首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
For the first time, the formation of a luminescent hexanuclear cluster has been used for the selective determination of copper. In aqueous solutions, the non-luminescent ligand N-ethyl-N′-methylsulfonylthiourea (EMT) forms an intensely red luminescent hexanuclear Cu(I)-cluster with an emission maximum at 663 nm only with Cu(II) ions. The intensity of the luminescence is proportional to the Cu(II) concentration and allows for selective Cu determinations in the μg l−1-range. Ubiquitous metal ions such as Fe(III), Al(III), Ca(II), Mg(II), and alkaline metal ions, as well as other heavy metal ions, e.g. Co(II), Ni(II), Zn(II), Cd(II), Hg(II), and Pb(II) are tolerated in concentrations up to 50 mg l−1. The detection limit for Cu(II) in aqueous solution, calculated according to Funk et al. [Qualitätssicherung in der Analytischen Chemie, Verlag Chemie, Weinheim, 1992], is 113 μg l−1. The cluster formation has been used for the quantitative analysis of copper in tap water and in industrial water, as well as for the localization of copper adsorbed by activated-sludge flocs.  相似文献   

2.
A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L−1 HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g−1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL−1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n = 8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.  相似文献   

3.
In this work, Fe3O4-SiO2-poly(1,2-diaminobenzene) sub-micron particles (FSPs) with high saturated magnetization of ∼60-70 emu/g were developed and utilized for the removal of As(III), Cu(II), and Cr(III) ions from aqueous solution. The isothermal results fitted well with the Freundlich model and the kinetic results fitted well with the two-site pseudo-second-order model, which indicated that multilayer adsorption of As(III), Cu(II), and Cr(III) ions on FSPs occurred at two sites with different energy of adsorption. The maximum adsorption capacities followed the order of As(III) (84 ± 5 mg/g, pH = 6.0) > Cr(III) (77 ± 3 mg/g, pH = 5.3) > Cu(II) (65 ± 3 mg/g, pH = 6.0). And the chelating interaction was considered as the main adsorption mechanism. The as-prepared materials were chemically stable with low leaching of Fe (?1.7 wt.%) and poly(1,2-diaminobenzene) (?4.9 wt.%) in tap water, sea water, and acidic/basic solutions. These metal-loaded FSPs could be easily recovered from aqueous solutions using a permanent magnet within 20 s. They could also be easily regenerated with acid. The present work indicates that the FSPs are promising for removal of heavy metal ions in field application.  相似文献   

4.
A multi-element preconcentration-separation technique for heavy metal ions in environmental samples has been established. The procedure is based on coprecipitation of gold(III), bismuth(III), cobalt(II), chromium(III), iron(III), manganese(II), nickel(II), lead(II), thorium(IV) and uranium(VI) ions by the aid of Cu(II)-9-phenyl-3-fluorone precipitate. The Cu(II)-9-phenyl-3-fluorone precipitate was dissolved by the addition 1.0 mL of concentrated HNO3 and then the solution was completed to 5 mL with distilled water. Iron, lead, cobalt, chromium, manganese and nickel levels in the final solution were determined by flame atomic absorption spectrometer, while gold, bismuth, uranium and thorium were determined by inductively coupled plasma mass spectrometer. The optimal conditions are pH 7, amounts of 9-phenyl-3-fluorone: 5 mg and amounts of Cu(II): 1 mg. The effects of concomitant ions as matrix were also examined. The preconcentration factor was 30. Gold(III), bismuth(III), chromium(III), iron(III), lead(II) and thorium(IV) were quantitatively recovered from the real samples. The detection limits for the analyte elements based on 3 sigma (n = 15) were in the range of 0.05-12.9 μg L−1. The validation of the presented procedure was checked by the analysis of two certified reference materials (Montana I Soil (NIST-SRM 2710) and Lake Sediment (IAEA-SL-1)). The procedure was successfully applied to some environmental samples including water and sediments.  相似文献   

5.
A new method that utilizes p-dimethylaminobenzaldehyde-modified nanometer SiO2 (SiO2-p-DMABD) as a solid phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). The preconcentration conditions of analytes were investigated, including the pH value, the shaking time, the mass of sorbent, the sample flow rate and volume, the elution condition and the interfering ions. The adsorption capacity of nanometer SiO2-p-DMABD was found to be (mg g− 1) Cr(III): 6.2, Cu(II): 18.6, Fe(III): 4.7 and Pb(II): 6.0 at pH 4. The adsorbed metals were quantitatively eluted with 4 mL of 1.0 mol L− 1 HCl. According to the definition of IUPAC, the detection limits (3σ) of this method for Cr(III), Cu(II), Fe(III) and Pb(II) were 0.79, 1.27, 0.40 and 1.79 ng mL− 1, respectively. The proposed method achieved satisfied results when it was applied to the determination of trace Cr(III), Cu(II), Fe(III) and Pb(II) in biological and water samples.  相似文献   

6.
Coumarin derivative 1 was synthesized as an efficient ratiometric chemodosimeter for the detection of Cu(II) in 99% water/DMSO (v/v) at pH 7.0. Mechanism studies suggested that 1 formed a complex with Cu(II) at 2:1 ratio accompanied by quenching of green fluorescence at 524 nm; when the solution was heated to 50 °C for 30 min, Cu(II)-promoted hydrolysis of coumarin lactone moiety of 1 occurred with bright blue fluorescence at 451 nm emerged. With fluorescence intensity ratio detection at 451 nm and 524 nm, 1 features an excellent sensitivity with the detection limit of 15 nmol L−1 toward Cu(II) and a good selectivity over other metal ions.  相似文献   

7.
The method of ultrasound-assisted extraction followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element concentrations (arsenic, copper, lead, antimony, and zinc) in shooting range areas was optimized. Optimization was achieved not only on the basis of the analysis of appropriate standard reference materials but also on that of 31 synthetic mixtures of matrix and analyte elements (aluminum, antimony, arsenic, calcium, copper, lead, iron, manganese, silicon, and zinc), in five concentrations. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg II 280.270 nm/Mg I 285.213 nm line intensity ratio. The highest Mg II 280.270 nm/Mg I 285.213 nm line intensity ratios were observed when a nebulizer gas flow of 0.8 L min−1, auxiliary gas flow of 0.2 L min−1 and plasma power of 1400 W were used for both the axially and radially viewed plasmas. The analysis of 31 synthetic mixtures of the selected elements showed that As concentrations could be accurately determined with axially viewed plasma alone. The determination of Pb and Sb could be performed with either axially or radially viewed plasma whereas, surprisingly, Cu could be determined with high accuracy using radial plasma alone with a power of 1400 W. All the elements investigated were determined with high accuracy using robust plasma conditions and a combination of axially and radially viewed plasmas. The total recoveries of elements from SRM 2710 (Montana soil) and SRM 2782 (Industrial sludge) were highly comparable to leach recoveries certified by the National Institute of Standards and Technology (NIST).  相似文献   

8.
The aim of this study was to investigate the possibility to synthesize new chelating polymeric microspheres owing immobilized biocompatible agent as chelating functional groups and to evaluate their performance in metal ions removal from aqueous solution.The microparticles were synthesized via precipitation polymerization of 4-O-(4-vinylbenzyl)-myo-inositol 1,3,5-orthoformate with ethylene glycol dimethacrylate (EGDMA) and subsequent exhaustive phosphorylation of myo-inositol groups using phosphoric acid.Spherical geometry with monodisperse nature of the polymeric microparticles was confirmed by scanning electron micrographs (SEM) and dimensional analysis. A large surface area of the microspheres provided a maximum interaction of metal ions and the chelating functional groups on the surface. Absorption capacity of the beads for the selected metal ions, i.e., Cu(II), Ni(II), Fe(III), was investigated in detail in aqueous solution at pH 5.0 utilizing UV/Vis spectroscopy. This study showed that the macromolecular systems are very effective in chelating these metal ions and the affinity order of the microbeads toward metal ions is: Fe(III) > Ni(II) > Cu(II).The chelating beads can be easily regenerated by 1.0 M HNO3 with high effectiveness. These features make the synthesized beads a potential candidate for metal ions removal at high capacity.  相似文献   

9.
A measuring method using a fast Fourier transform (FFT) analyzer is suggested to estimate the emission intensity from a radio-frequency (RF)-powered glow discharge plasma for atomic emission analysis. The FFT analyzer has an ability to disperse the components by frequency from an overall signal, and thus works as a selective detector in modulation spectroscopy. In the RF glow discharge plasma, a dc bias current can be introduced by connecting an external electric circuit with the discharge lamp, which predominantly enhances the emission intensities. Further, the bias current can be pulsated with a switching device to modulate the emission intensities, and then the modulated component was selectively detected with the FFT analyzer. This method greatly improved the data precision. The emission intensity of the Cu I 324.75-nm line in an Fe-based alloy sample containing 0.043 mass% Cu could be estimated with a relative standard deviation of 0.20%. The 3σ detection limits of Cu in Fe-based alloys could be obtained to be 2.3 × 10− 6 mass% Cu for Cu I 324.75 nm and 6.8 × 10− 6 mass% Cu for Cu I 327.40 nm.  相似文献   

10.
On the basis of the temporal evolutions of the singly, doubly and triply ionized tin (Sn II, Sn III and Sn IV, respectively) spectral line intensities, in the pulsed helium and nitrogen plasmas, the important role of the He I and He II metastables has been observed in the Sn II, Sn III and Sn IV ionization and population processes. According to these processes, one can expect realization of several laser levels in the Sn II (11.07, 11.20, 12.44 and 13.11 eV), Sn III (15.91, 17.82, 19.13 and 20.19 eV) and Sn IV (20.51 eV) spectra. The modified version of the linear, low-pressure, pulsed arc was used as a plasma source operated in helium with tin atoms, as impurities, evaporated from tin cylindrical plates located in the homogenous part of the discharge tube. This plasma source provides good conditions for a generation of the Sn III, Sn IV and Sn V ions at relatively low electron temperatures (below 18,000 K) providing low background radiation around the intense Sn IV and Sn III spectral lines in the helium plasma. The 222.613 ± 0.0005 nm Sn IV line, not observed up to now, has been identified. The marked, but not classified 243.688 nm Sn spectral line is sorted by ionization stages. The shapes of Sn III and Sn IV lines, ranged between 207 nm and 307 nm, have been obtained. At a 17,500 K electron temperature and 1.07 × 1023 m− 3 electron density the Stark broadening was found as the dominant mechanism in the mentioned lines broadening. The measured Stark widths of the prominent nine Sn IV and seven Sn III lines are the first data in the literature. The Stark widths of the intense 229.913 nm and 288.766 nm Sn IV lines can be used for the plasma electron density and temperature diagnostics purposes.  相似文献   

11.
A new thiacalix[4]arene based fluorescent sensor bearing two dansyl groups has been synthesized in cone conformation. In CH3CN:CH2Cl2 (1:1), the presence of Cu (II) induces the formation of a 1:1 metal:ligand complex, which exhibits increasing emission at 433 nm at the expense of the fluorescent emission of 1 centered at 504 nm. The detection limit of the sensor for Cu2+ is 2×10−7 mol L−1. For anion sensing, 1 shows a high selectivity for fluoride ions over other anions tested.  相似文献   

12.
New mononuclear compounds of the ligand 1-(2-hydroxyphenyl)-3-phenylpropane-1,3-dione (H2L) with Cu(II) and several lanthanoid(III) ions, where Ln(III) = Pr, Nd, Eu, Gd, have been synthesized and characterized by spectroscopic methods and X-ray crystal structure determinations. In all compounds, the ligand coordinates in a bidentate chelating manner, using the diketone function. In the [Cu(HL)2], the coordination geometry of Cu(II) ion is slightly distorted square-planar; two strong intramolecular (OH?O) hydrogen-bonding interactions are established between the phenolate group and the neighboring ketone function. The lanthanoid(III) compounds have the general formula [Ln(HL)3(CH3OH)2] · CH3OH · 2H2O; the lanthanoid(III) ion (Ln) is eight-coordinated and the coordination geometry is based on a distorted square-antiprism. In addition to the intramolecular hydrogen bonding (OH?O), intermolecular hydrogen-bonding interactions are also present between the coordinated methanol molecule and the non-coordinated methanol molecule giving rise to a three-dimensional network.  相似文献   

13.
We have investigated the effect of varying transverse magnetic field on the plasma plume emission of laser-produced lithium plasma. Two atomic transitions for lithium neutral Li (I) and two for Li ion LI (II) are taken for the study. It has been found that for Li (I), the emission from 670.8 nm transition (2s2S1/2←2p2P3/21/2) shows initial enhancement and then subsequent decrease for higher fields. Of course, the overall intensity is increased for all the fields when compared to the case of without field. On the other hand, for 610.3 nm (2p2P1/2←3d2P3/25/2), there is continuous decrease in intensity. Interestingly, for Li (II) transitions also, after an initial increase in intensity up to 0.08 Ta decrease is observed. From the atomic analysis, we find that for 670.8 nm line, the cause of initial enhancement is increase in electron impact excitation whereas for decreased intensity, increased field-induced ionization appears to be responsible mechanism. However, for 610.3 nm line, decrease in intensity appears to be due to decreased recombination. For Li (II), 478.8 nm (3p1P1←4d1D2) and 548.4 nm (2s3S1←2p3P2,1,0) transitions, initial increase appears to be due to increased confinement (increase in plasma density) and subsequent decrease in intensity with increase in field due to decreased recombination.  相似文献   

14.
Candir S  Narin I  Soylak M 《Talanta》2008,77(1):289-293
A cloud point extraction (CPE) procedure has been developed for the determination trace amounts of Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II) ions by using flame atomic absorption spectrometry. The proposed cloud point extraction method was based on cloud point extraction of analyte metal ions without ligand using Tween 80 as surfactant. The surfactant-rich phase was dissolved with 1.0 mL 1.0 mol L−1 HNO3 in methanol to decrease the viscosity. The analytical parameters were investigated such as pH, surfactant concentration, incubation temperature, and sample volume, etc. Accuracy of method was checked analysis by reference material and spiked samples. Developed method was applied to several matrices such as water, food and pharmaceutical samples. The detection limits of proposed method were calculated 2.8, 7.2, 0.4, 1.1, 0.8 and 1.7 μg L−1 for Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II), respectively.  相似文献   

15.
Silica gel-bound amines phase modified with p-dimethylaminobenzaldehyde (p-DMABD) was prepared based on chemical immobilization technique. The product (SG-p-DMABD) was used as an adsorbent for the solid-phase extraction (SPE) Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The uptake behaviors of SG-p-DMABD for extracting these metal ions were studied using batch and column procedures. For the batch method, the optimum pH range for Cr(III) and Ni(II) extraction was ≥ 3, for Cu(II), Pb(II) and Zn(II) extraction it was ≥ 4. For simultaneous enrichment and determination of all the metals on the newly designed adsorbent, the pH value if 4.0 was selected. All the metal ions can be desorbed with 2.0 mL of 0.5 mol L− 1 of HCl. The results indicate that SG-p-DMABD has rapid adsorption kinetics using the batch method. The adsorption capacity for these metal ions is in the range of 0.40-1.15 mmol g− 1, with a high enrichment factor of 125. The presence of commonly coexisting ions does not affect the sorption capacities. The detection limits of the method were found to be 1.10, 0.69, 0.99, 1.10 and 6.50 μg L− 1 for Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was 5.0% (n = 8) for all metal ions. The method was applied to the preconcentration of Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) from the certified reference material (GBW 08301, river sediment) and water samples with satisfactory results.  相似文献   

16.
A simple dispersive solid-phase micro-extraction method based on CoFe2O4 nano-particles (NPs) functionalized with 8-hydroxyquinoline (8-HQ) with the aid of sodium dodecyl sulfate (SDS) was developed for separation of Al(III) ions from aqueous solutions. Al(III) ions are separated at pH 7 via complex formation with 8-HQ using the functionalized CoFe2O4 nano-particles sol solution as a dispersed solid-phase extractor. The separated analyte is directly quantified by a spectrofluorometric method at 370 nm excitation and 506 nm emission wavelengths. A comparison of the fluorescence of Al(III)–8-HQ complex in bulk solution and that of Al(III) ion interacted with 8-HQ/SDS/CoFe2O4 NPs revealed a nearly 5-fold improvement in intensity. The experimental factors influencing the separation and in situ monitoring of the analyte were optimized. Under these conditions, the calibration graph was linear in the range of 0.1–300 ng mL−1 with a correlation coefficient of 0.9986. The limit of detection and limit of quantification were 0.03 ng mL−1 and 0.10 ng mL−1, respectively. The inter-day and intra-day relative standard deviations for six replicate determinations of 150 ng mL−1 Al(III) ion were 2.8% and 1.7%, respectively. The method was successfully applied to direct determine Al(III) ion in various human serum and water samples.  相似文献   

17.
Water-soluble l-cysteine-capped-CdS nanoparticles were prepared in aqueous solution at room temperature through a straightforward one-pot process by using safe and low-cost inorganic salts as precursors, and characterized by transmission electron microscopy, X-ray diffraction spectrometry, Fourier transform infrared spectrometry, spectrofluorometry and ultraviolet-visible spectrometry. The prepared l-cysteine-capped-CdS nanoparticles were evaluated as fluorescence probe for Hg(II) detection. The fluorescence quenching of the l-cysteine-capped-CdS nanoparticles depended on the concentration and pH of Hg(II) solution. Maximum fluorescence quenching was observed at pH 7.4 with the excitation and emission wavelengths of 360 nm and 495 nm, respectively. Quenching of its fluorescence due to Hg(II) at the 20 nmol l−1level was unaffected by the presence of 5 × 106-fold excesses of Na(I) and K(I), 5 × 105-fold excesses of Mg(II), 5 × 104-fold excesses of Ca(II), 500-fold excesses of Al(III), 91-fold excesses of Mn(II), 23.5-fold excesses of Pb(II), 25-fold excesses of Fe(III), 25-fold excesses of Ag(I), 8.5-fold excesses of Ni(II) and 5-fold excesses of Cu(II). Under optimal conditions, the quenched fluorescence intensity increased linearly with the concentration of Hg(II) ranging from 16 nmol l−1 to 112 nmol l−1. The limit of detection for Hg(II) was 2.4 nmol l−1. The developed method was applied to the detection of trace Hg(II) in aqueous solutions.  相似文献   

18.
Soliman EM  Saleh MB  Ahmed SA 《Talanta》2006,69(1):55-60
Dimethyl sulfoxide (DMSO) was simply immobilized to neutral alumina via quite strong hydrogen bonding between sulfoxide oxygen and surface alumina hydroxo groups. The produced alumina-modified dimethyl sulfoxide (AMDMSO) solid phase (SP)-extractor experienced high thermal and medium stability. Moreover, the small and compact size of DMSO moiety permit high surface coverage evaluated to be 2.1 ± 0.1 mmol g−1 of alumina. Hg(II) uptake was 1.90 mmol g−1(distribution coefficient log Kd = 5.658) at pH 1.0 or 2.0, 1.68 mmol g−1 (log Kd = 4.067) at pH 3.0 or 4.0 while the metal ions Ca(II), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Pb(II) showed low values 0.513-0.118 mmol g−1 (log Kd < 3.0) in the pH range 4.0-7.0. A mechanism was suggested to explain the unique uptake of Hg(II) ions by binding as neutral and chloroanionic species predominate at pH values ≤ 3.0 of a medium rich in chloride ions. A direct and fast batch separation mode was achieved successfully to retain selectively Hg(II) in presence of other eight coexisting metal ions. Thus, Hg(II) was completely retained; Ca(II), Co(II), Ni(II) and Cd(II) were not retained, while Pb(II), Cu(II), Zn(II) and Fe(III) exhibited very low percentage retention evaluated to be 0.42, 0.49, 1.4 and 5.43%, respectively. The utility of the new modified alumina sorbent for concentrating of ultratrace amounts of Hg(II) was performed by percolating 2 l of doubly distilled water, drinking tap water, and Nile river water spiked with 10 ng/l over 100 mg of the sorbent packed in a minicolumn used as a thin layer enrichment bed prior to the determination by CV-AAS. The high recovery values obtained (98.5 ± 0.5, 98.5 ± 0.5 and 103.0 ± 1.0) based on excellent enrichment factor 1000, along with a good precision (R.S.D.% 0.51-0.97%, N = 3) demonstrate the accuracy and validity of the new modified alumina sorbent for preconcentrating ultratrace amounts of Hg(II) with no matrix interference.  相似文献   

19.
Arnab Sarkar 《Talanta》2009,78(3):800-1664
Laser-induced breakdown spectroscopy (LIBS) has been developed for determining the percentage of uranium in thorium-uranium mixed oxide fuel samples required as a part of the chemical quality assurance of fuel materials. The experimental parameters were optimized using mixed oxide pellets prepared from 1:1 (w/w) mixture of thorium-uranium mixed oxide standards and using boric acid as a binder. Calibration curves were established using U(II) 263.553 nm, U(II) 367.007 nm, U(II) 447.233 nm and U(II) 454.363 nm emission lines. The uranium amount determined in two synthetic mixed oxide samples using calibration curves agreed well with that of the expected values. Except for U(II) 263.553 nm, all the other emission lines exhibited a saturation effect due to self-absorption when U amount exceeded 20 wt.% in the Th-U mixture. The present method will be useful for fast and routine determination of uranium in mixed oxide samples of Th and U, without the need for dissolution, which is difficult and time consuming due to the refractory nature of ThO2. The methodology developed is encouraging since a very good analytical agreement was obtained considering the limited resolution of the spectrometer employed in the work.  相似文献   

20.
A selective method has been developed for the extraction chromatographic trace level separation of Cu(II) with Versatic 10 (liquid cation exchanger) coated on silanised silica gel (SSG-V10). Cu(II) has been extracted from 0.1 M acetate buffer at the range of pH 4.0–5.5. The effects of foreign ions, pH, flow-rate, stripping agents on extraction and elution have been investigated. Exchange capacity of the prepared exchanger at different temperatures with respect to Cu(II) has been determined. The extraction equilibrium constant (Kex) and different standard thermodynamic parameters have also been calculated by temperature variation method. Positive value of ΔH (7.98 kJ mol−1) and ΔS (0.1916 kJ mol−1) and negative value of ΔG (−49.16 kJ mol−1) indicated that the process was endothermic, entropy gaining and spontaneous. Preconcentration factor was optimized at 74.7 ± 0.2 and the desorption constants Kdesorption1(1.4 × 10−2) and Kdesorption2(9.8 × 10−2) were determined. The effect of pH on Rf values in ion exchange paper chromatography has been investigated. In order to investigate the sorption isotherm, two equilibrium models, the Freundlich and Langmuir isotherms, were analyzed. Cu(II) has been separated from synthetic binary and multi-component mixtures containing various metal ions associated with it in ores and alloy samples. The method effectively permits sequential separation of Cu(II) from synthetic quaternary mixture containing its congeners Bi(III), Sn(II), Hg(II) and Cu(II), Cd(II), Pb(II) of same analytical group. The method was found effective for the selective detection, removal and recovery of Cu(II) from industrial waste and standard alloy samples following its preconcentration on the column. A plausible mechanism for the extraction of Cu(II) has been suggested.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号