首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination with an aqueous solution of 6 mmol L–1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 σ) achieved by the HPLC-FAAS system was 1 mg L–1 of selenium (100 μL injections) for each of the four selenium species. More powerful selenium detection was achieved using an ELAN 5000 ICP-MS instrument. Selenium was measured at m/z = 82. The ICP-MS signal intensity was enhanced by a factor of 3–4 after addition of 3% methanol to the chromatographic mobile phase and by using an increased plasma power input of 1300 W. The limit of detection achieved under these conditions was 1 μg L–1 (100 μL injections). The HPLC-ICP-MS system was used for selenium speciation of selenite and selenate in aqueous solutions during a BCR certification exercise and for selenium speciation in the certified reference material, BCR No. 402 White Clover. Extraction experiments revealed that the selenium species in the biological material were extractable only in the presence of water in the extraction medium. The results indicated that selenate and a compound of unknown identity U were present in the plant sample. Received: 4 September 1996 / Accepted: 12 December 1996  相似文献   

2.
An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination with an aqueous solution of 6 mmol L–1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 σ) achieved by the HPLC-FAAS system was 1 mg L–1 of selenium (100 μL injections) for each of the four selenium species. More powerful selenium detection was achieved using an ELAN 5000 ICP-MS instrument. Selenium was measured at m/z = 82. The ICP-MS signal intensity was enhanced by a factor of 3–4 after addition of 3% methanol to the chromatographic mobile phase and by using an increased plasma power input of 1300 W. The limit of detection achieved under these conditions was 1 μg L–1 (100 μL injections). The HPLC-ICP-MS system was used for selenium speciation of selenite and selenate in aqueous solutions during a BCR certification exercise and for selenium speciation in the certified reference material, BCR No. 402 White Clover. Extraction experiments revealed that the selenium species in the biological material were extractable only in the presence of water in the extraction medium. The results indicated that selenate and a compound of unknown identity U were present in the plant sample.  相似文献   

3.
For selenium speciation analysis, the hyphenation of chromatographic separation with element-specific detection has proved a useful technique. A powerful separation system, which is capable of resolving several biologically and environmentally important selenium compounds in a single column, is greatly needed. However, that has been difficult to achieve. In this paper eight selenium compounds, namely, selenite [Se(IV)], selenate [Se(VI)], selenocystine (SeCys), selenourea (SeUr), selenomethionine (SeMet), selenoethionine (SeEt), selenocystamine (SeCM) and trimethylselenonium ion (TMSe+), were separated by using mixed ion-pair reagents containing 2.5 mM sodium 1-butanesulfonate and 8 mM tetramethylammonium hydroxide as a mobile phase. The separation of these anionic, cationic and neutral organic selenium compounds on a LiChrosorb RP18 reversed-phase column took only 18 min at a flow-rate of 1.0 ml/min with isocratic elution, and baseline separation among the six organic Se compounds was achieved. Inductively coupled plasma mass spectrometry (ICP-MS) was employed as element-specific detection. A comparison of ICP-MS signal intensity obtained with a Barbington-type nebulizer and with an ultrasonic nebulizer (USN) was made. Different signal enhancement factors were observed for the various selenium compounds when a USN was used. The speciation technique was successfully applied to the study on chemical forms of selenium in a selenium nutritional supplement. Selenomethionine was found to be the predominant constituent of selenium in the supplement.  相似文献   

4.
Zheng J  Shibata Y  Furuta N 《Talanta》2003,59(1):27-36
Analytical methods for the speciation of nine selenium species (selenite, selenate, selenourea, trimethylselenonium ion, selenocystamine, selenocystine, selenocysteine, selenomethionine and selenoethionine) that are commonly encountered in biological and environmental samples were developed. Good separation was achieved by either a mixed ion-pair reversed phase chromatography (LiChrosorb RP 18, 2.5 mM 1-butanesulfonate-8 mM tetramethylammonium hydroxide-4 mM malonic acid-0.05% methanol, pH 4.5) or a conventional ion-pair reversed phase chromatography (Inertsil ODS, 10 mM tetraethylammonium hydroxide-4.5 mM malonic acid, pH 6.8) with on-line ICP-MS detection. Using a 20-μl sample loop, low detection limits around 1 ng ml−1 expressed as Se were achieved for the examined selenium species. The methods were used for the determination of selenoamino acids in a selenium nutritional supplement. The developed methods were found to be rather robust. No alteration of the separation was observed when the protease enzymatic extracts were analyzed without dilution. Both water extracts and enzymatic extracts were chromatographed first with the mixed ion-pair reversed phase chromatographic system, then the major chromatographic peaks were collected and analyzed by the second ion-pair reversed phase chromatographic system for a further verification of their identity. Selenomethionine was found to be the major selenium species in the supplement. A major unknown species, probably Se-adenosylhomocysteine, could be determined in the extracts. A biological reference material, Dolt-2, was also examined for the selenoamino acids. Selenocystine and selenomethionine could be detected in its enzymatic extract, suggesting that Dolt-2 may be used as a reference material for the identification of selenoamino acids in biological and environmental samples. As selenoethionine does not occur naturally in the investigated samples, it is added as an internal standard in this study.  相似文献   

5.
Strong cation-exchange chromatography (SCX-HPLC) was used in conjunction with inductively coupled plasma mass spectrometry (ICP-MS) to investigate cationic selenium species present in leaf extract of wild-type Brassica juncea supplemented with selenite. Total amount of Se accumulated by the leaves was found to be 352 microg g(-1). Cation-exchange solid-phase extraction (SCX-SPE) was used to pre-concentrate the cationic species present in the leaf extract. Methylselenomethionine (MeSeMet) and dimethylselenoniumproprionate (DMSeP) were synthesized and characterized by electrospray quadrupole time-of-flight MS (ESI-QTOF-MS). Laboratory synthesized and commercially available standards were used in chromatographic studies to identify the Se species in the leaf extract through retention time comparisons and standard addition method. Major cationic selenium species identified in the present study were MeSeMet and methylselenocysteine (MeSeCys) while selenomethionine (SeMet) was found in minor quantities.  相似文献   

6.
There is considerable evidence that toxicity and physiological behavior of arsenic depends on its chemical forms. Arsenic speciation became therefore the subject of increasing interest in recent years. A sensitive method for the determination of arsenic species has been developed. The proposed procedure involves the use of high-performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICP-MS). Six arsenic compounds were separated by anion-exchange chromatography with isocratic elution using tartaric acid as mobile phase with an elution order: arsenocholine, arsenobetaine, dimethylarsinic acid, methylarsonic acid, arsenous acid and arsenic acid. The chromatographic parameters affecting the separation of the arsenic species were optimized. Analytical characterization of the method has been realized with standard solutions. The detection limits for six arsenic compounds were from 0.04 to 0.6 g/L as As element. The repeatability (expressed by R.S.D) was better than 7% for all investigated compounds. The HPLC-ICP-MS system was successfully applied to the determination of arsenic compounds in environmental and biological samples in g/L level.  相似文献   

7.
High-performance liquid chromatography (HPLC) combined with inductively coupled plasma mass spectrometry (ICPMS) has been studied as a means for the detection of carbon to provide a 'universal' method for detecting organic compounds in chromatographic eluents. Carbon is particularly difficult to ionise and the amount of carbon present in normal chromatographic systems leads to high backgrounds, making detection a challenge. Novel separation approaches were therefore employed, using either entirely aqueous eluents (at temperatures of 60 and 160 degrees C, dependent on the column used) to eliminate the organic modifier completely, or isotopically enriched solvents. For the aqueous eluents, detection limits for sulphanilamide were found to be 2.26 microg, corresponding to 1.13 micromol (0.47 micromol of carbon), injected on a conventional 4.6 mm i.d. column. The use of a narrow bore column with highly isotopically enriched 12C-methanol (99.95 atom%) as organic modifier for the mobile phase enabled the detection of 86 micromol for 13C-triple-labelled caffeine and 79 micromol for 13C-double-labelled phenacetin. The sensitive detection of 12C-compounds with 13C-enriched methanol as organic modifier proved impractical due to a lower level of isotopic enrichment (99 atom%) of this solvent, with the residual 12C-methanol resulting in significant interference.  相似文献   

8.
A bonded phase capillary column containing macrocyclic polyamine, [28]ane-N6O2 functional groups was used for the electrophoretic separation of arsenic, chromium and selenium species. A simple device interfacing this capillary electrochromatography (CEC) systems to an inductively coupled plasma mass spectrometer (ICPMS) is described. The dimension of the capillary column was 160 cm×100 μm i.d. To accommodate this electrophoretic separation, an auxiliary capillary was used with nitric acid (0.05 M) as makeup liquid. With the electrokinetic method at –20 kV, 20 s and a nebulizer gas flow rate of 1 l min−1, the sample injected was analyzed with an applied potential of −20 kV. The background electrolyte buffer for the separation of CrO42−–Cr3+ was phosphate (20 mM, pH 6.5). That for HAsO42−–Ph4As+ was pyromellitate (20 mM, pH 6.0) and for SeO42−–SeO32− was acetate (20 mM, pH 6.0). The role of the buffer’s anion was also discussed. The separation efficiency of the bonded phase was compared with the bare fused silica. Concentration detection limits for these metal ions were in the low ppb range. In addition, the matrix effect of the established system with the bonded phase was found smaller than that with the bare fused silica.  相似文献   

9.
微波辅助萃取-液质联用技术测底泥砷、硒的化学形态   总被引:3,自引:0,他引:3  
建立了用反相离子对色谱和电感耦合等离子体质谱的联用技术同时测定As(Ⅲ)、 As(Ⅴ)、 MMA、 DMA、 Se(Ⅳ)、 Se(Ⅵ)、 SeMet和SeCys的砷、硒化学形态分析方法. 分别从流动相pH值、离子对试剂的浓度、甲醇量和流速4个方面进行了分离测定条件的优化. 利用碰撞池技术(CCT)较好地解决了^40Ar^35Cl^+复合离子对^75As的干扰, 并使^80Se的测定成为可能, 有效地提高了灵敏度. 将该方法应用于上海市苏州河底泥样品的微波辅助萃取液的形态分析中, 砷和硒的检出限分别达到0.4~1.3 和0.5~1.9 μg/L.  相似文献   

10.
Wang B  Xie L  Lin Y  Yan Z  Wang L 《色谱》2011,29(3):223-227
建立了高效液相色谱-电感耦合等离子体质谱(HPLC-ICP-MS)联用检测硒酸盐(SeVI)、亚硒酸盐(SeIV)、硒代蛋氨酸(SeMet)、硒代胱氨酸(SeCys2)和硒代乙硫氨酸(SeEt)的方法。采用Hamilton PRP X-100色谱柱(250 mm×4.6 mm, 5 μm),使用5 mmol/L的柠檬酸溶液(pH 4.5)作为流动相,电感耦合等离子体质谱(ICP-MS)检测,在21 min内可以完全分离5种硒形态。各形态硒的线性相关系数均大于0.9995, SeVI、SeIV、SeMet、SeCys2、SeEt的检出限分别为0.4、0.4、5.6、0.9、1.2 μg/L。探讨了不同提取方法的提取效果,鲜蘑菇和猪肉样品加标回收实验表明,对水溶性良好的无机硒和硒代蛋氨酸而言,采用柠檬酸溶液提取的效果非常好,SeIV和SeVI的回收率均在100%左右,SeMet的回收率为85.0%~95.3%;用蛋白酶水解提取,SeCys2和SeEt的回收率为79.9%~91.5%。该方法可完全满足食品中这5种硒形态的准确定量分析。  相似文献   

11.
An ion chromatography-inductively coupled plasma mass spectrometric (IC-ICP-MS) method for the speciation of selenium and tellurium compounds namely selenite [Se(IV)], selenate [Se(VI)], Se-methylselenocysteine (MeSeCys), selenomethione (SeMet), tellurite [Te(IV)] and tellurate [Te(VI)] is described. Chromatographic separation is performed in gradient elution mode using 0.5 mmol L(-1) ammonium citrate in 2% methanol (pH 3.7) and 20 mmol L(-1) ammonium citrate in 2% methanol (pH 8.0). The analyses are carried out using dynamic reaction cell (DRC) ICP-MS. The DRC conditions have also been optimized to obtain interference free measurements of (78)Se(+) and (80)Se(+) which are otherwise interfered by (38)Ar(40)Ar(+) and (40)Ar(40)Ar(+), respectively. The detection limits of the procedure are in the range 0.01-0.03 ng Se mL(-1) and 0.01-0.08 ng Te mL(-1), respectively. The accuracy of the method has been verified by comparing the sum of the concentrations of individual species obtained by the present procedure with the total concentration of the elements in two NIST SRMs Whole Milk Powder RM 8435 and Rice Flour SRM 1568a. The selenium and tellurium species are extracted from milk powder and rice flour samples by using Protease XIV at 70 degrees C on a water bath for 30 min.  相似文献   

12.
Pine nuts (Pinus pinea) from different geographical origin in Spain and Portugal have been investigated concerning total element content and metal-biomolecules size distribution patterns Mn, Zn, Ni and Cu. All the studied metals were at the highest concentration in pine nuts from Faro and at the lowest from Catalu?a. The most abundant element in samples was Mn at concentrations in the range of 26 microg g(-1) (Catalu?a) to 559 microg g(-1) (Faro). Zn was also present at high concentration in samples, from 25 microg g(-1) (Catalu?a) to 113 microg g(-1) (Faro). To a deeper insight to obtain classification rules for samples, pine nuts were analyzed by size-exclusion chromatography (SEC) with UV detection and inductively coupled plasma mass spectrometry (ICP-MS). Two columns were used covering the molecular weigh range from < 10 to 70 kDa that allowed the discrimination of the studied samples. Data reveal that the most differential UV-profile with low molecular weight (LMW) column was obtained with pine nuts from Huelva. This column allows good discrimination in the range of 2126-1352 Da in which a lot of peaks can be used to differentiate samples. The UV profiles obtained with the high molecular weight (HMW) column allows a poorer differentiation of samples, but pine nuts from Huelva, Castilla and Madrid are clearly distinguished to the others. In relation to fractionation patterns of metals, Mn allows a good discrimination between samples (LMW column), Cu was the only one associated to fractions at MW > 70 kDa in sample from Cádiz, and profiles of Ni and Zn are clearly different in terms of abundance of peaks. All these chromatographic profiles for elements give valuable information about the geographical origin of the studied samples and the differences found are discussed in this work.  相似文献   

13.
An on-line isotope dilution (ID) method in combination with the coupling of size-exclusion high-performance liquid chromatography (SE-HPLC) to an axial inductively coupled plasma time-of-flight mass spectrometer (ICP-TOFMS) was applied to the quantitative speciation of Cu, Zn and Cd in carp and eel cytosols. Quantitative information on the distribution of essential and toxic metals between the different molecular weight fractions in kidney cytosols of control and Cd exposed carp was obtained with species-unspecific spiking by post-column addition of the enriched isotopes 65Cu, 67Zn and 106Cd. The isotope ratios 63Cu/65Cu, 64Zn/67Zn and 114Cd/106Cd, were monitored by ICP-TOFMS in transient signal mode. The determination of the total cytosolic element concentration was performed by flow injection conventional nebulization ICP-TOFMS. Speciation differences were encountered between control and Cd-stressed carp, indicating that quantitative speciation studies might be useful for ecotoxicological and biomonitoring purposes. Application of this methodology to quantitation of metals associated with metallothioneins (MT) in European eel, sampled at three different sites in Flanders, Belgium was also addressed. A significant increase of the amount of Cd, Cu and Zn bound to hepatic MT was observed with the increase of the total metal and MT concentrations of hepatic eel tissue.  相似文献   

14.
A method based on ion chromatography (IC) and inductively coupled plasma MS (ICP-MS) was developed for the speciation of arsenic in water and soil extracts. An anion-exchange column (G3154A/101) was used to separate As(III), As(V), dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) with excellent resolution. Various ammonium salts, including NH4H2PO4, (NH4)2HPO4, (NH4)2CO3, and NH4HCO3, were examined as eluents to reduce matrix interference from chloride and to solve clogging problems. The best arsenic speciation was obtained within 9 min with excellent resolution and without interference from high chloride concentrations using an eluent containing 7.5 mM (NH4)2HPO4 at pH 7.9. The detection limits for the target arsenic species ranged from 0.1 to 0.4 microg/L with direct injection of sample without matrix elimination. The proposed method was effectively demonstrated by determining arsenic species in contaminated waters and soils of Bangladesh.  相似文献   

15.
Five arsenic species, trimethylarsine oxide, dimethylarsenic acid, monomethylarsonic acid, arsenobetaine and sodium arsenite, in urine were analysed by inductively coupled plasma mass spectrometry with ion chromatography (IC ICP MS). Since the toxicities of different arsenic compounds are different, speciation of arsenic compounds is very important in the investigation of metabolisms. In this paper, we applied ion chromatography (IC) as a separation device and inductively coupled plasma mass spectrometry (ICP MS) as a detection device. For separation of the five arsenic compounds, an anion-exchange column and, as mobile phase, tartaric acid were used. The eluent from the IC column was introduced directly into the nebulizer of the ICP MS and analysed at 75 amu. Detection limits were from 4 to 9 pg as arsenic.  相似文献   

16.
We describe a new method for separating the organic and inorganic selenocompounds methaneseleninic acid, selenite, selenate, methylselenocysteine, selenocystine as well as both selenomethionine and its oxidized form. The separation is performed on a Hamilton PRP-X100 column. According to the literature, the oxidized form of selenomethionine—which is easily formed—is eluted close to the dead volume when this column is used. The choice of parahydroxybenzoic acid as mobile phase enabled us to elute all of these species after this oxidized form, resulting in better identification and quantification. The factors determining separation (eluent concentration, pH, gradient) were optimized via an experimental design. Application of the method to yeast and commercial tablets showed that the principal Se compound present was selenomethionine, which was also present in its oxidized form.  相似文献   

17.
Separation techniques coupled to inductively coupled plasma mass spectrometry (ICP-MS) is reviewed. ICP-MS technique is described briefly. Coupling of the different separation techniques are described, together with the most common applications used for each technique that has been described in the literature. An overview for the future of separation techniques coupled to ICP-MS with regard to elemental speciation is discussed.  相似文献   

18.
The separation and detection of volatile organometallic compounds containing tin, iron, and nickel has been achieved using capillary GC–inductively coupled plasma–mass spectrometry (capillary GC-ICP-MS). Detection limits range from 3.0 to 7.0 pg/s. The presence of volatile organotin compounds in a harbor sediment has been confirmed. The retention range of the organometallic compounds analyzed by capillary GC-ICP-MS has been extended considerably beyond that possible in earlier studies (retention indices up to 3400).  相似文献   

19.
A simple flow injection on-line dilution procedure with detection by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of copper, zinc, arsenic, lead, selenium, nickel and molybdenum in human urine. Matrix effects were minimized by employing a dilution factor of 16.5 with on-line standard addition, and (103)Rh was used as internal standard to compensate for signal fluctuation. The procedure was validated by the analysis of two standard reference materials SRM 2670 (NIST) and Seronormtrade mark Trace Elements in Urine. Recovery experiments were performed by spiking the reference materials as well as artificial urine. The detection limits (mug l(-1)) were 0.12,0.96,0.30,0.09,0.45,0.08,0.09, and the precisions (RSD,%) were 2.6,2.3,3.0,3.7,3.7,4.9,2.8 for Cu, Zn, As, Pb, Se, Ni and Mo, respectively. The procedure was applied to the analysis of 41 human urine samples. No correlations between the concentrations of the elements were observed.  相似文献   

20.
Summary An ICP-MS detector in combination with HPLC has been evaluated for the analysis of six arsenic compounds. The influence of the presence of an organic modifier in the mobile phase on arsenic response and the quality parameters of the analysis are discussed. Detection limits for arsenic species under study range from 10 to 30 pg. The determination of arsenic compounds in solutions simulating fish or sediment extracts has been used to demonstrate the applicability of this technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号