be resolved in the millisecond time frame. Physical separation of precursor ions permitted independent mass spectra of individual oligosaccharide isomers to be acquired to at least MS3, the number of stages of dissociation limited only practically by the abundance of specific product ions. IMS–MS n analysis was particularly valuable in the evaluation of isomeric oligosaccharides that yielded identical sets of product ions in tandem mass spectrometry experiments, revealing pairs of isomers that would otherwise not be known to be present in a mixture if evaluated solely by MS dissociation methods alone. A practical example of IMS–MSn analysis of a set of isomers included within a single high-performance liquid chromatography fraction of oligosaccharides released from bovine submaxillary mucin is described.  相似文献   

19.
Negative ion nano-liquid chromatography/mass spectrometry (nano-LC/MS) and tandem mass spectrometry (nano-LC/MS(2)), using graphitised carbon as separating medium, were explored for analysing neutral and acidic O-linked and N-linked oligosaccharide alditols. Compared to the sensitivity of capillary LC/MS (flow rate of 6 microL/min) coupled with a conventional electrospray ionisation source, the nano-LC/MS (flow rate of 0.6 microL/min) with a nanoflow ion source was shown to increase the sensitivity ten-fold with a detection limit in the low-femtomole range. The absolute signals for the [M-nH](n-) ions of the oligosaccharides were increased 100-fold, enabling accumulation of high-quality fragmentation data in MS(2) mode, in which detection of low abundant sequence ions is necessary for characterisation of highly sialylated N-linked oligosaccharides. Oligosaccharides with high numbers of sialic acid residues gave dominant fragments arising from the loss of sialic acid, and less abundant fragments from cleavage of other glycosidic bonds. Enzymatic off-line desialylation of oligosaccharides in the low-femtomole range prior to MS(2) analysis was shown to increase the quality of the spectra. Automated glycofragment mass fingerprinting using the GlycosidIQ software confirmed the oligosaccharide sequence for both neutral desialylated as well as sialylated structures. Furthermore, the use of graphitised carbon nano-LC/MS enabled the detection of four sialylated O-linked oligosaccharides on membrane proteins from ovarian tissue (5 microg of total amount of protein).  相似文献   

20.
Tandem mass spectrometry (MS/MS) of peptides plays a key role in the field of proteomics, and an understanding of the fragmentation mechanisms involved is vital for data interpretation. Not all the fragment ions observed by low-energy collision-induced dissociation of protonated peptides are readily explained by the generally accepted structures for a- and b-ions. The possibility of a macrocyclic structure for b-type ions has been recently proposed. In this study, we have undertaken investigations of linear protonated YAGFL-NH(2), N-acetylated-YAGFL-NH(2), and cyclo-(YAGFL) peptides and their fragments using a combination of ion mobility (IM) separation and mass spectrometry. The use of IM in this work both gives insight into relative structural forms of the ion species and crucial separation of isobaric species. Our study provides compelling evidence for the formation of a stable macrocyclic structure for the b(5) ion generated by fragmentation of protonated linear YAGFL-NH(2). Additionally we demonstrate that the a(4) ion fragment of protonated YAGFL-NH(2) has at least two structures; one of which is attributable to a macrocyclic structure on the basis of its subsequent fragmentation. More generally, this work emphasizes the value of combined IM-MS/MS in probing the detailed fragmentation mechanisms of peptide ions, and illustrates the use of combined ion mobility/collisional activation/mass spectrometry analysis in achieving an effective enhancement of the resolution of the mobility separator.  相似文献   