首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Cellular manipulation and fluorescent measurement were performed on two types of biological cells. First, transport and retention of yeast cells were demonstrated on a glass microfluidic chip, which consists of special U-shaped microstructures. These microstructures have the openings parallel to the liquid flow and weirs perpendicular to the flow. These allow the retention of yeast cells in the U-shaped pocket and drainage of liquid over the weirs. Thereafter, the same chip was used to carry out real-time fluorescent measurement for the cellular changes in single Jurkat T cells. In this case, the Jurkat cells were localized inside the straight portion of a microchannel. Fluorescent imaging on the same, single suspension cell was carried out to study two cellular processes occurring in viable cells, (1) the intracellular conversion of fluorescein diacetate (FDA) to fluorescein; (2) the degradation of an inhibitory protein, IkappaB, as involved in the NF-kappaB signalling pathway. In the former, the increase in fluorescent intensity of single Jurkat T cells (due to fluorescein formation) was measured; whereas in the latter, the decrease in the fluorescent intensity of a single transfected Jurkat cell (due to the degradation of the IkappaB-EGFP fusion protein) was monitored. In addition, we employed a Jurkat cell expressed with IkappaB-EGFP to probe any possible action of an herbal compound, isoliquiritigenin (IQ), on the degradation of IkappaB-EGFP. These examples have demonstrated that Jurkat cells remain viable within microfluidic channels for cellular studies and that the microfluidic chip can facilitate monitoring of cellular changes of biological cells at the single cell level and in the same cell.  相似文献   

2.
Here, we report a microfluidic same‐single‐cell analysis to study the inhibition of multidrug resistance due to drug efflux on single leukemic cells. Drug efflux inhibition was investigated in the microfluidic chip using two different fluorescence detection systems, namely, a compact single‐cell bioanalyzer and the conventional optical detection system constructed from an inverted microscope and a microphotometer. More importantly, a compact signal generator was used to conduct dielectrophoretic cell trapping together with the compact SCB. By using the DEP force, a single acute myeloid leukemia cell was trapped in the cell retention structure of the chip. This allowed us to detect dye accumulation in the MDR leukemic cells in the presence of cyclosporine A (CsA). CsA and rhodamine 123 were used as the P‐glycoprotein inhibitor and fluorescent dye, respectively. The result showed that the Rh123 fluorescence signal in a single‐cell increased dramatically over its same‐cell control on both fluorescence detection systems due to the inhibition by CsA.  相似文献   

3.
Wang X  Chen S  Kong M  Wang Z  Costa KD  Li RA  Sun D 《Lab on a chip》2011,11(21):3656-3662
Sorting (or isolation) and manipulation of rare cells with high recovery rate and purity are of critical importance to a wide range of physiological applications. In the current paper, we report on a generic single cell manipulation tool that integrates optical tweezers and microfluidic chip technologies for handling small cell population sorting with high accuracy. The laminar flow nature of microfluidics enables the targeted cells to be focused on a desired area for cell isolation. To recognize the target cells, we develop an image processing methodology with a recognition capability of multiple features, e.g., cell size and fluorescence label. The target cells can be moved precisely by optical tweezers to the desired destination in a noninvasive manner. The unique advantages of this sorter are its high recovery rate and purity in small cell population sorting. The design is based on dynamic fluid and dynamic light pattern, in which single as well as multiple laser traps are employed for cell transportation, and a recognition capability of multiple cell features. Experiments of sorting yeast cells and human embryonic stem cells are performed to demonstrate the effectiveness of the proposed cell sorting approach.  相似文献   

4.
We report a reliable strategy to perform automated image cytometry of single (non-adherent) stem cells captured in microfluidic traps. The method rapidly segments images of an entire microfluidic chip based on the detection of horizontal edges of microfluidic channels, from where the position of the trapped cells can be derived and the trapped cells identified with very high precision (>97%). We used this method to successfully quantify the efficiency and spatial distribution of single-cell loading of a microfluidic chip comprised of 2048 single-cell traps. Furthermore, cytometric analysis of trapped primary hematopoietic stem cells (HSC) faithfully recapitulated the distribution of cells in the G1 and S/G2-M phase of the cell cycle that was measured by flow cytometry. This approach should be applicable to automatically track single live cells in a wealth of microfluidic systems.  相似文献   

5.
High-density microfluidic arrays for cell cytotoxicity analysis   总被引:12,自引:0,他引:12  
In this paper, we report on the development of a multilayer elastomeric microfluidic array platform for the high-throughput cell cytotoxicity screening of mammalian cell lines. Microfluidic channels in the platform for cell seeding are orthogonal to channels for toxin exposure, and within each channel intersection is a circular chamber with cell-trapping sieves. Integrated, pneumatically-actuated elastomeric valves within the device isolate the microchannel array within the device into parallel rows and columns for cell seeding and toxin exposure. As a demonstration of the multiplexing capability of the platform, a microfluidic array containing 576 chambers was used to screen three cell types (BALB/3T3, HeLa, and bovine endothelial cells) against a panel of five toxins (digitonin, saponin, CoCl(2), NiCl(2), acrolein). Evaluation of on-chip cell morphology and viability was carried out using fluorescence microscopy, with outcomes comparable to microtiter plate cytotoxicity assays. Using this scalable platform, cell seeding and toxin exposure can be carried out within a single microfluidic device in a multiplexed format, enabling high-density parallel cytotoxicity screening while minimizing reagent consumption.  相似文献   

6.
The size of a cell is a fundamental physiological property and is closely regulated by various environmental and genetic factors. Optical or confocal microscopy can be used to measure the dimensions of adherent cells, and Coulter counter or flow cytometry (forward scattering light intensity) can be used to estimate the volume of single cells in a flow. Although these methods could be used to obtain the mass of single live cells, no method suitable for directly measuring the mass of single adherent cells without detaching them from the surface is currently available. We report the design, fabrication, and testing of 'living cantilever arrays', an approach to measure the mass of single adherent live cells in fluid using silicon cantilever mass sensor. HeLa cells were injected into microfluidic channels with a linear array of functionalized silicon cantilevers and the cells were subsequently captured on the cantilevers with positive dielectrophoresis. The captured cells were then cultured on the cantilevers in a microfluidic environment and the resonant frequencies of the cantilevers were measured. The mass of a single HeLa cell was extracted from the resonance frequency shift of the cantilever and was found to be close to the mass value calculated from the cell density from the literature and the cell volume obtained from confocal microscopy. This approach can provide a new method for mass measurement of a single adherent cell in its physiological condition in a non-invasive manner, as well as optical observations of the same cell. We believe this technology would be very valuable for single cell time-course studies of adherent live cells.  相似文献   

7.
Optical gradient forces generated by fast steerable optical tweezers are highly effective for sorting small populations of cells in a lab-on-a-chip environment. The presented system can sort a broad range of different biological specimens by an automated optimisation of the tweezer path and velocity profile. The optimal grab positions for subsequent trap and cell displacements are estimated from the intensity of the bright field image, which is derived theoretically and proven experimentally. We exhibit rapid displacements of 2 μm small mitochondria, yeast cells, rod-shaped bacteria and 30 μm large protoplasts. Reliable sorting of yeast cells in a microfluidic chamber by both morphological criteria and by fluorescence emission is demonstrated.  相似文献   

8.
9.
Ho CT  Lin RZ  Chang WY  Chang HY  Liu CH 《Lab on a chip》2006,6(6):724-734
Biomimetic heterogeneous patterning of hepatic and endothelial cells, which start from randomly distributed cells inside the microfluidic chamber, via the chip design of enhanced field-induced dielectrophoresis (DEP) trap is demonstrated and reported in this paper. The concentric-stellate-tip electrode array design in this chip generates radial-pattern electric fields for the DEP manipulation of the live liver cells. By constructing the geometric shape and the distribution of stellate tips, the DEP electrodes enhance the desired spatial electric-field gradients to guide and snare individual cells to form the desired biomimetic pattern. With this proposed microfluidic chip design, the original randomly distributed hepatocytes inside the microfluidic chamber can be manipulated in parallel and align into the desired pearl-chain array pattern. This radial pattern mimics the lobular morphology of real liver tissue. The endothelial cells, then, are snared into the additional pearl-chain array and settle at the space in-between the previous hepatic pearl-chain array. By this cell-lab chip, we demonstrate the in vitro reconstruction of the heterogeneous lobule-mimetic radial pattern with good cell viability after cell patterning. This work reports the rapid in-parallel patterning of the dual types of live liver cells via the enhanced DEP trap inside the microfluidic chip.  相似文献   

10.
Bacterial counts provide important information during the processes such as pathogen detection and hygiene inspection and these processes are critical for public health and food/pharmaceutical production. In this study, we demonstrate the quantification of the number of bacterial cells based on the autofluorescence from the cell lysate on a microfluidic chip. We tested three model pathogenic bacteria (Listeria monocytogenes F4244, Salmonella Enteritidis PT1 and Escherichia coli O157:H7 EDL 933). In the experiment, a plug of approximately 150 pL containing lysate from 240 to 4100 cells was injected into a microfluidic channel with downstream laser-induced fluorescence detection under electrophoresis conditions. We found that the autofluorescence intensity increased with the number of cells almost linearly for all three bacteria. The autofluorescence remained a single peak when the cell lysate contained a mixture of different bacterial species. We also demonstrate a simple microfluidic device that integrates entrapment and electrical lysis of bacterial cells with fluorescence detection. Such a device can carry out the quantification of bacterial cells based on lysate autofluorescence without off-chip procedures. This study offers a simple and fast solution to on-chip quantification of bacterial cells without labeling. We believe that the method can be extended to other bacterial species.  相似文献   

11.
The integration of complete analyses systems "on chip" is one of the great potentials of microfabricated devices. In this study we present a new pressure-driven microfabricated fluorescent-activated cell sorter chip with advanced functional integration. Using this sorter, fluorescent latex beads are sorted from chicken red blood cells, achieving substantial enrichments at a sample throughput of 12000 cells s(-1). As a part of the sorter chip, we have developed a monolithically integrated single step coaxial flow compound for hydrodynamic focusing of samples in flow cytometry and cell sorting. The structure is simple, and can easily be microfabricated and integrated with other microfluidic components. We have designed an integrated chamber on the chip for holding and culturing of the sorted cells. By integrating this chamber, the risk of losing cells during cell handling processes is eliminated. Furthermore, we have also developed integrated optics for cell detection. Our new design contributes to the ongoing efforts for building a fully integrated micro cell sorting and analysing system.  相似文献   

12.
Fluorescent sensor array in a microfluidic chip   总被引:1,自引:0,他引:1  
Miniaturization and automation are highly important issues for the development of high-throughput processes. The area of micro total analysis systems (muTAS) is growing rapidly and the design of new schemes which are suitable for miniaturized analytical devices is of great importance. In this paper we report the immobilization of self-assembled monolayers (SAMs) with metal ion sensing properties, on the walls of glass microchannels. The parallel combinatorial synthesis of sensing SAMs in individually addressable microchannels towards the generation of optical sensor arrays and sensing chips has been developed. [figure: see text] The advantages of microfluidic devices, surface chemistry, parallel synthesis, and combinatorial approaches have been merged to integrate a fluorescent chemical sensor array in a microfluidic chip. Specifically, five different fluorescent self-assembled monolayers have been created on the internal walls of glass microchannels confined in a microfluidic chip.  相似文献   

13.
A bilayer microfluidic chip is used, in which multiple laminar streams are generated to define local microenvironments. The bilayer architecture of the microchip separates cell handling and positioning from cell activation by soluble chemicals. Cell activation is diffusion controlled through a porous membrane. By employing time-lapse fluorescence microscopy, gene expression of the enhanced green fluorescent protein (eGFP) in Saccharomyces cerevisiae is studied under various conditions. We demonstrate that the yeast cells remain viable in the microchip for at least 17h, and that gene expression can be initiated by the supply of the inducer galactose at a spatial precision of a few micrometers.  相似文献   

14.
Dielectrophoresis (DEP) and flow cytometry are powerful technologies and widely applied in microfluidic systems for handling and measuring cells and particles. Here, we present a novel microchip with a DEP selective filter integrated with two microchip flow cytometers (FCs) for on-line monitoring of cell sorting processes. On the microchip, the DEP filter is integrated in a microfluidic channel network to sort yeast cells by positive DEP. The two FCs detection windows are set upstream and downstream of the DEP filter. When a cell passes through the detection windows, the light scattered by the cell is measured by integrated polymer optical elements (waveguide, lens, and fiber coupler). By comparing the cell counting rates measured by the two FCs, the collection efficiency of the DEP filter can be determined. The chips were used for quantitative determination of the effect of flow rate, applied voltage, conductivity of the sample, and frequency of the electric field on the sorting efficiency. A theoretical model for the capture efficiency was developed and a reasonable agreement with the experimental results observed. Viable and non-viable yeast cells showed different frequency dependencies and were sorted with high efficiency. At 2 MHz, more than 90% of the viable and less than 10% of the non-viable cells were captured on the DEP filter. The presented approach provides quantitative real-time data for sorting a large number of cells and will allow optimization of the conditions for, e.g., collecting cancer cells on a DEP filter while normal cells pass through the system. Furthermore, the microstructure is simple to fabricate and can easily be integrated with other microstructures for lab-on-a-chip applications.  相似文献   

15.
Dimov IK  Kijanka G  Park Y  Ducrée J  Kang T  Lee LP 《Lab on a chip》2011,11(16):2701-2710
Just as the Petri dish has been invaluable to the evolution of biomedical science in the last 100 years, microfluidic cell assay platforms have the potential to change significantly the way modern biology and clinical science are performed. However, an evolutionary process of creating an efficient microfluidic array for many different bioassays is necessary. Specifically for a complete view of a cell response it is essential to incorporate cytotoxic, protein and gene analysis on a single system. Here we present a novel cellular and molecular analysis platform, which allows access to gene expression, protein immunoassay, and cytotoxicity information in parallel. It is realized by an integrated microfluidic array plate (iMAP). The iMAP enables sample processing of cells, perfusion based cell culture, effective perturbation of biologic molecules or drugs, and simultaneous, real-time optical analysis for different bioassays. The key features of the iMAP design are the interface of on-board gravity driven flow, the open access input fluid exchange and the highly efficient sedimentation based cell capture mechanism (~100% capture rates). The operation of the device is straightforward (tube and pump free) and capable of handling dilute samples (5-cells per experiment), low reagent volumes (50 nL per reaction), and performing single cell protein and gene expression measurements. We believe that the unique low cell number and triple analysis capabilities of the iMAP platform can enable novel dynamic studies of scarce cells.  相似文献   

16.
Sorting and recovering specific live cells from samples containing less than a few thousand cells have become major hurdles in rare cell exploration such as stem cell research, cell therapy and cell based diagnostics. We describe here a new technology based on a microelectronic chip integrating an array of over 100,000 independent electrodes and sensors which allow individual and parallel single cell manipulation of up to 10,000 cells while maintaining viability and proliferation capabilities. Manipulation is carried out using dynamic dielectrophoretic traps controlled by an electronic interface. We also demonstrate the capabilities of the chip by sorting and recovering individual live fluorescent cells from an unlabeled population.  相似文献   

17.
Park S  Kim D  Mitchell RJ  Kim T 《Lab on a chip》2011,11(17):2916-2923
We present a microfabricated concentrator array device that makes it possible to quantify the predation rate of Bdellovibrio bacteriovorus, a predatory microbe, toward its prey, Escherichia coli str. MG1655. The device can accumulate both prey and predator microbes sequentially within a series of concentrator arrays using the motility of the microbes and microfabricated arrowhead-shaped ratchet structures. Since the device can constrain both prey and predator cells within 200 pL chambers at a desired range of cell densities, it was demonstrated that the device cannot only enhance the possibility of studying predation processes/cycles directly at a single cell level but can also quantify the predation rates indirectly by measuring the time-dependent fluorescent intensity signals from the prey. Furthermore, the device can produce a wide range of initial prey to predator density ratios within various concentrator arrays through the use of microfluidic mixer structures on a single array chip, which allows us to study many different conditions with a single set of cultures, and quantitatively characterize the predation behaviour/rate. Lastly, we note that this novel concentrator array device can be a very powerful tool facilitating studies of microbial predations and microbe-microbe interaction and may be broadly used in other microbial biotechnological applications.  相似文献   

18.
The use of probe beads for lab-on-chip affinity assays is very interesting from a practical point of view. It is easier to handle and trap beads than molecules in microfluidic systems. We present a method for the immobilization of probe beads at defined areas on a chip using dielectrophoresis (DEP)-controlled adhesion. The method is fast, i.e., it takes between 10 and 120 s--depending on the protocol--to functionalize a chip surface at defined areas. The method is versatile, i.e., it works for beads with different types of probe molecule coatings. The immobilization is irreversible, i.e., the retained beads are able to withstand high flow velocities in a flow-through device even after the DEP voltage is turned off, thus allowing the use of conventional high-conductivity analyte buffers in the following assay procedure. We demonstrate the on-chip immobilization of fluorescent beads coated with biotin, protein A, and goat-antimouse immunoglobulin G (IgG). The number of immobilized beads at an electrode array can be determined from their fluorescence signal. Further, we use this method to demonstrate the detection of streptavidin and mouse IgG. Finally, we demonstrate the feasibility of the parallel detection of different analyte molecules on the same chip.  相似文献   

19.
We present a microfluidic cell-culture chip that enables trapping, cultivation and release of selected individual cells. The chip is fabricated by a simple hybrid glass-SU-8-PDMS approach, which produces a completely transparent microfluidic system amenable to optical inspection. Single cells are trapped in a microfluidic channel using mild suction at defined cell immobilization orifices, where they are cultivated under controlled environmental conditions. Cells of interest can be individually and independently released for further downstream analysis by applying a negative dielectrophoretic force via the respective electrodes located at each immobilization site. The combination of hydrodynamic cell-trapping and dielectrophoretic methods for cell releasing enables highly versatile single-cell manipulation in an array-based format. Computational fluid dynamics simulations were performed to estimate the properties of the system during cell trapping and releasing. Polystyrene beads and yeast cells have been used to investigate and characterize the different functions and to demonstrate biological compatibility and viability of the platform for single-cell applications in research areas such as systems biology.  相似文献   

20.
Due to the heterogeneous and variable drug sensitivity of tumor cells, real-time monitoring of a patient''s drug response is desirable for implementing personalized and dynamic therapy. Although considerable efforts have been directed at drug screening in living cells, performing repeated drug sensitivity analysis using patient-derived primary tumor cells at the single-cell level remains challenging. Here, we present an efficient approach to assess phenotype-related drug sensitivity at the single-cell level using patient-derived circulating tumor cells (CTCs) based on a drug sensitivity microfluidic chip (DS-Chip). The DS-Chip consists of a drug gradient generator and parallel cell traps, achieving continuous single CTC capture, drug gradient distributions, drug stimulation, fluorescent probe labeling and three-color fluorescence imaging. Based on the established DS-Chip, we investigated the drug sensitivity of single cells by simultaneously monitoring epithelial–mesenchymal transition (EMT) biomarkers and apoptosis in living cells, and verified the correlation between EMT gradients and drug sensitivity. Using the new approach, we further tested the optimal drug response dose in individual CTCs isolated from 5 cancer patients through fluorescence analysis of EMT and apoptosis. The DS-Chip allows noninvasive and real-time measurements of the drug sensitivity of a patient''s tumor cells during therapy. This developed approach has practical significance and can effectively guide drug selection and therapeutic evaluation for personalized medicine.

Due to the heterogeneous and variable drug sensitivity of tumor cells, real-time monitoring of a patient''s drug response is desirable for implementing personalized and dynamic therapy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号