首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
By using HPGe γ-ray spectrometry, the activity of the long-lived fission product 126Sn in a SnOB2 sample was measured. The number of 126Sn atoms and the ratio of 126Sn to Sn were calculated based on the half-life value of 2.35×105a and the chemical stoichiometry. The result of the ratio of 126Sn to Sn, (1.033±0.037)×10-8, is consistent with the results measured by the accelerator mass spectrometry (AMS) within uncertainty limits, which confirms our procedures in the measurement of 126Sn by AMS and lays a foundation for the AMS measurement of 126Sn at much lower levels.  相似文献   

2.
The accelerator mass spectrometry(AMS) is an effective method for the determination of the half-life of long-lived radionuclides. In this paper, we report a method for measurement of the half-life of79 Se. The number of79 Se atoms was determined from measured79Se/Se absolute ratios with the AMS system at the China Institute of Atomic Energy and the decay rate of79 Se was determined by counting the emitted β-rays with a liquid scintillation spectrometer. The major improvements of our measurements include using the high abundance of an79 Se sample which was cooled for many years to exclude the interference of short-lived nuclides, the extraction of SeO-2molecular ions, that results in a suppression of the79 Br background by as much as about five orders of magnitude. Also, an AMS measurement of the absolute ratio of79Se/Se was developed to avoid systematic errors. The results show that79Se/Se is(2.35±0.12)×10-7in the reference sample and the radioactivity of79 Se is(1.24±0.05) Bq/g, so the half-life of79 Se is(2.78±0.18)×105a.  相似文献   

3.
A laser phase determination method and a transfer function that includes a proportional term of a measured photoelectron energy spectrum are presented to directly measure the detailed temporal structure of a narrow bandwidth attosecond extreme-ultraviolet (EUV) pulse. The method is based on the spectrum measurement of an electron generated by EUV photo-ionization interacting with a femtosecond laser field. The results of the study suggest that measurements should be taken at 0° or 180° with respect to the linear laser polarization. The method has a temporal measurement range of about half a laser oscillation period. The temporal resolution also depends on the jitter and control precision of the laser and EUV pulses.  相似文献   

4.
A series of metamorphic high electron mobility transistors (MMHEMTs) with different Ⅴ/Ⅲ flux ratios are grown on CaAs (001) substrates by molecular beam epitaxy (MBE). The samples are analysed by using atomic force microscopy (AFM), Hall measurement, and low temperature photoluminescence (PL). The optimum Ⅴ/Ⅲ ratio in a range from 15 to 60 for the growth of MMHEMTs is found to be around 40. At this ratio, the root mean square (RMS) roughness of the material is only 2.02 nm; a room-temperature mobility and a sheet electron density are obtained to be 10610.0cm^2/(V.s) and 3.26×10^12cm^-2 respectively. These results are equivalent to those obtained for the same structure grown on InP substrate. There are two peaks in the PL spectrum of the structure, corresponding to two sub-energy levels of the In0.53Ga0.47As quantum well. It is found that the photoluminescence intensities of the two peaks vary with the Ⅴ/Ⅲ ratio, for which the reasons are discussed.  相似文献   

5.
乔闹生  蔡新华  姚春梅 《中国物理 B》2009,18(11):4881-4886
The dual-frequency grating measurement theory is proposed in order to carry out the measurement of a discontinuous object. Firstly, the reason why frequency spectra are produced by low frequency gratings and high frequency gratings in the field of frequency is analysed, and the relationship between the wrapped-phase and the unwrapping-phase is discussed. Secondly, a method to combine the advantages of the two kinds of gratings is proposed: one stripe is produced in the mutation part of the object measured by a suitable low frequency grating designed by MATLAB, then the phase produced by the low frequency grating need not be unfolded. The integer series of stripes is produced by a high frequency grating designed by MATLAB based on the frequency ratio of the two kinds of gratings and the high frequency wrapped-phase, and the high frequency unwrapping-phase is then obtained. In order to verify the correctness of the theoretical analysis, a steep discontinuous object of 600×600 pixels and 10.00~mm in height is simulated and a discontinuous object of ladder shape which is 32.00~mm in height is used in experiment. Both the simulation and the experiment can restore the discontinuous object height accurately by using the dual-frequency grating measurement theory.  相似文献   

6.
The New Muon (g-2) Collaboration at Fermilab has proposed to measure the anomalous magnetic moment of the muon, αμ, a factor of four better than was done in E821 at the Brookhaven AGS, which obtained αμ = [116592089(63)] × 10^-11 ±0.54 ppm. The last digit of a, is changed from the published value owing to a new value of the ratio of the muon-to-proton magnetic moment that has become available. At present there appears to be a difference between the Standard-Model value and the measured value, at the ≌ 3 standard deviation level when electron-positron annihilation data are used to determine the lowest-order hadronic piece of the Standard Model contribution. The improved experiment, along with further advances in the determination of the hadronic contribution, should clarify this difference. Because of its ability to constrain the interpretation of discoveries made at the LHC, the improved measurement will be of significant value, whatever discoveries may come from the LHC.  相似文献   

7.
The ~(10)Be/~7Be ratio is a sensitive tracer for the study of atmospheric transport, particularly with regard to stratosphere-troposphere exchange. Measurements with high accuracy and efficiency are crucial to ~7Be and ~(10)Be tracer studies. This article describes sample preparation procedures and analytical benchmarks for ~7Be and ~(10)Be measurements at the Xi'an Accelerator Mass Spectrometry(Xi'an-AMS) laboratory for the study of rainwater samples. We describe a sample preparation procedure to fabricate beryllium oxide(Be O) AMS targets that includes co-precipitation, anion exchange column separation and purification. We then provide details for the AMS measurement of ~7Be and ~(10)Be following the sequence BeO~-→Be~(2+)→Be~(4+) in the Xi'an- AMS. The ~(10)Be/~7Be ratio of rainwater collected in Xi'an is shown to be about 1.3 at the time of rainfall. The virtue of the method described here is that both ~7Be and ~(10)Be are measured in the same sample, and it is suitable for routine analysis of large numbers of rainwater samples by AMS.  相似文献   

8.
Through magnetization measurement with a SQUID magnetometer the heat treatment optimization of an international thermonuclear experimental reactor (ITER)-type internal-Sn Nb3Sn superconducting wire has been investigated. The irreversibility temperature T^* (H), which is mainly dependent on A15 phase composition, was obtained by a warming and cooling cycle at a fixed field. The hysteresis width △M(H) which reflects the flux pinning situation of the A15 phase is determined by the sweeping of magnetic field at a constant temperature. The results obtained from differently heat-treated samples show that the combination of T^* (H) with AM(H) measurement is very effective for optimizing the heat reaction process. The heat treatment condition of the ITER-type wire is optimized at 675℃/128 h, which results in a composition closer to stoichiometric Nb3Sn and a state with best flux pinning.  相似文献   

9.
We report a method for measuring diffusion coefficient D of liquids by using an aplanatic and asymmetric cylinder lens with a liquid core, which is designed as both a diffusion pool and the main imaging element. The precision is better than 10-4 RIU in measuring refractive index. The D values of ethylene glycol (EG) in water are measured for various EG concentrations at 25℃, and Dinf = 1.043 × 10^-5 cm^2/s under the condition of infinite dilution is obtained. The method is characterized by observing the diffusion process directly, faster measurement and obtaining the D value under the condition of infinite dilution.  相似文献   

10.
Based on a theoretical motion equation of encapsulated microbubbles within an ultrasound field, the subharmonic characterizations of microbubbles are optimally designed and analyzed by a computer aided design system. The effects of size, shell elasticity and acoustic pressure on subharmonic response of microbubbles are calculated theoretically to obtain the optimal parameters for nondestructive subharmonic imaging. In addition, microbubbles with different shell elasticity are prepared, and their subharmonic responses are measured in vitro. The results of theoretical calculation and acoustic measurement show that good subharmonic enhancement can be obtained by using the encapsulated microbubbles with the mean size of 3 μm, which were prepared from the surfactant solution with the proper ratio of shell material. It is also shown that the best operating acoustic pressure is 200 to 400 kPa for nondestructive subharmonic imaging based on such kind of microbubbles.  相似文献   

11.
The KLOE experiment at the φ-factory DAФPNE has measured the pion form factor in the range between 0.1 〈 Mππ^2 〈 0.85 GeV^2 using events taken at √s = 1 GeV with a photon emitted at large polar angles in the initial state. This measurement extends the Mππ^2 region covered by KLOE ISR measurements of the pion form factor down to the two pion production threshold. The value obtained in this measurement of the dipion contribution to the muon anomalous magnetic moment of △αμ^ππ= (478.5±2-0stat±4.8syst±2.9theo)·10^-10 further confirms the discrepancy between the Standard Model evaluation for αμ and the experimental value measured by the (g-2) collaboration at BNL.  相似文献   

12.
High quality and highly conductive n-type Al0.7Ga0.3N films are obtained by using AlN multi-step layers (MSL) with periodical variation of Ⅴ/Ⅲ ratios by low-pressure metalorganic chemical vapour deposition (LP-MOCVD). The full-width at half-maximum (FWHM) of (0002) and (1015) rocking curves of the Si-doped Al0.7Ga0.3N layer are 519 and 625 arcsec, respectively, Room temperature (RT) Hall measurement shows a free electron concentration of 2.9 × 10^19 cm^-3, and mobility of 17.8cm^2V^-1s^-1, corresponding to a resistivity of 0.0121 Ω cm. High conductivity of the Si-doped AlGaN film with such high Al mole fraction is mainly contributed by a remarkable reduction of threading dislocations (TDs) in AlGaN layer. The TD reducing mechanism in AlN MSL growth with periodical variation of Ⅴ/Ⅲ ratio is discussed in detail.  相似文献   

13.
Tetrahedral amorphous hydrogenated carbon (ta-C:H) films on Si(lO0) substrates were prepared by using a magnetic-field-filter plasma stream deposition system. Samples with different ratios of sp^3-bond to sp^2-bond were obtained by changing the bias voltage applied to the substrates. The ellipsometric spectra of various carbon films in the photon energy range of 1.9-5.4eV were measured. The refractive index n and the relative sp^3 C ratio of these films were obtained by simulating their ellipsometric spectra using the Forouhi-Bloomer model and by using the Bruggeman effective medium approximation, respectively. The haemocompatibility of these ta-C:H films was analysed by observation of platelet adhesion and measurement of kinetic clotting time. The results show that the sp^3 C fraction is dependent on the substrate bias voltage, and the haemocompatibility is dependent on the ratio of sp^3-bond to sp^2-bond. A good haemocompatibility material of ta-C:H films with a suitable sp^3 C fraction can be prepared by changing the substrate bias voltage.  相似文献   

14.
王敖金  胡坤生 《中国物理快报》2002,19(11):1727-1729
Membrane viscosity of the reconstituted vesicles was calibrated by rotational diffusion of bacteriorhodopin(BR) in dimyristoylphosphatidylcholine(DMPC) and egg phosphatidylcholine(PC) vesicles.Rotational diffusion of BR in the vesicles was measured by flash-induced absorption anisotropy decay.BR was,for the first time ,reconstituted successfully into DMPC and egg PC vesicles,From the measurement of flash-induced absorption anisotropy decay of BR,the value of rotational diffusion coefficient D was obtained from each curve fitting by a global fitting procedure and ,in turn,membrane viscosity η was estimated from D.The results have shown that membrane viscosity is temperature-dependent,It was decreased as temperature increased,but a transition occurred in the region of the respective phase transition of DMPC and egg PC,respectively,The decrease of η was fast near the phase transition for DMPC and egg PC.Few effects of lipid/BR ratio and glycerol or sucrose in suspension medium on membrane viscosity were found.  相似文献   

15.
Accelerator mass spectrometry (AMS) is one of the most promising methods to detect minute amounts of 182Hf. However, the sensitivity of 5×10^-11 for ^182Hf/180Hf obtained previously by the AMS method at China Institute of Atomic Energy (CIAE) cannot meet the requirement of some applications. We present some new improvements of measurement method for AMS measurement of 182Hf at the CIAE HI?13 tandem accelerator system. As a result, a sensitivity of 1.0×10^-11 for 182Hf/180Hf is achieved.  相似文献   

16.
A double sinusoidal phase modulating (SPM) laser diode interferometer for thickness measurements of a transparent plate is presented. A carrier signal is given to the interference signal by using a piezoelectric transducer, and the SPM interferometry is applied to measure the thickness of a transparent plate. By combining the double-modulation technique with the Bessel function ratio method, the measurement error originating from Sight intensity fluctuations caused by the modulation current can be decreased greatly. The thicknesses of a glass parallel plate and a quartz glass are measured in real time, and the corresponding experimental results are also given.  相似文献   

17.
The sensitivity of a transducer should be an important characteristic inthe field of NDT.But so far,no method for this measurement of the sensitivity of atransducer applied to the ultrasonic flaw detection is available.In this paper thetransducer is regarded as a plane source and the reciprocity parameter under thecondition of the far field is derived.We have calibrated the sensitivity of ultrasonictransducers with the reciprocity technique in the solid sample.The experimentsshow and confirm that the transmitting and receiving sensitivities of the transducerapplied to NDT can be exactly measured.The precision of the measurement is with-in ± 1dB under a certain coupling condition.  相似文献   

18.
Quantitative knowledge of the film thickness and mass fraction of the urea-water solution is very crucial in many practical applications. Film thickness or mass fraction can only be determined individually by conventional measurement techniques. We develop a novel measurement method to measure the film thickness and mass fraction of ure~water solution simultaneously. The absorption coefficients of urea-water solution (5 50 wt%) are measured, a pair of optimized wavelengths is then chosen to achieve high measurement sensitivity. Cross validation is also performed and uncertainties of the technique are smaller than 0.68% for thickness measurements and 1.86% for mass fractions.  相似文献   

19.
In quantum mechanics, the expectation value of an operator can be measured by using the projective measurement, ifthe coupling between the measured system and pointer is strong enough. However in the weak coupling regime, the pointercan not show all the eigenvalue of the physical quantity directly due to the overlapping among the pointer states, whichmakes the measurement of the expectation value difficult. In this paper, we propose an expectation value measurementmethod in the weak coupling regime inspired by the weak measurement scheme. Compared to the projective measurement,our scheme has two obvious advantages. Experimentally we use the internal state and motional state of a single trapped40Ca+ to establish the measurement scheme and realize the proof of principle demonstration of the scheme.  相似文献   

20.
The production of Ξ_(cc)~(++) baryons in proton-proton collisions at a centre-of-mass energy of s~(1/2)=13 TeV is measured in the transverse-momentum range 4 pT15 GeV/c and the rapidity range 2.0 y4.5.The data used in this measurement correspond to an integrated luminosity of 1.7 fb~(-1),recorded by the LHCb experiment during2016.The ratio of the Ξ_(cc)~(++) production cross-section times the branching fraction of the Ξ_(cc)~(++)→Λ_c~+K~-π~+π~+ decay relative to the prompt Λ_c~+production cross-section is found to be(2.22±0.27±0.29)×10~(-4),assuming the central value of the measured Ξ_(cc)~(++) lifetime,where the first uncertainty is statistical and the second systematic.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号