首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
将辣根过氧化物酶(HRP)通过纳米技术和自组装技术固定于电极表面,制得了酶修饰电极.纳米金与HRP形成了静电复合物并高效地保持了HRP的生物活性,以对苯二酚作为电子媒介体,差示脉冲伏安法(DPV)研究生物酶电极测定H2O2的线性范围为5.0×10-6~1.0×10-3 mol/L,检测限为2.5×10-6 mol/L,线性方程为△I=0.34765+4.05553CH2O2(mM).酶电极的表观米氏常数(K(app))为0.0675 mmol/L.实验同时证明该生物酶电极具有良好的稳定性和使用寿命.  相似文献   

2.
Tang N  Zheng J  Sheng Q  Zhang H  Liu R 《The Analyst》2011,136(4):781-786
A novel H(2)O(2) sensor based on enzymatically induced deposition of electroactive polyaniline (PANI) at a horseradish peroxide (HRP)/aligned single-wall carbon nanotubes (SWCNTs) modified Au electrode is fabricated, and its electrochemical behaviors are investigated. Electrochemical impedance spectroscopy of the sensor confirmed the formation of PANI on SWCNTs through the HRP catalytic reaction. Cyclic voltammograms of PANI/HRP/SWCNTs modified Au electrodes showed a pair of well-defined redox peaks of PANI with reduction peak potentials of 0.211 and oxidation peak potentials of 0.293 V in 0.1 M HOAc-NaOAc (pH 4.3) solution. The oxidation peak current response of PANI is linearly related to H(2)O(2) concentration from 2.5 μM to 50.0 μM with a correlation coefficient of 0.9923 and a sensitivity of 200 μA mM(-1). The detection limit is determined to be 0.9 μM with a signal-to-noise ratio of 3. Thus, the synergistic performance of the enzyme, the highly efficient polymerization of PANI, and the templated deposition of SWCNTs provided an extensive platform for the design of novel electrochemical biosensors.  相似文献   

3.
Chen X  Li C  Liu Y  Du Z  Xu S  Li L  Zhang M  Wang T 《Talanta》2008,77(1):37-41
Colloidal carbon microspheres (CMS) are dispersed in chitosan (CHIT) solution to form an organic-inorganic hybrid with excellent micro-environment for the immobilization of biomolecules. A novel amperometric biosensor for the determination of hydrogen peroxide (H(2)O(2)) has been constructed by entrapping horseradish peroxidase (HRP) in as-synthesized CMS/CHIT hybrid. The modification of glassy carbon electrode is made by a simple solution-evaporation method. The electrochemical properties of the biosensor are characterized in electrochemical methods. The proposed biosensor shows high sensitive determination and fast response to H(2)O(2) at -0.15 V. The constructed HRP/CHIT/CMS/GC electrode also exhibits a fine linear correlation with H(2)O(2) concentration. The calculated value of the apparent Michaelis-Menten constant, 2.33 mM, suggests that the HRP in CMS/CHIT hybrid keeps its native bioactivity and has high affinity for H(2)O(2).  相似文献   

4.
基于碳纳米管(CNTs)和硫堇(Th)的协同效应,将辣根过氧化物酶(HRP)通过戊二醛(GA)交联作用固定在硫堇(Th)/CNTs修饰电极上,构造了一种新型酶电极(HRP/GA-Th/CNTs/GC)。CNTs静电吸附正电荷的Th,而Th不仅可以促进电极和酶的氧化还原活性中心之间的电子传递,而且能使CNTs氨基(—NH2)功能化,从而利于HRP的固定。基于HRP/GA-Th/CNTs/GC电极的过氧化氢传感器具有较好的传感性能,且检出限低(0.3μmol.L-1)、响应时间短(5 s内)、抗干扰能力强。  相似文献   

5.
An amperometric horseradish peroxidase (HRP) inhibition biosensor has been substantially constructed by the help of N,N-dicyclohexylcarbodiimide (DCC), N-hydroxysuccinimide (NHS). The preparation steps and the biosensor response to phenylhydrazine were monitored by electrochemical impedance spectroscopy (EIS), cyclic voltammetry, and chronoamperometry. The proposed biosensor could be applied to determine phenylhydrazine in a 0.10 M phosphate buffer solution containing 1.2 mM hydroquinone and 0.50 mM H(2)O(2) by phenylhydrazine, inhibiting the catalytic activity of the HRP enzyme in the reduction of H(2)O(2). The system was optimized to realize a reliable determination of phenylhydrazine in the range of 2.5 x 10(-7) to 1.1 x 10(-6) M with a detection limit of 8.2 x 10(-8) M and a correlation coefficient of 0.999. The modified electrode displayed good reproducibility, sensitivity and stability for the determination of phenylhydrazine.  相似文献   

6.
制备了石墨烯-壳聚糖(GR-CS)纳米复合材料,并将之与辣根过氧化物酶(HRP)混合,构建了基于石墨烯-壳聚糖-辣根过氧化物酶的生物传感器(GR-CS-HRP/GC)。探针及循环伏安研究表明,该界面具有优异的电子传导能力、较大的比表面积和良好的生物相容性,对H2O2的还原显示出较好的电催化活性,在工作电位为-0.2 V,0.05 mol/L的磷酸盐缓冲盐溶液(PBS,pH 6.8)中,该酶传感器对过氧化氢响应灵敏度高,检测范围宽,测定H2O2的线性范围为5.0×10-7~2×10-3mol/L(相关系数为0.998)。检出限为2.0×10-7mol/L(S/N=3)。并且表现出良好的稳定性和高选择性。该电极用于实际样品中H2O2的测定,结果令人满意。  相似文献   

7.
Yamamoto K  Shi G  Zhou T  Xu F  Xu J  Kato T  Jin JY  Jin L 《The Analyst》2003,128(3):249-254
In this paper, multi-walled carbon nanotubes (MWCNTs) were successfully immobilized on the surface of a glassy carbon electrode by mixing with horse-radish peroxidase (HRP). The electrochemical behavior of H2O2 was also studied with the MWCNTs-HRP modified electrode as a working electrode. The MWCNTs-HRP modified electrode showed excellent response of reduction current for the determination of H2O2 at the potential of -300 mV (vs. Ag/AgCl). We assembled the MWCNTs-HRP modified electrode in a thin-layer flow cell and the H2O2 solution was continuously introduced into the cell with a syringe pump. We optimized the sensitivity of the H2O2 sensor by adjusting the working potential and the pH of the buffer solution. The peak current increased linearly with the concentration of H2O2 in the range 3.0 x 10(-7) to approximately 2.0 x 10(-4) mol L(-1). The detection limit is 1.0 x 10(-7) mol L(-1) (S/N = 3). The interferences from ascorbic acid, uric acid and other electroactive substances can be greatly excluded since the sensor can be operated at -300 mV. Stability and reproducibility of the MWCNTs-HRP chemically modified electrode were also studied in this paper. Fabricated with glucose and lactate oxidase, the MWCNTs-HRP electrode was also applied to prepare the on-line glucose and lactate biosensors because of the high sensitivity for the determination of H2O2.  相似文献   

8.
X Yang  J Bai  Y Wang  X Jiang  X He 《The Analyst》2012,137(18):4362-4367
Silver nanowires synthesized through a polyol process using polyvinylpyrrolidone as protection (PVP-AgNWs) were used as a new electrode material for constructing a sensor. Hydrogen peroxide (H(2)O(2)) and glucose were used as analytes to demonstrate the sensor performance of the PVP-AgNWs. It is found that the PVP-AgNWs-modified glassy carbon electrode (PVP-AgNWs/GCE) exhibits remarkable catalytic performance toward H(2)O(2) reduction. This sensor has a fast amperometric response time of less than 2 s and the catalytic current is linear over the concentration of H(2)O(2) ranging from 20 μM to 3.62 mM (R = 0.998) with a detection limit of 2.3 μM estimated on a signal-to-noise ratio of 3. A glucose biosensor was constructed by immobilizing glucose oxidase (GOD) onto the surface of the PVP-AgNWs/GCE. The resultant glucose biosensor can be used for glucose detection in human blood serum with a sensitivity of 15.86 μA mM(-1) cm(-2) and good selectivity and stability.  相似文献   

9.
Narang J  Chauhan N  Pundir CS 《The Analyst》2011,136(21):4460-4466
We describe the construction of a polyaniline (PANI), multiwalled carbon nanotubes (MWCNTs) and gold nanoparticles (AuNPs) modified Au electrode for determination of hydrogen peroxide without using peroxidase (HRP). The AuNPs/MWCNT/PANI composite film deposited on Au electrode was characterized by Scanning Electron Microscopy (SEM) and electrochemical methods. Cyclic voltammetric (CV) studies of the electrode at different stages of construction demonstrated that the modified electrode had enhanced electrochemical oxidation of H(2)O(2), which offers a number of attractive features to develop amperometric sensors based on split of H(2)O(2). The amperometric response to H(2)O(2) showed a linear relationship in the range from 3.0 μM to 600.0 μM with a detection limit of 0.3 μM (S/N = 3) and with high sensitivity of 3.3 mA μM(-1). The sensor gave accurate and satisfactory results, when employed for determination of H(2)O(2) in milk and urine.  相似文献   

10.
明胶固定辣根过氧化物酶制备H_2O_2传感器   总被引:2,自引:0,他引:2  
屈建莹  陈文静 《化学学报》2010,68(3):257-262
用明胶将辣根过氧化物酶(HRP)固定于多壁碳纳米管(MWNT)和茜素红(AR)修饰的玻碳(GC)电极上,制成HRP生物传感器(HRP/AR/MWNT/GC),然后在3%戊二醛(GA)中进行交联改性,以克服明胶膜易溶胀的缺点,并提高膜的稳定性.同时详细探讨了该传感器对H2O2的响应性能,并优化了实验条件.结果表明,该传感器对H2O2的线性响应范围为5.0×10-6~1.0×10-3mol/L,线性相关系数为0.9932,检出限为1.0×10-7mol/L,且放于4℃环境30d后,峰电流值约为原来的72.1%.该传感器响应快速,灵敏度高,且具有良好的重现性、稳定性及较长的使用寿命,具有潜在的应用价值.  相似文献   

11.
A sensitive hydrogen peroxidase (H2O2) amperometric sensor based on horseradish peroxidase (HRP)-labeled nano-Au colloids has been proposed. Nano-Au colloids were immobilized by the thiol group of cysteamine, which was associated with the carboxyl groups of poly(2,6-pyridinedicarboxylic acid) (PPDA). With the aid of the hydroquinone, the sensor displayed excellent electrocatalytical response to the reduction of H2O2. Compared with the non-Au-colloid modified electrode, i.e., PPDA/HRP, the Au-colloid modified electrode exhibited better performance characteristics, including stability, reproducibility, sensitivity and accuracy. The biosensor shows a linear response to H2O2 in the range of 3.0 x 10(-7) - 2 x 10(-3) M. The detection limit was 1.0 x 10(-7) M.  相似文献   

12.
A novel biosensor for hydrogen peroxide was prepared by immobilizing horseradish peroxidase (HPR) on newly synthesized dendritic silver/silicon dioxide nanocomposites, which were coated on a glassy carbon electrode. The modified electrode was characterized with XPS, SEM, and electrochemical methods. This biosensor showed a very fast amperometric response to hydrogen peroxide with a linear range from 0.7 to 120 μM, a limit of detection of 0.05 μM and a sensitivity of 1.02 mA mM?1 cm?2. The Michaelis‐Menten constant of the immobilized HRP was estimated to be 0.21 mM, indicating a high affinity of the HRP to H2O2 without loss of enzymatic activity. The preparation of the proposed biosensor was convenient, and it showed high sensitivity and good stability.  相似文献   

13.
《Electroanalysis》2005,17(12):1103-1111
Reagentless biosensors sensitive to hydrogen peroxide have been developed and compared. These biosensors are comprised of a carbon paste electrode modified with horseradish peroxidase (HRP) and one phenothiazine (methylene blue), one phenoxazine (meldola's blue) or one phenazine (phenazine methosulfate) dye adsorbed on silica gel modified with niobium oxide (SN). The enzyme was immobilized onto the graphite powder by cross‐linking with glutaraldehyde and mixing with one of the electron transfer mediators (dyes) adsorbed on SN. The amperometric response was based on the electrocatalytic properties of the dye to mediate electrons, which were generated in the enzymatic reaction of hydrogen peroxide under catalysis of HRP. The dependence on the biosensor response in terms of pH, buffer, HRP amounts and applied potential was investigated. The best results were found with a biosensor containing methylene blue dye showing an excellent operational stability (around 92% of the activity was maintained after 300 determinations). The proposed biosensor also presented good sensitivity (32.87 nA cm?2 μmol?1 L) allowing hydrogen peroxide quantification at levels down to 0.52×10?6 mol L?1 an optimum response at pH 6.8 and at a potential of ?50 mV (vs. SCE) and showing a wide linear response range (from 1 to 700 μmol L?1 for hydrogen peroxide).  相似文献   

14.
A new biosensor for the amperometric detection of hydrogen peroxide was developed based on the coimmobilization of horseradish peroxidase (HRP) and methylene blue on a beta-type zeolite modified glassy carbon electrode without the commonly used bovine serum albumin-glutaraldehyde. The intermolecular interaction between enzyme and zeolite matrix was investigated using FT-IR. The cyclic voltammetry and amperometric measurement demonstrated that methylene blue co-immobilized with HRP in this way displayed good stability and could efficiently transfer electrons between immobilized HRP and the electrode. The sensor responded rapidly to H2O2 in the linear range from 2.5 x 10(-6) to 4.0 x 10(-3) M with a detection limit of 0.3 microM. The sensor was stable in continuous operation.  相似文献   

15.
Poly(toluidine blue) nanowires (PTBNWs) with an average diameter of ca. 200 nm and length of ca. 5 μm were synthesized for the first time using a template‐directed electropolymerization strategy with a nanopore polycarbonate (PC) membrane template. Their morphological characterization was carried out by scanning electron microscopy (SEM) and transmission electron microscope (TEM). By electrochemical polymerization, horseradish peroxidase (HRP) was encapsulated in situ in PTBNWs (denoted as PTBNWs‐HRP) for potential biosensor applications. PTBNWs‐HRP was then modified on a glassy carbon (GC) electrode. In the system obtained, the PTBNWs served as an excellent redox mediator and exhibited high efficiency of electron transfer between the HRP and the GC electrode for the reduction of H2O2. The proposed electrode can be used as an excellent amperometric sensor for H2O2 at ?0.1 V with a linear response range covering from 1 μM to 28 mM, a detection limit of 1 μM (based on S/N=3) and a fast response time of less than 8 s.  相似文献   

16.
We report here the direct electron transfer of GOD and a novel glucose biosensor based on carbon-decorated ZnO(C–ZnO) nanowire array electrode. The C–ZnO nanowire array provides a novel platform for fast direct electrochemistry of GOD, and its based biosensor shows very high sensitivity and low detection limit. Based on the direct electrochemistry of horseradish peroxidase (HRP), the H2O2 biosensing application is further demonstrated using this new C–ZnO array architecture. The high conductivity of carbon and good electron transfer capability of ZnO nanowires, along with their low cost and biocompatibility make the C–ZnO nanowire array a promising platform for direct electrochemistry of enzymes and mediator-free enzymatic biosensors.  相似文献   

17.
Alpha-zirconium phosphate nanosheets (ZrPNS) derived via the delamination of layered alpha-zirconium phosphate (alpha-ZrP) have been proven to be efficient support matrixes for the immobilization of horseradish peroxidase (HRP). X-ray powder diffraction (XRD) results revealed that ZrPNS in HRP-ZrPNS film remained unorderly structured for the effect of HRP. Fourier transform infrared (FTIR) spectra results revealed that HRP remained the secondary structure in HRP-ZrPNS film. The direct electrochemistry of HRP was realized in HRP-ZrPNS film on a glassy carbon electrode (GCE), showing a pair of well-defined, nearly reversible cyclic voltammetry (CV) peaks for the HRP heme Fe(III)/Fe(II) redox couple. The average surface concentration (Gamma(*)) of electroactive HRP in HRP-ZrPNS film was estimated to be 1.35x10(-10) mol cm(-2), which indicated a high loading of enzyme molecules in HRP-ZrPNS film. Based on these, a third generation reagentless biosensor was constructed for the determination of hydrogen peroxide (H(2)O(2)). The response time of the biosensor was less than 3 s, and the linear response range of the biosensor for H(2)O(2) was from 1.3x10(-6) to 1.6x10(-2) M with a correlation coefficient of 0.9997.  相似文献   

18.
《Electroanalysis》2003,15(3):219-224
A novel hydrogen peroxide biosensor has been constructed based on the characteristics of the carbon nanotube. The multiwall carbon nanotube (MWNT) was used as a coimmobilization matrix to incorporate horseradish peroxidase (HRP) and electron transfer mediator methylene blue (MB) onto a glassy carbon electrode surface. Cyclic voltammetry and amperometric measurements were employed to demonstrate the feasibility of methylene blue as an electron carrier between the immobilized peroxidase and the surface of glassy carbon electrode. The amperometric response of this resulting biosensor to H2O2 shows a linear relation in the range from 4 μM to 2 mM. The detection limit was 1 μM when the signal to noise ratio is 3. The presence of dopamine and ascorbic acid hardly affects the sensitive determination of H2O2. This biosensor also possesses very good stability and reproducibility.  相似文献   

19.
《Electroanalysis》2004,16(9):730-735
Electrooxidation of thionine on screen‐printed carbon electrode gives rise to the modification of the surface with amino groups for the covalent immobilization of enzymes such as horseradish peroxidase (HRP). The biosensor was constructed using multilayer enzymes which covalently immobilized onto the surface of amino groups modified screen‐printed carbon electrode using glutaraldehyde as a bifunctional reagent. The multilayer assemble of HRP has been characterized with the cyclic voltammetry and the faradaic impedance spectroscopy. The H2O2 biosensor exhibited a fast response (2 s) and low detection limit (0.5 μM).  相似文献   

20.
A simple layer‐by‐layer (LBL) assembly strategy was established for constructing a novel reagentless biosensor based on a nanocomposite of methylene blue multiwalled carbon nanotubes (MB‐MWNTs). A nanocomposite of MB‐MWNTs was obtained by direct premixing and possessed good dispersion in barbital‐HCl buffer. Through electrostatic interactions, the nanocomposite of MB‐MWNTs could alternately be assembled with horseradish peroxidase (HRP) on the Au electrode modified with precursor films. UV/Vis spectra and scanning electron microscopy (SEM) were applied to reveal the formation of the nanocomposite of MB‐MWNTs. The LBL assembly process was also verified by electrochemical impedance spectroscopy (EIS). The MB is a well‐established mediator and efficiently facilitated the electron shuttle between the HRP and the electrode, as demonstrated by the cyclic voltammetry (CV) measurements. The as‐prepared reagentless biosensor exhibited a fast response for the determination of hydrogen peroxide (H2O2) and reached 95% of the steady‐state current within 3 s. It was found that the linear response range of the reagentless biosensor for H2O2 was from 4.0 μM to 3.78 mM with a detection limit of 1.0 μM and a sensitivity of 22.5 μA mM−1. The biosensor exhibited a high reproducibility and stability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号