首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
We measured the concentrations of Pb and its isotope ratios in coconmittantly obtained tap water and plumbing materials by inductively coupled mass spectrometry (ICP-MS). The Pb concentrations were determined by external calibration with209Bi as an internal standard. Isotope ratios were measured and mass discrimination corrected by normalization to NIST SRM-981 (common lead isotopic standard). Student/s t-test was used to compare the isotopic ratios of206Pb/207Pb,206Pb/208Pb, and207Pb/208Pb in the tap water with those in various plumbing materials. The comparisons revealed that the source of Pb in most of the tap water samples was derived from copper pipe or solder.  相似文献   

2.
The analysis of 204Pb, 206Pb, 207Pb and 208Pb isotope ratios for environmental Pb markers (leaded gasoline, air-borne particulate matter, house window dust) and hair of children was undertaken by the routine quadrupole inductively coupled argon plasma mass spectrometry (Q-ICP-MS). Hair samples collected from 10-year-old children living in Krakow in 1995 and 35 randomly selected children, aged 11, both sexes were included in the current study. Air-borne particles were collected by PM-2.5 (an aerodynamic diameter dac <2.5 μm) and PM-10 (fraction with an dac <10 μm) samplers in the proximity of steel factories situated near Krakow. Imprecision of routine estimations was approximately 0.6–0.7% or less, and was the lowest for the 207Pb/208Pb ratio (approx. 0.2%). These conditions were sufficient to distinguish Pb from air-borne dust from that in gasoline or window dust. No differences were found between Pb in PM-2.5 and PM-10 particles. The associations of the Pb in the these environmental sources and that in hair of children were discussed. The relationships of the Pb isotope ratios and other parameters related to environmental pollution were also analyzed. The analysis of distribution of the 207Pb/208Pb ratio in the hair of children, provided some evidence of the fact that hair lead of approximately 20% of the investigated population could arise from gasoline, while the Pb from air-borne dust and remaining sources can be attributed to approximately 80% of the population.  相似文献   

3.
由于各地区地质结构不同,造成了铅同位素组成具有地域特征。本研究利用电感耦合等离子体质谱测定了福建不同茶园土壤的铅同位素比值,比较了土壤全消解和残渣态两种赋存形态的铅同位素比值的差异,发现残渣态的铅的地域性特征较强,可用来作为地区土壤的判别依据。  相似文献   

4.
The precision of isotopic measurements of Pb by thermal ionization mass spectrometry (TIMS) is limited by the fact that this element does not possess an invariant isotope ratio that can be used for the correction of mass fractionation by internal normalization. Multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) can overcome this limitation, because with plasma ionization, elements with overlapping mass ranges are thought to display identical mass discrimination. With respect to Pb, this can be exploited by the addition of Tl to the sample solutions; the mass discrimination factor obtained for Tl can then be used for the correction of the measured Pb isotope ratios. In this article we present the results of a detailed study that investigates the accuracy and precision of such an external correction technique for mass discrimination based upon the results of multiple analyses of a mixed standard solution of NIST SRM-981 Pb and SRM-997 Tl. Our data indicate that normalization of the Pb isotope ratios to the certified isotopic composition of SRM-997 Tl produces Pb isotopic results that are significantly lower than recently published reference values by TIMS. This systematic offset can be eliminated by renormalization of the Pb data to a different Tl isotopic composition to obtain an empirically determined mass discrimination factor for Pb that generates accurate results. It is furthermore shown that a linear law is least suited for the correction of mass discrimination, whereas a power or exponential law function provide significantly more accurate and precise results. In detail, it appears that a power law may provide the most appropriate correction procedure, because the corrected Pb isotope ratios display less residual correlations with mass discrimination compared to the exponentially corrected data. Using an exponential or power law correction our results, obtained over a period of over seven months, display a precision (2σ) of better than 60 parts per million (ppm) for 208Pb/206Pb and 207Pb/206Pb and of better than 350 ppm for 206Pb/204Pb, 207Pb/204Pb/204Pb, and 208Pb/204Pb. This represents a significant improvement compared to conventional TIMS techniques and demonstrates the potential of MC-ICPMS for routine, high-precision measurements of Pb isotopic compositions.  相似文献   

5.
Precision and accuracy of lead isotope ratios of a volatile lead species (PbEt4) were determined by coupling a capillary GC to a magnetic sector multicollector ICP-MS. PbEt4 was prepared by ethylation of a certified lead isotope solution (NIST SRM 981). Coupling was achieved by a transfer line, which allowed simultaneous introduction of a thallium standard solution to correct for mass discrimination. Seven isotopes (202Hg, 203Tl, 204Pb, 205Tl, 206Pb, 207Pb, 208Pb) were monitored simultaneously with a transient resolution of 50 ms. Pb isotope ratios for the PbEt4 peaks were calculated using transient peak integrals of each isotope signal. Absolute detection limits were 20 (204Pb), 0.7 (206Pb), 1 (207Pb) and 0.3 pg (208Pb). Precision was assessed for five replicate injections of PbEt4 in iso-octane, corresponding to a total amount of 300 pg of Pb. Precision of isotope ratios for 206Pb, 207Pb and 208Pb were better than 0.07% (RSD), with ratios including 204Pb being one order of magnitude worse. Accuracy using mass bias correction via 203Tl/205Tl ranged from 0.18% for 208Pb/206Pb to 0.9% for 208Pb/204Pb.  相似文献   

6.
Lead isotope ratios, viz. 207Pb/206Pb and 208Pb/206Pb, of the commercially available certified reference materials (CRMs) issued in Japan are presented with an objective to provide a data set, which will be useful for the quality assurance of analytical procedures, instrumental performance and method validation of the laboratories involved in environmental lead isotope ratio analysis. The analytical method used in the present study was inductively coupled plasma quadrupole mass spectrometry (ICPQMS) preceded by acid digestion and with/without chemical separation of lead from the matrix. The precision of the measurements in terms of the relative standard deviation (RSD) of triplicated analyses was 0.19% and 0.14%, for 207Pb/20Pb and 208Pb/206Pb, respectively. The trueness of lead isotope ratio measurements of the present study was tested with a few CRMs, which have been analyzed by other analytical methods and reported in various literature. The lead isotopic ratios of 18 environmental matrix CRMs (including 6 CRMs analyzed for our method validation) are presented and the distribution of their ratios is briefly discussed.  相似文献   

7.
In situ Pb isotope data of sulfide samples measured by LA-MC-ICP-MS provide valuable geochemical information for studies of the origin and evolution of ore deposits. However, the severe isobaric interference of 204Hg on 204Pb and the lack of matrix-matched sulfide reference materials limit the precision of Pb isotopic analyses for Hg-rich sulfides. In this study, we observe that Hg forms vapor and can be completely removed from sample aerosol particles produced by laser ablation using a gas exchange device. Additionally, this device does not influence the signal intensities of Pb isotopes. The within-run precision, the external reproducibility and the analytical accuracy are significantly improved for the Hg-rich sulfide samples using this mercury-vapor-removing device. Matrix effects are observed when using silicate glass reference materials as the external standards to assess the relationship of mass fractionation factors between Tl and Pb in sulfide samples, resulting in a maximum deviation of ∼0.20% for 20xPb/204Pb. Matrix-matched reference materials are therefore required for the highly precise and accurate Pb isotope analyses of sulfide samples. We investigated two sulfide samples, MASS-1 (the Unites States Geological Survey reference materials) and Sph-HYLM (a natural sphalerite), as potential candidates. Repeated analyses of the two proposed sulfide reference materials by LA-MC-ICP-MS yield good external reproducibility of <0.04% (RSD, k = 2) for 20xPb/206Pb and <0.06% (RSD, k = 2) for 20xPb/204Pb with the exception of 20xPb/204Pb in MASS-1, which provided an external reproducibility of 0.24% (RSD, k = 2). Because the concentration of Pb in MASS-1 (76 μg g−1) is ∼5.2 times lower than that in Sph-HYLM (394 ± 264 μg g−1). The in situ analytical results of MASS-1 and Sph-HYLM are consistent with the values obtained by solution MC-ICP-MS, demonstrating the reliability and robustness of our analytical protocol.  相似文献   

8.
A new method for the determination of seawater Pb isotope compositions and concentrations was developed, which combines and optimizes previously published protocols for the separation and isotopic analysis of this element. For isotopic analysis, the procedure involves initial separation of Pb from 1 to 2 L of seawater by co-precipitation with Mg hydroxide and further purification by a two stage anion exchange procedure. The Pb isotope measurements are subsequently carried out by thermal ionization mass spectrometry using a 207Pb–204Pb double spike for correction of instrumental mass fractionation. These methods are associated with a total procedural Pb blank of 28 ± 21 pg (1sd) and typical Pb recoveries of 40–60%. The Pb concentrations are determined by isotope dilution (ID) on 50 mL of seawater, using a simplified version of above methods. Analyses of multiple aliquots of six seawater samples yield a reproducibility of about ±1 to ±10% (1sd) for Pb concentrations of between 7 and 50 pmol/kg, where precision was primarily limited by the uncertainty of the blank correction (12 ± 4 pg; 1sd). For the Pb isotope analyses, typical reproducibilities (±2sd) of 700–1500 ppm and 1000–2000 ppm were achieved for 207Pb/206Pb, 208Pb/206Pb and 206Pb/204Pb, 207Pb/204Pb, 208Pb/204Pb, respectively. These results are superior to literature data that were obtained using plasma source mass spectrometry and they are at least a factor of five more precise for ratios involving the minor 204Pb isotope. Both Pb concentration and isotope data, furthermore, show good agreement with published results for two seawater intercomparison samples of the GEOTRACES program. Finally, the new methods were applied to a seawater depth profile from the eastern South Atlantic. Both Pb contents and isotope compositions display a smooth evolution with depth, and no obvious outliers. Compared to previous Pb isotope data for seawater, the 206Pb/204Pb ratios are well correlated with 207Pb/206Pb, underlining the significant improvement achieved in the measurement of the minor 204Pb isotope.  相似文献   

9.
In present research, fifteen surficial and two profile sediment samples were studied in terms of sediment chronology and pollution degree on the ground of pollution indexes such as enrichment factor (EF), contamination factor (CF), Pollution Load Index (PLI) and lead isotope ratios (206Pb/207Pb, 208Pb/206Pb). Lead-210 (polonium-210) activity concentrations were measured by utilizing alpha spectrometry. Sediment chronology was determined via modified CRS mathematical model. Average mass accumulation rates are 0.301 and 0.227 g cm?2 year?1 in Bak?rçay River mouth and Ayval?k offshore stations respectively. Mass accumulation rates do not display the systematic increases along the cores from bottom layers to top layers. In Bak?rçay River mouth station 210Pb flux is higher than the range of global atmospheric 210Pb flux value. Due to the high CF and EF values of Sr both of stations have hydrothermal features. Ayval?k offshore station has displayed Na, Cd pollution since 1945, but Na, Cd, As, Mo, Ag pollutions have existed in Bak?rçay River mouth station since 1983 in terms of CF and EF values. According to PLI index, Bak?rçay River mouth station has “starting level pollution” degree and it displayed an “acute corruption” in 1981. 206Pb/207Pb ratios range from 1.17 to 1.25, 208Pb/206Pb ratios range from 1.99 to 2.16 in study area. When 206Pb/207Pb and 208Pb/206Pb ratios are evaluated with together, it is seen that both of the stations have had the natural (geologic) sediments since 2011.  相似文献   

10.
The potential of high‐precision calcium and lead isotope ratio measurements using laser ablation coupled to multicollector inductively coupled plasma mass spectrometry (LA‐MC‐ICP‐MS) to aid distinction between four genuine and five counterfeit pharmaceutical packaging samples and further classification of counterfeit packaging samples has been evaluated. We highlight the lack of reference materials for LA‐MC‐ICP‐MS isotope ratio measurements in solids. In this case the problem is minimised by using National Institute of Standards and Technology Standard Reference Material (NIST SRM) 915a calcium carbonate (as solid pellets) and NIST SRM610 glass disc for sample bracketing external standardisation. In addition, a new reference material, NIST SRM915b calcium carbonate, has been characterised in‐house for Ca isotope ratios and is used as a reference sample. Significant differences have been found between genuine and counterfeit samples; the method allows detection of counterfeits and aids further classification of packaging samples. Typical expanded uncertainties for measured‐corrected Ca isotope ratio values (43Ca/44Ca and 42Ca/44Ca) were found to be below 0.06% (k = 2, 95% confidence) and below 0.2% for measured‐corrected Pb isotope ratios (207Pb/206Pb and 208Pb/206Pb). This is the first time that Ca isotope ratios have been measured in packaging materials using LA coupled to a multicollector (MC)‐ICP‐MS instrument. The use of LA‐MC‐ICP‐MS for direct measurement of Ca and Pb isotopic variations in cardboard/ink in packaging has definitive potential to aid counterfeit detection and classification. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
A double focusing ICP-MS, equipped with a Micro Concentric Nebulizer, has been used to determine concentrations and isotopic ratios of lead in recent snow samples (1993–1996) from high alpine sites in Switzerland. Concentrations varied between 0.02 ± 0.002 and 5.5 ± 0.15 ng/g and are slightly lower than concentrations reported by Atteia [1], by Batifol et al. [2], and by Wagenbach et al. [3] for precipitation samples from similar remote sites in Europe. Since concentrations of lead in the fresh snow samples were mainly in the lower pg/g range, the method to determine the isotopic ratios 207Pb/206Pb and 208Pb/206Pb had to be optimized. They could finally be determined with an average standard error of 0.14% within 12 min and a total sample consumption of 0.8 mL. The average ratios 207Pb/206Pb and 208Pb/206Pb were 0.875 and 2.117, respectively. These values are comparable to isotopic compositions of lead in aerosols collected in Western Europe [4] and are less radiogenic than predicted by Grousset et al. [5]. Our data indicate that, although lead emissions from traffic have decreased largely during the last 10 years, the contribution from this source in modern snow is still detectable and seems to be equal to the lead input from other anthropogenic sources (e.g. waste incineration, industry).  相似文献   

12.
Aerosols and source related materials (fly ash from refuse incinerators, vehicle exhaust and soil) were collected in April, 2002 in the northern areas of Jeju-do, Korea, and the Pb isotopic ratios (207Pb/206Pb and 208Pb/206Pb) of the samples were measured in order to estimate the Pb sources of the aerosols. The Pb isotopic ratios of the aerosols were classified into two groups, depending on the sampling date. One group showed similar Pb isotopic ratios with those of the source related materials, suggesting that the contribution of the regional sources to the aerosols was very large. The other showed different Pb isotopic ratios from those of the regional sources and relatively high Pb isotopic ratios compared to the ratios of the first group. The results suggest that in the continental Asia there seems to be a long range transport of Pb with high ratios in desert sands, which are carried by northwest seasonal winds. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

13.
The isotope ratios 207Pb:206Pb and 208Pb: 206Pb are measured by means of inductively coupled plasma mass spectrometry (ICP-MS) for monazite minerals and commercial rare earth compounds and are evaluated with respect to the initial composition of the minerals and the origin of the samples. The application of the isotopic fingerprint method is demonstrated.Dedicated to Professor Dr. Dieter Klockow on the occasion of his 60th birthday  相似文献   

14.
ICP-MS测定土壤中铅同位素比值及地域差异性比较   总被引:2,自引:0,他引:2  
建立用HNO_3-H_2O_2-HF体系微波消解前处理样品,利用电感耦合等离子体质谱测定土壤中铅同住素比值的方法,探讨并优化了影响测试结果的两种干扰因素.该方法中~(207)Pb/~(206)Pb和~(208)Pb/~(206)Pb的短期测量稳定性RSD分别达到0.12%和0.13%,长期测量的偏差分别在0.002和0.01以内,样品测量的最佳范围是10~40μg/L.采用标样-样品交叉法测定了湖南、湖北、云南、贵州、河南、福建、辽宁7个省的48个地区土壤中的铅同位素比值,结合聚类分析和主成分分析比较了各省土壤中同位素分布的差异,初步探讨了利用~(207)Pb/~(206)Pb和~(208)Pb/~(206)Pb比较烟叶产区的可能性.  相似文献   

15.
A new technique for stable lead (Pb) isotope extraction from seawater is established using Toyopearl AF-Chelate 650 M® resin (Tosoh Bioscience LLC). This new method is advantageous because it is semi-automated and relatively fast; in addition it introduces a relatively low blank by minimizing the volume of chemicals used in the extraction. Subsequent analyses by HR ICP-MS have a good relative external precision (2σ) of 3.5‰ for 206Pb/207Pb, while analyses by MC-ICP-MS have a better relative external precision of 0.6‰. However, Pb sample concentrations limit MC-ICP-MS analyses to 206Pb, 207Pb, and 208Pb. The method was validated by processing the common Pb isotope reference material NIST SRM-981 and several GEOTRACES intercalibration samples, followed by analyses by HR ICP-MS, all of which showed good agreement with previously reported values.  相似文献   

16.
研究了多接收器电感耦合等离子体质谱仪(MC-ICP MS)测定铅同位素比值时,影响测试结果准确度和精密度的主要因素及其优化过程。在优化条件下,10 h内连续30次测定4 ng/mL NIST SRM 981同位素标准溶液铅同位素比值,获得208Pb/206Pb、207Pb/206Pb和206Pb/204Pb相对标准偏差(RSDs)分别为0.005%、0.004%和0.054%。长期监测208Pb/206Pb、207Pb/206Pb和206Pb/204Pb,标准偏差(2SDs)分别为0.000 06、0.000 05和0.006 7。采用NEPTUNE MC-ICP MS法测定了低铅海洋碳酸盐样品中稳定铅的同位素比值,并对南海橙黄滨珊瑚(Porites lutea)和库氏砗磲(Tridacna gigas)进行了分析,得到全流程空白为8~10 pg,重复样误差优于0.1%。经0.50 mol/L HNO3洗脱之后,得到海南珊瑚样品中208Pb/206Pb、207Pb/206Pb的比值分别为2.086 2±0.001 5、0.849 90±0.001 47(n=16);海南砗磲样品中208Pb/206Pb、207Pb/206Pb的比值分别为2.116 9±0.004 2、0.864 81±0.001 62(n=9)。进一步考察了南海海洋碳酸盐中204Pb的同位素比值。分析结果表明,南海海洋碳酸盐中稳定铅同位素比值与中国气溶胶、珠江三角洲大气沉降、黄土及南海海底玄武岩等具有很好的相关性。方法适用于复杂基体高钙低铅的海洋碳酸盐样品中铅同位素比值的分析。  相似文献   

17.
Abstract

Experimental plots have been set up at two Research Stations in upland areas of Scotland with the intention of characterising environmental samples using lead isotopic composition which varies according to the original source of the lead. Thermal ionisation mass spectrometry (TIMS) was used to measure lead isotope ratios with high precision. The 206Pb/207Pb ratios in rainwater were in the range from 1.101 to 1.153 over a period of two years at the two sites. Low ratios were associated with the very low ratios found in Britain in petrol additives during that period whereas higher ratios indicated a larger component derived from industrial sources at the Hartwood site. The 206Pb/207Pb ratios in the surface (0–2.5 cm) soil from a roadside plot were low (1.1126 and 1.1159 in 1989 and 1990, respectively) but the ratios in surface soils in plots distant from the road were considerably higher. Whereas the lead in roadside soil had a 206Pb/207Pb ratio indicating its source to be predominantly in recent petrol lead, there were significant components from other sources in the soils away from the road. The washing of grass samples resulted in no significant change in the lead isotope ratios. The lead isotope ratios measured in grass samples reflect the isotopic character of current atmospheric inputs but those in surface soil samples are an integrated record of atmospheric deposition over a long period of time. An undisturbed plot under a tree canopy had high concentrations of lead in the surface soil and low 206Pb/207Pb ratios. The ratios in fallen leaves on this plot were slightly but significantly lower than those in the grass grown on the plot. It would appear that the tree canopy is effective at scavenging lead carried in the atmosphere.  相似文献   

18.
Lead isotopic studies in soils provide an efficient tool for tracing the sources of lead pollution. Five different extraction/digestion techniques (0.05 M EDTA, 0.5 M HNO3, 2 M HNO3, aqua regia, total digestion) were used for lead isotopic composition (206Pb/207Pb) determination in three forest soil profiles with different kinds of prevailing Pb contamination (unpolluted area, smelting area and vicinity of a motorway). The results obtained showed that all extraction/digestion methods used for the determination of 206Pb/207Pb ratios in surface horizons containing high organic matter contents gave statistically identical values (according to the Tukey test). In mineral soil horizons, differences between the individual extraction/digestion methods could be observed (the lowest 206Pb/207Pb ratios were obtained from EDTA extracts, corresponding to weakly bound anthropogenic lead, and the highest 206Pb/207Pb ratios were obtained from total digestion). The combination of total digestion and EDTA extraction (labile lead fraction) seems to be the optimal combination for 206Pb/207Pb ratio determination and optimal result interpretation.  相似文献   

19.
This work explores the performance of laser ablation—inductively coupled plasma mass spectrometry using different types of single-collector devices (sector field and time-of-flight instrumentation) for lead isotopic analysis of bronze coins, minted in the ancient city of Bilbilis. The aim of the study was achieving sufficient discrimination power to reveal similarities and differences for coins originating from different historical periods, and to obtain information on the possible source of the lead ores used in their production, while restricting the damage inflicted to the samples such that it is not visible to the naked eye.It was found that satisfactory results (RSD in the 0.15-0.30% range for 207Pb/206Pb and 208Pb/206Pb ratios) could be finally obtained, despite the noisy nature of signals generated upon ablation of the highly inhomogeneous coins, by means of a methodology based on: (a) selection of the line profiling ablation mode; (b) use of a dual pass spray chamber that permits the simultaneous introduction of a solution (containing thallium of known isotopic composition), thus resulting in a wet plasma that showed an increased robustness towards matrix effects and (c) detection using a TOF-ICPMS unit, which proved to be much better suited to deal with the transient signals obtained, while being also sufficiently sensitive to obtain good counting statistics, owing to the high lead level (average around 5%) present in the samples. Moreover, under these conditions, the simultaneous aspiration of the thallium spike permitted accurate correction for mass discrimination, such that it was not necessary to use external matrix-matched standards for calibration.  相似文献   

20.
E. Marguí  I. Queralt 《Talanta》2007,73(4):700-709
A methodology for a precise and accurate determination of lead isotope ratios in mining wastes by inductively coupled plasma quadrupole-based mass spectrometry (ICP-QMS) has been developed. The study of instrumental bias factors led to the conclusion that internal correction to compensate mass discrimination is required as well as an interference equation correction when Hg is present. The proposed method has been applied to determine lead isotope ratios in several mining wastes, soils and sediments collected at three mining areas in Spain (Aran Valley, Cartagena and Osor).Statistical analysis highlights that 206Pb/207Pb and 208Pb/207Pb lead isotope ratios can be used as a fingerprint of mining waste origin which is related to the geological age of the lead ore.On the other hand, no statistically significant isotopic differences between original ore samples (galena) and processing wastes within a mining district were found, corroborating a unique lead source. Moreover, the lead isotopic composition of soil and sediment samples collected at the studied mining areas is close to that determined in the mining tailings from the same areas, suggesting that the unusual high content of lead in these samples is derived from mining activities rather than from other lead sources.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号