首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Zirconium(IV) phosphosulphosalicylate, a cation exchanger was synthesized by mixing zirconium oxychloride to a mixture of 5-sulphosalicylic acid and phosphoric acid. The material showed good efficiency for the preparation of an ion-selective membrane electrode. The membrane was characterized affinity for Pb(II) ions. Due to its Pb(II) selective nature, the ion-exchanger was used as an electroactive by XRD and SEM analysis. The electrode responds to Pb(II) ions in a linear range from 1 × 10−5 to 1 × 10−1 M with a slope of 43.8 mV per decade change in concentration with detection limit of 4.78 × 10−6 M. The life span of electrode was found to be 90 days. The proposed electrode showed satisfactory performance over a pH range of 4.0–6.5, with a fast response time of 15 s. The sensor has been applied to the determination of Pb(II) ions in water samples of different origins. It has also been used as indicator electrode in potentiometric titration of Pb(II) ion with EDTA.  相似文献   

2.
Chromium(III) ion selective electrode based on glyoxal bis(2-hydroxyanil)   总被引:1,自引:0,他引:1  
Gholivand MB  Sharifpour F 《Talanta》2003,60(4):707-713
A poly(vinyl chloride) membrane based on glyoxal bis(2-hydroxyanil) as membrane carrier was prepared and investigated as a Cr(III)-selective electrode. The electrode has a linear dynamic range of 3.0×10−6-1.0×10−2 mol l−1, with a Nernstian slope of 19.8±0.5 mV per decade and a detection limit of 6.3×10−7 mol l−1. It has a fast response time of <20 s and can be used for at least 3 months without any considerable divergence in potential. The proposed electrode revealed good sensitivities for Cr(III) over a wide variety of metal ions and could be used in a pH range of 2.7-6.5. Above all, the membrane sensor has been used very successfully for the analysis of some food materials and alloys for the determination of Cr(III) ion.  相似文献   

3.
The chelate complexes of the types (1) and (2) have been synthesized and characterized by IR and NMR spectroscopy. The lower shift of the ν(P-Se) bands and downfield shift of the 31P-{1H}NMR signals for both P(III) and P(V) atoms in 1 and 2 compared to the corresponding free ligands indicate chelate formation through selenium donor. 1 and 2 show terminal ν(CO) bands at 1977 and 1981 cm−1, respectively, suggesting high electron density at the metal center. The molecular structure of 2 has been determined by single-crystal X-ray diffraction. The rhodium atom is at the center of a square planar geometry having the phosphorus and selenium atoms of the chelating ligand at cis-position, one carbonyl group trans- to selenium and one chlorine atom trans- to phosphorus atom. 1 and 2 undergo oxidative addition (OA) reaction with CH3I to produce acyl complexes (3) and (4), respectively. The kinetics of the OA reactions reveal that 1 undergoes faster reaction by about 4.5 times than 2. The catalytic activity of 1 and 2 in carbonylation of methanol was higher than that of the well known species [Rh(CO)2I2] and 2 shows higher catalytic activity compared to 1.  相似文献   

4.
Al3+ selective sensor has been fabricated from poly(vinyl chloride) (PVC) matrix membranes containing neutral carrier morin as ionophore. Best performance was exhibited by the membrane having composition as morin:PVC:sodium tetraphenyl borate:tri-n-butylphosphate in the ratio 5:150:5:150 (w/w, mg). This membrane worked well over a wide activity range of 5.0 × 10−7 to 1.0 × 10−1 M of Al3+ with a Nernstian slope of 19.7 ± 0.1 mV/decade of Al3+ activity and a limit of detection 3.2 × 10−7 M. The response time of the sensor is ∼5 s and membrane could be used over a period of 2 months with good reproducibility. The proposed sensor works well over a pH range (3.5-5.0) and demonstrates good discriminating power over a number of mono-, di- and trivalent cations. The sensor can also be used in partially non-aqueous media having up to 20% (v/v) methanol, ethanol or acetone content with no significant change in the value of slope or working activity range. The sensor has also been used in the potentiometric titration of Al3+ with EDTA and for its determination in zinc plating mud and red mud.  相似文献   

5.
The two nickel chelates of Schiff bases, 3-hydroxy-N-{2-[(3-hydroxy-N-phenylbutyrimidoyl)-amino]-phenyl}-N′-phenylbutyramidine (M1) and bis-4-(ethyliminomethyl)naphthalene-1-ol (M2), have been synthesized and explored as ionophores for preparing PVC-based membrane sensors selective to nickel ion. The influences of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (w/w; mg) of (M1): PVC:NaTPB:CN in the ratio 5:150:5:150. The sensor shows a linear potential response for Ni2+ over a wide concentration range 1.6 × 10−7 to 1.0 × 10−2 M with Nernstian compliance (30.0 ± 0.2 mV/decade of activity) within pH range 2.5-9.5 and a fast response time of 10 s. The sensor has been found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol, and acetonitrile and could be used for a period of 4 months. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of nickel in real samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants.  相似文献   

6.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on 1,8-dibenzyl-1,3,6,8,10,13-hexaazacyclotetradecane-Ni(II) as a membrane carrier with unique selectivity toward thiocyanate is reported. The influence of membrane composition, pH and foreign anions were investigated. The sensor exhibits a Nernstian response for thiocyanate over a wide concentration range of 3.3×10−6 to 0.10 M, with a slope 58.4±0.3 mV per decade. The limit of detection is 3.0×10−6 M SCN. The sensor has a response time of <20 s and can be used for at least 2 months without any considerable divergence in potential. The proposed electrode shows fairly a good discriminating ability towards SCN ion in comparison to other anions. It was successfully applied to direct determination of thiocyanate in urine and saliva and it was also used as an indicator electrode in titration of thiocyanate with Ag+ ions.  相似文献   

7.
A highly selective electrode for iodide ion based on a thiopyrilium derivative as an excellent ionophore is described. At pH 5.5-8.0, the electrode responds to iodide ion in a linear range from 1.0×10−1 to 8.0×10−7 M with a slope of 60.2 mV per decade, and a detection limit of 2.0×10−7 M. Selectivity coefficients determined with the match potential method (MPM) indicate that the interference from inorganic and organic anions is very small. The proposed sensor shows a fast response time of approximately 15 s. It was applied as an indicator electrode in titration of iodide with Ag+.  相似文献   

8.
Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone (BHAB) was used as new N-N Schiffs base which plays the role of an excellent ion carrier in the construction of a Cu(II) membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 55% o-nitrophenyloctyl ether (NPOE), 7% BHAB and 8% oleic acid (OA). This sensor shows very good selectivity and sensitivity towards copper ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The effect of membrane composition and pH and influence of additive anionic on the response properties of electrode were investigated. The electrode exhibits a Nernstian behavior (with slope of 29.6 mV per decade) over a very wide concentration range (5.0 × 10−8 to 1.0 × 10−2 mol L−1) with a detection limit of 3.0 × 10−8 mol L−1 (2.56 ng mL−1). It shows relatively fast response time, in whole concentration range (<15 s), and can be used for at least 12 weeks in the pH range of 2.8-5.8. The proposed sensor was successfully used to determination of copper in different water samples and as indicator electrode in potentiometric titration of copper ion with EDTA.  相似文献   

9.
A systematic study was conducted on the Cr catalysed tri- and tetramerisation of ethylene using bis(diphenylphosphino)amine ligands with N-aryl functionality. This study revealed that the oligomerisation reaction product selectivity is primarily dependent on the structure and size of the N-aryl groups.

Addition of sufficient steric bulk to the N-phenyl group via ortho-alkyl substitution increased the combined 1-hexene and 1-octene selectivity (overall alpha selectivity) to above 82% at an overall 1-octene selectivity of 56%. The introduction of a single carbon spacer between the N-atom and the aryl-moiety, as well as the addition of branching on this carbon, resulted in further selectivity improvements, achieving an overall 1-octene selectivity of 64% and an overall alpha selectivity of 84%. This was obtained at catalyst productivities in excess of 1,000,000 g/g Cr/h.  相似文献   


10.
A PVC membrane electrode for lead ions based on 5,5′-dithiobis-(2-nitrobenzoic acid) as membrane carrier was prepared. The electrode exhibits a Nernstian response for Pb2+ over a wide concentration range (1.0×10−2–4.0×10−6 M). It has a relatively fast response time and can be used for at least 3 months without any divergence in potentials. The proposed electrode revealed good selectivities for Pb2+ over a wide variety of other metal ions and could be used in a pH range of 2.0–7.0. It was used as an indicator electrode in potentiometric titration of lead ions and in direct determination of lead in water samples.  相似文献   

11.
Reaction of an alkyne‐bridged dicobalt complex, [Co2(CO)6(μ‐Me3SiC=Cpy)] 4 , with bis(diphenylphosphino)methylene (DPPM) or bis(diphenylphosphino)ethylene (DPPE) in THF at 55 °C yielded a DPPM or DPPE doubly bridged dicobalt compound, [{μ‐P,P‐PPh2CH2PPh2}Co2(CO)4(μ‐Me3SiC=Cpy)] 5 or [{μ‐P,P‐PPh2CH2CH2PPh2}Co2(CO)4(μ‐Me3SiC≡Cpy)] 6 . Compound 5 and 6 were characterized by spectroscopic means as well as X‐ray crystal structure determination.  相似文献   

12.
The complexation reaction between palladium (II) acetate, and 1,1′-bis(diphenylphosphino)ferrocene, DPPF, was investigated in two different deuterated solvents CDCl3 and DMSO at various temperatures using 31P NMR spectroscopy. The exchange between free and complexed DPPF is slow on the NMR time scale and consequently, two 31P NMR signals were observed. At metal ion-to-ligand mole ratio larger than 1, only one 31P NMR signal was observed, indicating the formation of a 1:1 Pd2+–DPPF complex in solution. The formation constant of the resulting 1:1 complexes was determined from the integration of two 31P signals. The values of the thermodynamic parameters (ΔH, ΔS and ΔG298) for complexation were determined from the temperature dependence of stability constants. It was found that, in both solvents, the resulting complex is mainly entirely enthalpy stabilized and the ΔH compensates the TΔS contribution.  相似文献   

13.
Gupta VK  Singh LP  Chandra S  Kumar S  Singh R  Sethi B 《Talanta》2011,85(2):970-974
Poly(vinyl chloride) (PVC)-based membranes of N,N-bis-succinamide-based dendritic molecule with tetrabutyl ammonium bromide (TBAB) as a cation inhibitor and dibutylphthalate (DBP), dioctylphthalate (DOP), dibutyl (butyl) phosphonate (DBBP) and 1-chloronaphthalene (CN) as plasticizing solvent mediators were prepared and used as nitrate ion-selective electrodes. Optimum performance was observed with the membrane having I-PVC-TBAB-DBP in the ratio 1:33:1:65 (w/w). The electrode has a linear response to nitrate with a detection limit of 3.9 × 10−5 ± 0.07 M and Nernstian compliance (57.0 ± 0.2 mV/decade) between pH 2.8 and 9.6 with a fast response time of about 20 s. The selectivity coefficient values of the order of 0.001 for mono-; bi- and trivalent anions; indicate high selectivity for nitrate ions over these anions. The preparation procedure of the electrode is very easy and inexpensive. The electrodes were used over a period of 45 days with good reproducibility. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of nitrate ions in waste water samples.  相似文献   

14.
利用溶胶-凝胶技术包埋电活性物质,制备溶胶-凝胶膜修饰的碳酸根离子选择电极。探索了Sol-Gel膜修饰CO32-选择电极的制备方法、测试条件及共存物的影响。电极的线性范围1.0×10-1~1.0×10-5mol/L,相关系数R2=0.993,检测限8.9×10-6mol/L,响应斜率22.1 mV/pCO3。电极稳定性和重现性良好,用于实际样品测定,回收率95.9%~99.0%。  相似文献   

15.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on butane -2,3-dione bis(salicylhydrazonato) zinc(II) [Zn (BDSH)] complex as carrier for thiocyanate-selective electrode is reported. The influence of membrane composition, pH and possible interfering anions were investigated on the response properties of the electrode. The sensor responds to thiocyanate in linear range from 1.0 × 10−6 to 1.0 × 10−1 M with a slope −56.5 ± 1.1 mV decade−1, over a wide pH range of 3.5-8.5. The limit of detection of the electrode was 7.0 × 10−7 M SCN. Selectivity coefficients determined with fixed interference method (FIM) indicate a good discriminating ability towards SCN ion in comparison to other anions. The proposed sensor has a fast response time of about 5-15 s and can be used for at least 3 months without any considerable divergence in potential. It was applied as indicator electrode in titration of thiocyanate with Ag+ and in potentiometric determination of thiocyanate in saliva and urine samples.  相似文献   

16.
Highly selective poly(vinyl chloride) (PVC) membrane electrodes based on bis(2-mercaptobenzoxazolato)mercury(II) [Hg(MBO)2] and bis(2-pyridinethiolato)mercury(II) [Hg(PT)2] complexes as new carriers for thiocyanate-selective electrodes are reported. The electrodes were prepared by coating the membrane solution containing PVC, plasticizer, carriers and additives on the surface of graphite electrodes. Influence of the membrane composition, pH and possible interfering anions were investigated on the response properties of the electrodes. Both sensors exhibited Nernstian responses towards thiocyanate over a wide concentration range of 1×10−6 to 0.1 M, with slopes of 60.6±0.8 and 57.5±1.2 mV per decade of thiocyanate concentration for Hg(MBO)2 and Hg(PT)2 carriers, respectively, over a wide pH range of 3-11. The limit of detection for both electrodes was ∼6×10−7 M. The sensors have response times of ≤5 s and can be used for at least 2 months without any considerable divergence in their potential response. The proposed electrodes show fairly good discrimination of thiocyanate over several inorganic and organic anions. The electrodes were successfully applied to direct determination of thiocyanate in saliva and as indicator electrodes in precipitation titrations.  相似文献   

17.
Singh AK  Saxena P 《Talanta》2005,66(4):993-998
A new highly Tl(I)-selective PVC membrane electrode based on tetrathia macrocycle 6,7: 14,15-dibenzo-5,8,13,16-tetraoxo-1,4,9,12-tetrathiacyclohexadecane [Bz2O4(16)aneS4] (I) as membrane carrier, o-nitrophenyloctyl ether (o-NPOE) as solvent mediator and potassium tetrakis(p-chlorophenyl)borate (KTpClPB) as lipophilic additive has been developed. The best performance was given by the membrane of macrocycle (I) with composition 3:120:1.5:50 (I:o-NPOE:KTpClPB:PVC). This electrode exhibits a Nernstian response to Tl(I) ions in the concentration range 1.0 × 10−1-2.23 × 10−6 M with a slope of 58.2 mV/decade of concentration and a detection limit of 1.58 × 10−6 M. The response time of the sensor is 12 s and can be used over a period of 4 months with good reproducibility. The proposed electrode revealed good selectivity over a wide variety of other cations including alkali, alkaline earth, heavy and transition metals. The electrode works well over a pH range of 3.2-11.5 and in partially non-aqueous medium with up to 30% organic content. The sensor was also used as an indicator electrode in potentiometric titration of Tl(I) ions with KI solution.  相似文献   

18.
A new modified carbon paste electrode based on a recently synthesized mercury (II) complex of a pyridine containing proton transfer compound as a suitable carrier for Br ion is described. The electrode has a linear dynamic range between 3.00×10−2 and 1.0×10−5 M with a near-Nernastian slope of 61.0±0.9 mV per decade and a detection limit of 4.0×10−6 M (0.32 ppm). The potentiometric response is independent of the pH of the solution in the pH range 4.0–8.3. The electrode possesses the advantages of low resistance, fast response and good over a variety of other anions. It was applied as an indicator electrode in potentiometric titration of bromide ions and for the recovery of Br from tap water.  相似文献   

19.
Poly(n-butyl acrylate) membranes for potentiometric ion-selective electrodes were developed and studied on example of lead-selective sensors. A novel approach resulting in Nernstian responses of tested sensor was proposed. Introduction of 5% (w/w) hydroxyethyl methacrylate into n-butyl acrylate moiety resulted in significant improvement of sensor analytical parameters. For the latter membrane material linear responses were obtained within lead activities range from 10−2 to 10−9 mol/dm3, while for poly(n-butyl acrylate) based membranes pretreated in the same manner super-Nernstian behavior was obtained in a parallel experiment. Electrochemical impedance spectroscopy studies did not reveal significant differences between these two membranes, also similar lead ions diffusion coefficients were determined using inductively coupled plasma mass spectrometry with laser ablation.The difference between two kinds of membranes was found to concern higher Pb(II) ions contents in the surface part of the membrane with hydroxyethyl methacrylate, resulting in balanced Pb ions fluxes from/to the membrane.  相似文献   

20.
Mashhadizadeh MH  Shoaei IS  Monadi N 《Talanta》2004,64(4):1048-1052
A new PVC membrane potentiometric sensor that is highly selective to Fe(III) ions was prepared by using 2-[(2-hydroxy-1-propenyl-buta-1,3-dienylimino)-methyl]-4-p-tolylazo-phenol [HPDTP] as a suitable carrier. The electrode exhibits a linear response for iron(III) ions over a wide concentration range (3.5 × 10−6 to 4.0 × 10−2) with a super Nernstian slope of 28.5 (±0.5) per decade. The electrode can be used in the pH range from 4.5 to 6.5. The proposed sensor shows fairly a good discriminating ability towards Fe3+ ion in comparison to some hard and soft metals such as Fe2+, Cd2+, Cu2+, Al3+ and Ca2+. It has a response time of <15 s and can be used for at least 2 months without any measurable divergence in response characteristics. The electrode was used in the direct determination of Fe3+ in aqueous samples and as an indicator electrode in potentiometric titration of Fe(III) ions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号