首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The development of a highly sensitive amperometric sensor for nitrite using a glassy carbon electrode modified with alternated layers of iron(III) tetra-(N-methyl-4-pyridyl)-porphyrin (FeT4MPyP) and cobalt(II) tetrasulfonated phthalocyanine (CoTSPc) is described. The modified electrode showed an excellent catalytic activity and stability for the nitrite oxidation decreasing the peak potentials about 200 mV toward less positive values and presenting much higher peak currents than those obtained on the bare GC electrode. A linear response range of 0.2-8.6 μmol l−1, with a sensitivity of 0.37 μA l μmol−1 and detection limit of 0.04 μmol l−1 were obtained with this sensor. The repeatability of the proposed sensor, evaluated in term of relative standard deviation, was verified to be 1.4% for 10 measurements of 0.2 μmol l−1 nitrite solution. Interference caused by common ions has been investigated in simulated mixtures containing high concentration level of interfering ions and the sensor was found to be tolerant against these ions. The developed sensor was applied for the nitrite determination in water samples and the results were in agreement with those obtained by a comparative method described in the literature. The average recovery for these samples was 100.1 (±0.7)%.  相似文献   

2.
A simple and robust time-based on-line sequential injection system for trace mercury determination via cold vapour atomic absorption spectrometry (CVAAS), employing a new integrated gas-liquid separator (GLS), which in parallel operates as reactor, was developed. Sample and reductant are sequentially loaded into the GLS while an argon flow delivers the released mercury vapour through the atomic absorption cell. The proposed method is characterized by the ability of successfully managing variable sample volume up to 30 ml in order to achieve high sensitivity. For 20 ml sample volume, the sampling frequency is 25 h−1. The calibration curve is linear over the concentration range 0.05-5.0 μg l−1 of Hg(II), the detection limit is cL = 0.02 μg l−1, and the relative standard deviation is sr = 2.6% at 1.0 μg l−1 Hg(II) level. The performance of the proposed method was evaluated by analyzing certified reference material and applied to the analysis of natural waters and biological samples.  相似文献   

3.
Metal ion-imprinted polymer particles have been prepared by copolymerization of methacrylic acid as monomer, trimethylolpropane trimethacrylate as cross-linking agent and 2,2′-azobisisobutyronitrile as initiator, in the presence of Hg(II)-1-(2-thiazolylazo)-2-naphthol complex. The separation and preconcentration characteristics of the Hg-ion-imprinted microbeads for inorganic mercury have been investigated by batch procedure. The optimal pH value for the quantitative sorption is 7. The adsorbed inorganic mercury is easily eluted by 2 mL 4 M HNO3. The adsorption capacity of the newly synthesized Hg ion-imprinted microbeads is 32.0 μmol g−1 for dry copolymer. The selectivity of the copolymer toward inorganic mercury (Hg(II)) ion is confirmed through the comparison of the competitive adsorptions of Cd(II), Co(II), Cu(II), Ni(II), Pb(II), Zn(II)) and high values of the selectivity and distribution coefficients have been calculated. Experiments performed for selective determination of inorganic mercury in mineral and sea waters showed that the interfering matrix does not influence the extraction efficiency of Hg ion-imprinted microbeads. The detection limit for inorganic mercury is 0.006 μg L−1 (3σ), determined by cold vapor atomic adsorption spectrometry. The relative standard deviation varied in the range 5-9 % at 0.02-1 μg L−1 Hg levels. The new Hg-ion-imprinted microbeads have been tested and applied for the speciation of Hg in river and mineral waters: inorganic mercury has been determined selectively in nondigested sample, while total mercury e.g. sum of inorganic and methylmercury, has been determined in digested sample.  相似文献   

4.
This paper describes a simple and highly selective method for the separation, preconcentration and spectrophotometric determination of extremely low concentration of mercury. The method is based on the flotation of an ion-associate of HgI42− and ferroin between aqueous and n-heptane interface at pH 5. The ion-associate was then separated and treated with ammonia and dithizone solutions to extract only the mercury chelate with CH2Cl2. The measurement is feasible when the volume of the water sample containing Hg(II) was varied over 50-800 ml. Beer's law was obeyed over the concentration range of 8 × 10−9 to 1.6 × 10−7 mol l−1 with an apparent molar absorptivity of 6.53 × 106 l mol−1 cm−1 for a 500 ml aliquot of the water sample. The detection limit (n = 7) was 5.0 × 10−10 mol l−1 and the R.S.D. (n = 5) for 8.0 × 10−7 mol l−1 of Hg(II) was 3.7%. A notable advantage of the method is that the determination of Hg(II) is free from the interference of almost all cations and anions found in the environmental and waste water samples. The determination of Hg(II) in tap, synthetic sea water and human hair samples was carried out by the present method and cold vapor atomic absorption spectrometry (CV-AAS). The results were satisfactorily comparable so that the applicability of the proposed method was confirmed to the real samples.  相似文献   

5.
A flow injection (FI) spectrophotometric method was proposed for the determination of chloride ion in natural waters. The determination of chloride was carried out by reaction with Hg(SCN)2 immobilized in an epoxy resin bead in a solid-phase reactor (SPR) and the thiocyanate ions released were determined spectrophotometrically at 480 nm after complexing reaction with Fe(III). The analytical curve for chloride was linear in the concentration range from 5.6 × 10−5 to 2.2 × 10−4 mol l−1 with a detection limit of 1.4 × 10−5 mol l−1. The relative standard deviation (R.S.D.) was 2.2% for a solution containing 2.2 × 10−4 mol l−1 (n = 10). The simple manifold allows a routine analytical frequency of 100 determinations per hour. The main advantage of the developed method is the 400% reduction of the Hg waste solution generated when compared to conventional methods for chloride determination based on the same spectrophotometric reaction.  相似文献   

6.
Di J  Bi S  Zhang F 《Talanta》2004,63(2):265-272
The electrochemical behavior of maltol on a glassy carbon (GC) electrode was investigated. The results were applied to differential pulse voltammetric determination of maltol in beverages pretreated by ultrafiltration. Under the optimum experimental conditions, the linear range is 1×10−5 to 6×10−4 mol l−1 maltol and the relative standard deviation for 0.4 mmol l−1 maltol is 0.6% (n=9). The detection limit was 5 μmol l−1. Furthermore, silica sol-gel film on GC electrode could be used as suitable selective membrane, which integrated selective membrane on the electrode and substituted for the pretreatment of ultrafiltration. Under the above conditions, maltol was determined by semi-differential linear sweep voltammetry at a silica sol-gel modified GC electrode in the concentration range of 5×10−6 to 5×10−4 mol l−1. The detection limit was 2 μmol l−1 and the relative standard deviation for 0.1 mmol l−1 maltol was 0.7% (n=7). The proposed method is of sensitivity, simplicity, rapidness and no contamination. It had been applied to the direct determination of maltol in beverages such as grape wines, drinks and beers without any pretreatment. The results obtained with the present method were satisfactory with those obtained by spectrophotometry. It could be used as a simple and practical method for the determination of the flavor enhancer maltol in beverages.  相似文献   

7.
A highly selective β-cyclodextrin polymer solid-phase spectrophotometric (β-CDPSPS) method is described for the determination of total mercury(II) sub microgram per liter. The methods are based on the chromogenic reaction of mercury(II) with 1,3-di-(4-nitrodiazoamino)-benzene (DNAAB) loaded on β-cyclodextrin polymer (β-CDP). In pH 10.0 borax buffer, Hg(II)-DNAAB complex on β-CDP gives a positive peak at 445 nm and a negative one at 545 nm. The absorbance was measured at two peaks and the net absorbance (As) was calculated between the difference of positive and negative peaks. The apparent molar absorptivity is 1.1 × 107 l mol−1 cm−1 (82-fold of it in solution) for 100 ml sample and the linear range of the determination is 0.062-250 μg l−1. The selectivity for coexistent ions was greatly improved, only silver(I) interfered with the mercury determination and the amount of the others was reduced 25-1000 times compared to previous solution method. The interference caused by silver(I) can be eliminated using tri-n-octylmethylammonium bromide as masking agent. The detection limit and the quantification limit were found to be 0.024 and 0.062 μg l−1, respectively. The relative standard deviation of ten replicate determinations of 5.0 μg mercury(II) in 100 ml sample was of 2.4%. The method was validated by analyzing the water and soil reference materials and successfully applied to the determination of mercury(II) in locally collected water and dust samples.  相似文献   

8.
The use of selective pre-concentration and differential pulse anodic stripping voltammetry (DPASV) using a carbon paste electrode modified (CPEM) with spinel-type manganese oxide has been proposed for the determination of lithium ions content in natural waters. The new procedure is based on the effective pre-concentration of lithium ions on the electrode surface containing spinel-type Mn(IV) oxide with the reduction of Mn(IV) to Mn(III) and consequently the lithium ions intercalation (insertion) into the spinel structure. The best DPASV response was reached for an electrode composition of 25% (m/m) spinel-type MnO2 in the paste, 0.1 mol l−1 tris(hydroxymethyl)aminomethane (TRIS) buffer solution of pH 8.3, scan rate of 5 mV s−1, accumulation potential of 0.3 V versus saturated calomel reference electrode (SCE), pre-concentration time of 30 s and potential pulse amplitude of 50 mV. In these experimental conditions, the proposed methodology responds to lithium ions in the concentration range of 2.8×10−6 to 2.0×10−3 mol l−1 with a detection limit of 5.6×10−7 mol l−1. The determination of the lithium ions content in different samples of natural waters samples using the proposed methodology and atomic absorption spectrophotometry are in agreement at the 95% confidence level and within an acceptable range of error.  相似文献   

9.
Di J  Zhang F 《Talanta》2003,60(1):31-36
This paper described the determination of trace manganese using linear sweep voltammetry at a pretreatment glassy carbon electrode. The glassy carbon electrode pretreated by electrochemical method in the 0.1 mol l−1 NaOH solution greatly improved the electrode responsibility in the determination of manganese(II). The barrier to the detection of low manganese concentration was overcome by means of autocatalytic effect of manganese oxide deposited on the electrode in advance. Under the optimum experiments condition (0.04 mol l−1 NH3-NH4Cl buffer solution, pH 9.0), the linear range was 4×10−8 to 1×l0−6 mol l−1 Mn(II) for linear sweep voltammetry and 1×10−9 to 4×10−8 mol l−1 Mn(II) for convolution voltammetry. The relative standard deviation for 2×10−8 mol l−1 Mn(II) is 3.4%. The proposed method is simple, rapid, sensitive and selective. It had been applied to the determination of trace manganese in samples with satisfactory results.  相似文献   

10.
This study describes the functionalization of biopolymer chitosan, using the complexing agent 8-hydroxyquinoline (oxine) by reaction of diazotization. The chelating resin was characterized by degree of deacetylation, infrared, Raman spectroscopy. The efficiency of the chelating resin and accuracy of the proposed method was evaluated by the metal ion recovery technique in the analysis of potable water, lake water, seawater and a certified sample of oyster tissue. The metal ions Cd(II) and Cu(II) in the samples were previously enriched in a minicolumn and flow injection flame atomic absorption spectrometry (FI-FAAS) determined the concentrations of the analytes. The chelating resin exhibited high selectivity for Cd(II) at pH 7 and for Cu(II) at pH 10. The eluent concentration was tested by the use of HNO3 in concentrations of 0.1-3 mol l−1 maximum response was obtained at 0.5 mol l−1 for Cd(II) and Cu(II), with R.S.D. values of 0.4%. The analytes gave relative standard deviations (R.S.D.) of 1.5 and 0.7% for solutions of Cd(II) and Cu(II), respectively (n = 7) containing 20 μg l−1 of the metal ions, defining a high reproducibility. The limits of detection (LOD) were 0.1 μg l−1 for Cd(II) and 0.4 μg l−1 for Cu(II). The analytical properties of merit were obtained using the parameters previously optimized with preconcentration time of 90 s. The chelating resin showed chemical stability within a wide range of pH and the efficiency was not altered for the preconcentration of the metal ions during all the experiments.  相似文献   

11.
A flow-batch system was developed for the determination of Fe(III) in estuarine waters with high variability in salinity. The method is based on the catalytic effect of iron(III) on the oxidation rate of N,N-dimethyl-p-phenylenediammonium dichloride (DmPD) by hydrogen peroxide and the formed product is spectrophotometrically monitored at 554 nm. A controlled addition of sodium chloride to every assayed sample is accomplished for in-line individual salinity matching.The proposed system processes about 30 samples h−1 and yields reproducible results. Relative standard deviations were estimated as <1.5% after 10 injections of typical samples (10.0-50.0 μg l−1 Fe; ca. 0.5 mol l−1 Cl). Synthetic samples (15.0 μg l−1 Fe; 0.25-1.0 mol l−1 NaCl) were efficiently processed, and no significant differences in results were found at a probability level of 99.7%. The method works for the full range of salinities. Only 120 μg DmPD are consumed per determination. The analytical curve is linear up to about 60 μg l−1 Fe (r>0.999; n=5) and the detection limit is 5 μg l−1 Fe. Results are in agreement with graphite furnace atomic absorption spectrometry.  相似文献   

12.
Quintino MS  Angnes L 《Talanta》2004,62(2):231-236
This paper presents a simple, rapid and reproducible method of analysis of salbutamol in pharmaceutical products, utilizing batch injection analysis (BIA) associated with amperometric detection. A study of salbutamol oxidation demonstrated a strong dependence between electrode fouling and pH. All determinations were done utilizing a glassy carbon electrode in presence of 3.0 mol l−1 NaOH. A large linear dynamic range from 8×10−7 to 2×10−4 mol l−1 was obtained by using an injected volume of 100 μl with a detection limit of 2.5×10−7 mol l−1. R.S.D. of 0.92% for 50 successive injections of 4×10−6 mol l−1 of salbutamol and a sample throughput of 60 samples per hour were achieved. The method was applied for salbutamol quantification in syrups.  相似文献   

13.
The present work reports the development of a methodology for the direct determination of lead in high saline waters derived from petroleum exploration employing electrothermal atomic absorption spectrometry with permanent Ir-W and HF as modifiers. These waters, so-called produced waters, have complex composition containing several types of organic and inorganic substances. In order to attain best conditions (highest analytical signal besides lowest background) for the methodology studies about the effect of several variables and the convenient calibration strategy were performed. Also, the efficiency of other modification approaches was evaluated. At best conditions, pyrolysis and atomization temperature were 800 and 2200 °C, respectively, when the modifiers cited above were utilized. Obtained results indicate that, in this kind of sample, lead can be determined by standard addition method or employing external calibration with standard solutions prepared in 0.8 mol l−1 NaCl medium. In order to evaluate the accuracy of the procedure, a recovery test was performed with six spiked samples of produced waters. The detection limit, quantification limit and the relative standard deviation in 0.8 mol l−1 NaCl were also calculated and the values are 1.5 μg l−1, 5.0 μg l−1 and 5.0% (at 10 μg l−1 level), respectively.  相似文献   

14.
Liang Y  Yuan D  Li Q  Lin Q 《Analytica chimica acta》2006,571(2):184-190
Solid-phase extraction technique had been applied to extract molybdophosphoric heteropoly acid (MoP) paired with cetyltrimethylammonium bromide (CTAB) from seawater matrix using C18 sorbent. Chemiluminescence emission could be generated via MoP reaction with alkaline luminol. Based on these, a novel on-line solid-phase extraction method coupled with flow injection (FI) analysis and luminol chemiluminescence detection had been established to determine ultratrace orthophosphate in seawater. The MoP-CTAB compound could be efficiently extracted on an in-line Sep-Pak C18 cartridge, and rapidly eluted by 0.3 mol l−1 sulphuric acid-ethanol solution. Then the compound was reduced by luminol to produce chemiluminescence light, which could be detected using a luminescence analyzer. Experimental parameters were optimized using a univariate experimental design. Using artificial seawater with salinity of 35 as a matrix, the standard curve with a linear range between 0.005 and 0.194 μmol l−1 had been obtained, and the recovery and the detection limit of the proposed method were found to be 92.5% and 0.002 μmol l−1, respectively. The relative standard deviation (R.S.D.), which was determined over eight hour, was 4.66% (n = 7) for the artificial seawater at a concentration of 0.097 μmol l−1 orthophosphate. Si of 200 μmol l−1 would not interfere with the detection of 0.012 μmol l−1 orthophosphate compound. Three typical seawater samples were analyzed using both the proposed method and the magnesium hydroxide-induced coprecipitation (MAGIC) method, and the results of the two methods showed no significant difference using the t test. Compared to the MAGIC method, the proposed method was more sensitive, time saving and easy for on-line analysis.  相似文献   

15.
A modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) and 3-(4-methoxybenzylideneamino)-2-thioxothiazolodin-4-one as a new synthesized Schiff base was constructed for the simultaneous determination of trace amounts of Hg(II) and Pb(II) by square wave anodic stripping voltammetry. The modified electrode showed an excellent selectivity and stability for Hg(II) and Pb(II) determinations and for accelerated electron transfer between the electrode and the analytes. The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as pH, deposition potential and deposition time were optimized for the purpose of determination of traces of metal ions at pH 3.0. Under optimal conditions the limits of detection, based on three times the background noise, were 9.0 × 10−4 and 6.0 × 10−4 μmol L−1 for Hg(II) and Pb(II) with a 90 s preconcentration, respectively. In addition, the modified electrode displayed a good reproducibility and selectivity, making it suitable for the simultaneous determination of Hg(II) and Pb(II) in real samples such as sea water, waste water, tobacco, marine and human teeth samples.  相似文献   

16.
The characteristics, performance, and application of an electrode, namely, Pt|Hg|Hg2(PABzt)2| graphite, where PABzt stands for p-aminobenzoate ion, are described. This electrode responds to PABzt with sensivity of (58.1±1.0) mV per decade over the range 1.0×10−4 to 1.0×10−1 mol l−1 at pH 6.5-8.0 and a detection limit of 3.2×10−5 mol l−1. The electrode shows easy construction, fast response time (within 10-30 s), low-cost, and excellent response stability (lifetime greater than 6 months, in continuous use). The proposed sensor displayed good selectivity for p-aminobenzoate in the presence of several substances, especially, concerning carboxylate and inorganic anions. It was used to determine p-aminobenzoate in pharmaceutical formulations by means of the standard additions method. The results obtained by using this electrode compared very favorably with those given by an HPLC procedure.  相似文献   

17.
A flow injection analysis (FIA) method using on-line separation and preconcentration with a novel metal scavenger beads, QuadraSil™ TA, has been developed for the ICP-OES determination of traces of palladium. QuadraSil TA contains diethylenetriamine as a functional group on spherical silica beads and shows the highest selectivity for Pd(II) at pH 1 (0.1 mol l−1 hydrochloric acid) solution. An aliquot of the sample solution prepared as 0.1 mol l−1 in hydrochloric acid was passed through the QuadraSil TA column. After washing the column with the carrier solution, the Pd(II) retained on the column was eluted with 0.05 mol l−1 thiourea solution and the eluate was directly introduced into an ICP-OES. The proposed method was successfully applied to the determination of traces of palladium in JSd-2 stream sediment certified reference material [0.019 ± 0.001 μg g−1 (n = 3); provisional value: 0.0212 μg g−1] and SRM 2556 used auto catalyst certified reference material [315 ± 4 μg g−1 (n = 4); certified value: 326 μg g−1]. The detection limit (3σ) of 0.28 ng ml−1 was obtained for 5 ml of sample solution. The sample throughputs for 5 ml and 100 μl of the sample solutions were 10 and 15 h−1, respectively.  相似文献   

18.
The pyrethroid lambda-cyhalothrin is a common insecticide which is widespread in the environment. A study of the electrochemical reduction of the pesticide on a hanging mercury drop electrode (HMDE) was performed as basis for the development of a sensitive analytical method for determination of lambda-cyhalothrin in natural samples. Two electrochemical techniques—cyclic voltammetry (CV) and differential pulse voltammetry (DPV)—were applied. The study was performed in the pH range 2-13 using Britton-Robinson (B-R) buffer to control the pH of the measuring solutions and tetrabutylammonium chloride (TBAC) salt as supporting electrolyte. In DPV, a single reduction peak was observed at both pH<4.0 and pH>10.5 while two cathodic peaks were produced in the pH range 4.0-10.5. The results showed that the reduction of lambda-cyhalothrin in the measuring solution is irreversible. The limiting current was found to be diffusion-controlled and free of adsorption of the electroactive species to HMDE over the whole pH range tested. For the analytical DPV method running at pH 2 the relationship between peak current and lambda-cyhalothrin concentration was linear up to 500 μg l−1 (1.1×10−6 mol l−1) with a detection limit of 2.5 μg l−1. The repeatability in terms of relative standard deviation (n=10) was in the order of 3.5% at concentration levels of 5 and 10 μg l−1. A DPV method for determining lambda-cyhalothrin in the agrochemical formulation Karate, spiked soil and well water was developed. The recovery was about 94% in well water and 92% in soil samples at concentration range of 0.05-0.5 μg l−1 and 0.05-0.5 μg g−1, respectively.  相似文献   

19.
A procedure involving bead-injection concept and sequential determination of copper and mercury ions in river-water samples is proposed. The method is based on the solid-phase extraction of both metal ions on the same beads surface (Chelex 100 resin) and in their subsequent reaction with the colorimetric reagents (APDC and Dithizone for copper and mercury ions, respectively). For this task, a resin mini-column is established in the optical path by the selection, introduction and trapping of a defined volume of the Chelex-100 resin beads suspension in the flow system. The passage of the sample solution through the resin mini-column promotes the sorption of Cu(II) ions and, making the APDC colorimetric reagent flows through the beads, the formation of the coloured complex on the solid phase surface occurs. The absorbance of the formed APDC-Cu complex is then monitored at 436 nm and the spent beads are discarded. Packing another resin mini-column in the flow cell and repeating the concentration step it is possible to carried out the mercury determination by using Dithizone as reagent. The absorbance of the Dithizone-Hg complex is monitored at 500 nm. After each measurement, the spent beads are wasted and a new portion of fresh one is trapped in the system, letting it ready for the next measurement. The bead injection system is versatile and can be used to concentrate different sample volumes, which permits the determination of a wide range of copper and mercury ions concentrations. When the sample-selected volumes are 100 and 1000 μl the analytical ranges were 5.0 up to 500.0 μg l−1 and 2.5 up to 30.0 μg l−1 for Cu(II) and Hg(II) ions, respectively. Under these conditions, the detection limit was estimated as 0.63 and 0.25 μg l−1 for copper and mercury ions determination. The system consumes 2 mg of Chelex 100 resin beads, 0.20 mg of APDC or 1.25 mg of Dithizone per determination and the traditional organic solvent extraction methodology, normally used in connection with APDC and Dithizone reagents, is not used here which permits to classify the present method as green.  相似文献   

20.
The paper presents the first report on fabrication and application of a user friendly and mercury free electrochemical sensor, with the renewable bismuth bulk annular band working electrode (RBiABE), in stripping voltammetry (SV). The sensor body is partly filled with the internal electrolyte solution, in which the RBiABE is cleaned and activated before each measurement. Time of the RBiABE contact with the sample solution is precisely controlled. The usefulness of this sensor was tested by Ni(II) and Co(II) traces determination by means of differential pulse adsorptive stripping voltammetry (DP AdSV), after complexation with dimethylglyoxime (DMG) in ammonia buffer (pH 8.2). The experimental variables (composition of the supporting electrolyte, pre-concentration potential and time, potential of the RBiABE activation, and DP parameters), as well as possible interferences, were investigated. The linear calibration graphs for Ni(II) and Co(II), determined individually and together, in the range from 1 × 10−8 to 70 × 10−8 mol L−1 and from 1 × 10−9 to 70 × 10−9 mol L−1 respectively, were obtained. The calculated limit of detection (LOD), for 30 s of the accumulation time, was 3 × 10−9 mol L−1 for Ni(II) in case of a single element’s analysis, whereas the LOD was 5 × 10−9 mol L−1 for Ni(II) and 3 × 10−10 mol L−1 for Co(II), when both metal ions were measured together. The repeatability of the Ni(II) and Co(II) adsorptive stripping voltammetric signals obtained at the RBiABE were equal to 5.4% and 2.5%, respectively (n = 5). Finally, the proposed method was validated by determining Ni(II) and Co(II) in the certified reference waters (SPS-SW1 and SPS-SW2) with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号