首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study reports a sensitive solvent extraction flow-injection (FI) method for the simultaneous spectrophotometric determination of free cyanide and thiocyanate in human saliva and pralidoxime solutions. Cyanide and thiocyanate form colored (λmax=540 nm) ternary complexes with copper and 2,2′-dipyridyl-2-quinolylhydrazone (DPQH) that are extractable into chloroform. The determination of thiocyanates in the presence of cyanides is accomplished after on-line masking of the latter with formaldehyde through a binary inlet static mixer (BISM). Total thiocyanates and cyanides are determined in a second run, without the use of the masking agent. The proposed method allows the determination of the analytes in the range of 0-4 mg l−1 thiocyanates and 0-3 mg l−1 cyanides, with the 3σ detection limits being 0.007 and 0.004 mg l−1, respectively. The precision of the method (sr<1.0% at 1 mg l−1 CN or SCN, n=12 in both cases) and the sampling rates were quite satisfactory (60 injections per hour). The method was applied to the analysis of human saliva and pralidoxime solutions and gave recoveries in the range of 98.0-102.2% for both analytes whereas the mean relative error was er=1.7%.  相似文献   

2.
Capillary zone electrophoresis (CZE) with indirect UV detection was used in developing a method for the simultaneous determination of inorganic anions, aliphatic and heterocyclic organic acids in various processed samples. The analytes were determined simultaneously in 10 min using an electrolyte containing 20 mM 2,3-pyrazine dicarboxylic acid, 65 mM tricine, 2 mM BaCl2, 0.5 mM cetyltrimethylammonium bromide, and 2 M urea at pH 8.06. Linear plots for the analytes were obtained in the concentration range of 2–150 mg L−1. Relative standard deviations (RSDs) of peak areas during a 3-day analysis period varied from 5.5% for glycolate to 9.5% for oxalate. RSDs of migration times varied between 0.4% and 1.1%. The detection limit (at S/N 3) was 1 mg L−1 for all the analytes studied. The proposed method was successfully demonstrated for the determination of carboxylic acids in eight oxygen treated samples of commercial softwood and hardwood kraft lignin and two red wine samples of Pinot Noir grapes. In the kraft lignin samples the concentrations of carboxylic acids correspond to the oxidation time. The acid concentrations of wine varied considerable.  相似文献   

3.
Del Campo G  Gallego B  Berregi I 《Talanta》2006,68(4):1126-1134
A study has been performed of the conditions for the reaction of histamine with o-phthaldehyde in a flow injection analysis system employing three channels, using an anion-exchange column to eliminate sample matrix interferences. Factorial design was used to determine which operational parameters should be included in the optimization and their optimal values were found. The method developed shows good selectivity for histamine determination in alcoholic beverages. A linear response of up to 2.0 mg l−1 was observed and the detection and quantification limits were 30 and 101 μg l−1, respectively. The repeatability, measured by the R.S.D. for 10 replicate injections, was 0.84 and 0.52% for histamine solutions of 0.20 and 2.0 mg l−1, respectively. The recoveries obtained in wine and cider samples were close to 100% and a sample frequency of 24 samples per hour was achieved.  相似文献   

4.
An artificial neural network (ANN) procedure was used in the development of a catalytic spectrophotometric method for the determination of Cu(II) and Ni(II) employing a stopped-flow injection system. The method is based on the catalytic action of these ions on the reduction of resazurin by sulfide. ANNs trained by back-propagation of errors allowed us to model the systems in a concentration range of 0.5-6 and 1-15 mg l−1 for Cu(II) and Ni(II), respectively, with a low relative error of prediction (REP) for each cation: REPCu(II) = 0.85% and REPNi(II) = 0.79%. The standard deviations of the repeatability (sr) and of the within-laboratory reproducibility (sw) were measured using standard solutions of Cu(II) and Ni(II) equal to 2.75 and 3.5 mg l−1, respectively: sr[Cu(II)] = 0.039 mg l−1, sr[Ni(II)] = 0.044 mg l−1, sw[Ni(II)] = 0.045 mg l−1 and sw[Ni(II)] = 0.050 mg l−1. The ANNs-kinetic method has been applied to the determination of Cu(II) and Ni(II) in electroplating solutions and provided satisfactory results as compared with flame atomic absorption spectrophotometry method. The effect of resazurin, NaOH and Na2S concentrations and the reaction temperature on the analytical sensitivity is discussed.  相似文献   

5.
The present paper describes a direct procedure for the determination of catechin and epicatechin concentrations in red wines employing reverse-phase high performance liquid chromatography (RP HPLC) and detection by fluorescence. The method was performed using a sample volume of 10 µL without dilution. The separation process employed a Chromolith performance RP-18e (100 mm × 4.6 mm) column, and the mobile phase was composed of solvent A: methanol-acetic acid-water (90:8:2) and solvent B: water-acetic acid-methanol (10:2:88) at a flow rate of 1.0 mL min− 1. Linearity was observed in the range of 1 to 30 mg L− 1, with limits of detection and quantification of 0.27 and 0.89 mg L− 1, respectively, for catechin and 0.33 and 1.01 mg L− 1, respectively, for epicatechin. The precisions estimated by the relative standard deviation were 3.34 and 1.09% for catechin concentrations of 0.5 and 20 mg L− 1 respectively and 2.82 and 0.49% for epicatechin concentrations of 0.5 and 20 mg L− 1, respectively. The evaluation of the accuracy was done using an addition/recovery assay. Four wine samples were used, and the recoveries varied from 105 to 108% for catechin and from 97 to 119% for epicatechin. The method was applied to the analysis of red wine samples collected from the São Francisco region, Bahia State, Brazil. Nine samples were analyzed, and the catechin and epicatechin concentrations varied from 7.51 to 73.20 and from 5.08 to 43.32 mg L− 1, respectively. The concentrations found agree with data reported in the literature.  相似文献   

6.
A multicommuted flow system is proposed for spectrophotometric determination of hydrosoluble vitamins (ascorbic acid, thiamine, riboflavine and pyridoxine) in pharmaceutical preparations. The flow manifold was designed with computer-controlled three-way solenoid valves for independent handling of sample and reagent solutions and a multi-channel spectrophotometer was employed for signal measurements. Periodic re-calibration as well as the standard addition method was implemented by using a single reference solution. Linear responses (r=0.999) were obtained for 0.500-10.0 mg l−1 ascorbic acid, 2.00-50.0 mg l−1 thiamine, 5.00-50.0 mg l−1 riboflavine and 0.500-8.00 mg l−1 pyridoxine. Detection limits were estimated as 0.08 mg l−1 (0.5 μmol l−1) ascorbic acid, 0.8 mg l−1 (2 μmol l−1) thiamine, 0.2 mg l−1 (0.5 μmol l−1) riboflavine and 0.1 mg l−1 (0.9 μmol l−1) pyridoxine at 99.7% confidence level. A mean sampling rate of 60 determinations per hour was achieved and coefficients of variation of 1% (n=20) were estimated for all species. The mean reagent consumption was 25-fold lower in relation to flow-based procedures with continuous reagent addition. Average recoveries between 95.6 and 100% were obtained for commercial pharmaceutical preparations. Results agreed with those obtained by reference methods at 95% confidence level. The flow system is suitable for application in quality control processes and in dissolution studies of vitamin tablets.  相似文献   

7.
This paper describes the use of a pervaporation (PV) technique in a flow injection (FI) system for selective improvement in iodide analysis. Iodide in the sample zone is oxidized to iodine, which permeates through a hydrophobic membrane. Detection of the diffused iodine is achieved using the chemiluminescent (CL) emission at 425 nm that results from the reaction between iodine and luminol. The method was applied for the analysis of some pharmaceutical products, such as nuclear emergency tablets and multivitamin tablets. Ascorbic acid present in multivitamin samples interfered seriously with the analysis, and off-line sample treatment using anion exchange resin was employed to successfully remove ascorbic acid before the analysis. Ascorbic acid was flushed from the column using 0.4 M sodium nitrate followed by elution of iodide with 2 M sodium nitrate. The detection limit (3S.D.) of the system was 0.5 mg l−1, with reproducibility of 5.2% R.S.D. at 5 mg l−1. Sample throughput was determined as 30 injections h−1. There was good agreement between iodide concentrations from extracted samples determined using four different methods, i.e., PV-FI, gas diffusion-flow injection, potentiometry and ICP-MS. A comparison of the analytical features of the developed pervaporation system with these of the previously reported chemiluminescence gas diffusion-flow injection previously reported is also described.  相似文献   

8.
A method of electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) for the determination of trace lanthanides and yttrium in soil samples with a polytetrafluorethylene (PTFE) emulsion as chemical modifier to promote the vaporization of the analytes from the graphite furnace was developed in this paper. The analytical characteristics, spectral interference and matrix effect of the analytical method were evaluated and critically compared with those of pneumatic nebulization inductively coupled plasma mass spectrometry (PN-ICP-MS). Under the optimized operation conditions, the relative detection limits of lanthanides (La-Lu) and yttrium for ETV-ICP-MS and PN-ICP-MS were 0.4-20 ng l−1 and 1.0-21 ng l−1, respectively, the absolute detection limits for ETV-ICP-MS were 4-200 fg, which were improved by 1-2 orders of magnitude compared with PN-ICP-MS. While the analytical precision of ETV-ICP-MS is worse than that of PN-ICP-MS, with the R.S.D.s (%) of 4.1-10% for the former and 2.9-7.8% for the latter. Regarding to the matrix effect, both conventional method and stepwise dilution method were employed to observe the effect of matrix and the very similar results were obtained. It was found that the highest tolerance concentration of the matrix is 1000 mg l−1 and 800 mg l−1 for ETV-ICP-MS and PN-ICP-MS, respectively. To assess the accuracy, the proposed method was applied to the determination of trace lanthanides and yttrium in three different soil standard reference materials and one soil sample, and the determined values are in good agreement with the certified values or reference values.  相似文献   

9.
Beyene NW  Van Staden JF 《Talanta》2004,63(3):599-604
A fully automated sequential injection spectrophotometric method for the determination of phenylephrine hydrochloride in pharmaceutical preparations is reported. The method is based on the condensation reaction of the analyte with 4-aminoantipyrine in the presence of potassium ferricyanide. The absorbance of the condensation product was monitored at 503 nm. A linear relationship between the relative peak height and concentration was obtained in the range 0.5-17.5 mg l−1. The detection limit (as 3σ value) was 0.09 mg l−1 and repeatability was 0.8 and 0.6% at 2.5 and 5 mg l−1, respectively. Results obtained by this method agreed very well with those obtained by the AOAC official method.  相似文献   

10.
Manju Gupta 《Talanta》2007,71(3):1039-1046
The aim of present work was to optimize the experimental parameters in single drop microextraction under solution immersion (SDME) and headspace (HS-SDME) extraction modes for the determination of periodate using guaifenesine [3-(2′-methoxyphenoxy)-1,2-propane diol] and norephedrine (phenylpropanolamine) as new and alternative reagents for the Malaprade reaction. The reactions were complete within 5 min resulting in the formation of 2-(2′-methoxyphenoxy)-acetaldehyde and benzaldehyde, respectively. SDME/HS-SDME of oxidation products with 2 μl of anisole or 1 μl of toluene, respectively, has permitted the determination of periodate at μg l−1 concentration levels. The results indicated that HS-SDME (range 0.01-10 mg l−1, r2 = 0.9990; limit of detection 1.55 μg l−1) was more sensitive than SDME (range 0.05-50 mg l−1, r2 = 0.9984; limit of detection 3.42 μg l−1), and was inexpensive, rapid and convenient. Tolerance of excess of iodate has permitted the application of this method in the determination of ethylene glycol in motor oil; the average recovery on spiked sample was 98.6% with R.S.D. of 4.2%.  相似文献   

11.
A new method is proposed for the chemiluminescent determination of the pesticide 3-indolyl acetic acid by means of an flow injection analysis system. The chemiluminescence emission is obtained by oxidation of the analyte with Ce (IV) in nitric acid and presence of β-cyclodextrine.The continuous-flow method allows the determination of 159 samples h−1 of 3-indolyl acetic acid in an interval of concentrations over the range 0.5-15.0 mg l−1. The limit of detection was 0.1 μg l−1 and the R.S.D. (n, 17) at 2.0 mg l−1 of the pesticide level was 2.7%. The method was applied to water samples.  相似文献   

12.
In this paper, we proposed a procedure for the determination of iron(II) and total iron in wine samples employing molecular absorption spectrophotometry. The ligand used is 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol (Br-PADAP) and the chromogenic reaction in absence or presence of ascorbic acid (reducing agent) allows the determination of iron(II) or total iron, respectively. The optimization step was performed using a multivariate technique (Box Behnken design) involving the factors pH, acid ascorbic concentration and reaction time.The method allows the determination of iron(II) and iron(III) in wine samples, with limits of detection and quantification 0.22 and 0.72 μg L−1, respectively. The precision expressed as relative standard deviation (R.S.D.) was 1.43 and 0.56% (both, n = 11) for content of iron(II) in wine samples of 1.68 and 4.65 mg L−1, and 1.66 and 0.87% (both, n = 11) for content of total iron in wine samples of 1.72 and 5.48 mg L−1.This method was applied for determination of iron(II) and total iron in six different wine samples. In these, the iron(II) content varied from 0.76 to 4.65 mg L−1 and from 1.01 to 5.48 mg L−1 for total iron. The results obtained in the determination of total iron by Br-PADAP method were compared with those that were performed after complete acid digestion in open system and determination of total iron employing FAAS. The method of regression linear was used for comparison of these results and demonstrated that there is no significant difference between the results obtained with these two procedures.  相似文献   

13.
Ohno S  Teshima N  Sakai T  Grudpan K  Polasek M 《Talanta》2006,68(3):527-534
A sequential injection (SI) method in a lab-on-valve (LOV) format for simultaneous spectrophotometric determination of copper and iron has been devised. The detection chemistry is based on the complex formation of 2-(5-bromo-2-pyridylazo)-5-[N-n-propyl-N-(3-sulfopropyl)amino]aniline (5-Br-PSAA) with copper(II) and/or iron(II) at pH 4.6. Copper(II) reacts with 5-Br-PSAA to form the complex which has an absorption maximum at 580 nm but iron(III) does not react. In the presence of a reducing agent only iron(II)-5-Br-PSAA complex is formed and detected at 558 nm. Under the optimum experimental conditions, the determinable ranges are 0.1-2 mg l−1 for copper and 0.1-5 mg l−1 for iron, respectively, with a sampling rate of 18 h−1. The limits of detection are 50 μg l−1 for copper and 25 μg l−1 for iron. The relative standard deviations (n = 15) are 2% for 0.5 mg l−1 copper and 1.8% for 0.5 mg l−1 iron when determined in standard solutions. The recoveries range between 96 and 105% when determining 0.25-2 mg l−1 of copper and 0.2-5 mg l−1 of iron in artificial mixtures at copper/iron ratios of 1:10 to 5:1. The proposed SI-LOV method is successfully applied to the simultaneous determination of copper and iron in multi-element standard solution and in industrial wastewater samples.  相似文献   

14.
A first order derivative spectrophotometric method has been developed for the simultaneous determination of bismuth and zinc by dithizone without time-consuming extraction step. The reactions of bismuth and zinc with dithizone in a three component solution prepared in water, acetone and n-propanol mixture have been investigated. These cations react with dithizone in this mixture at pH 5.0, forming coloured complex that is stable for at least 2 h. The linear range in D evaluation was between 3.0 × 10−6 and 1.8 × 10−5 mol l−1 for Zn and 2.4 × 10−6 and 1.2 × 10−5 mol l−1 for Bi. The limits of detection for the analytical procedure were found 0.05 mg l−1 for both cations. The relative standard deviations for the determination of 0.5 mg l−1 bismuth and 0.5 mg l−1 zinc were 1.2 and 1.1%, respectively, for five determinations. The procedure is simple, rapid and reliable. This method was applied to the determination of bismuth and zinc in the pharmaceutical materials successfully. Good agreement was achieved between the results obtained by the proposed and comparative methods.  相似文献   

15.
16.
In this study, a multiwavelength UV spectral deconvolution (UVSD) procedure is proposed as a robust and simple procedure for direct estimation of carbon and nitrate contents in soil water extracts. Soil samples were collected from an open-air field cultivated with maize at 3 different depths, 30 cm each, between 0 and 90 cm of soil surface during a period of 7 months. Fractionation of water extractable organic carbon (WEOC) into hydrophobic (Hpo-WEOC), transphilic (Tpi-WEOC), and hydrophilic (Hpi-WEOC) fractions is performed using XAD-8 and XAD-4 resins connected in series. In order to perform UVSD, 3 representative reference spectra of WEOC fractions were selected automatically, in addition to a 4th spectrum representative of NO3 selected manually in order to compose the deconvolution basis. The restitution of UV spectra was made in the range 235-350 nm. Through exploitation of soil water extract UV spectra, it was possible in a single-step deconvolution procedure to determine the organic carbon (mg C l−1) and NO3 (mg l−1) concentrations and to differentiate and to quantitatively estimate carbon content of WEOC fractions. Statistical tests indicated satisfactory correlations between values estimated using UVSD and those determined by conventional reference methods for each parameter determined. The ranges of concentrations of carbon and NO3 in the soil water extracts studied are between 3.00 and 15.00 mg C l−1 and 60-300 mg l−1, respectively. The limits of quantification (LQ) and of detection (LD) of WEOC and NO3 were found to be 0.10 and 0.05 mg C l−1, and 0.10 and 0.03 mg l−1, respectively.  相似文献   

17.
A new procedure for determination of biogenic amines (BA): histamine, phenethylamine, tyramine and tryptamine, based on the derivatization reaction with 2-chloro-1,3-dinitro-5-(trifluoromethyl)-benzene (CNBF), is proposed. The amines derivatives with CNBF were isolated and characterized by X-ray crystallography and 1H, 13C, 19F NMR spectroscopy in solution. The novelty of the procedure is based on the pure and well-characterized products of the amines derivatization reaction. The method was applied for the simultaneous analysis of the above mentioned biogenic amines in wine samples by the reversed phase-high performance liquid chromatography. The procedure revealed correlation coefficients (R2) between 0.9997 and 0.9999, and linear range: 0.10–9.00 mg L−1 (histamine); 0.10–9.36 mg L-1 (tyramine); 0.09–8.64 mg L−1 (tryptamine) and 0.10–8.64 mg L−1 (phenethylamine), whereas accuracy was 97%–102% (recovery test). Detection limit of biogenic amines in wine samples was 0.02–0.03 mg L−1, whereas quantification limit ranged 0.05–0.10 mg L−1. The variation coefficients for the analyzed amines ranged between 0.49% and 3.92%. Obtained BA derivatives enhanced separation the analytes on chromatograms due to the inhibition of hydrolysis reaction and the reduction of by-products formation.  相似文献   

18.
In this paper, the conversion of azoxystrobin in a strongly fluorescent degradation product by UV irradiation with quantitative purposes and its fluorimetric determination are reported for the first time. A multicommuted flow injection-solid phase spectroscopy (FI-SPS) system combined with photochemically-induced fluorescence (PIF) is developed for the determination of azoxystrobin in grapes, must and wine. Grape samples were homogenized and extracted with methanol and further cleaned-up by solid-phase extraction on C18 silica gel. Wine samples were solid-phase extracted on C18 sorbent using dichloromethane as eluent. Recoveries of azoxystrobin from spiked grapes (0.5-2.0 mg Kg−1), must (0.5-2.0 μg mL−1) and wine (0.5-2.0 μg mL−1) were 84.0-87.6%, 95.5-105.9% and 88.5-111.2%, respectively. The quantification limit for grapes was 0.021 mg Kg−1, being within European Union regulations, and 18 μg L−1 and 8 μg L−1 for must and wine, respectively.  相似文献   

19.
Fotini S. Kika 《Talanta》2007,71(3):1405-1410
The present work reports the first sequential injection (SI) method for the spectrophotometric determination of Ti(IV). The method is based upon the reaction of Ti(IV) with chromotropic acid (CA) in acidic medium to form a water-soluble complex (λmax = 420 nm). The chemical and instrumental variables of the system that affected the reaction were studied. Selectivity was greatly enhanced using ascorbic acid. A linear calibration graph was obtained in the range 0.2-10.0 mg l−1 Ti(IV) at a sampling frequency of 24 h−1. The precision was satisfactory (sr = 1.5% at 5.0 mg l−1 Ti(IV), n = 12) and the 3σ limit of detection, cL, was 0.7 mg l−1 (n = 10). The developed method proved to be adequately selective and was applied successfully to the analysis of real samples (dental implant and natural Moroccan phosphate rock) giving accurate results based on recovery studies (98-105%).  相似文献   

20.
This paper reports an indirect flow-injection (FI) method for the determination of the anti-hyperthyroid drugs methimazole and carbimazole in pharmaceuticals. The method was based on the inhibition that these thioimidazole drugs caused on the Cu(II)-catalysed chemiluminescence (CL) reaction between luminol and H2O2. The CL reaction was induced on-line and injection of the sample produced negative peaks as a result of the Cu(II) complexation by the analytes. The height of the FI peaks was proportional to the drug concentration in the sample. The linear range was 2-100 and 3-120 mg l−1 for methimazole and carbimazole, respectively. The relative standard deviation was 1.9% for methimazole and 2.1% for carbimazole at the 50 mg l−1 level (n=10). Common excipients present in pharmaceutical tablets were found not to interfere with the analysis. The method was applied to the determination of methimazole and carbimazole in pharmaceutical formulations with recoveries in the range 100±4%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏