首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Meropenem (MER) is widely used to treat complicated and serious infections. Therapeutic drug monitoring (TDM) provides a valid clinical tool to avoid suboptimal concentrations and dose–related adverse reactions. However, TDM seems to face challenges since the limited stability of MER in plasma makes transport difficult between clinics and laboratories. Dried plasma spot (DPS) sampling is an attractive but underutilized method for TDM that has the desired features of easy collection, storage, and transport, and overcomes known hematocrit (HCT) issues in dried blood spot (DBS) analysis. This study was designed to investigate a DPS–based liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for quantification of MER. The method was developed and validated for DPS and wet plasma samples. Calibration curves were linear (R2 > 0.995) over the concentration range of 0.5–50 µg/mL. Overall accuracy and precision did not exceed 15% and no significant matrix effect was observed. MER has been more stable in DPS than in wet plasma samples. A comparison of DPS and wet plasma concentrations was assessed in 32 patients treated with MER. The results showed that there was no significant difference between the two methods. So the DPS method developed in this study is appropriate and practical for the monitor of MER in the daily clinical laboratory practice.  相似文献   

2.
A bioanalytical method for the quantification of tacrolimus (TAC) on dried blood spots (DBS) using liquid chromatography, electrospray ionization coupled with tandem mass spectrometry (LC‐ESI‐MS/MS) was developed and validated. It involves solvent extraction of a punch disk of DBS followed by liquid–liquid extraction. The analyte and the internal standard (IS, ascomycin) were separated on a phenyl column using an isocratic mobile phase elution at a flow rate of 0.3 mL/min. The assay was linear from 1 to 80 ng/mL. The mean recovery of TAC was 76.6%. Intra‐assay, inter‐assay imprecision and biases were all less than 15%. TAC on DBS was stable for at least 10 days at room temperature, and at least 24 h at 50°C. A chromatographic effect of the filter paper (Whatman 903) was not detected. The volume of blood (15–50 μL) and hematocrit of blood (ranging from 23.2 to 48.6%) did not show a significant influence on detection of TAC concentration by DBS‐LC‐MS/MS. Fifty samples from patients were detected by both DBS‐LC‐MS/MS and microparticle enzyme‐linked immunoassay (MEIA). TAC concentrations measured by DBS‐LC‐MS/MS method tended to be lower than those by MEIA. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
Drug abuse still represents a global problem, and it is associated with an increased risk of diseases, injuries, and deaths. Cocaine (COC) and opiates are the most abused drugs and account for a significant number of fatalities. Therefore, it is important to develop methods capable of effectively identifying and quantifying these substances. The present study aims to evaluate the long-term stability of COC, ecgonine methylester (EME), benzoylecgonine (BEG), cocaethylene (COET), norcocaine (NCOC), morphine (MOR), codeine (COD) and 6-monoacetylmorphine (6-MAM) in oral fluid samples. The analytes of interest were isolated from the matrix (50 µL) using the dried saliva spots (DSS) sampling approach and were subsequently analyzed by gas chromatography coupled with tandem mass spectrometry (GC–MS/MS). The parameters that could influence the stability of the target compounds were studied, and these were storage temperature, light, use of preservatives (and respective concentrations), and time. The effects of each parameter were evaluated using the design of experiments (DOE) approach. The stability of the target analytes was improved when the DSS were stored at room temperature, in the presence of light and using 1% sodium fluoride. The best conditions were then adopted for the DSS storage and long-term stability was assessed. COD was only stable for 1 day, EME was stable for 3 days, COC, COET, NCOC and 6-MAM were stable for 7 days, MOR for 14 days and BEG remained stable throughout the study (136 days). This is the first study that evaluates the stability of these compounds in oral fluid samples after application in DSS cards, and optimizes the conditions in order to improve their stability.  相似文献   

4.
The use of blood spot collection cards is a simple way to obtain specimens for therapeutic drug monitoring, assessing adherence to medications and preventing toxicity in a clinical setting. A high‐throughput liquid chromatography–electrospray ionization mass spectrometric (LC‐ESI‐MS) method for determination of rifaximin on dried blood spots (DBS) was developed and validated. It involves solvent extraction of a punch of DBS followed by reversed‐phase LC on a monolithic column consisting of a silica rod with bimodal pore structure and detection by ESI‐MS. Rifampicin was used as an internal standard (IS). The run time was within 5.0 min with a very low back‐pressure at a flow rate of 0.5 mL/min. The assay was linear from 0.1 to 10 ng/mL. The mean recovery was 98.42%. The developed method is very simple, rapid and useful for clinical applications. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
A rapid and highly sensitive liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method for determination of dapiprazole on rat dried blood spots and urine was developed and validated. The chromatographic separation was achieved on a reverse‐phase C18 column (250 × 4.6 mm i.d., 5 µm), using 20 mm ammonium acetate (pH adjusted to 4.0 with acetic acid) and acetonitrile (80:20, v/v) as a mobile phase at 25 °C. LC‐MS detection was performed with selective ion monitoring using target ions at m/z 326 and m/z 306 for dapiprazole and mepiprazole used as internal standard, respectively. The calibration curve showed a good linearity in the concentration range of 1–3000 ng/mL. The effect of hematocrit on extraction of dapiprazole from DBS was evaluated. The mean recoveries of dapiprazole from DBS and urine were 93.88 and 90.29% respectively. The intra‐ and inter‐day precisions were <4.19% in DBS as well as urine. The limits of detection and quantification were 0.30 and 1.10 ng/mL in DBS and 0.45 and 1.50 ng/mL in urine samples, respectively. The method was validated as per US Food and Drug Administration guidelines and successfully applied to a pharmacokinetic study of dapiprazole in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
Duchenne muscular dystrophy (DMD) is an X-linked recessive disorder characterized by progressive muscle loss, leading to difficulties in movement. Mutations in the DMD gene that code for the protein dystrophin are responsible for the development of DMD disorder, where the synthesis of this protein is completely halted. Therefore, circulating dystrophin protein could be a promising biomarker of DMD disease. Current methods for diagnosing DMD have sensitivity, specificity, and reproducibility limitations. Herein, a quantitative liquid chromatography–tandem spectrometry (LC–MS/MS) technique in multiple reaction monitoring (MRM) mode was designed and validated for accurate dystrophin protein measurement in a dried blood spot (DBS). The method was successfully validated on the basis of international guidelines regarding calibration curves, precision, and accuracy. In addition, patients and healthy controls were used to test the amount of dystrophin protein circulating in DBS samples as a potential biomarker for DMD disorders. DMD patients were found to have considerably lower levels than controls. To the best of our knowledge, this is the first study to report dystrophin levels in DBS through LC–MS/MS as a diagnostic marker for DMD to the proposed MRM method, providing a highly specific and sensitive approach to dystrophin quantification in a DBS that can be applied in DMD screening.  相似文献   

7.
Fostamatinib is a prodrug of the active metabolite tamatinib, which is a spleen tyrosine kinase (Syk) inhibitor used in the treatment of primary chronic adult immune thrombocytopenia and rheumatoid arthritis. A highly sensitive, rapid, reliable, and green method was developed and validated using ultra-performance liquid chromatography and tandem mass spectrometry (UPLC–MS/MS) for quantification of tamatinib in rat plasma. Ibrutinib was used as internal standard and liquid–liquid extraction was applied using tert-butyl methyl ether. The analyte was separated on an AcquityTM CSH C18 (2.1 mm × 100 mm, 1.7 µm) column using mobile phase consisting of 10 mM ammonium acetate and acetonitrile (10:90) and the flow rate was 0.25 mL/min. Electrospray ionization (ESI) was carried out in positive mode. Quantitation of tamatinib and the IS was performed using multiple reaction monitoring mode with precursor-to-product transitions of m/z 471.1 > 122.0 and m/z 441.1 > 84.0, respectively. The calibration range was 0.1–1000.0 ng/mL and the linearity of the method was ≥0.997. The developed method greenness was investigated. All principal parameters for the method, including linearity, accuracy, precision, recovery, and stability, were within acceptable ranges. Tamatinib pharmacokinetic study in rats was successfully carried out using the developed method.  相似文献   

8.
A rapid and highly sensitive assay method has been developed and validated for the estimation of bicalutamide (BCL) on mouse dried blood spots (DBS) using liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the negative‐ion mode. The assay procedure involves a simple liquid extraction of BCL and tolbutamide (internal standard, IS) from mouse blood DBS cards using tert‐butyl methyl ether. Chromatographic separation was achieved with 5 mm ammonium acetate (pH 6.5)–acetonitrile (35:65, v/v) at a flow rate of 0.60 mL/min on an Atlantis dC18 column with a total run time 3.0 min. The MS/MS ion transitions monitored were 428.80 → 254.70 for BCL and 269.00 → 169.60 for IS. Method validation was performed as per regulatory guidelines. A linear response function was observed from 0.92 to 1911 ng/mL for BCL in mouse blood. The intra‐ and inter‐day precisions were in the ranges of 1.86–12.5 and 3.19–10.8%, respectively. This novel DBS method has been applied to a pharmacokinetic study in mice. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A high‐throughput liquid chromatography–electrospray ionization mass spectrometric (LC–ESI‐MS) method for screening of sirolimus on dried blood spots (DBS) was developed and validated. It involves solvent extraction of a punch of DBS followed by reversed‐phase LC on a relatively new monolithic column consisting of a silica rod with bimodal pore structure and detection by ESI‐MS. The run time was less than 3 min with a very low backpressure at a flow rate of 0.5 mL/min. The method can analyze more than 100 samples in an 8 h working day, including sample preparation. The assay was linear from 1 to 100 ng/mL. The mean recovery was 92.42%. The mean inter‐day and intra‐day precisions were 1.23 and 1.41%, respectively. The developed method is simple, rapid and useful for clinical applications. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
A simple, sensitive and rapid assay method has been developed and validated as per regulatory guidelines for the estimation of enasidenib on mouse dried blood spots (DBS) using liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The method employs liquid extraction of enasidenib from DBS disks of mouse whole blood followed by chromatographic separation using 0.2% formic acid–acetonitrile (25:75, v/v) at a flow rate of 1.0 mL/min on an Atlantis dC18 column with a total run time of 2.0 min. The MS/MS ion transitions monitored were m/z 474.0 → 267.1 for enasidenib and m/z 309.2 → 251.3 for the internal standard (warfarin). The assay was linear in the range of 1.01 – 3044 ng/mL. The within‐run and between‐run precisions were in the range of 3.18 – 9.06 and 4.66 – 8.69%, respectively. Stability studies showed that enasidenib was stable on DBS cards for 1 month. This novel method has been applied to analyze the DBS samples of enasidenib obtained from a pharmacokinetic study in mice.  相似文献   

11.
In the present study, a sensitive and fully validated bioanalytical high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for the quantitative determination of three newly synthesized carbonic anhydrases inhibitors (CAIs) with potential antitumor activity in human plasma. The analytes and the internal standard (IS) were extracted using 1.5 mL acetonitrile from only 450 µL aliquots of human plasma to achieve the desired protein precipitation. Chromatographic separations were achieved on Phenomenex Kinetex® C18 column (100 × 4.6 mm, 2.6 µm) using a binary gradient elution mode with a run time of less than 6 min. The mobile phase consisted of solvent (A): 0.1% formic acid in 50% methanol and solvent B: 0.1% formic acid in acetonitrile (30:70, v/v), pumped at a flow rate of 0.8 mL/min. Detection was employed using triple quadrupole tandem mass spectrometer (API 3500) equipped with an electrospray ionization (ESI) source in the positive ion mode. Multiple reaction monitoring (MRM) mode was selected for quantitation through monitoring the precursor-to-parent ion transition at m/z 291.9 → 173.0, m/z 396.9 → 225.1, m/z 388.9 → 217.0, and m/z 146.9 → 91.0 for AW-9a, WES-1, WES-2, and Coumarin (IS), respectively. Linearity was computed using the weighted least-squares linear regression method (1/x2) over a concentration range of 1–1000, 2.5–800, and 5–500 ng/mL for AW-9a, WES-1, and WES-2; respectively. The bioanalytical LC-MS/MS method was fully validated as per U.S. Food and Drug Administration (FDA) guidelines with all respect to linearity, accuracy, precision, carry-over, selectivity, dilution integrity, and stability. The proposed LC-MS/MS method was applied successfully for the determination of all investigated drugs in spiked human plasma with no significant matrix effect, which is a crucial cornerstone in further therapeutic drug monitoring of newly developed therapeutic agents.  相似文献   

12.
Gungha-tang (GHT), a traditional herbal medicine, consists of nine medicinal herbs (Cnidii Rhizoma, Pinelliae Tuber, Poria Sclerotium, Citri Unshius Pericarpium, Citri Unshius Pericarpium Immaturus, Aurantii Fructus Immaturus, Atracylodis Rhizoma Alba, Glycyrrhizae Radix et Rhizoma, and Zingiberis Rhizoma Recens). It has been used for various diseases caused by phlegm. This study aimed to develop and verify the simultaneous liquid chromatography–tandem mass spectrometry (LC–MS/MS) analysis method, using nine marker components (liquiritin apioside, neoeriocitrin, narirutin, naringin, hesperidin, neohesperidin, liquiritigenin, glycyrrhizin, and 6-shogaol) for quality control of GHT. LC–MS/MS analysis was conducted using a Waters TQ-XS system. All marker analytes were separated on a Waters Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm) using gradient elution with a distilled water solution (containing 5 mM ammonium formate and 0.1% [v/v] formic acid)–acetonitrile mobile phase. LC–MS/MS multiple reaction monitoring (MRM) analysis was carried out in negative and positive ion modes of an electrospray ionization source. The developed LC–MS/MS MRM method was validated by examining the linearity, limits of detection and quantification, recovery, and precision. LOD and LOQ values of nine markers were calculated as 0.02–8.33 ng/mL and 0.05–25.00 ng/mL. The recovery was determined to be 89.00–118.08% and precision was assessed with a coefficient of variation value of 1.74–8.64%. In the established LC–MS/MS MRM method, all markers in GHT samples were detected at 0.003–16.157 mg/g. Information gathered during the development and verification of the LC–MS/MS method will be useful for the quality assessment of GHT and other herbal medicines.  相似文献   

13.
14.
A simple and rapid high‐performance liquid chromatography–tandem mass spectrometric assay for determination of paclitaxel on rat dried blood spots was developed and validated. The extracted sample was chromatographed without further treatment using a reverse‐phase Oyster ODS3, 4.6 × 50 mm, 3 µm column with mass spectrometry detection. The mobile phase comprised of acetonitrile–water, 60:40 v/v, with a flow rate of 0.4 mL/min was used. The calibration was linear over the range 0.2–20 ng/mL. The limits of detection and quantification were 0.08 and 0.2 ng/mL, respectively. The intra‐ and inter‐day precision (CV%) and accuracy (relative error %) were less than 10 and 12%, respectively. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
In this study, a magnetic solid-phase extraction (MSPE) method coupled with High-Performance Liquid Chromatography Mass Spectrometry (HPLC–MS/MS) for the determination of illegal basic dyes in food samples was developed and validated. This method was based on Magnetic sulfonated reduced graphene oxide (M-S-RGO), which was sensitive and selective to analytes with structure of multiaromatic rings and negatively charged ions. Several factors affecting MSPE efficiency such as pH and adsorption time were optimized. Under the optimum conditions, the calibration curves exhibited good linearity, ranging from 5 to 60 µg/g with correlation coefficients >0.9950. The limits of detection of 16 basic dyes were in the range of 0.01–0.2 µg/L. The recoveries ranged from 70% to 110% with RSD% < 10%. The results indicate that M-S-RGO is an efficient and selective adsorbent for the extraction and cleanup of basic dyes. Due to the MSPE procedures, matrix effect and interference were eliminated in the analysis of HPLC–MS/MS without the matrix-matched standards. Thus, validation data showed that the proposed MSPE–HPLC–MS/MS method was rapid, efficient, selective, and sensitive for the determination of illegal basic dyes in foods.  相似文献   

16.
MP1 is a novel marinopyrrole analogue with activity in MYCN amplified neuroblastoma cell lines. A rapid, selective, and sensitive liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantitation of MP1 in mouse plasma. Analyte separation was achieved using a Waters Acquity UPLC®BEH C18 column (1.7 µm, 100 × 2.1 mm). Mobile phase consisted of 0.1% acetic acid in water (10%) and methanol (90%) at a total flow rate of 0.25 mL/min. The mass spectrometer was operated at unit resolution in the multiple reaction monitoring (MRM) mode, using precursor ion > product ion transitions of 324.10 > 168.30 m/z for MP1 and 411.95 > 224.15 m/z for PL-3. The MS/MS response was linear over the concentration range from 0.2–500 ng/mL for MP1, correlation coefficient (r2) of 0.988. Precision (% RSD) and accuracy (% bias) were within the acceptable limits as per FDA guidelines. MP1 was stable under storage and laboratory handling conditions. The validated method was successfully applied to assess the solubility, in-vitro metabolism, plasma protein binding, and bio-distribution studies of MP1.  相似文献   

17.
Ginseng (Panax quinquefolius), a popular herbal and nutritional supplement consumed worldwide, has been demonstrated to possess vital biological activities, which can be attributed to the presence of ginsenosides. However, the presence of ginsenosides in ginseng root residue, a by-product obtained during processing of ginseng beverage, remains unexplored. The objectives of this study were to develop a high-performance liquid chromatography-photodiode array detection-mass spectrometry (HPLC-DAD-ESI-MS) and an ultra-high-performance-liquid-chromatography-tandem mass spectrometry (UPLC-HRMS-MS/MS) method for the comparison of ginsenoside analysis in ginseng root residue. Results showed that by employing a Supelco Ascentis Express C18 column (150 × 4.6 mm ID, particle size 2.7 μm) and a gradient mobile phase of deionized water and acetonitrile with a flow rate at 1 mL/min and detection at 205 nm, a total of 10 ginsenosides, including internal standard saikosaponin A, were separated within 18 min and detected by HPLC-DAD-ESI-MS. Whereas with UPLC-HRMS-MS/MS, all the 10 ginsenosides were separated within six minutes by using an Acquity UPLC BEH C18 column (50 × 2.1 mm ID, particle size 1.7 μm, 130 Å) and a gradient mobile phase of ammonium acetate and acetonitrile with column temperature at 50 °C, flow rate at 0.4 mL/min and detection by selected reaction monitoring (SRM) mode. High accuracy and precision was shown, with limit of quantitation (LOQ) ranging from 0.2–1.9 μg/g for HPLC-DAD-ESI-MS and 0.269–6.640 ng/g for UPLC-HRMS-MS/MS. The contents of nine ginsenosides in the ginseng root residue ranged from <LOQ-26.39 mg/g by HPLC-DAD-ESI-MS and <LOQ-21.25 mg/g by UPLC-HRMS-MS/MS, with a total amount of 38.37 and 34.71 mg/g, respectively.  相似文献   

18.
Methylmalonic acid (MMA) and total homocysteine (tHCYS) concentrations are used to detect acquired and inborn errors of cobalamin (vitamin B12, Cbl) metabolism and to evaluate the effect of therapeutic interventions. Dried blood spot sampling offers a patient-friendly and easy alternative to plasma sampling. However, dried blood spot concentrations are not necessarily equal to plasma concentrations. Therefore, the objective of this work was to establish the relationship between MMA and tHYS dried blood spot and plasma concentrations to facilitate clinical implementation of dried blood spot sampling. MMA and tHCYS in both plasma and DBS were validated on ultra performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS). While position of the punch (in DBS) did affect tHCYS concentration, no influence of hematocrit (Ht) and blood volume on both MMA and tHCYS concentrations was observed. The plasma assay performed better than the DBS assay by most criteria. However, the DBS matrix was superior for tHCYS stability. Paired plasma and DBS samples were obtained from patients suspected for Cbl deficiency and from patients with a known inborn error of metabolism affecting MMA or tHCYS concentration. Based on the strong correlation of tHCYS in both matrices (y = 0.46 ± 1.12 (r2 = 0.91)), determination of tHCYS in plasma can be replaced by tHCYS in DBS. However, for MMA, a correlation in the higher (pathological) range of MMA exist, but no correlation was observed in the lower ranges. Therefore the added value of MMA concentrations in DBS is currently unknown and should be further investigated.  相似文献   

19.
Thiorphan, the active metabolite of racecadotril, can undergo oxidation in biological matrices such as blood and plasma. In bioanalysis, a general approach for the stabilization of such a molecule is to derivatize the thiol group to a more stable thioether, often requiring complex handling procedures at the clinical site. In this research, the concept of dried blood spot (DBS) on‐card derivatization was evaluated to stabilize thiorphan. DBS cards were in‐house pre‐treated with 2‐bromo‐3′‐methoxyacetophenone and left to dry prior to blood spotting. Thiorphan was shown to be effectively derivatized to thiorphan–methoxyacetophenone once applied on the in‐house pre‐treated cards. Thiorphan–methoxyacetophenone was extracted by soaking a 6 mm DBS punch in methanol containing the internal standard (thiorphan–methoxyacetophenone‐D5). Chromatographic separation was achieved on a Waters XBridge C18 column with a gradient elution of 5 m m NH4HCO3 and methanol in 2.5 min and detection by ESI(+)/MS/MS. A linear (weighted 1/x2) relationship was obtained over a concentration range of 5.00–600.00 ng/mL. The assay met regulatory guidelines acceptance criteria for sensitivity, selectivity, precision and accuracy, matrix effect, recovery, dilution integrity and multiple stability evaluations. The DBS on‐card derivatization has shown to be an easy and reliable alternative form of sample collection for the quantification of thiorphan. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
ARV-110, a novel proteolysis-targeting chimera (PROTAC), has been reported to show satisfactory safety and tolerability for prostate cancer therapy in phase I clinical trials. However, there is a lack of bioanalytical assays for ARV-110 determination in biological samples. In this study, we developed and validated an LC-MS/MS method for the quantitation of ARV-110 in rat and mouse plasma and applied it to pharmacokinetic studies. ARV-110 and pomalidomide (internal standard) were extracted from the plasma samples using the protein precipitation method. Sample separation was performed using a C18 column and a mobile phase of 0.1% formic acid in distilled water–0.1% formic acid in acetonitrile (30:70, v/v). Multiple reaction monitoring was used to quantify ARV-110 and pomalidomide with ion transitions at m/z 813.4 → 452.2 and 273.8 → 201.0, respectively. The developed method showed good linearity in the concentration range of 2–3000 ng/mL with acceptable accuracy, precision, matrix effect, process efficiency, and recovery. ARV-110 was stable in rat and mouse plasma under long-term storage, three freeze-thaw cycles, and in an autosampler, but unstable at room temperature and 37 °C. Furthermore, the elimination of ARV-110 via phase 1 metabolism in rat, mouse, and human hepatic microsomes was shown to be unlikely. Application of the developed method to pharmacokinetic studies revealed that the oral bioavailability of ARV-110 in rats and mice was moderate (23.83% and 37.89%, respectively). These pharmacokinetic findings are beneficial for future preclinical and clinical studies of ARV-110 and/or other PROTACs.  相似文献   