首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A modified electrode was fabricated by electrochemical formation of poly(vinylferrocene) on the multi-wall carbon nanotube-alizarin red S matrix covered glassy carbon electrode. A higher electrochemical activity was obtained to the electrocatalytic oxidation of dopamine. The electrode surface was characterized electrochemically and spectroscopically. Poly(vinylferrocene) (PVF) in electrode was used as an electron transfer mediator in the electrochemical oxidation of compounds due to its perfect reversible redox properties. Multi-wall carbon nanotubes (MWCNTs) / alizarin red S (ARS)–PVF electrode was used to the determination of dopamine in the presence of ascorbic acid in 0.1 M sulphate buffer solution at pH 7. The performance of the MWCNTs/ARS–PVF electrode was evaluated by DPV and amperometry.  相似文献   

2.
In this work, we investigate the electrochemical activity of dopamine (DA) and uric acid (UA) using both a bare and a modified carbon paste electrode as the working electrode, with a platinum wire as the counter electrode and a silver/silver chloride (Ag/AgCl) as the reference electrode. The modified carbon paste electrode consists of multi-walled carbon nanotubes (>95%) treated with α-cyclodextrine, resulting in an electrode that exhibits a significant catalytic effect toward the electro-chemical oxidation of DA in a 0.2-M Britton–Robinson buffer solution (pH 5.0). The peak current increases linearly with the DA concentration within the molar concentration ranges of 2.0 × 10−6 to 5.0 × 10−5 M and 5.0 × 10−5 to 1.9 × 10−4 M. The detection limit (signal to noise >3) for DA was found to be 1.34 × 10−7 M, respectively. In this work, voltammetric methods such as cyclic voltammetry, chronoamperometry, chronocuolometry, differential pulse and square wave voltammetry, and linear sweep and hydrodynamic voltammetry were used. Cyclic voltammetry was used to investigate the redox properties of the modified electrode at various scan rates. The diffusion coefficient (D, cm2 s−1 = 3.05 × 10−5) and the kinetic parameters such as the electron transfer coefficient (α = 0.51) and the rate constant (k, cm3 mol−1 s−1 = 1.8 × 103) for DA were determined using electrochemical approaches. By using differential pulse voltammetry for simultaneous measurements, we obtained two peaks for DA and UA in the same solution, with the peak separation approximately 136 mV. The average recovery was measured at 102.45% for DA injection.  相似文献   

3.
Atta NF  Galal A  Azab SM 《The Analyst》2011,136(22):4682-4691
A novel and effective electrochemical sensor for the determination of morphine (MO) in 0.04 mol L(-1) universal buffer solution (pH 7.4) is introduced using gold nanoparticles electrodeposited on a Nafion modified carbon paste electrode. The effect of various experimental parameters including pH, scan rate and accumulation time on the voltammetric response of MO was investigated. At the optimum conditions, the concentration of MO was determined using differential pulse voltammetry (DPV) in a linear range of 2.0 × 10(-7) to 2.6 × 10(-4) mol L(-1) with a correlation coefficient of 0.999, and a detection limit of 13.3 × 10(-10) mol L(-1), respectively. The effect of common interferences on the current response of morphine namely ascorbic acid (AA) and uric acid (UA) is studied. The modified electrode can be used for the determination of MO spiked into urine samples, and excellent recovery results were obtained.  相似文献   

4.
A multiwalled carbon nanotubes (MWNT) modified glassy carbon electrode (GCE) coated with poly(orthanilic acid) (PABS) film (PABS–MWNT/GCE) has been fabricated and used for simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA) by differential pulse voltammetry (DPV). Scanning electron microscopy, Fourier transform infrared spectra, and electrochemical techniques have been used to characterize the surface morphology of the PABS–MWNT composite film and the polymerization of ABS on electrode surface. In comparison with the bare GCE and the MWNT-modified GCE, the PABS–MWNT composite film-modified GCE, which combines the advantages of MWNT and the self-doped PABS, exhibits good selectivity and sensitivity for the simultaneous and selective determination of UA and DA in the presence of AA. Due to the different electrochemical responses of AA, DA, and UA, PABS–MWNT/GCE can resolve the overlapped oxidation peak of DA and UA into two well-defined voltammetric peaks with enhanced current responses using both cyclic voltammetry (CV) and DPV. The peak potential separations between DA and UA are 170 mV using CV and 160 mV using DPV, respectively, which are large enough for the selective and simultaneous determination of these species. In the presence of 0.5 mM AA, the DPV peak currents are linearly dependent on the concentration of UA and DA in the range of 6–55 and 9–48 μM with correlation coefficients of 0.997 and 0.993, respectively. The detection limits (S/N = 3) for detecting UA and DA are 0.44 and 0.21 μM, respectively. The PABS–MWNT/GCE shows good reproducibility and stability and has been used for the simultaneous determination of DA and UA in the presence of AA in samples with satisfactory results.  相似文献   

5.
A carbon–iron nanoparticle modified glassy carbon electrode (CIN-GCE) has been developed for the determination of calcium dobesilate (CD) in pharmaceutical formulations. The CINs were characterized by Transmission electron microscopy and X-ray diffraction. It was found that the CIN has strong electrocatalytic effect for CD and leads to a greatly improved anodic detection of CD including higher sensitivity and better reproducibility. A detection limit of 2.0 × 10−7 M (S/N = 3) was obtained. The proposed CIN-GCE was applied to detect CD in pharmaceutical formulations with satisfactory results. The proposed CIN electrochemical sensing platform holds great promise for simple, rapid and accurate detection of CD in pharmaceutical formulations.  相似文献   

6.
In this research, copper oxide nanoparticles modified carbon paste electrode was developed for the voltammetric determination of lidocaine. The square wave voltammogram of lidocaine solution showed a well-defined peak between +0.5 and +1.5 V. Instrumental and chemical parameters influencing voltammetric response were optimized by both one at a time and Box–Behnken model of response surface methodology. The results revealed that there was no significant difference between two methods of optimization. The linear range was 1–2500 μmol L~(-1)(Ip= 0.11 C_(LH)+ 17.38, R~2= 0.999). The LOD and LOQ based on three and ten times of the signal to noise(S/N) were 0.39 and 1.3 μmol L~(-1)(n = 10),respectively. The precision of the method was assessed for 10 replicate square wave voltammetry(SWV)determinations each of 0.05, 0.5 and 1 μmol L~(-1) of lidocaine showing relative standard deviations 4.1%,3.7% and 2.1%, respectively. The reliability of the proposed method was established by application of the method for the determination of lidocaine in two pharmaceutical preparations, namely injection and gel.  相似文献   

7.

Acetaminophen is a well-known drug commonly used to provide pain relief, but it can also lead to acute liver failure at high concentrations. Therefore, there is considerable interest in monitoring its concentrations. Sensitive and selective acetaminophen electrochemical sensors were designed by cycling a glassy carbon electrode (GCE) to high potentials in the presence of β-CD in a phosphate electrolyte, or by simply activating the GCE electrode in the phosphate solution. Using cyclic voltammetry, adsorption-like voltammograms were recorded. The acetaminophen oxidation product, N-acetyl benzoquinone imine, was protected from hydrolysis, and this was attributed to the adsorption of acetaminophen at the modified GCE. The rate constants for the oxidation of acetaminophen were estimated as 4.3 × 10–3 cm2 s–1 and 3.4 × 10–3 cm2 s–1 for the β-CD-modified and -activated electrodes, respectively. Using differential pulse voltammetry, the limit of detection was calculated as 9.7 × 10–8 M with a linear concentration range extending from 0.1 to 80 μM. Furthermore, good selectivity was achieved in the presence of caffeine, ascorbic acid and aspirin, enabling the determination of acetaminophen in a commercial tablet. Similar electrochemical data were obtained for both the β-CD-modified and activated GCE surfaces, suggesting that the enhanced detection of acetaminophen is connected mainly to the activation and oxidation of the GCE. Using SEM, EDX and FTIR, no evidence was obtained to indicate that the β-CD was electropolymerised at the GCE.

  相似文献   

8.
Jia D  Dai J  Yuan H  Lei L  Xiao D 《Talanta》2011,85(5):2344-2351
Gold nanoparticles-poly(luminol) (Plu-AuNPs) hybrid film and multi-walled carbon nanotubes with incorporated β-cyclodextrin modified glassy carbon electrode (β-CD-MWCNTs/Plu-AuNPs/GCE) was successfully prepared for simultaneous determination of dopamine (DA) and uric acid (UA). The surface of the modified electrode has been characterized by X-ray photo-electron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDS), field-emission scanning electron microscope (SEM) and transmission electron microscope (TEM). Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) have been used to investigate the β-CD-MWCNTs/Plu-AuNPs composite film. Gold nanoparticles anchored into poly(luminol) film exhibited catalytic activity for DA. MWCNTs with incorporated β-CD can greatly promote the direct electron transfer. In 0.10 M phosphate buffer solution (PBS, pH 7.0), the DPV response of the β-CD-MWCNTs/Plu-AuNPs/GCE sensor to DA is about 8-fold as compared with the Plu-AuNPs/GCE sensor, and the detection limit for DA is about one order of magnitude lower than the Plu-AuNPs/GCE sensor. The steady-state current response increases linearly with DA concentration from 1.0 × 10−6 to 5.6 × 10−5 M with a low detection limit (S/N = 3) of 1.9 × 10−7 M. Moreover, the interferences of ascorbic acid (AA) and uric acid (UA) are effectively diminished. The applicability of the prepared electrode has been demonstrated by measuring DA contents in dopamine hydrochloride injection.  相似文献   

9.
The present paper describes a sensitive electrochemical detection of amlodipine (AMLO) at the poly-l-methionine–gold nanoparticles/multi-walled carbon nanotube modified glassy carbon electrode (PLM–GNPs/MWCNTs/GCE) by differential pulse voltammetry (DPV) technique at physiological pH 7.12. Cyclic voltammetry results demonstrate that the proposed electrode shows excellent electrocatalytic activity toward oxidation of AMLO. Kinetic parameters of the electrochemical reaction are calculated, and analytical variables such as MWCNT volumes, drug accumulation time, electropolymerization cycles and pH values are also optimized. Under optimal conditions, the linear range covering from 5 nM to 2.5 μM along with detection limit of 1 nM is obtained. Moreover, this method is successfully used to detect AMLO in pharmaceutical samples and biological fluids of a dosage received by the volunteer.  相似文献   

10.
Research on Chemical Intermediates - The purpose of the current research was to construct an intermediate (2-(4-Ferrocenyl-[1,2,3]triazol-1-yl)-1-(naphthalen-2-yl) ethanone (2FTNE)) and a magnetic...  相似文献   

11.
Several problems for the direct electrochemical oxidation of reduced glutathione (GSH) challenge the usage of electroanalytical techniques for its determination. In this work, the electrochemical oxidation of GSH catalyzed by gold nanoparticles electrodeposited on Nafion modified carbon paste electrode in 0.04?mol?L?1 universal buffer solution (pH?7.4) is proved successful. The effect of various experimental parameters including pH, scan rate and stability on the voltammetric response of GSH was investigated. At the optimum conditions, the concentration of GSH was determined using differential pulse voltammetry (DPV) in two concentration ranges: 0.1?×?10?7 to 1.6?×?10?5?mol?L?1 and 2.0?×?10?5 to 2.0?×?10?4?mol?L?1 with correlation coefficients 0.9988, 0.9949 and the limit of detections (LOD) are 3.9?×?10?9?mol?L?1 and 8.2?×?10?8?mol?L?1, respectively, which confirmed the sensitivity of the electrode. The high sensitivity, wide linear range, good stability and reproducibility, and the minimal surface fouling make this modified electrode useful for the determination of spiked GSH in urine samples and in tablet with excellent recovery results obtained.  相似文献   

12.
Phosphotungstic acid (PWA) was used for accumulation of nickel ions at the carbon paste electrode for preparation of PWA-modified CPE (PWA/CPE). The PWA was evenly mixed with graphite powder and paraffin oil. Then, for preparation of Ni/PWA/CPE, Ni ions were included onto the PWA/CPE surface through immersion method at open circuit condition. The scanning electron microscopy (SEM), energy-dispersive spectroscopy and electrochemical methods were used to verify the prepared electrodes. The SEM images reveal that morphology of the CPE was influenced by PWA addition. Application of the Ni/PWA/CPE for methanol oxidation was explored by various electrochemical techniques. Electrochemical response of methanol oxidation at the surface of Ni/PWA/CPE was 2.5 times higher than that Ni/CPE. The obtained results indicated that the modified electrode exhibited high electrocatalytic activity toward methanol oxidation. Then, catalytic rate constant was found to be 8.25 × 104 cm3 mol ?1 s?1 using chronoamperometry method. Furthermore, the effects of several parameters, such as PWA loading, NiSO4 concentration, accumulation time and methanol concentration toward methanol oxidation at the surface of this modified electrode as well as stability, have been investigated.  相似文献   

13.
Functionalized multiwall carbon nanotubes (f-MWCNTs) with varying functionalization degrees were prepared by chemical methods. The effect of f-MWCNTs on the cure kinetics of bismaleimide–triazine (BT) resin was studied through nonisothermal differential scanning calorimetry (DSC) methods. The reaction activation energy (E α ) was determined by Flynn–Wall–Ozawa method. The results show that f-MWCNTs have more acceleration ability than pristine MWCNTs, due to more groups on the surface of f-MWCNTs than that of pristine MWCNTs. The activation energy was decreased from a value of 91.3 kJ mol?1 for the neat BT resin to 74.2 kJ mol?1 at the small mass loading (1.0 %) of f7-MWCNTs. The effect of f-MWCNTs on the reaction mechanism has been investigated. It shows that the f-MWCNTs accelerate the cure reaction of BT resin by providing the Lewis acids (H+) to make the “Diels–Alder” reaction and “ENE” reaction of BT resins more efficient. These findings offer useful insights into the cure technology of thermosetting resin filled with f-MWCNTs, without negative effect on the cure reaction.  相似文献   

14.
Zhou  Ying  Wang  Peilong  Su  Xiaoou  Zhao  Hong  He  Yujian 《Mikrochimica acta》2014,181(15):1973-1979

We are presenting an electrochemical immunosensor for the determination of the β-agonist and food additive ractopamine. A glassy carbon electrode (GCE) was modified with gold nanoparticles and a film of a composite made from poly(arginine) and multi-walled carbon nanotubes. Antibody against ractopamine was immobilized on the surface of the modified GCE which then was blocked with bovine serum albumin. The assembly of the immunosensor was followed by electrochemical impedance spectroscopy. Results demonstrated that the semicircle diameter increases, indicating that the film formed on the surface hinders electron transfer due to formation of the antibody-antigen complex on the modified electrode. Under optimal conditions, the peak current obtained by differential pulse voltammetry decreases linearly with increasing ractopamine concentrations in the 0.1 nmol•L−1 to 1 μmol•L−1 concentration range. The lower detection limit is 0.1 nmol•L−1. The sensor displays good stability and reproducibility. The method was applied to the analysis of spiked swine feed samples and gave satisfactory results.

Immunoassay for ractopamine based on glassy carbon electrode modified with gold nanoparticles and a film of a composite made from poly (arginine) and multi-walled carbon nanotubes was proposed. Under optimal conditions, the peak currents obtained by differential pulse voltammetry decreases linearly with increasing ractopamine concentrations in the 0.1 nmol•L−1 to 1 μmol•L−1 concentration range. The detection limit is 0.1 nmol•L−1.

  相似文献   

15.
We are presenting an electrochemical immunosensor for the determination of the β-agonist and food additive ractopamine. A glassy carbon electrode (GCE) was modified with gold nanoparticles and a film of a composite made from poly(arginine) and multi-walled carbon nanotubes. Antibody against ractopamine was immobilized on the surface of the modified GCE which then was blocked with bovine serum albumin. The assembly of the immunosensor was followed by electrochemical impedance spectroscopy. Results demonstrated that the semicircle diameter increases, indicating that the film formed on the surface hinders electron transfer due to formation of the antibody-antigen complex on the modified electrode. Under optimal conditions, the peak current obtained by differential pulse voltammetry decreases linearly with increasing ractopamine concentrations in the 0.1 nmol?L?1 to 1 μmol?L?1 concentration range. The lower detection limit is 0.1 nmol?L?1. The sensor displays good stability and reproducibility. The method was applied to the analysis of spiked swine feed samples and gave satisfactory results. Figure
Immunoassay for ractopamine based on glassy carbon electrode modified with gold nanoparticles and a film of a composite made from poly (arginine) and multi-walled carbon nanotubes was proposed. Under optimal conditions, the peak currents obtained by differential pulse voltammetry decreases linearly with increasing ractopamine concentrations in the 0.1 nmol?L?1 to 1 μmol?L?1 concentration range. The detection limit is 0.1 nmol?L?1.  相似文献   

16.
Journal of Solid State Electrochemistry - Pb2+ ions were detected on a carbon paste electrode modified with a geopolymer cement. The X-ray pattern and the infrared spectrum of the geopolymer...  相似文献   

17.
18.
A simple, sensitive, and reliable method based on a combination of multi-walled carbon nanotubes with incorporated β-cyclodextrin (β-CD-MWNTs) and a polyaniline (PANI) film-modified glassy-carbon (GC) electrode has been successfully developed for determination of dopamine (DA) in the presence of ascorbic acid (AA). The PANI film had good anti-interference properties and long-term stability, because of the permselective and protective properties of the conducting redox polymer film. The acid-treated MWNTs with carboxylic acid functional groups promoted the electron-transfer reaction of DA and inhibited the voltammetric response of AA. Sensitive detection of DA was further improved by the preconcentration effect of formation of a supramolecular complex between β-CD and DA. The analytical response of the β-CD-MWNTs/PANI film to the electrochemical behavior of DA was, therefore, better than that of a MWNTs/PANI film, a PANI film, or a bare glassy-carbon (GC) electrode. Under the conditions chosen a linear calibration plot was obtained in the range 1.0 × 10−7–1.0 × 10−3 mol L−1 and the detection limit was 1.2 × 10−8 mol L−1. Interference from AA was effectively eliminated and the sensitivity, selectivity, stability, and reproducibility of the electrodes was excellent for determination of DA.  相似文献   

19.
A sensitive and selective electrochemical method for the determination of norepinephrine using a poly (Evans Blue) film-modified glassy carbon electrode was developed. The polymer film-modified electrode shows excellent electrocatalytic activity toward the oxidation of norepinephrine (NE) in phosphate buffer solution (pH 5.0). The linear range of 5.0 × 10−7–1.8 × 10−5 M and detection limit of 3.5 × 10−8 M were observed for the determination of NE in pH 5.0 phosphate buffer solutions. The interference studies showed that the modified electrode had excellent selectivity for the determination of NE in the presence of large excess of ascorbic acid (AA) and uric acid (UA). The differences of the oxidation peak potentials for NE-AA and NE-UA were about 175 and 172 mV, respectively. The resolution is large enough to determine AA, NE and UA individually. This work provides a simple and easy approach to selective detection of NE in the presence of AA and UA in physiological samples. The article is published in the original.  相似文献   

20.
A novel DNA electrochemical biosensor for label-free determination of DNA sequence related to the Avian Influenza Virus (AIV) genotype was demonstrated in this paper. First, the multi-walled carbon nanotubes–cobalt phthalocyanine (MWNTs–CoPc) nanocomposite and poly (amidoamine) (PAMAM) dendrimer (generation 4.0) were modified on the glassy carbon electrode (GCE) sequentially. Then, DNA probes were successfully immobilized on the modified electrode with G4 PAMAM dendrimer acting as the coupling agent. The hybridization events were monitored by differential pulse voltammetry (DPV) measurement based on the oxidation signals of guanine without any external labels. Under the optimal conditions, the difference in guanine oxidation signal of the probe modified GCE in the absence and presence of complementary target (ΔIp) was linear with the logarithmic value of the complementary target concentration from 0.01 to 500 ng/ml with a correlation coefficient of 0.998 and a detection limit of 1.0 pg/ml.  相似文献   