首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Fujiwara Y  Amao Y 《Talanta》2004,62(3):655-660
Optical oxygen-sensitivity using pyrene carboxylic acid with long alkyl chain (1-pyrenedecanoic acid and 1-pyrenedodecanoic acid) and myristic acid co-chemisorption layer was controlled by varying the molar ratio of myristic acid to pyrene carboxylic acid. The ratio I0/I100, where I0 and I100 represent the detected fluorescence intensities from a substrate exposed to 100% argon and 100% oxygen, respectively, is used as an indicator of the sensitivity of the sensing film. At a composition ratio of 1 pyrene carboxylic acid to 10 myristic acids, the I0/I100 attained its maximum value and then the ratio decreased with increase in the molar ratio of myristic acid to pyrene carboxylic acid. The Stern-Volmer constant (KSV) also attained its maximum value at a composition ratio of one pyrene carboxylic acid to ten myristic acids and then the ratio decreased with increase in the molar ratio of myristic acid to pyrene carboxylic acid. The oxygen-sensitivity of optical sensor using pyrene carboxylic acid is optimized by myristic acid co-chemisorption.  相似文献   

2.
In this study, a sensitive optical waveguide (OWG) sensor for the detection and identification of volatile organic compounds (VOCs) was reported. The sensing membrane is constructed by immobilization of peroxopolytungsten acid (PTA) thin film over a single-mode potassium ion (K+) exchanged glass OWG by spin-coating method. A laser beam was coupled into and out of the glass optical waveguide using prism couplers, and dry air functioned as a carrier gas. The sensor was tested for various volatile organic compounds (VOCs), and it showed higher response to the chlorobenzene gas compared to other VOCs. Therefore, we used the OWG sensor to detect chlorobenzene gas as a typical example of VOCs. The sensor exhibits a linear response to chlorobenzene gas in the range of 0.4-1000 ppm with rapid response and good reversibility. The constructed sensor is easy to fabricate and it has some unique qualities which can be characterized as inexpensive, sensitive, and reusable.  相似文献   

3.
An optical sensor for mercury ion (Hg2+), based on quenching the fluorescence of the sensing reagent porphyrin immobilized in plasticized poly(vinyl chloride) (PVC) membrane, has been developed. The responses to mercury ion were compared for the sensors modified with three porphyrin compounds including 5,10,15,20-tetraphenylporphyrin (TPP), tetra(p-dimethylaminophenyl)porphyrin (TDMAPP) and tetra(N-phenylpyrazole) porphyrin (TPPP). Among them, TDMAPP showed the most remarkable response to Hg2+. The drastic decrease of the TDMAPP fluorescence intensity was attributed to the formation of a complex between TDMAPP and Hg2+, which has been utilized as the fabrication basis of a Hg2+-sensitive fluorescence sensor. The analytical performance characteristics of the TDMAPP modified sensor was investigated. The response mechanism, especially involving the response difference of three porphyrin compounds, was discussed in detail. The sensor can be applied to the quantification of Hg2+ with a linear range covering from 4.0 × 10−8 mol L−1 to 4.0 × 10−6 mol L−1. The limit of detection was 8.0 × 10−9 mol L−1. The sensor exhibited excellent reproducibility, reversibility and selectivity. Also, the TDMAPP-based sensor was successfully used for the determination of Hg2+ in environmental water samples.  相似文献   

4.
Lam H  Rao G  Loureiro J  Tolosa L 《Talanta》2011,84(1):65-70
In measuring specific conditions in the real world, there are many situations where both the oxygen concentration and the temperature have to be determined simultaneously. Here we describe a dual optical sensor for oxygen and temperature that can be adapted for different applications. The measurement principle of this sensor is based on the luminescence decay times of the oxygen-sensitive ruthenium complex tris-4,7-diphenyl-1,10-phenanthroline ruthenium(III) [Rudpp] and the temperature-sensitive europium complex tris(dibenzoylmethane) mono(5-amino-1,10-phenanthroline)europium(III) [Eudatp]. The excitation and emission spectra of the two luminophores overlap significantly and cannot be discriminated in the conventional way using band pass filters or other optical components. However, by applying both the frequency and time domain techniques, we can separate the signals from the individual decay time of the complexes. The europium complex is entrapped in a poly(methyl methacrylate) (PMMA) layer and the ruthenium complex is physically adsorbed on silica gel and incorporated in a silicone layer. The two layers are attached to each other by a double sided silicone based tape. The europium sensing film was found to be temperature-sensitive between 10 and 70 °C and the ruthenium oxygen-sensitive layer can reliably measure between 0 and 21% oxygen.  相似文献   

5.
Wang X  Zeng H  Zhao L  Lin JM 《Talanta》2006,70(1):160-168
A bifurcated optical fiber based chemical sensor for continuous monitoring of 2,6-dinitrophenol (2,6-DNP) has been proposed based on the reversible chemical reaction between a novel functional poly(vinyl chloride) (PVC) as the sensing material and the analytes. The functional PVC (FPVC), containing a fluorescent curcumin moiety, was synthesized by the nucleophilic substitution of a fraction of the chlorine atoms bound to the PVC backbone by curcumin. When plasticized in a membrane of 5 μm thickness, FPVC extracts 2,6-DNP from aqueous solution into the bulk membrane phase and reacts with the analyte to form a complex with low fluorescence efficiency through hydrogen bonding. Formation of the complex gave a significant fluorescence quenching which is suitable for signalling the occurrence of the host-guest interaction. At pH 3.50, the sensor exhibits a dynamic detection range from 2.5 × 10−6 to 7.0 × 10−3 mol L−1 with a limit of detection of 1.0 × 10−6 mol L−1. As 2,6-DNP can provide an optimal space geometry matches to the formation of hydrogen bonds, the sensor shows excellent selectivity for 2,6-DNP over other nitrophenols. The forward and reverse response time (t95) of the sensor both was within 1 min. The repeatability, reproducibility, and lifetime of the sensor were also satisfied. The sensor was applied to determine 2,6-DNP in water samples successfully.  相似文献   

6.
This study describes the preparation and the characterization of a new thiol-ene based polymeric fluorescence sensor by photo initiated polymerization of trimethylolpropane tris(3-mercaptopropionate), 2-hydroxyethylacrylate, and 2,4,6-triallyloxy-1,3,5-triazine which are used as monomers and also a photo initiator (2,2-dimethoxy-2-phenylacetophenone) for its usage as optical sensor for gold ions. The thiol-ene based polymeric membrane sensor was characterized by using attenuated total reflectance-fourier transform infrared spectroscopy (ATR-FTIR) and scanning electron microscopy (SEM). The response characteristics of the sensors including dynamic range, pH effect, response time, and the effect of foreign ions were investigated. Fluorescence spectra showed that the excitation/emission maxima of the membrane were at 379/425 nm, respectively  相似文献   

7.
Andreu Y  de Marcos S  Castillo JR  Galbán J 《Talanta》2005,65(4):1045-1051
An analytical method based on the absorption changes of chemically polymerised polyaniline at 700 nm is proposed for the determination of Vitamin C. Vitamin C produces a polyaniline film reduction, originating changes in its absorbance proportional to the Vitamin C concentration. The optimum reaction conditions and the analytical characteristics have been studied. The linear response of the method ranged from 0.10 to 1.0 mg l−1 for a 6 min reaction time and from 1.0 to 8.0 mg l−1 for a 2 min reaction time. Reproducibility, expressed as the coefficient of variation, was 0.8% (6 min reaction time) and 2.3% (2 min reaction time) (n = 10). The method has been applied to Vitamin C determination in pharmaceutical preparations and commercial fruit juices. The results were compared with those obtained by the 2,6-dichlorophenolindophenol titration method (the AOAC Official Method) and no systematic errors were observed.  相似文献   

8.
以苯胺为功能单体和交联剂,氯霉素(chloramphenicol,CAP)为模板分子,采用电化学聚合法(循环伏安法)在金电极上合成了对CAP具有快速响应能力的聚苯胺分子印迹膜;结合差示脉冲伏安法建立了针对氯霉素的检测方法,并将所制备的聚苯胺分子印迹膜用作电化学传感器以测定氯霉素眼药水中的氯霉素.结果表明,所制备的聚苯胺分子印迹膜具有制备简单、响应快速、灵敏度高、再生性能良好等特点;其对氯霉素眼药水中的氯霉素的检测结果令人满意,有望用于实际样品中氯霉素的检测.  相似文献   

9.
Hu YJ  Tan SZ  Shen GL  Yu RQ 《Analytica chimica acta》2006,570(2):170-175
A novel optical sensor based on covalent immobilization for picric acid assay has been described. To improve the stability of the sensor, a terminal double bond was attached to the fluorescent compound, 3-amino-9-ethylcarbazole (AEC), via methacryloyl chloride. The resultant compound, 3-(N-methacryloyl) amino-9-ethylcarbazole (MAEC) was copolymerized with 2-hydroxypropyl methacrylate on surface-modified quartz glass plates by UV irradiation. The resulting optical sensor (optode membrane) was used to determine picric acid based on fluorescence quenching. It shows a linear response toward picric acid in the concentration range of 9.33 × 10−8 to 9.33 × 10−5 mol l−1, with rapid response, high stability and good selectivity to picric acid.  相似文献   

10.
Fatty hydroxamic acid (FHA) immobilized in polyvinyl chloride (PVC) has been studied as a sensor element of an optical fibre chemical sensor for V(V). By using this instrument, V(V) in solution has been determined in the log concentration range of 0-2.5 (i.e. 1.0-300 mg/L). The detection limit was 1.0 mg/L. The relative standard deviation (R.S.D.) of the method for the reproducibility study at V(V) concentration of 200 mg/L and 300 mg/L were calculated to be 2.9% and 2.0%, respectively. Interference from foreign ions was also studied at 1:1 mole ratio of V(V):foreign ions. It was found that, Fe(III) ion interfered most in the determination of vanadium(V). Excellent agreement with ICP-AES method was achieved when the proposed method was applied towards determination of V(V).  相似文献   

11.
A fluorescent chemosensor for Ag(I) as a new family of peripherally functionalized zinc-phthalocyanine, 2(3),9(10),16(17),23(24)-tetrakis-{6-(-benzofuran-2-carboxylate)-hexylthio} phthalocyaninatozinc(II) {Zn[Pc(β-S(CH2)6OCOBz-furan)4], (ZnPcBzF), (3), which was derivated from 6-(3,4-dicyanophenylthio)-hexyl–2-benzofuranate (BzF), (2), has been synthesized and fully characterized by elemental analysis, FT-IR, 1H and 13C NMR, MS (ESI and Maldi-TOF). An optical silver ion (Ag(I)) sensor based on the fluorescence quenching of benzofuran moiety and ZnPc core was developed. Both absorbance and fluorescence spectra of ZnPcBzF, (3) exhibit distinct changes in visible region in response to treatment with Ag(I) ion in solution. Such properties make compound ZnPcBzF, (3) intriguing candidates for incorporation into the transducer layer in optically based chemical sensors.  相似文献   

12.
We developed a new fluorescent sensor (PPC-S) for Hg2+ based on the aggregation-induced emission (AIE) of pyrazolo[3,4-b]pyridine-based coumarin chromophore (PPC-O). Given the desulfurization reaction with Hg2+, AIE inactive PPC-S can be transformed into PPC-O with AIE activity, which can be employed for the fluorescence turn-on detection of Hg2+ with satisfactory selectivity and sensitivity in aqueous solutions.  相似文献   

13.
Li J  Li L  Zheng L  Xian Y  Jin L 《Talanta》2006,68(3):765-770
A COD measurement by a photocatalytic oxidation method using nano-TiO2 film was investigated. K2Cr2O7 was added into the solution to enhance the efficiency of photocatalytic degradation, and simultaneously K2Cr2O7 was reduced to Cr(III) by photogenerated electrons, which were adsorbed on the surface of TiO2. The measuring principle was based on direct determination of Cr(III) concentration which was proportional to the COD value. Under the optimized experiment condition, the application range was 20-500 mg l−1, and the detection limit was 20 mg l−1. The immobilization of photocatalyst on the supports could not only solve the problem of low recovery of the catalyst and hard separation from the solution, but also overcome its shortcoming of poor stability. Applied this method to the determination of real samples, it was found to be rapid and environmentally friendly. Additionally, the method proposed above for determination of COD was in excellent correspondence with values obtained by using the conventional method.  相似文献   

14.
Gao N  Li L  Shi Z  Zhang X  Jin W 《Electrophoresis》2007,28(21):3966-3975
A novel high-throughput method is presented based on fluorescence images of cells in a microchannel for determination of glutathione (GSH) and reactive oxygen species (ROS) inside single cells. We first present a method to determine GSH and ROS separately, in which GSH in cells is derivatized by 2,3-naphthalenedicarboxaldehyde (NDA), and intracellular ROS is labeled using dihydrorhodamine 123. The cells with either fluorescent derivatized GSH or fluorescent labeled ROS are introduced into a microchannel and fluorescence images of every moving cell in the microchannel are taken continuously using a highly sensitive thermoelectrically cooled electron-multiplying CCD. The fluorescence intensities of the images correspond to the masses of GSH or ROS. An average detection rate of 80-120 cells/min is achieved. We then propose a method for simultaneously determining GSH and ROS, in which ROS is first labeled in the cells. The labeled cells are then introduced into the whole channel and allowed to immobilize onto the glass substrate. The fluorescence images of all the cells in the channel are taken. NDA is then introduced into the channel to derivatize the GSH in the immobilized cells, and fluorescence images of all cells are taken again. An average analysis rate of 20 cells/min is achieved. The masses of GSH and ROS in the single cells can be obtained from the fluorescence intensities of the images using their calibration curves. Since the cells are not lysed, there is no problem with adsorption of biological macromolecules and cellular debris on the channel wall, so that channel treatment, necessary in usual single-cell analysis techniques using CE and microchip electrophoresis, is no longer necessary. For single global cells, this method can also be used to determine the concentrations of ROS and GSH, which has not been reported previously. The concentrations of ROS and GSH in single global cells can be calculated from the determined masses and the cell volume (derived from the diameter of the round fluorescence image of the derivatized GSH). For gastric cancer cells, the concentrations of GSH and ROS are in the range 0.35x10(-3)-1.3x10(-3) mol/L and 0.77x10(-) (6)-1.5x10(-6) mol/L, respectively.  相似文献   

15.
Amao Y  Komori T 《Talanta》2005,66(4):976-981
An optical CO2 sensor based on the overlay of the CO2 induced absorbance change of pH indicator dye α-naphtholphthalein in poly(isobutyl methacrylate) (polyIBM) layer with the fluorescence of tetraphenylporphyrin (TPP) in polystyrene layer is developed. The observed luminescence intensity from TPP at 655 nm increased with increasing the CO2 concentration. The ratio I100/I0 value of the sensing film consisting of α-naphtholphthalein in polyIBM and TPP in polystyrene layer, where I0 and I100 represent the detected luminescence intensities from a layer exposed to argon and CO2 saturated conditions, respectively, that the sensitivity of the sensor, is estimated to be 192. The response and recovery times of the sensing film are less than 6.0 s for switching from argon to CO2, and for switching from CO2 to argon. The signal changes are fully reversible and no hysterisis is observed during the measurements. The highly sensitive optical CO2 sensor based on fluorescence intensity changes of TPP due to the absorption change of α-naphtholphthalein in polyIBM layer with CO2 is achieved.  相似文献   

16.
Cobalt oxide sensing film was in situ prepared on glassy carbon electrode surface via constant potential oxidation. Controlling at 0.8 V in NaOH solution, the high-valence cobalt catalytically oxidized the reduced compounds, decreasing its surface amount and current signal. The current decline was used as the response signal of chemical oxygen demand (COD) because COD represents the summation of reduced compounds in water. The surface morphology and electrocatalytic activity of cobalt oxide were readily tuned by variation of deposition potential, time, medium and Co2+ concentration. As confirmed from the atomic force microscopy measurements, the cobalt oxide film, that prepared at 1.3 V for 40 s in pH 4.6 acetate buffer containing 10 mM Co(NO3)2, possesses large surface roughness and numerous three-dimensional structures. Electrochemical tests indicated that the prepared cobalt oxide exhibited high electrocatalytic activity to the reduced compounds, accompanied with strong COD signal enhancement. As a result, a novel electrochemical sensor with high sensitivity, rapid response and operational simplicity was developed for COD. The detection limit was as low as 1.1 mg L−1. The analytical application was studied using a large number of lake water samples, and the accuracy was tested by standard method.  相似文献   

17.
The electrocatalysis of nitrite in solutions at an inorganic film modified glassy carbon electrode was studied. The modifier was an electrodeposited thin inorganic film of the copper-heptacyanonitrosylferrate (CuHNF). Cyclic voltammetry of the modified electrode in a nitrite solution revealed that both oxidation and reduction of nitrite were catalyzed and the electrocatalytic currents were controlled by the diffusion of nitrite. Voltammetric and amperometric responses were investigated. When applied as an amperometric sensor in a flow injection system, the modified electrode permitted detection at — 0.55 V, over 500 mV lower than at the naked electrode surface. A linear response range extending from 1 × 10–6 to 1 × 10–3 M nitrite was obtained, with a detection limit of 3 × 10–7 M. The relative standard deviation for 50 repetitive injections with a 5 × 10–5 M nitrite solution was less than 4%. The procedure was applied to the determination of nitrite in saliva and nitrate.  相似文献   

18.
A simple and sensitive sensor is described for the determination of acetylspiramycin (ASPM) based on a single-wall carbon nanotubes (SWNTs)-dihexadecyl hydrogen phosphate (DHP) film coated glassy carbon electrode (GCE). Compared with a bare GCE, the SWNTs-DHP film modified GCE exhibits excellent enhancement effects on the electrochemical oxidation of ASPM. A well-defined oxidation peak of ASPM occurs at 0.89 V in 0.1 mol·L−1 phosphate buffer (pH 5.5), which was used to determine ASPM. The electrochemical behavior of ASPM at the SWNTs-DHP modified GCE was examined by cyclic voltammetry and differential pulse voltammetry. The experimental parameters were optimized and a direct electrochemical method for the determination of ASPM is proposed. Under optimum conditions, the oxidation peak current is linear to the concentration of ASPM in the range of 5.0–100 μg·mL−1, with a detection limit of 1 μg·mL−1. The SWNTs-DHP film modified electrode also provides an efficient way of eliminating interferences from some inorganic species in the solution. This sensor was successfully utilized to determine ASPM in drugs.  相似文献   

19.
A novel technique of covalent immobilization of indicator dyes in the preparation of fluorescence sensors is developed. Silver nanoparticles are used as bridges and carriers for anchoring indicator dyes. 3-amino-9-ethylcarbazole (AEC) was employed as an example of indicator dyes with terminal amino groups and covalently immobilized onto the outmost surface of a quartz glass slide. First, the glass slide was functionalized by (3-mercaptopropyl) trimethoxysilane (MPS) to form a thiol-terminated self-assembled monolayer, where silver nanoparticles were strongly bound to the surface through covalent bonding. Then, 16-mercaptohexadecanoic acid (MHDA) was self-assembled to bring carboxylic groups onto the surface of silver nanoparticles. A further activation by using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) converted the carboxylic groups into succinimide esters. Finally, the active succinimide esters on the surface of silver nanoparticles were reacted with AEC. Thus, AEC was covalently bound to the glass slide and an AEC-immobilized sensor was obtained. The sensor exhibited very satisfactory reproducibility and reversibility, rapid response and no dye-leaching. Rutin can quench the fluorescence intensity of the sensor and be measured by using the sensor. The linear response of the sensor to rutin covers the range from 2.0 × 10−6 to 1.5 × 10−4 mol L−1 with a detection limit of 8.0 × 10−7 mol L−1. The proposed technique may be feasible to the covalent immobilization of other dyes with primary amino groups.  相似文献   

20.
In this work we have proposed a method for the detection of alcohol vapours, i.e. methanol, ethanol and isopropanol, based on the optical sensing response of magnesium 5,10,15,20-tetraphenyl porphyrin (MgTPP) thin films, as measured by optical spectrometry with the assistance of chemometric analysis. We have implemented a scheme which allows a laboratory UV–vis spectrometer to act as a so-called “electronic nose” with very little modification. MgTPP thin films were prepared by a spin coating technique, using chloroform as the solvent, and then subjected to thermal annealing at 280 °C in an argon atmosphere. These MgTPP optical gas sensors presented significant responses with methanol compared to ethanol and isopropanol, based on the dynamic flow of alcohol vapours at the same mol% of alcohol concentration. Density functional theory (DFT) calculations were performed to model the underlying mechanism of this selectivity. The performance of the optical gas sensors was optimised by varying the fabrication parameters. It is hoped that the MgTPP thin film together with an off-the-shelf optical spectrometer and a simple chemometrics algorithm can be a valuable tool for the analysis of alcoholic content in the beverage industry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号