首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The applicability of a previously optimized method for the analysis of the US Environmental Protection Agency (EPA) regulations phenols, based on on-line solid-phase extraction coupled to liquid chromatography with mass spectrometric (MS) detection in different matrix loaded water samples is demonstrated. The comprehensive optimization of the mobile phase conditions and their influence on the ionization process in atmospheric pressure ionization is described in detail. In particular, MS detection of the weakly acidic phenols such as phenol, monochlorinated phenols and methylated phenols requires the absence of acidic mobile phase modifiers and buffers. Thus lower retention times and slight peak broadening of the more acidic dinitrophenols are obtained if the entire range of EPA phenols is analyzed within a single chromatographic run. The figures of merit for the method were determined and the applicability to real water samples was investigated. Limits of detection for phenols ranging from 40 to 280 ng l(-1) and relative standard deviations below 8% in SCAN mode are obtained for all phenols if only 10-ml river water samples with low dissolved organic carbon (DOC 5 mg C l(-1) concentrations are preconcentrated. The method was used to detect 2-nitrophenol and 4-nitrophenol in river water samples in the lower ng l(-1) range. The analysis of highly matrix-loaded samples (DOC 210 mg C l(-1)) requires a reduced enrichment volume resulting in decreased sensitivity. Still the method is capable of reaching excellent detection limits which demonstrates its excellent suitability for screening analysis.  相似文献   

2.
A simple, sensitive and rapid reversed-phase high-performance liquid chromatography (RP-HPLC) method is proposed for the analysis of some environmentally important phenols in water. The use of coumarin-6-sulphonyl chloride (C6SCl) as a fluorescence-labeling reagent has been investigated. The compound reacts with phenols within 20 min under mild conditions (ambient temperature, pH 9.0) to give sulphonates that can be separated by RP-HPLC employing fluorescence detection at lambda(ex) = 360 and lambda(em) = 460 nm. The optimum conditions for fluorescence, derivatization and chromatographic separation have been established and detection limits in the range 0.1-0.9 microg l(-1) were obtained for the studied compounds. The calibration curves were linear for the range 6-200 microg l(-1) for phenol, 3-200 microg l(-1) for 2-chlorophenol, 4-chlorophenol and 2,3,5-trichlorophenol and for the range of 3-100 microg l(-1) for 2,3-dichlorophenol and 3,5-dichlorophenol. The practical applicability of the method to environmental samples was demonstrated by analyzing drinking and industrial water samples spiked with the phenolic compounds.  相似文献   

3.
利用相转换法制备了聚酰亚胺吸附萃取搅拌棒,用5种有机酚作为评价标样,并与现有商品化吸附萃取搅拌棒进行比较。优化了萃取搅拌速度、溶液离子强度、萃取温度、萃取时间以及热解析温度和时间。在最佳实验条件下,100 mL 样品,30% NaCl,在25℃下,经活化5 min 后的聚酰亚胺吸附搅拌棒萃取30 min (800 r/ min),然后300℃热解析4 min,使目标物脱附,再进行色谱分析。目标物在大于两个数量级浓度范围内具有良好的线性(R≥0.9995),定量限(LOQ,S/ N=10)为0.028~0.123μg/ L,重复性为1.6%~9.7%。将SBSE 与气相色谱-质谱联用,对海水、自来水和污水中的酚类进行定性与定量分析,结果表明,聚酰亚胺吸附萃取搅拌棒具有良好的选择性,最高热解析温度350℃,在分析水中痕量极性化合物领域具有广阔应用前景。  相似文献   

4.
Le Floch F  Tena MT  Ríos A  Valcárcel M 《Talanta》1998,46(5):1123-1130
A clean, highly selective supercritical fluid extraction (SFE) method for the isolation of phenols from olive leaf samples was examined. Total phenol extracts were determined using the Folin-Ciocalteu reagent. Dried, ground, sieved olive leaf samples (30 mg) are subjected to SFE, using carbon dioxide modified with 10% methanol at 334 bar, 100 degrees C (CO(2) density 0.70 g ml(-1)) at a liquid flow-rate of 2 ml min(-1) for 140 min. Diatomaceous earth is used to reduce the void volume of the extraction vessel. The influence of extraction variables such as modifier content, pressure, temperature, flow-rate, extraction time, and collection/elution variables, were studied. Supercritical fluid extracts were screened for acid compounds such as carboxylic acids and phenols using Electrospray-MS (in the negative ionization mode). SFE was found to produce higher phenol recoveries than sonication in liquid solvents such as n-hexane, diethyl ether and ethyl acetate. However, the extraction yield obtained was only 45%, using liquid methanol.  相似文献   

5.
Abstract

Snow samples were taken in June 1995 at the Sonnblick Observatory located at the top of Mt. Sonn-blick (3106 m a.s.l.) in the main ridge of the Austrian Alps, as part of the project “Organic Aerosol Scavenging”. The main interest focused on the determination of aliphatic compounds and phenols. First the method for the extraction of the organic compounds was developed using standard samples prepared in the lab. The preconcentration of the samples was performed by liquid-liquid extraction with hexane and hexane/diethylether respectively. To characterize the analytical procedure, the efficiency of the extraction procedure, the reproducibility of the overall method and the detection limits were determined. Values for the recovery of the extraction method range from 57% (fatty acids) to 95% (aliphatic alcohols). Reproducibility was found to be between 3-5%, except for the fatty acids which gave a value of 16%. Detection limits were calculated for the various substances and are between 5μg/l (phenols) and 30μg/l (fatty acids). The analysis of the eight snow samples were performed using a GC-MS-FID system. The following compounds were identified as major compounds in the snow samples: 1-dodecanol, 1-tetradecanol, 1-hexadecanol, 1-octadecanol, 2-isobutyl-4-methoxy-phenol, diisobutylphenol and dibutylphthalate. The aliphatic alcohols are of biogenic origin and are present in a concentration range from 30 to 115 μg/l melted snow. The phenols show concentrations between 5 and 30 μg/l and the phthalates range up to 40 μg/l.  相似文献   

6.
A pyrrole-based polymer was synthesized and applied as a new sorbent for solid-phase extraction (SPE) of some environmental pollutants from water samples. Polypyrrole (PPy) was synthesized by chemical oxidation of the monomer in nonaqueous solution. SPE of selected phenols, pesticides, and polyaromatic hydrocarbons (PAHs) from aqueous samples were performed using 200 mg PPy. The determination was subsequently carried out by gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). The polymer showed much higher recoveries for aromatic compounds than aliphatics. Preconcentration of sample volumes up 11 led to acceptable recoveries for aromatic and other tested polar compounds. The R.S.D. for a river water sample spiked with phenols, pesticides and PAHs at sub-ppb level was lower than 10% (n = 3) and limits of detection for these compounds were between 15 and 120 ng l(-1).  相似文献   

7.
A method for the determination of trace amounts of off-flavor compounds including 2-methylisoborneol, geosmin and 2,4,6-trichloroanisole in drinking water was developed using the stir bar sorptive extraction technique followed by thermal desorption-GC-MS analysis. The extraction conditions such as extraction mode, salt addition, extraction temperature, sample volume and extraction time were examined. Water samples (20, 40 and 60 ml) were extracted for 60-240 min at room temperature (25 degrees C) using stir bars with a length of 10 mm and coated with a 500 microm layer of polydimethylsiloxane. The extract was analyzed by thermal desorption-GC-MS in the selected ion monitoring mode. The method showed good linearity over the concentration range from 0.1 or 0.2 or 0.5 to 100 ng l(-1) for all the target analytes, and the correlation coefficients were greater than 0.9987. The detection limits ranged from 0.022 to 0.16 ng l(-1). The recoveries (89-109%) and precision (RSD: 0.80-3.7%) of the method were examined by analyzing raw water and tap water samples fortified at the 1 ng l(-1) level. The method was successfully applied to low-level samples (raw water and tap water).  相似文献   

8.
A novel solid-phase microextraction (SPME) method coupled to gas chromatography with electron capture detection (GC-ECD) was developed as an alternative to liquid-liquid and solid-phase extraction for the analysis of short-chain chlorinated paraffins (SCCPs) in water samples. The extraction efficiency of five different commercially available fibres was evaluated and the 100-microm polydimethylsiloxane coating was the most suitable for the absorption of the SCCPs. Optimisation of several SPME parameters, such as extraction time and temperature, ionic strength and desorption time, was performed. Quality parameters were established using Milli-Q, tap water and river water. Linearity ranged between 0.06 and 6 microg l(-1) for spiked Milli-Q water and between 0.6 and 6 microg l(-1) for natural waters. The precision of the SPME-GC-ECD method for the three aqueous matrices was similar and gave relative standard deviations (RSD) between 12 and 14%. The limit of detection (LOD) was 0.02 microg l(-1) for Milli-Q water and 0.3 microg l(-1) for both tap water and river water. The optimised SPME-GC-ECD method was successfully applied to the determination of SCCPs in river water samples.  相似文献   

9.
A simple and efficient liquid-phase microextraction (LPME) technique using a supported liquid hollow fiber membrane, in conjunction with gas chromatography-electron capture detector has been developed for extraction and determination of trihalomethanes (THMs) in water samples. THMs were extracted from water samples through an organic extracting solvent impregnated in the pores and filled inside the porous hollow fiber membrane. Our simple conditions were conducted at 35 degrees C with no stirring and no salt addition in order to minimize sample preparation steps. Parameters such as types of hollow fiber membranes, extracting solvents and extraction time were studied and optimized. The method exhibited enrichment factors ranged from 28- to 62-fold within 30 min extraction time. The linearity of the method ranged from 0.2 to 100 microg l(-1). The limits of detection were in the low microg l(-1) level, ranging between 0.01 and 0.2 microg l(-1). The recoveries of spiked THMs at 5 microg l(-1) in water were between 98 and 105% with relative standard deviations (RSDs) less than 4%. Furthermore, the method was applied for determination of THMs in drinking water and tap water samples was reported.  相似文献   

10.
A drop-based liquid phase microextraction and gas chromatographic-electron capture detection (GC-ECD) method was described for the determination of chlorobenzenes including chlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene and 1,2,3-trichlorobenzene in 5 ml of water. The method used 2 microl of n-hexane as extraction solvent, 5 min extraction time, a stirring rate of 600 rpm and sample ionic strength of 3 M maintained with sodium chloride at 25 degrees C (ambient temperature). The limits of detection (LODs) ranged from 0.004 microg l(-1) (for 1,3-dichlorobenzene) to 0.008 microg l(-1) (for monochlorobenzene). The dynamic linear range for all investigated chlorobenzenes was 1-50 microg l(-1). Recoveries of chlorobenzenes from fortified distilled water are over 90% for three different fortification levels (5, 15 and 45 microg l(-1)) and relative standard deviations of the recoveries are below 6%. Analysis of fortified (5 microg l(-1)) real water samples revealed that matrices had no adverse effect on extraction efficiency of proposed method. The recovery of fortified real water samples was from 90 to 94% with relative standard deviations below 6%.  相似文献   

11.
Zhang PP  Shi ZG  Feng YQ 《Talanta》2011,85(5):2581-2586
In this work, a two-step liquid-phase microextraction (LPME) method was presented for the extraction of phenols in environmental water samples. Firstly, the polar phenol in water samples (donor phase) was transferred to 1-octanol (extraction mesophase) by magnetic stirring-assisted LPME. Subsequently, target analytes in the 1-octanol was back extracted into 0.1 mol/L sodium hydroxide solution (acceptor phase) by vortex-assisted LPME. By combination of the two-step LPME, the enrichment factors were multiplied. The main features of this two-step LPME for phenols lie in the following aspects. Firstly, the extraction can be accomplished within relatively short time (ca. 20 min). Secondly, it was compatible with HPLC analysis, avoiding derivatization step that is generally necessary for GC analysis. Thirdly, high enrichment factors (296-954 fold) could be obtained for these analytes. Under the optimized conditions, the linearities were 10-1000, 1-500, 1-500, 5-500 and 1-500 ng/mL for different phenols with all regression coefficients higher than 0.9985. The limits of detection were in the range from 0.3 to 3.0 ng/mL for these analytes. Intra-and inter-day relative standard deviations were below 7.6%, indicating a good precision of the proposed method.  相似文献   

12.
Carasek E 《Talanta》2000,51(1):173-178
A simple and fast method for the extraction into xylene of sub mug l(-1) concentrations of metals using ammonium diethyldithiophosphate (DDTP) as a complexing reagent and their subsequent determination by flame atomic absorption spectrometry is described. The method was tested in sea water spiked with Au at a concentration of 3.0 mug l(-1). The extraction was carried out until the aqueous to organic phase ratio achieved a 1000-fold preconcentration of metal. Optimisation of extraction parameters and the effect of Fe interference was investigated. Sea water samples spiked with Au produced an average recovery of 95% and the detection limit (3sigma) in deionized water was 2.9 ng l(-1). High enrichment factors could be obtained due to the small final volume (mul) of organic solvent.  相似文献   

13.
Helaleh MI  Fujii S  Korenaga T 《Talanta》2001,54(6):1039-1047
In solid phase micro-extraction (SPME), the analyte is partitioned between the coating and the sample and then desorption of the concentrated analyte is followed by GC-MS, where the analytes are thermally desorbed and subsequently separated on the column and quantified by the detector. The SPME method preserves all the advantages, such as simplicity, low cost, on site sampling and does not require solvents. Poly(acrylate) coating fibers have been developed for the extraction of phenols (such as 4-tert-butylphenol, 2,4-dichlorophenol, 4-n-pentylphenol, 4-n-hexylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-n-nonylphenol, 4-n-octylphenol, pentachlorophenol and bisphenol A) in different water samples. The precision of the HS-SPME method ranges from 3–12% RSDs, depending on the compounds analyzed. More accurate results were obtained by HS-SPME with acidification and salting out, where the fiber is located above the liquid sample. The extraction period was 60 min, followed by desorption for 5 min at 300°C. After the analytes were completely desorbed, 1 μl of bis(trimethylsilyl)trifluoroacetamide (BSTFA) was injected by ordinary GC-MS injection. The trimethylsilylate peaks were improved significantly compared with free phenol peaks. The addition of salt (saturated sodium chloride) and acidification by hydrochloric acid (pH 2.0) were found to be very important for enhancing the partitioning of the polar phenols into the polymer coating and preventing ionization of the analytes. The method is capable of limits of detection of subparts per billion of the total phenols extracted from environmental water samples.  相似文献   

14.
A method combining accelerated solvent extraction with dispersive liquid–liquid microextraction was developed for the first time as a sample pretreatment for the rapid analysis of phenols (including phenol, m‐cresol, 2,4‐dichlorophenol, and 2,4,6‐trichlorophenol) in soil samples. In the accelerated solvent extraction procedure, water was used as an extraction solvent, and phenols were extracted from soil samples into water. The dispersive liquid–liquid microextraction technique was then performed on the obtained aqueous solution. Important accelerated solvent extraction and dispersive liquid–liquid microextraction parameters were investigated and optimized. Under optimized conditions, the new method provided wide linearity (6.1–3080 ng/g), low limits of detection (0.06–1.83 ng/g), and excellent reproducibility (<10%) for phenols. Four real soil samples were analyzed by the proposed method to assess its applicability. Experimental results showed that the soil samples were free of our target compounds, and average recoveries were in the range of 87.9–110%. These findings indicate that accelerated solvent extraction with dispersive liquid–liquid microextraction as a sample pretreatment procedure coupled with gas chromatography and mass spectrometry is an excellent method for the rapid analysis of trace levels of phenols in environmental soil samples.  相似文献   

15.
In the present work, a novel method for the determination of nitrobenzenes in water has been described. It is based on nonequilibrium liquid-phase microextraction and gas chromatography-electron capture detection (GC-ECD). Extraction conditions such as solvent selection, organic solvent dropsize, stirring rate, content of NaCl and extraction time were found to have significant influence on extraction efficiency. The optimized conditions were 1.5 microl toluene and 20 min extraction time at 400 rpm stirring rate without NaCl addition. The linear range was 0.1 - 50 microg l(-1) for most nitrobenzenes. The limits of detection (LODs) ranged from 0.02 microg l(-1) (for 2.6-DNT) to 0.4 microg l(-1) (for NB); and relative standard deviations (RSD) for most of the nitrobenzenes at the 10 microg l(-1) level, except for 2,6-DNT in 3 microg l(-1), were below 10%. Natural samples collected from Miyun Reservoir and tap water samples from a laboratory were successfully analyzed using the proposed method, but none of the analytes were detected. The relative recoveries of spiked water samples (at the 10 microg l(-1) level except for 2,6-DNT in 3 microg l(-1)) were from 82.6 to 118.7%.  相似文献   

16.
A method is reported for the determination, in water samples, of 10 quinolones which are used as veterinary drugs. Analytes are isolated from samples by solid-phase extraction (SPE) and analysed by reversed-phase high-performance liquid chromatography using fluorimetric detection. A solid-phase extraction procedure based on retention on HBL OASIS cartridges and elution with a mixture of acetonitrile-water in basic medium is suitable for pre-concentration of the analytes. Pre-concentration factors up to 250 can be obtained. The quinolones are separated with an octyl silica-based column and mobile phases consisting of aqueous oxalic acid solutions and acetonitrile mixtures. The attained detection limits of the whole process are in the ng l(-1) level when 250 ml of water sample is processed. Recovery rates, from natural water samples spiked at 2060 ng l(-1) level, range from 70 to 100% and common standard deviation are about 6-12%.  相似文献   

17.
In this paper, a novel method for the determination of chloroform in drinking water has been described. It is based on liquid-phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS). Extraction conditions such as solvent selection, organic solvent dropsize, stirring rate, content of NaCl and extraction time were found to have significant influence on extraction efficiency. The optimized conditions were 1.5 microl xylene, 20 min extraction time at 400 rpm stirring rate without NaCl addition. The linear range was 1.0 - 100 microg l(-1) for chloroform. The limit of detection (LOD) was 1.0 microg l(-1); and relative standard deviation (RSD) at the 30 microg l(-1) level was 2.9%. Tap water samples from a laboratory were successfully analyzed using the proposed method. The relative recovery of spiked water samples was 104%.  相似文献   

18.
Liquid phase microextraction with back extraction (LPME/BE) combined with high-performance liquid chromatography (HPLC) was studied for the determination of a variety of phenols in water samples. The target compounds were extracted from 2-ml aqueous sample adjusted to pH 1 (donor solution) through a microliter-size organic solvent phase (400-microl n-hexane), confined inside a small PTFE ring, and finally into a 1-microl basic aqueous acceptor microdrop suspended inthe aforementioned solvent phase from the tip of a microsyringe needle. After extracting for a prescribed time, the microdrop was taken back into the syringe and directly injected into an HPLC for detection. Factors relevant to the extraction procedure were studied. At the optimized extraction conditions, a large enrichment factor (more than 100-fold) can be achieved for most of the phenols within 35 min. The detection limit range was 0.5-2.5 microg/l for different analytes in aqueous samples. The results demonstrate the suitability of the LPME/BE approach to the analysis of polar compounds in aqueous samples.  相似文献   

19.
A continuous flow liquid membrane extraction (CFLME)-C18 precolumn-liquid chromatography system was developed for preconcentration and determination of chlorinated phenols (CPs). After preconcentration by CFLME, which is based on the combination of continuous flow liquid-liquid extraction and supported liquid membrane, CPs were enriched in 960 μl of 0.5 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto the C18 analytical column for separation and detected at 215 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor concentration were optimized. The proposed method presents detection limits of 0.02-0.09 μg l−1 (S/N=3) when 100 ml samples were enriched. The proposed method was successfully applied to determine CPs in tap water and river water samples with spiked recoveries in the range of 70-121%.  相似文献   

20.
Summary A sample preparation method has been developed for the determination of chlorinated phenols in water. The method is based on a supported liquid membrane extraction system connected on-line to liquid chromatography with electrochemical detection. The supported liquid membrane technique utilizes a porous PTFE membrane. The membrane is impregnated with an organic solvent which forms a barrier between two aqueous phases and enables selective extraction. The technique can easily be coupled in a flow system. In this investigation five chlorinated phenols (1–5 chlorine atoms) were extracted from natural water samples. Extraction for 30 minutes resulted in detection limits of approximately 25 ng L–1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号