首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 668 毫秒
1.
A new PVC membrane electrode for manganese(II) ion based on a recently synthesized Schiff base of 5-[(4-nitrophenylazo)-N-hexylamine]salicylaldimine is reported. The electrode exhibits a Nernstian response for Mn2+ ions over a wide concentration range (4.0 × 10−7 to 1.8 × 10−2 mol L−1) with a slope of 30.1 (±1.0). The limit of detection is 1.0 × 10−7 mol L−1. The electrode has a fast response time (∼10 s), a satisfactory reproducibility and relatively long life time. The proposed sensor revealed good selectivities over a wide variety of other cations include hard and soft metals. This electrode could be used in a pH range of 4.5-7.5. It was used as an indicator electrode in potentiometric titration of manganese(II) ions with EDTA solution.  相似文献   

2.
A PVC membrane electrode for iodide ions based on Cu(I)-bathocuproine as ionophore in membrane composition is prepared. The electrode exhibits a linear response over a wide concentration range 5.0×10−6 to 2.0×10−1 mol l−1 with a detection limit 1.0×10−6 mol l−1. The proposed membrane electrode shows Nernstian behavior with a slope of −56.8 mV/decade, a fast response time 10 s and a lifetime at least 3 months. Iodide-selective electrode reveals good selectivities for iodide ion over a wide variety of the other anions and can be used in pH range of 3-9. It can also be used as an indicator electrode in potentiometric titration of iodide ion.  相似文献   

3.
In this article a new coated platinum Cu2+ ion selective electrode based on 2-((2-(2-(2-(2-hydroxy-5-methoxybenzylideneamino)phenyl)disufanyl)phenylimino) methyl)-4-methoxyphenol Schiff base (L1) as a new ionophore is described. This sensor has a wide linear range of concentration (1.2 × 10−7-1.0 × 10−1 mol L−1) and a low detection limit of 9.8 × 10−8 mol L−1of Cu(NO3)2. It has a Nernstian response with slope of 29.54 ± 1.62 mV decade−1 and it is applicable in the pH range of 4.0-6.0 without any divergence in potentioal. The coated electrode has a short response time of approximately 9 s and is stable at least for 3.5 months. The electrode shows a good selectivity for Cu2+ ion toward a wide variety of metal ions. The proposed sensor was successfully applied for the determination of Cu2+ ion in different real and environmental samples and as indicator electrode for potentiometric titration of Cu2+ ion with EDTA.  相似文献   

4.
A new PVC membrane strontium ion-selective electrode has been constructed using 6-(4-nitrophenyl)-2-phenyl-4,4-dipropyl-3,5-diaza-bicyclo[3,1,0] hex-2-ene (NPDBH) as a neutral ionophore. The electrode was prepared with 7% NPDBH (as ionophore), 57% acetophenone (as plasticizer), 30% PVC and 6% oleic acid (as lipophilic additive). The electrode responds to Sr2+ ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 × 10−6-1.0 × 10−1 mol L−1 and in a pH range of 3.0-10.0. The limit of detection was 2.4 × 10−7 mol L−1. It has a response time of <20 s and can be used for at least three months without any divergence in potentials. The proposed electrode shows good discrimination of Sr2+ ion from several cations. The effect of organic solvents on electrode response was examined. The results show that this electrode can be used in ethanol media up to 15% (v/v) concentration without interference. The isothermal temperature coefficient of this electrode amounted to 0.00019 V/°C. The electrode was found to work well under laboratory conditions. It was successfully applied to the determination of strontium ions in human urine and bone digests.  相似文献   

5.
Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone (BHAB) was used as new N-N Schiffs base which plays the role of an excellent ion carrier in the construction of a Cu(II) membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 55% o-nitrophenyloctyl ether (NPOE), 7% BHAB and 8% oleic acid (OA). This sensor shows very good selectivity and sensitivity towards copper ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The effect of membrane composition and pH and influence of additive anionic on the response properties of electrode were investigated. The electrode exhibits a Nernstian behavior (with slope of 29.6 mV per decade) over a very wide concentration range (5.0 × 10−8 to 1.0 × 10−2 mol L−1) with a detection limit of 3.0 × 10−8 mol L−1 (2.56 ng mL−1). It shows relatively fast response time, in whole concentration range (<15 s), and can be used for at least 12 weeks in the pH range of 2.8-5.8. The proposed sensor was successfully used to determination of copper in different water samples and as indicator electrode in potentiometric titration of copper ion with EDTA.  相似文献   

6.
A PVC membrane electrode for copper ion based on 1,3-dithiane,2-(4-methoxy phenyl) as ionophore and o-nitrophenyl octyl ether as a plasticizer is demonstrated. The electrode exhibits a Nernstian slope of 29.5±1 mV per decade in a linear range of 3.0×10−6 to 5.0×10−2 M for Cu2+ ion. The detection limit of this electrode is 1.0×10−6 mol/l. This sensor has a very short response time of about 5 s and could be used in a pH range of 4.0-7.0. High selectivity was obtained over a wide variety of metal ions. The proposed electrode was successfully applied as an indicator electrode for the potentiometric titration of copper ion with EDTA and for the direct determination of copper in river water.  相似文献   

7.
The two macrocyclic pendant ligands 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetramethylacrylate-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-di ene (L1) and 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetra(2-cyano ethane)-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-diene (L2) have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Tb(III) ions. Effects of various plasticizers and anion excluders were studied in detail and improved performance was observed. The best performance was obtained for the membrane sensor having a composition of L1: PVC:1-CN:NaTPB in the ratio of 6: 32: 58: 4 (w/w; mg). The performance of the membrane based on L1 was compared with polymeric membrane electrode (PME) as well as with coated graphite electrode (CGE). The electrodes exhibit Nernstian slope for Tb3+ ions with limits of detection of 3.4 × 10−8 mol L−1 for PME and 5.7 × 10−9 mol L−1 for CGE. The response time for PME and CGE was found to be 10 s and 8 s, respectively. The potentiometric responses are independent of the pH of the test solution in the pH range 3.0-7.5 for PME and 2.0-8.5 for CGE. The CGE has found to work satisfactorily in partially non-aqueous media upto 30% (v/v) content of methanol, ethanol and 20% (v/v) content of acetonitrile and could be used for a period of 5 months. The CGE was used as indicator electrode in the potentiometric titration of Tb3+ ions with EDTA and in determination of fluoride ions in various samples. It can also be used in direct determination of Tb3+ ions in tap water and various binary mixtures with quantitative results.  相似文献   

8.
The two chromium chelates of Schiff bases, N-(acetoacetanilide)-1,2-diaminoethane (L1) and N,N′-bis(acetoacetanilide)-triethylenetetraammine (L2), have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Cr(III). The addition of lipophilic anion excluder (NaTPB) and various plasticizers viz. o-Nitrophenyloctyl ether (o-NPOE), dioctylpthalate (DOP), dibutylphthalate (DBP), tris(2-ethylhexyl)phosphate (TEHP), and benzyl acetate (BA) have found to improve the performance of the sensors. The best performance was obtained for the membrane sensor having a composition of L1:PVC:DBP:NaTPB in the ratio 5:150:250:3 (w/w). The sensor exhibits Nernstian response in the concentration range 8.9 × 10−8 to 1.0 × 10−1 M Cr3+ with limit of detection 5.6 × 10−8 M. The proposed sensor manifest advantages of relatively fast response (10 s) and good selectivity over some alkali, alkaline earth, transition and heavy metal ions. The selectivity behavior of the proposed electrode revealed a considerable improvement as compared to the best previously PVC-membrane electrode for chromium(III) ion. The potentiometric response of the proposed sensor was independent of pH of the test solution in the range of 2.0-7.0. The sensor has found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 3 months. The proposed electrode was used as an indicator electrode in potentiometric titration of chromium ion with EDTA and in direct determination in different water and food samples.  相似文献   

9.
A plasticized poly (vinyl chloride) membrane electrode based on 1,3-bis(2-cyanobenzene)triazene (CBT) for highly selective determination of platinum(II) (in PtCl42− form) is developed. The electrode showed a good Nernstian response (29.8 ± 0.3 mV decade−1) over a wide concentration range (1.0 × 10−6 to 1.0 × 10−2 mol L−1). The limit of detection was 5.0 × 10−7 mol L−1. The electrode has a response time of about 40 s, and it can be used for at least 1 month without observing any considerable deviation from Nernstian response. The proposed electrode revealed an excellent selectivity toward platinum(II) ion over a wide variety of alkali, alkaline earth, transition, and heavy metal ions, and it could be used in the pH range of 3.2-5.1. The practical utility of the electrode has been demonstrated by its use in determination of platinum ion in, alloy, tap, mineral and river water samples.  相似文献   

10.
This study presents the development of an original electrode, employing 6-methy-4-{[1-(1H-pyrrol-2-yl)methylidene]amino}-3-thioxo-3,4dihydro-1,2,4-triazin-5(2H)-one (PMTO) as a suitable ionophore. Interestingly, the electrode performance provided a very good response for Yb3+ in a wide concentration range (from 1.0 × 10−6 to 1.0 × 10−1 mol L−1) with a detection limit of 4.6 × 10−7 mol L−1 and a slope of 19.5 ± 0.3 mV per decade of Yb3+ concentration. Furthermore, it possessed a fast response time of about 10 s and it functioned in the pH range of 3.3-8.0 with a usage of at least 2 months without observing any deviations. Noticeably, the proposed electrode revealed an excellent selectivity for Yb3+ over a broad variety of alkali, alkaline earth, transition and heavy metal ions. The practical applicability of the electrode was demonstrated by its utilization as an indicator electrode in the potentiometric titration of Yb3+ ions with EDTA and in the determination of F in mouth wash samples. Additionally, it was also applied for the determination of Yb3+ ions in binary mixtures.  相似文献   

11.
A poly(nickel(II) tetrasulfophthalocyanine)/multi-walled carbon nanotubes composite modified electrode (polyNiTSPc/MWNTs) was fabricated by electropolymerization of NiTSPc on MWNTs-modified glassy carbon electrode (GCE). The modified electrode was found to be able to greatly improve the emission of luminol electrochemiluminescence (ECL) in a solution containing hydrogen peroxide. Glucose oxidase (GOD) was immobilized on the surface of polyNiTSPc/MWNTs modified GC electrode by Nafion to establish an ECL glucose sensor. Under the optimum conditions, the linear response range of glucose was 1.0 × 10−6 to 1.0 × 10−4 mol L−1 with a detection limit of 8.0 × 10−8 mol L−1 (defined as the concentration that could be detected at the signal-to-noise ratio of 3). The ECL sensor showed an outstanding well reproducibility and long-term stability. The established method has been applied to determine the glucose concentrations in real serum samples with satisfactory results.  相似文献   

12.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on butane -2,3-dione bis(salicylhydrazonato) zinc(II) [Zn (BDSH)] complex as carrier for thiocyanate-selective electrode is reported. The influence of membrane composition, pH and possible interfering anions were investigated on the response properties of the electrode. The sensor responds to thiocyanate in linear range from 1.0 × 10−6 to 1.0 × 10−1 M with a slope −56.5 ± 1.1 mV decade−1, over a wide pH range of 3.5-8.5. The limit of detection of the electrode was 7.0 × 10−7 M SCN. Selectivity coefficients determined with fixed interference method (FIM) indicate a good discriminating ability towards SCN ion in comparison to other anions. The proposed sensor has a fast response time of about 5-15 s and can be used for at least 3 months without any considerable divergence in potential. It was applied as indicator electrode in titration of thiocyanate with Ag+ and in potentiometric determination of thiocyanate in saliva and urine samples.  相似文献   

13.
A hydrogen ion-selective poly(vinyl chloride) (PVC) membrane electrode was developed using 2-(4-methoxy phenyl) 6-(4-nitrophenyl)-4-phenyl-1,3-diazabicyclo [3.1.0] hex-3-ene as ionophore. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, and the amount of additive on the potential response of pH sensor were investigated. This H+-selective membrane electrode gave a linear response over the pH range 0-4 (10−4 to 1 mol L−1 HCl) with slope of 57.4 ± 0.3 mV pH−1 and limit of detection 6.3 × 10−5 mol L−1 at 20 °C. Also, hydrofluoric acid did not influence the surface of this electrode and thus it was maintained without showing any changes in potentials after being used in a hydrofluoric acid solution. The equilibrium water content of the electrode was determined in the presence of two different plasticizers as membrane solvent. The alkaline cation binding affinity of ionophore was very low that prove these cations do not have specific interaction with this ionophore. The electrode had fairly low electrical resistance, good potential stability and reproducibility. It has a rapid potential response to changes of pH (10 s), easily used in a single channel wall-jet flow injection system with good reproducibility (RSD% = 1.67%) and high reversibility. It was used as indicator electrode in potentiometric determination of pH in real samples.  相似文献   

14.
In this work, a novel La(III) membrane sensor based on 8-amino-N-(2-hydroxybenzylidene)naphthylamine (AIP) is presented. This electrode reveals good selectivity for La3+ over a wide variety of lanthanides metal ions. Theoretical calculations and conductance study of AIP to lanthanum and some other metal ions were carried out and confirmed selectivity toward La(III) ions. The electrode comprises 7% AIP, 30% PVC, 61% NPOE and 2% KTpClPB. The sensor displays a linear dynamic range between 1.0 × 10−7 and 1.0 × 10−1 M, with a nice Nernstian slope of 20.3 ± 0.3 mV per decade and a detection limit of 8.0 × 10−8 M. The potentiometric response is independent of pH in the range of 4.0-9.0. The proposed sensor posses the advantage of short response time, and especially, very good selectivity towards a large number of cations, such as Sm(III), Ce(III, Pr(III), Yb(III) and Hg(II), low detection limit and wide linear dynamic range in comparison with former ones. The electrode can be used for at least seven weeks without any considerable divergence in the potentials. It was used as an indicator electrode in the potentiometric titration of La(III) ions with EDTA. The sensor was applied to the determination of La(III) ions concentration in binary mixtures. It was also applied for the determination of fluoride ions in mouth wash preparations.  相似文献   

15.
Singh AK  Saxena P  Mehtab S  Gupta B 《Talanta》2006,69(2):521-526
A new PVC membrane electrode based on 5,7,12,14-dibenzo-2,3,9,10-tetraoxa-1,4,8,11-tetraazacyclotetradecane (I) as an ion carrier, o-nitrophenyloctyl ether (o-NPOE) as solvent mediator and sodium tetraphenylborate (NaTPB) as lipophilic additive was fabricated and investigated as Sr2+-selective electrode. The best performance was exhibited by the membrane having composition 8:200:4:120 (I:o-NPOE:NaTPB:PVC). The electrode exhibited a Nernstian response for strontium ion over a wide concentration range 3.98 × 10−6 to 1.0 × 10−1 M with a slope of 29.0 ± 0.1 mV/decade of concentration and a detection limit of 2.82 × 10−6 M. It showed a response time of less than 10 s and could be used for at least 3 months without any divergence in potential. The proposed electrode showed a good discriminating ability towards strontium(II) ion over a wide variety of other metal ions including alkali, alkaline earth, transition, and heavy metal ions. The electrode can be used in the pH range of 2.5-10.5 and in mixtures containing up to 35% (v/v) non-aqueous content. It was used as an indicator electrode in potentiometric titration of strontium ion against EDTA.  相似文献   

16.
A highly selective membrane electrode based on nickel(II)-1,4,8,11,15,18,22,25-octabutoxyphthalocyanine (NOBP) is presented. The proposed electrode shows very good selectivity for thiocyanate ions over a wide variety of common inorganic and organic anions. The sensor displays a near Nernstian slope of −58.7 ± 0.6 mV per decade. The working concentration range of the electrode is 1.0 × 10−6 to −1.0 × 10−1 M with a detection limit of 5.7 × 10−7 M (33.06 ng/mL). The response time of the sensor in whole concentration ranges is very short (<10 s). The response of the sensor is independent on the pH range of 4.3-9.8. The best performance was obtained with a membrane composition of 30% PVC, 65% dibutyl phthalate, 3% NOBP and 2% hexadecyltrimethylammonium bromide. It was successfully applied to direct determination of thiocyanate in biological samples, and as an indicator electrode for titration of thiocyanate ions with AgNO3 solution.  相似文献   

17.
Cobalt(II) phthalocyanine [Co(II)Pc] is used as both an ionophore and chromogen for batch and flow injection potentiometric and spectrophotometric determination of anionic surfactants (SDS), respectively. The potentiometric technique involves preparation of a polymeric membrane sensor by dispersing [Co(II)Pc] in a plasticized PVC membrane. Under batch mode of operation, the sensor displays a near-Nernstian slope of −56.5 mV decade−1, wide response linear range of 7.8 × 10−4 to 8.0 × 10−7 mol L−1, lower detection limit of 2.5 × 10−7 mol L−1 and exhibits high selectivity for anionic surfactants in the presence of many common ions. Under hydrodynamic mode of operation (FIA), the slope of the calibration plot, limit of detection, and working linear range are −51.1 mV decade−1, 5.6 × 10−7 and 1.0 × 10−3 to 1.0 × 10−6 mol L−1, respectively. The spectrophotometric method is based on the use of [Co(II)Pc] solution in dimethylsulfoxide (DMSO) as a chromogenic reagent. The maximum absorption of the reagent at 658 nm linearly decreases with the increase of anionic surfactant over the concentration range 2-30 μg mL−1. The lower limit of detection is 1 μg mL−1 and high concentrations of many interfering ions are tolerated. Flow injection spectrophotometric measurements are carried out by injection of the surfactant test solution in a stream of the reagent in DMSO. The sample throughput, working range and lower detection limit are 25-30 samples h−1, 4-60 and 2 μg mL−1, respectively. The potentiometric and spectrophotometric techniques are applied to the batch and flow injection measurements of anionic surfactants in some commercial detergent products. The results agree fairly well with data obtained using the standard methylene blue spectrophotometric method.  相似文献   

18.
Plasticized membranes using 2,3,4:12,13,14-dipyridine-1,3,5,8,11,13,15,18-octaazacycloicosa-2,12-diene (L1) and 2,3,4:12,13,14-dipyridine-1,5,8,11,15,18-hexamethylacrylate-1,3,5,8,11,13,15,18-octaazacycloicosa-2,12-diene (L2) have been prepared and explored as Ce(III) selective sensors. Effect of various plasticizers viz. dibutylphthalate (DBP), tri-n-butylphthalate (TBP), o-nitrophenyloctylether (o-NPOE), dioctylphthalate (DOP), benzylacetate (BA) and anion excluders, sodium tetraphenylborate (NaTPB) and potassium tetrakis p-(chlorophenyl) borate was studied in detail and improved performance was observed. Optimum performance was observed for the membrane sensor having a composition of L2:PVC:o-NPOE:KTpClPB in the ratio of 6:34:58:2 (w/w, mg). The performance of the membrane based on L2 was compared with polymeric membrane electrode (PME) as well as with coated graphite electrode (CGE). The electrodes exhibit Nernstian slope for Ce(III) ions with limits of detection of 8.3 × 10−8 mol L−1 for PME and 7.7 × 10−9 mol L−1 for CGE. The response time for PME and CGE was found to be 12 s and 10 s respectively. The potentiometric responses are independent of the pH of the test solution in the pH range 3.5-7.5 for PME and 2.5-8.5 for CGE. The CGE could be used for a period of 5 months. The practical utility of the CGE has been demonstrated by its usage as an indicator electrode in potentiometric titration of oxalate and fluoride ions with Ce(III) solution. The proposed electrode was also successfully applied to the determination of fluoride ions in mouthwash solution and oxalate ions in real samples.  相似文献   

19.
Novel 5-amino-1,3,4-thiadiazole-2-thiol unit based macrocyclic ionophore 5,11,17-trithia-1,3,7,9,13,15,19,20,21-nonaazatetracyclo[14.2.1.14,7.110,13]henicosa-4(20),10(21),16(19)-triene-6,12,18-trithione (M1), was synthesized and characterized. Preliminary studies on M1 have showed that it has more the affinity toward Cd2+ ion. Thus, the macrocyclic ionophore (M1) was used as electroactive material in the fabrication of PVC-membrane electrodes such as polymeric membrane electrode (PME), coated graphite electrode (CGE) and coated pyrolytic graphite electrode (CPGE) were prepared and its performance characteristic were compared with. The electroanalytical studies performed on PME, CGE and CPGE revealed that CPGE having membrane composition M1:PVC:1-CN:NaTPB in the ratio of 7:37:54:2 exhibits the best potentiometric characteristics in terms of detection limit of 7.58 × 10−9 mol L−1, Nernstian slope of 29.6 mV decade−1 of activity. The sensor was found to be independent of pH in the range 2.5–8.5. The sensor showed a fast response time of 10 s and could be used over a period of 4 months without any significant divergence in its potentiometric characteristics. The sensor has been employed for monitoring of the Cd2+ ion in real samples and also used as an indicator electrode in the potentiometric titration of Cd2+ ion with EDTA.  相似文献   

20.
A new enantioselective potentiometric sensor containing chiral salen Mn(III) as the chiral selector was designed for the assay of l-mandelic acid (l-MA). Optimized membrane electrodes displayed linear dynamic range from 1 × 10−5 to 1 × 10−1 mol L−1 with a detection limit of 7.2 × 10−6 mol L−1 and a Nernstian response of −58.1 ± 0.5 mV decade−1 towards l-MA within pH range 7.0-10.2. The potentiometric enantioselectivity coefficient () of this sensor was −4.0, indicating that the chiral salen Mn(III) complex-based electrode exhibited fairly good discrimination toward l-MA over counter isomer d-MA. The mechanism of chiral recognition for l-MA is discussed by using HF/STO-3G calculation method simulation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏