首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A stability indicating, reversed-phase ion-pair high-performance liquid chromatographic method was developed and validated for the determination of risedronate in pharmaceutical dosage forms. The determination was performed on a BDS C18 analytical column (250 mm × 4.6 mm i.d., 5 μm particle size); the mobile phase consisted of 0.005 M tetrabutylammonium hydroxide and 0.005 M pyrophosphate sodium (pH 7.0) mixed with acetonitrile in a ratio (78:22, v/v) and pumped at a flow rate 1.00 mL min−1. The ultraviolet (UV) detector was operated at 262 nm. The retention times of magnesium ascorbyl phosphate, which was used as internal standard and risedronate were 4.94 and 5.95 min, respectively. The calibration graph was ranged from 2.50 to 20.00 μg mL−1, while detection and quantitation limits were found to be 0.48 and 1.61 μg mL−1, respectively. The intra- and inter-day percentage relative standard deviations, %R.S.D., were less than 5.9%, while the relative percentage error, %Er, was less than 0.4%. The method was applied to the quality control of commercial tablets and content uniformity test and proved to be suitable for rapid and reliable quality control.  相似文献   

2.
A simple, precise, and accurate isocratic reversed-phase (RP) stability-indicating column high-performance liquid chromatographic (HPLC) assay method was developed and validated for determination of nebivolol in solid pharmaceutical dosage forms. Isocratic RP-HPLC separation was achieved on a Phenomenex Luna C8 (2) column (250 mm x 4.6 mm id, 5 microm particle size) using mobile phase composed of acetonitrile-pH 3.5 phosphate buffer (35 + 65, v/v) at a flow rate of 1.0 mL/min, and detection was performed at 280 nm using a photodiode array detector. The drug was subjected to oxidation, hydrolysis, photolysis, and heat to apply stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness, and solution stability. The method was linear in the drug concentration range of 40-160 microg/mL with a correlation coefficient of 0.9999. The repeatability relative standard deviation (RSD) for 6 samples was 0.69%, and the intermediate precision (RSD) for 6 samples was 1.39%. The accuracy (recovery) was between 98.57 and 99.55%. Degradation products produced as a result of stress studies did not interfere with detection of nebivolol, and the assay can thus be considered stability-indicating.  相似文献   

3.
Zafirlukast (ZAF) is a leukotriene receptor antagonist used in the treatment of chronic asthma. In this study, a simple and sensitive reversed-phase, high-performance liquid chromatographic method was developed for the determination of ZAF in pharmaceutical formulations and human plasma. Piribedil was used as an internal standard. Analysis was carried out on a Nucleosil C18 100 A (150 mm x 4.6 mm id, 5 Vm) column with acetonitrile-pH 3.0 acetate buffer (70 + 30, v/v) as the mobile phase at a flow rate of 0.8 mL/min. The peak was detected by an ultraviolet detector set at a wavelength of 240 nm. The retention times were about 3.9 min for piribedil and 5.8 min for ZAF. The developed method was applied to the determination of ZAF in its pharmaceutical formulation and spiked human plasma. For quantification of ZAF in spiked plasma, proteins were precipitated with ethanol before chromatographic analysis. The calibration range was linear from 49.69-437.50 ng/mL in spiked plasma. The absolute recovery from spiked plasma was 98.73 +/- 0.42% at a concentration of 254.78 ng/mL of ZAF. No endogenous substances from plasma were found to interfere.  相似文献   

4.
Atenolol (AT) and metoprolol (MT) are predominantly used in the treatment of angina pectoris, certain arrhythmias, systemic hypertension, and several other cardiovascular disorders. Both compounds are produced commercially in the racemic form, although the S-form is responsible for the desired biological effect. This paper describes a simple, rapid, precise, and accurate method for separating the enantiomers of AT and MT. AT isomers are separated by using a Chiralcel OD column (250 x 4.6 mm, 10 microm), hexane-ethanoldiethylamine-acetic acid (60 + 40 + 0.2 + 0.2, v/v/v/v) as the mobile phase, and a flow rate of 1.0 mL/min. MT isomers are separated by using a mobile phase with the same components in the following proportions (40 + 60 + 0.2 + 0.2, v/v/v/v) and a flow rate of 0.8 mL/min. Ultraviolet detection was at 276 nm for both analytes. The coefficients of variation (CVs) and average recoveries (ARs) for the R-enantiomers in samples A, B, C, D, and E were 1.15 and 101.06%, 0.74 and 99.25%, 1.05 and 102.57%, 0.84 and 101.57%, and 0.86 and 98.62%, respectively. The CVs and ARs for the S-enantiomers in samples A, B, C, D, and E were 1.33 and 98.87%, 0.99 and 100.76%, 1.17 and 101.69%, 1.26 and 100.39%, and 1.40 and 99.39%, respectively. The standard curves of R-AT, S-AT, R-MT, and S-MT showed good linearity over the concentration range studied with correlation coefficients of 0.9991, 0.998, 0.9988, and 0.999, respectively.  相似文献   

5.
A simple, robust, and rapid reversedphase high-performance liquid chromatographic method for the analysis of demeclocycline and its impurities is described. Chromatographic separations were achieved on a Symmetry Shield RP8 (75 mm × 4.6 mm, 3.5 μm) column kept at 40°C. The mobile phase was a gradient mixture of acetonitrile, 0.06 M sodium edetate (pH 7.5), 0.06 M tetrapropylammonium hydrogen sulphate (pH 7.5) and water, A (2:35:35:28 v/v/v/v) and B (30:35:35:0 v/v/v/v) pumped at a flow rate of 1 mL/min. UV detection was performed at 280 nm. The developed method was validated according to the ICH guidelines for specificity, limit of detection, limit of quantification, linearity, precision, and robustness. An experimental design was applied for robustness study. Results show that the peak shape, chromatographic resolution between the impurities, and the total analysis time are satisfactory and better than previous methods. The method has been applied for the analysis of commercial demeclocycline bulk samples available on the market.  相似文献   

6.
A non-aqueous reversed-phase high performance liquid chromatographic method (RP-HPLC) with UV detection at 313 nm was developed and validated for simultaneous determination of methylene bis-benzotriazolyl tetramethylphenol (Tinosorb M) along with three other chemical UV filters, octocrylene (Eusolex OCR), octyl methoxycinnamate (Eusolex 2292) and octyl salicylate (Eusolex OS) in suncare products. An isocratic elution was performed on a Hypersil BDS RP-C18 column (250 mm x 4.6 mm), 5 microm particle size, using a mobile phase consisted of methanol-acetonitrile (90:10, v/v) with a flow-rate of 1.5 ml/min. The determination of the four UV filters was not interfered by the excipients in the products. The method of external standard, as well as the standard addition method was used for the determination. The external standard calibration curves were linear for Eusolex OCR, Eusolex 2292, Eusolex OS, and Tinosorb M in the concentration ranges of 0.5-100 microM, 0.5-100 microM, 0.5-200 microM, and 0.2-100 microM, respectively. Day-to-day relative standard deviation of the determination was within 3%. Limits of detection and quantitation of the above compounds were found equal to 36 and 110 nM, 220 and 660 nM, 170 and 520 nM, 44 and 130 nM, respectively. The recovery of these four chemical UV filters from the spiked samples was 96-103%.  相似文献   

7.
8.
A simple, sensitive, and rapid liquid chromatographic method was developed and validated using diode array detection for the determination of five commonly used antimalarial drugs in pharmaceutical formulations and in human plasma. Chromatographic separation of antimalarial drugs and internal standard (ibuprofen) was achieved on a C18 column with a mobile phase composed of 10 mM dipotassium orthophosphate at pH 3.0, methanol, and acetonitrile in a ratio of 20:38:42 v/v, at a flow rate of 1 mL/min. The analytes were monitored at 220 nm and separated in ?10 min. The method was validated for linearity, accuracy, precision, limit of quantification, and robustness. Both intra‐ and interday precisions (in terms of %RSD) were lower than 3% and accuracy ranged from 98.1 to 104.5%. Extraction recoveries were ≥96% in plasma. The limits of quantitation for artemether, lumefantrine, pyrimethamine, sulfadoxine, and mefloquine were 0.3, 0.03, 0.06, 0.15, and 0.15 μg/mL in human plasma. Stability under various conditions was also investigated. The method was successfully applied for quantification of antimalarial drugs in marketed formulations and in spiked human plasma. The method can be employed for routine QC purposes and in pharmacokinetic investigations.  相似文献   

9.
A simple isocratic, RP-ultra-performance LC method was developed and validated for the determination of lacidipine, three process impurities formed during synthesis, and three degradation products present in drug substance and the drug product. An efficient chromatographic separation was achieved on an Acquity BEH C18 column using pH 4.5 ammonium acetate-acetic acid buffer-methanol (70 + 30, v/v) mobile phase. The monitoring wavelength was 240 nm, and the flow rate 0.25 mL/min. Forced degradation studies using acid, alkali, peroxide, water, heat, and light were conducted, and all impurities were separated. The method was validated successfully for specificity, precision, linearity, accuracy, LOD, LOQ, and robustness, according to International Conference on Harmonization guidelines. The linearity of the calibration curve for lacidipine and each impurity was found to be very good (r2 > 0.999). This method is shown to be suitable for analysis of lacidipine to evaluate the quality of drug substance and a drug product.  相似文献   

10.
A fast and accurate micellar electrokinetic capillary chromatography method was developed for quality control of pharmaceutical preparations containing cold remedies as acetaminophen, salicylamide, caffeine, phenylephrine, pseudoephedrine, norephedrine and chlorpheniramine. The method optimization was realized on a Beckman P/ACE System MDQ instrument. The baseline separation of seven analytes was performed in an uncoated fused silica capillary internal diameter (ID)=50 microm using tris-borate (20 mM, pH=8.5) containing sodium dodecyl sulphate 30 mM BGE. On line-UV detection at 214 nm was performed and the applied voltage was 10 kV. The operating temperature was 25 degrees C. After experimental conditions optimization, the proposed method was validated. The evaluated parameters were: precision of migration time and of corrected peak area ratio, linearity range, limit of detection, limit of quantification, accuracy (recovery), ruggedness and applicability. The method was then successfully applied for the analysis of three pharmaceutical preparations containing some of the analytes listed before.  相似文献   

11.
A selective, precise and new high-performance liquid chromatographic method for the analysis of loperamid hydrochloride in pharmaceutical formulations was developed and validated. The mobile phase consisting buffer (sodium-octansulphonate, triethylamine and ammonium hydroxide) in water: acetonitriie (45: 55, v/v) (pH 3.2). The absorbance was monitored with a DAD detector at 226 nm. The flow rate was 1.5 cm3 min−1. The linearity (r = 0.9947) and the recovery (98.58–100.42%) were found to be satisfactory. The detection and quantitation limits were found to be 0.95 and 3.12 μg cm−3. The results demonstrated that the procedure was accurate, precise and reproducible. It can be suitably applied for the estimation of lopera-mid hydrochloride in pharmaceutical formulations. The article is published in the original.  相似文献   

12.
A thin-layer chromatographic (TLC) method with densitometric quantitation using the absorption reflectance mode at 280 nm was developed and validated for the determination of chloramphenicol residues in controlling pharmaceutical equipment cleanliness. Simulated samples at residue levels 0.5, 1, and 1.2 mg/m2 were prepared by spreading the calculated amount of chloramphenicol solution on a 10 dm2 stainless steel surface. After evaporation of the solvent, the residue was removed by 2 methanol-wetted cotton swabs, which were then extracted with methanol. The extract was applied on a high-performance TLC (HPTLC) silica gel F254 plate together with standards ranging from 10 to 60 ng. Plates were developed in a horizontal developing chamber from both sides (36 applications per plate) by using n-hexane-ethyl acetate (35 + 65, v/v) as developing solvent. The mean recovery (n=6) at 1 mg/m2 was 95.8%, and the coefficient of variation was 5.8%. The absolute detection limit was 3 ng, and the quantitation limit 10 ng. The method detection limit was 0.3 mg/m2 by swabbing 2.5 dm2 and 0.075 mg/m2 by swabbing 10 dm2. Chloramphenicol was stable on the plate 2 h before and 24 h after development. Additionally, it was stable during 7 days storage on the cotton swabs in the solvent at room temperature and in diluted standard solution stored in darkness at 4 degrees C. The method can be applied to routine control of pharmaceutical equipment cleanliness by sampling from the stainless steel surface areas of 2.5 to 10 dm2, and an acceptable residue limit of 1 mg/m2.  相似文献   

13.
This research work aims to exploit the high selectivity and sensitivity of fluorescence detector to develop and validate a high performance liquid chromatography (HPLC) method having very small sampling volume, much better mass-sensitive detection limit and lower operating cost for the determination of Saquinavir (SQV), known to have low oral bioavailability, in rat plasma. Unlike the traditional methods that require at least 0.25 mL of plasma for each measurement, the present method requires only a 0.1 mL sample volume. This is very useful in reducing the blood collection from study rats, offering the possibility to make sufficient number of samples for pharmacokinetic study and minimizing the amount of blood-derived biological waste. After liquid-liquid extraction, the compounds were separated on a Vydac C18 monomeric column (250 mm × 4.6 mm i.d. × 5 μm particle size) using a mobile phase composed of acetonitrile and potassium dihydrogen phosphate buffer (45:55, v/v). Fluorescence detection was performed at 237 nm (excitation) and 380 nm (emission). Validity of the method was studied and the method was found to be precise and accurate with a linearity range from 0.005 to 1.000 μg mL−1 (r > 0.9980). The limit of detection (LOD) was found to be 0.001 μg mL−1. The intra-day and inter-day precision studies showed good reproducibility with coefficients of variation (C.V.) less than 11.4%. The developed method was applied successfully to monitor the pharmacokinetic profile following oral administration of SQV to rats.  相似文献   

14.
Clarithromycin is a very important macrolide antibiotic used to treat bacterial infections in human and veterinary medicine. This study reports the development and validation of cost-effective, simple, precise, accurate, and robust high-performance liquid chromatography (HPLC) for the determination of clarithromycin (CLA) in tablets. Reversed-phase chromatography was conducted using a standard column at 55°C with ultraviolet detection at 215 nm. A mobile phase consisting of acetonitrile –2-methyl-2-propanol –potassium phosphate buffer was used at a flow rate of 1.0 mL/min. The proposed method displayed good linearity, precision, accuracy, robustness, and specificity. The present HPLC was compared with capillary electrophoresis and bioassay methods and the results indicated that there was no significant difference between these methods. Moreover, the obtained results demonstrated the validity of the isocratic HPLC, which allows reliable quantitation of CLA in pharmaceutical samples. Thus, it can be used as a substitute alternative methodology for the routine quality control of this medicine, in situations where other methods are less accessible in the laboratory.  相似文献   

15.
A method is described for the determination of clomazone residues in surface water by high-performance liquid chromatography with UV detection. The method involves solid-phase extraction with C18 extraction tubes. Clomazone was separated on a C18 column with a mobile phase of methanol-water (65:35, v/v) at pH 4.0 and a flow-rate of 1.0 ml/min. After optimization of the extraction and separation conditions, the method was validated. The method developed can be used for determination of clomazone in surface water, at the limit of 0.1 mcirog/l set by the European Union drinking water directive, with a 400-fold preconcentration.  相似文献   

16.
17.
The present study reports the development and validation of a high-throughput high-performance liquid chromatographic (HPLC) assay for the determination of caffeine in food samples. The analyte was separated rapidly from sample matrix using a short monolithic column (50 mm × 4.6 mm i.d.). The flow rate was 3.0 mL min−1, while the mobile phase consisted of ACN/water (10:90, v/v). Caffeine was detected directly at 274 nm. Under the optimal HPLC conditions, the sampling rate was 60 h−1. The assay was validated for linearity, LOD and LOQ, precision, selectivity and ruggedness. The case of external calibration versus standard addition for the analysis of real samples was also examined. The proposed assay was applied to the analysis of beverages and coffee samples.  相似文献   

18.
An HPTLC method with densitometric quantification using fluorescence at 313 nm was developed and validated for the determination of ofloxacin residue in controlling pharmaceutical equipment cleanliness. Simulated samples at a residue level of 1 mg/m2 were prepared by spreading the calculated amount of ofloxacin solution on 1, 5, and 10 dm2 stainless steel surfaces. After evaporation of the solvent, the residue was removed by two ethanol wetted cotton swabs, which were thereafter extracted with the mixture of ethanol and Na2EDTA-water solution at pH 11 for 15 min with sonication. The extract and standards were applied on HPTLC silica gel 60 plates and then developed in a horizontal developing chamber from both sides using ethanol-conc. ammonia (4+1, v/v) as the mobile phase. The mean recovery (n=6) at 1 mg/m2 from 1, 5, and 10 dm2 was 95.3, 88.6, and 89.7% with the CV values 3.78, 4.41, and 4.97%, respectively. The absolute detection limit was 0.6 ng and the quantitation limit was 2 ng, but it was shown that these can be improved by immersion of the developed plate into a solution of liquid paraffin-n-hexane (1+2, v/v) to approximately 0.25 and 0.9 ng, respectively. The LOD of the method using detection without paraffin-n-hexane was 3, 0.6, and 0.3 microg/m2 by swabbing 1, 5, and 10 dm2, respectively. The method can be applied to routine control of pharmaceutical equipment cleanliness by sampling from stainless steel surface areas of 1 to 10 dm2 with acceptable residue limit/surface of 1 mg/m2.  相似文献   

19.
An isocratic reversed-phase high-performance liquid chromatographic method has been developed for separation and simultaneous determination of COX-2 inhibitors, viz., celecoxib, rofecoxib, valdecoxib, nimesulide and nabumetone, using 4-chloro-2-nitroaniline as internal standard. Good chromatographic separation was achieved using a reversed-phase Inertsil C(18) column with mobile phase consisting of methanol and 0.05% aqueous glacial acetic acid (68:32 v/v) using photodiode array (PDA) detector at 230 nm. It was validated with respect to accuracy, precision, linearity, limit of detection and quantification. The linearity range was found to be 1.0--20 microg/mL and the percentage recoveries were between 97.55 and 100.14. The method is suitable not only for the estimation of active ingredients in pharmaceutical dosage forms but also in vitro estimations in human plasma. It is simple, rapid, selective and capable of detecting and determining COX-2 inhibitors with a detection limit of 0.127--1.040 microg/mL simultaneously.  相似文献   

20.
Simultaneous determination of enalapril maleate (ENA) and nitrendipine (NIT) in pharmaceutical preparations was performed using liquid chromatography (LC) and the partial least-squares-1 (PLS-1) method. In LC, the separation was achieved on a C8 column and the optimum mobile phase for good separation in a gradient elution programme was found to be acetonitrile-water (φ r = 81: 19) and optimum flow-rate, temperature, injection volume, and detection wavelength were set at 1.0 mL min−1, 25°C, 10 μL, and 210 nm, respectively. Dienogest was selected as an internal standard. In the spectrophotometry, a PLS-1 chemometric method was used. The absorbance data matrix related to the concentration data matrix was established by measurement of absorbances in their zero order spectra with an increment of Δλ = 1 nm in the 220–290 nm range for ENA and with Δλ = 1 nm in the 230–290 nm range for NIT in the PLS-1 method. Following this step, calibration was established by using this data matrix to predict the unknown concentrations of ENA and NIT in their binary mixture. These optimised methods were validated and successfully applied to a pharmaceutical preparation in tablet form and the results were subjected to comparison.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号