首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A micro-solid phase extraction technique was developed using a novel polypyrrole-polyamide nanofiber sheet, fabricated by electrospinning method. The applicability of the new nanofiber sheet was examined as an extracting medium to isolate malathion as a model pesticide from aqueous samples. Solvent desorption was subsequently performed in a microvial, and an aliquot of extractant was injected into gas chromatography–mass spectrometry. Various parameters affecting the electrospinning process including monomer concentration, polyamide content, applied voltage, and electrospinning time were examined. After fabricating the most suitable preparation conditions, influential parameters on the extraction and desorption processes were optimized. The developed method proved to be rather convenient and offers sufficient sensitivity and good reproducibility. The limit of detection (S/N = 3) and limit of quantification (S/N = 10) of the method under optimized conditions were 50 and 100 ng L−1, respectively. The relative standard deviation at concentration level of 1 ng mL−1 was 2% (n = 3). The calibration curve of analyte showed linearity in the range of 0.1–1 ng mL−1 (R 2 = 0.9975). The developed method was successfully applied to tap and Zayanderood river water samples, while the relative recovery percentages of 98% and 96% were obtained, respectively. The whole procedure showed to be conveniently applicable and quite easy to be manipulated.  相似文献   

2.
This paper describes the novel preparation of three kinds of nanofibers [poly(styrene-co-methacrylic acid), poly(styrene-co-p-styrene sulfonate), polystyrene] investigated as solid-phase extraction (SPE) sorbents to extract six compounds (nitrobenzene, 2-naphthol, benzene, n-butyl p-hydroxybenzoate, naphthalene, p-dichlorobenzene) in environmental water by high-performance liquid chromatography. Parameters affecting extraction efficiency were investigated in detail to explore the extraction mechanism of the nanofibers. Under optimized conditions, six compounds followed an excellent linear relationship in the range 10–5,000 ng mL−1 with coefficients of determination (r 2) greater than 0.99. The repeatability (expressed as relative standard deviations) was from 3.0 to 7.0%, corresponding to 2.0 mL of water samples at 25 and 500 ng mL−1 spiked levels for the six compounds. The limits of detection varied from 0.01 to 0.15 ng mL−1 (signal-to-noise ratio of3). A comparison of the SPE using nanofibers as sorbents and the most commonly used octadecylsilica SPE cartridges was carried out in terms of absolute recovery, sensitivity, and reproducibility for the compounds investigated. Finally, the method was applied to four real water samples. The results highlighted the importance of functional groups, and the polarity of nanofibers in controlling sorption of target compounds, and clearly showed that the new method could be a viable and environmentally friendly technique for analyzing pollutants in environmental samples.  相似文献   

3.
槲皮素分子印迹聚合物的制备及固相萃取性能研究   总被引:13,自引:0,他引:13  
采用分子印迹技术, 以槲皮素为模板分子, 丙烯酰胺为功能单体, 乙二醇二甲基丙烯酸脂为交联剂, 通过热引发聚合, 制备了槲皮素分子印迹聚合物, 并通过装入固相萃取柱试验了聚合物对槲皮素的选择性能. 结果表明, 该分子印迹聚合物对槲皮素具有高度选择性, 为从天然产物中高效分离富集黄酮活性成分槲皮素提供了一种新材料.  相似文献   

4.
A novel on-line flow injection solid phase extraction method for the preconcentration of trace toxic metals prior determination by flame atomic absorption spectrometry (FI-SPE-FAAS) was developed. The potential application of the hydrophobic reversed phase co-polymer sorbent StrataTM-X packed into an on-line microcolumn for the quantification of Cd(II), Pb(II), Cu(II) and Cr(VI) was demonstrated for the first time. The method was based on the on-line formation of metal complexes using sodium diethyl-dithiocarbamate (DDTC) and on the subsequent retention of them onto the sorbent material. The target analytes were completely eluted by methanol and, subsequently, directed to FAAS for quantification. All chemical and flow variables affecting the performance of the developed method were thoroughly studied and optimised. For a preconcentration time of 90 s and a sampling frequency of 28 h?1, enhancement factors of 72, 140, 185, 63 and detection limits of 0.18, 1.6, 0.20 and 1.2 μg L ?1 were obtained for Cd(II), Pb(II), Cu(II) and Cr(VI), respectively. The accuracy of the FI-SPE-FAAS method was evaluated by analysing certified reference materials as well as spiked environmental water samples. Furthermore, a comparative study of the analytical characteristics, the properties as well as the chemical structures of commercial polymeric based sorbent materials was employed. Strata-X sorbent was compared against HypersepTM SCX, Bond Elut® PlexaTM PCX, Oasis-HLBTM and NobiasTM PA-1, regarding the adaptation in on-line FI-SPE-FAAS systems for metal determination, and herein presented.  相似文献   

5.
Microchimica Acta - The authors describe a dual-use sorbent for solid phase extraction (SPE) in combination with surface-enhanced Raman spectroscopy (SERS). The sorbent consists of calcium...  相似文献   

6.
Journal of Solid State Electrochemistry - All-solid-state batteries represent the next generation of electrochemical energy storage systems. A tin-carbon nanocomposite material is prepared by the...  相似文献   

7.
The adsorption behavior of multiwalled carbon nanotubes (MWNTs) toward copper has been investigated systemically, and a new method has been developed for the determination of trace copper in water samples based on preconcentration with a microcolumn packed with MWNTs prior to its determination by flame atomic absorption spectrometry. The optimum experimental parameters for preconcentration of copper, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been investigated. Copper can be quantitatively retained by MWNTs in the pH range 5-8, and then eluted completely with 0.5 M HNO3. The detection limit of this method for Cu was 0.42 ng/mL, and the RSD was 3.5% at the 10 ng/mL Cu level. The method was validated using a certified reference material, and has been successfully applied for the determination of trace copper in water samples.  相似文献   

8.
The potential of carbon nanocones/disks as sorbent material in solid-phase extraction (SPE) procedures has been evaluated. For this aim, a model analytical problem, the determination of chlorophenols in water samples, was selected. An accurately weighed amount of 20 mg of purified carbon nanocones/disks was packed in 3 mL commercial SPE cartridges. Once conditioned, up to 8 mL of water samples can be preconcentrated without analyte losses. The chlorophenols were eluted by using 200 μL of hexane. Aliquots of 2 μL of the organic extract were injected in the gas chromatograph–mass spectrometer for separation and quantification. The purification of the commercial nanocones/disks to reduce the presence of amorphous carbon has been successfully achieved by heating the carbon nanocones/disks at 450 °C for 20 min. Detection limits of chlorophenols were in the range 0.3–8 ng mL−1 by using 2 mL of sample. Moreover, excellent average recovery values (98.8–100.9%) have been obtained after the analysis of water samples from different nature. Finally, the performance of the carbon nanocones/disks as sorbent material has been compared with that of multiwalled carbon nanotubes, providing the former better results under the experimental conditions assayed.  相似文献   

9.
β-Cyclodextrin-polyurethane (β-CDPU) polymer was synthesized by the reaction of β-cyclodextrin with hexamethylene diisocyanate in dry dimethylformamide and used as a sorbent for the solid phase extraction (SPE) of carcinogenic aromatic amines from water. The polymers were characterized by Fourier transform infrared spectroscopy, thermogravimetric analysis, differential scanning calorimetry and particle size analysis. The separation and quantification was performed by Liquid chromatography with RP-C18 column and diode array detection using standard arylamines for quantification. When compared with commercially available sorbents, β-CDPU gave better recovery for the aromatic amines. From the variation of pH of the extractant from 4.0 to 8.5 recovery was highest at pH 8.5. The breakthrough volume has been ascertained to be 100 ml for 200 mg of the resin. The new SPE material offers better recovery and estimation of banned arylamines.  相似文献   

10.
Polychlorotrifluoroethylene (PCTFE) in the form of beads was applied, as packing material for flow injection on-line column preconcentration and separation systems coupled with flame atomic absorption spectrometry (FAAS). Its performance characteristics were evaluated for trace copper determination in environmental samples. The on-line formed complex of metal with diethyldithiophosphate (DDPA) was sorbed on the PCTFE surface. Isobutyl methyl ketone (IBMK) at a flow rate of 2.8 mL min−1 was used to elute the analyte complex directly into the nebulizer-burner system of spectrophotometer. The proposed sorbent material reveal, excellent chemical and mechanical resistance, fast adsorption kinetics permitting the use of high sample flow rates up to 15 mL min−1 without loss of retention efficiency. For copper determination, with 90 s preconcentration time the sample frequency was 30 h−1, the enhancement factor was 250, which could be further improved by increasing the loading (preconcentration) time. The detection limit (3s) was cL = 0.07 μg L−1, and the precision (R.S.D.) was 1.8%, at the 2.0 μg L−1 Cu(II) level. For lead determination, the detection limit was cL = 2.7 μg L−1, and the precision (R.S.D.) 2.2%, at the 40.0 μg L−1 Pb(II) level. The accuracy of the developed method was evaluated by analyzing certified reference materials and by recovery measurements on spiked natural water samples.  相似文献   

11.
12.
Summary A novel approach to solid phase extraction, based on the use of a highly selective molecularly imprinted polymer, is presented. The versatility of this type of sorbent for solid phase extraction was demonstrated in a model batch-wise pre-concentration of sameridine prior to gas chromatography. Problems associated with leakage of remaining imprint molecules during the desorption phase could be eliminated by the use of a close structural analogue of sameridine as the imprint species. It was found that a major benefit of the imprinted polymer was its specificity, which lead to distinctly cleaner chromatographic traces and ability to improve sensitivity by extracting sameridine from larger sample volumes.  相似文献   

13.
The aim of this work is to develop a simple phase‐transfer method for dispersive liquid–liquid microextraction. For this purpose, a polystyrene nanofiber was prepared by a facile electrospinning strategy and used for the first time as an adsorbent to transfer the organic phase in dispersive liquid–liquid microextraction procedure. The fiber was characterized and its chemical stability and excellent hydrophobicity enable it to selectively adsorb the organic solvent in an aqueous sample. High porosity and specific surface area provide a large adsorption capacity. Under the optimal conditions, the developed dispersive liquid–liquid microextraction with high‐performance liquid chromatography method was successfully applied to the analysis of aldehydes in environmental water samples. The merits of this approach are that it is easy‐to‐operate, low‐cost, time‐saving, and has satisfactory sensitivity. It provides an alternative way for fast and convenient phase transfer of the hydrophobic organic solvent from the aqueous phase.  相似文献   

14.
Nazari  Saeid  Mehri  Ashraf  Hassannia  Asma Sepehri 《Mikrochimica acta》2017,184(9):3239-3246
Microchimica Acta - A combination of magnetic solid phase extraction (MSPE) and dispersive liquid phase microextraction (DLPME) was applied in a new method for preconcentration and extremely...  相似文献   

15.
Many plants have a high polyphenol content, which causes the matrix effect and makes the analysis of trace pesticide residues highly challenging. A common approach to improving matrix effects is to purify pesticides through the use of sorbents, but this requires a combination of multiple sorbents and extensive use. Zeolitic imidazolate framework-8 is widely used for pesticide analysis due to its high porosity, large specific surface area, and versatility. Here, we established and validated a modified quick, easy, cheap, effective, rugged, and safe method based on a zeolitic imidazolate framework-8 that was used to test the removal ability for polyphenols. To this end, 145 pesticide residues in peppermint, perilla, fennel, and mulberry leaves were analyzed by the modified method coupled with liquid chromatography with tandem mass spectrometry. The mean recoveries of all pesticide residues were in the range of 74.3–103.7%, with mean relative standard deviations ≤9.1% at spiked concentrations of 1, 10, 50, and 100 μg/kg for mulberry leaves. The limits of quantitation of the method ranged from 1 to 50 μg/kg. This study offers a reliable approach for the accurate quantitative analysis of various trace substances in the polyphenol-rich plants.  相似文献   

16.
研究了多壁碳纳米管(MWNT)作为固相萃取柱填料对芳香有机化合物的吸附性能,并探讨了吸附作用的本质。采用MWNT分别萃取了不同结构的物质,实验结果表明,MWNT对芳香有机化合物有较强的吸附作用,这种作用主要是由于MWNT表面的离域大π键和芳香环的共轭π键相互作用的结果,而碳纳米管的高比表面积产生的物理吸附作用相对要小得多。  相似文献   

17.
林舒婷  丁青青  张文敏  张兰  卢巧梅 《色谱》2021,39(12):1281-1290
植物激素在植物生长过程中具有重要作用,调节植物生长、发育及抗逆的各个过程。植物激素超微精准定量分析一直是植物生理学研究的瓶颈问题。植物激素的准确、高效检测目前大多是基于液相色谱-串联质谱联用技术。样品前处理是植物激素色谱-质谱分析中必不可少的一个步骤,直接影响后续检测方法的灵敏度和准确性。在植物激素各种前处理方法中,固相萃取(SPE)技术应用非常广泛。在萃取小柱基础上发展了多种新形式(分散固相萃取、磁性固相萃取、固相微萃取等,称之为SPE相关方法)。在上述SPE相关方法中,吸附材料的选择均是关键因素,决定了样品前处理过程的目标物提取、净化和富集效果。碳基材料(包括碳纳米管、石墨烯、碳氮化合物等)和有机骨架材料(包括金属有机骨架、共价有机材料)拥有结构可设计、比表面积大、稳定性良好等特性,非常适合作为吸附材料。分子印迹聚合物和超分子化合物依靠主-客体特异性分子识别作用,能显著提高样品前处理方法的选择性。本文重点针对植物激素样品前处理中的SPE技术,综述了近5年来上述几类功能化吸附材料的最新应用进展,并对其发展趋势进行展望。  相似文献   

18.
A novel and very simple microextraction approach for pre-concentration and direct solid phase spectrophotometric measurement has been developed for the determination of chromogenic analytes. The model analyte to assess this approach was the chromophore malachite green (MG). The analyte was extracted from water samples onto a small rotating disk made of Teflon containing a sorbent phase of polydimethylsiloxane (PDMS) on one of its surfaces. We refer to the extraction procedure as rotating disk sorptive extraction (RDSE). After extraction, the sorbent phase with the concentrated analyte was separated from the Teflon disk and used directly for MG determination by solid phase spectrophotometry at 624 nm, without the necessity of a desorption step. Chemical and extraction variables such as concentration of sodium sulfate, pH, disk rotational velocity, extraction time, and temperature were studied in order to establish the best conditions for extraction. Under optimum conditions, the extraction of MG was carried out in 18 min and 90 min, for sample volumes of 100mL or 1000 mL, respectively. The detection limit, based on three times the standard deviation of the blank phase (3σ(b)), was 1.4 μg L?1 and the repeatability, expressed as relative standard deviation (RSD), for 20 μg L?1 MG was 8.1%. This study also applied the method to real samples, obtaining quantitative recovery (mean recovery of 99.3%). The PDMS phases could be reused after desorbing the MG into methanol for 3h. Replacement of the PDMS film onto the disk is very easy and low cost.  相似文献   

19.
The potential of carbon nanotubes for the solid phase extraction of parabens in cosmetic products and the detection using a corona-charged aerosol detector (C-CAD) is presented in this work. The analytical procedure is based on a conventional solid phase extraction step for which 20 mg of multi-walled carbon nanotubes were packed in a 3-mL commercial SPE cartridge. Methylparaben, ethylparaben, propylparaben and butylparaben were thus isolated and preconcentrated from the pre-treated samples and subsequently separated on a RP-C18 column using acetonitrile:water, 50:50 (v/v) as mobile phase. The analytical signals for the individual parabens were obtained using C-CAD. The experimental variables affecting the extraction procedure and the instrumental detection have been deeply studied. Limits of detection were in the range of 0.5–2.1 mg L−1, while the linear range was extended up to 400 mg L−1. The average precision of the method varied between 3.3–3.8% (repeatability) and 4.3–7.6% (reproducibility). Finally, the optimized procedure was applied to the determination of the target preservatives in a variety of cosmetic products with satisfactory results.  相似文献   

20.
Kang X  Pan C  Xu Q  Yao Y  Wang Y  Qi D  Gu Z 《Analytica chimica acta》2007,587(1):75-81
A novel micro-extraction procedure was developed through the use of an electrospun polymer nanofiber as a solid-phase extraction (SPE) sorbent to directly extract trazodone from human plasma. The target compound was then monitored by a high performance liquid chromatography with ultraviolet detector (HPLC-UV) system. Parameters of influencing the extraction efficiency, such as fiber diameter, fiber packing amount, eluted solvent, pH and ionic strength were investigated. Under the optimized conditions, a linear response for trazodone over the range of 20-2000 ng mL−1 was achieved with a γ2 value of 0.9996. The precision of the method was examined with relative standard deviations of 5.7, 2.7, 2.2% corresponding to 50, 200, and 500 ng mL−1, respectively, of trazodone spiked into 0.1 mL of plasma samples. The extraction recoveries of 58.3-75.2% and the relative recoveries of 94.6-105.5% were obtained. The limit of detection (LOD) was determined to be 8 ng mL−1. A 15 min of HPLC gradient was successfully applied to determine trazodone from human plasma. Due to its simplicity, selectivity and sensitivity, the method may be applied to pharmacokinetic and pharmacodynamic studies of drugs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号