首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
Peripheral MR angiography requires high resolution and arterial contrast. Neither can be obtained simultaneously due to the short arterial phase of the contrast agent. To improve temporal resolution, keyhole imaging was developed, which combines high resolution and arterial k-spaces at the time of image acquisition. Here, a related approach is introduced for image post-processing in the Fourier domain. It is demonstrated that simple substitution of the central k-space with low-resolution data leads to severe distortion. Hence, a dedicated calculation scheme is necessary for composite k-space post-processing. A solution is presented for high-resolution arterial peripheral MR angiography that uses subtraction of venous intensities from the central high-resolution k-space. The calculations in the Fourier domain do not require interpolations between the different resolutions. High-resolution steady-state MR angiography, which exhibits contrast-enhanced arteries and veins at an isotropic resolution of 0.65 mm, and standard resolution arterial first-pass MR angiography were combined to obtain images with the resolution of the steady-state images and arterial contrast. Numerical simulations on software phantoms are presented. The operation of the method is demonstrated in five patients.  相似文献   

2.

Purpose

The goal of this study was to implement time efficient data acquisition and reconstruction methods for 3D magnetic resonance spectroscopic imaging (MRSI) of gliomas at a field strength of 3T using parallel imaging techniques.

Methods

The point spread functions, signal to noise ratio (SNR), spatial resolution, metabolite intensity distributions and Cho:NAA ratio of 3D ellipsoidal, 3D sensitivity encoding (SENSE) and 3D combined ellipsoidal and SENSE (e-SENSE) k-space sampling schemes were compared with conventional k-space data acquisition methods.

Results

The 3D SENSE and e-SENSE methods resulted in similar spectral patterns as the conventional MRSI methods. The Cho:NAA ratios were highly correlated (P<.05 for SENSE and P<.001 for e-SENSE) with the ellipsoidal method and all methods exhibited significantly different spectral patterns in tumor regions compared to normal appearing white matter. The geometry factors ranged between 1.2 and 1.3 for both the SENSE and e-SENSE spectra. When corrected for these factors and for differences in data acquisition times, the empirical SNRs were similar to values expected based upon theoretical grounds. The effective spatial resolution of the SENSE spectra was estimated to be same as the corresponding fully sampled k-space data, while the spectra acquired with ellipsoidal and e-SENSE k-space samplings were estimated to have a 2.36–2.47-fold loss in spatial resolution due to the differences in their point spread functions.

Conclusion

The 3D SENSE method retained the same spatial resolution as full k-space sampling but with a 4-fold reduction in scan time and an acquisition time of 9.28 min. The 3D e-SENSE method had a similar spatial resolution as the corresponding ellipsoidal sampling with a scan time of 4:36 min. Both parallel imaging methods provided clinically interpretable spectra with volumetric coverage and adequate SNR for evaluating Cho, Cr and NAA.  相似文献   

3.
In this article, we present a modified interleaved segmented echo-planar imaging (SEPI) sequence with a center-out k-space trajectory that is especially designed for susceptibility-weighted imaging applications. We introduce a simple and efficient technique to phase correct the acquired SEPI data in the presence of moderate field inhomogeneities. This phase correction reduces the distortion in the phase-encoding direction without requiring an extra reference scan. With the use of a center-out k-space trajectory and a low-spatial-frequency phase map, phase discontinuities between segments can be eliminated, in principle, iteratively using a fast Fourier transform from the center segment to the outermost segment in k-space. With an extra echo added in front of the echo train, neither phase unwrapping nor an extra reference scan is required to obtain a low-spatial-frequency phase map. The method is shown to remove blurring and reduce geometric distortion caused by phase changes from echo to echo in both phantom and human data. The method is most useful for high-resolution imaging applications and moderate factors of speed improvement.  相似文献   

4.
It is generally a challenging task to reconstruct dynamic magnetic resonance (MR) images with high spatial and high temporal resolutions, especially with highly incomplete k-space sampling. In this work, a novel method that combines a non-rigid image registration technique with sparsity-constrained image reconstruction is introduced. Employing a multi-resolution free-form deformation technique with B-spline interpolations, the non-rigid image registration accurately models the complex deformations of the physiological dynamics, and provides artifact-suppressed high spatial-resolution predictions. Based on these prediction images, the sparsity-constrained data fidelity-enforced image reconstruction further improves the reconstruction accuracy. When compared with the k-t FOCUSS with motion estimation/motion compensation (MEMC) technique on volunteer scans, the proposed method consistently outperforms in both the spatial and the temporal accuracy with variously accelerated k-space sampling. High fidelity reconstructions for dynamic systolic phases with reduction factor of 10 and cardiac perfusion series with reduction factor of 3 are presented.  相似文献   

5.
6.
Contrast-enhanced magnetic resonance angiography (MRA) is a promising technique for coronary artery imaging. The blood signal changes during the contrast injection will result in image artifacts, blurring and relatively low signal-to-noise ratio, when the k-space segments from different cardiac cycles are combined to reconstruct the final image as “time averaged.” Thus, it is important to acquire data during maximal blood signal enhancement for first-pass, contrast-enhanced MRA, and relatively high temporal resolution is required. This work demonstrated the feasibility of highly constrained backprojection reconstruction for time-resolved, contrast-enhanced coronary MRA. With this method, the temporal resolution can be increased. In addition, coronary artery images around blood signal enhancement peak have significantly improved contrast-to-noise ratio and suppressed artifacts compared to the composite images which were collected during a much longer acquisition time during substantial blood signal changes.  相似文献   

7.
Spiral acquisition schemes offer unique advantages such as flow compensation, efficient k-space sampling and robustness against motion that make this option a viable choice among other non-Cartesian sampling schemes. For this reason, the main applications of spiral imaging lie in dynamic magnetic resonance imaging such as cardiac imaging and functional brain imaging. However, these advantages are counterbalanced by practical difficulties that render spiral imaging quite challenging. Firstly, the design of gradient waveforms and its hardware requires specific attention. Secondly, the reconstruction of such data is no longer straightforward because k-space samples are no longer aligned on a Cartesian grid. Thirdly, to take advantage of parallel imaging techniques, the common generalized autocalibrating partially parallel acquisitions (GRAPPA) or sensitivity encoding (SENSE) algorithms need to be extended. Finally, and most notably, spiral images are prone to particular artifacts such as blurring due to gradient deviations and off-resonance effects caused by B0 inhomogeneity and concomitant gradient fields. In this article, various difficulties that spiral imaging brings along, and the solutions, which have been developed and proposed in literature, will be reviewed in detail.  相似文献   

8.
A free-breathing 3D cine steady-state free precession (SSFP) technique was developed using the z intensity-weighted position (ZIP) which is the center of mass of a projection along the slice direction as a respiratory gating signal. The ZIP signal was continuously acquired using a slice encoded k-space center sampling in every TR. The performance of this gating method was compared with a method using the k-space center signal (KC) and with conventional 2D breath-hold cine SSFP in healthy subjects by measuring image quality and left ventricular function. The preliminary data obtained here demonstrated that the ZIP gating method provided superior respiratory motion artifact suppression when compared to the KC gating and provided left ventricular ejection fractions, and end-diastolic and end-systolic volumes similar to those obtained with the breath-hold 2D cine SSFP acquisition.  相似文献   

9.
A number of methods using temporal and spatial constraints have been proposed for reconstruction of undersampled dynamic magnetic resonance imaging (MRI) data. The complex data can be constrained or regularized in a number of different ways, for example, the time derivative of the magnitude and phase image voxels can be constrained separately or jointly. Intuitively, the performance of different regularizations will depend on both the data and the chosen temporal constraints. Here, a complex temporal total variation (TV) constraint was compared to the use of separate real and imaginary constraints, and to a magnitude constraint alone. Projection onto Convex Sets (POCS) with a gradient descent method was used to implement the diverse temporal constraints in reconstructions of DCE MRI data. For breast DCE data, serial POCS with separate real and imaginary TV constraints was found to give relatively poor results while serial/parallel POCS with a complex temporal TV constraint and serial POCS with a magnitude-only temporal TV constraint performed well with an acceleration factor as large as R=6. In the tumor area, the best method was found to be parallel POCS with complex temporal TV constraint. This method resulted in estimates for the pharmacokinetic parameters that were linearly correlated to those estimated from the fully-sampled data, with Ktrans,R=6=0.97 Ktrans,R=1+0.00 with correlation coefficient r=0.98, kep,R=6=0.95 kep,R=1+0.00 (r=0.85). These results suggest that it is possible to acquire highly undersampled breast DCE-MRI data with improved spatial and/or temporal resolution with minimal loss of image quality.  相似文献   

10.
MR raw data collected using non-Cartesian method can be transformed on Cartesian grids by traditional gridding algorithm (GA) and reconstructed by Fourier transform. However, its runtime complexity is O(K× N2), where resolution of raw data is N× N and size of convolution window (CW) is K. And it involves a large number of matrix calculation including modulus, addition, multiplication and convolution. Therefore, a Compute Unified Device Architecture (CUDA)-based algorithm is proposed to improve the reconstruction efficiency of PROPELLER (a globally recognized non-Cartesian sampling method). Experiment shows a write–write conflict among multiple CUDA threads. This induces an inconsistent result when synchronously convoluting multiple k-space data onto the same grid. To overcome this problem, a reverse gridding algorithm (RGA) was developed. Different from the method of generating a grid window for each trajectory as in traditional GA, RGA calculates a trajectory window for each grid. This is what “reverse” means. For each k-space point in the CW, contribution is cumulated to this grid. Although this algorithm can be easily extended to reconstruct other non-Cartesian sampled raw data, we only implement it based on PROPELLER. Experiment illustrates that this CUDA-based RGA has successfully solved the write–write conflict and its reconstruction speed is 7.5 times higher than that of traditional GA.  相似文献   

11.
Undersampling k-space is an effective way to decrease acquisition time for MRI. However, aliasing artifacts introduced by undersampling may blur the edges of magnetic resonance images, which often contain important information for clinical diagnosis. Moreover, k-space data is often contaminated by the noise signals of unknown intensity. To better preserve the edge features while suppressing the aliasing artifacts and noises, we present a new wavelet-based algorithm for undersampled MRI reconstruction. The algorithm solves the image reconstruction as a standard optimization problem including a ?2 data fidelity term and ?1 sparsity regularization term. Rather than manually setting the regularization parameter for the ?1 term, which is directly related to the threshold, an automatic estimated threshold adaptive to noise intensity is introduced in our proposed algorithm. In addition, a prior matrix based on edge correlation in wavelet domain is incorporated into the regularization term. Compared with nonlinear conjugate gradient descent algorithm, iterative shrinkage/thresholding algorithm, fast iterative soft-thresholding algorithm and the iterative thresholding algorithm using exponentially decreasing threshold, the proposed algorithm yields reconstructions with better edge recovery and noise suppression.  相似文献   

12.
A connection between the formation of defect bipolarons (i.e. U-centers or U-bipolarons) and superconductivity in high-Tcsuperconductors (HTSC) is considered in two pairing limits of carriers in realr- andk-spaces. The irrelevance ofr-space U-bipolarons to superconductivity is motivated. It is shown that the formation ofk-space U-bipolarons and their subsequent attractive single particle and pair condensation lead to depressed (in comparison with lattice bipolarons) superconductivity due to a large mass of such U-bipolarons. It is argued that the coexistence ofk-space lattice bipolarons andr-space U-bipolarons leads to the shift of the maximum of the concentration dependenceTc(n)to higher carrier concentrations, in accordance with the observations in HTSC.  相似文献   

13.
Two rapid, pure phase encode, centric scan, Single Point Ramped Imaging with T1-Enhancement (SPRITE) MRI methods are described. Each retains the benefits of the standard SPRITE method, most notably the ability to image short T2* systems, while increasing the sensitivity and generality of the technique. The Spiral-SPRITE method utilizes a modified Archimedean spiral k-space trajectory. The Conical-SPRITE method utilizes a system of spirals mapped to conical surfaces to sample the k-space cube. The sampled k-space points are naturally Cartesian grid points, eliminating the requirement of a re-gridding procedure prior to image reconstruction. The effects of transient state behaviour on image resolution and signal/noise are explored.  相似文献   

14.
Coronary vessel wall magnetic resonance (MR) imaging is important for heart disease diagnosis but often suffers long scan time. Compressed sensing (CS) has been previously used to accelerate MR imaging by reconstructing an MR image from undersampled k-space data using a regularization framework. However, the widely used regularizations in the current CS methods often lead to smoothing effects and thus are unable to reconstruct the coronary vessel walls with sufficient resolution. To address this issue, a novel block-weighted total variation regularization is presented to accelerate the coronary vessel wall MR imaging. The proposed regularization divides the image into two parts: a region-of-interest (ROI) which contains the coronary vessel wall, and the other region with less concerned features. Different penalty weights are given to the two regions. As a result, the small details within ROI do not suffer from over-smoothing while the noise outside the ROI can be significantly suppressed. Results with both numerical simulations and in vivo experiments demonstrated that the proposed method can reconstruct the coronary vessel wall from undersampled k-space data with higher qualities than the conventional CS with the total variation or the edge-preserved total variation.  相似文献   

15.
Propagation of shock waves in soda lime glass, which is a transparent material, has been studied using the optical shadowgraphy technique. The time-resolved shock velocity information has been obtained (1) in single shot, using the chirped pulse shadowgraphy technique, with a temporal resolution of tens of picoseconds and (2) in multiple shots, using conventional snapshot approach, with a second harmonic probe pulse. Transient shock velocities of (5–7) × 106 cm/s have been obtained. The scaling of the shock velocity with intensity in the 2 × 1013–1014 W/cm2 range has been obtained. The shock velocity is observed to scale with laser intensity as I0.38. The present experiments also show the presence of ionization tracks, generated probably due to X-ray hotspots from small-scale filamentation instabilities. The results and various issues involved in these experiments are discussed.  相似文献   

16.

Purpose

To compare the degree of visualization of the bile duct and portal vein in terms of the difference in k-space ordering on a three-dimensional (3D) segmented true fast imaging with steady-state precession (trueFISP) sequence.

Materials and Methods

A breath-hold coronal 3D segmented trueFISP sequence was prospectively performed on 14 healthy volunteers. Images obtained with centric and linear k-space ordering in the k(x)–k(y) plane were compared by two independent radiologists qualitatively with depiction scores on a five-point scale (1=not seen to 5=excellent depiction) using the Wilcoxon signed-rank test. Images were also compared quantitatively using relative contrast values for the bile duct and portal vein against the hepatic parenchyma using a paired t-test.

Results

With centric ordering, both the mean depiction scores and relative contrast values for the portal vein were significantly lower than those with linear ordering (1.5 vs. 3.5, P<.01; and 0.08±0.19 vs. 0.51±0.10, P<.01, respectively). However, in the bile duct, there were no significant differences, only slight differences were found among the results obtained with centric and linear ordering (3.9 vs. 3.8, P=.72; and 0.59±0.06 vs. 0.68±0.06, P<.01, respectively).

Conclusion

For visualizing the bile duct, centric k-space ordering on 3D segmented trueFISP sequence is recommended, while linear ordering is recommended for portal vein visualization.  相似文献   

17.
The aim of this study was to evaluate intracranial arterial stenoses and aneurysms with accelerated time-resolved three-dimensional (3D) phase-contrast MRI or 4D flow. The 4D flow technique was utilized to image four normal volunteers, two patients with intracranial stenoses and two patients with intracranial aneurysms. In order to reduce scan time, parallel imaging was combined with an acquisition strategy that eliminates the corners of k-space. In the two patients with intracranial stenoses, 4D flow velocity measurements showed that one patient had normal velocity profiles in agreement with a previous magnetic resonance angiogram (MRA), while the second showed increased velocities that indicated a less significant narrowing than suspected on a previous MRA, as confirmed by catheter angiography. This result may have prevented an invasive angiogram. In the two patients with 4-mm intracranial aneurysm, one had a stable helical flow pattern with a large jet, while the other had a temporally unstable flow pattern with a more focal jet possibly indicating that the second aneurysm may have a higher likelihood of rupture. Accelerated 4D flow provides time-resolved 3D velocity data in an 8- to 10-min scan. In the stenosis patients, the addition of 4D flow to a traditional MRA adds the velocity data provided from transcranial Doppler ultrasound (TCD) possibly allowing for more accurate grading of stenoses. In the aneurysm patients, visualization of flow patterns may help to provide prognostic information about future risk of rupture.  相似文献   

18.
The double inversion recovery (DIR) imaging technique has various applications such as black blood magnetic resonance imaging and gray/white matter imaging. Recent clinical studies show the promise of DIR for high resolution three dimensional (3D) gray matter imaging. One drawback in this case however is the long data acquisition time needed to obtain the fully sampled 3D spatial frequency domain (k-space) data. In this paper, we propose a method to solve this problem using the compressed sensing (CS) algorithm with contourlet transform. The contourlet transform is an effective sparsifying transform especially for images with smooth contours. Therefore, we applied this algorithm to undersampled DIR images and compared with a CS algorithm using wavelet transform by evaluating the reconstruction performance of each algorithm for undersampled k-space data. The results show that the proposed CS algorithm achieves a more accurate reconstruction in terms of the mean structural similarity index and root mean square error than the CS algorithm using wavelet transform.  相似文献   

19.
A new, one-dimensional method for the measurement of pulsewave velocities using real-time magnetic resonance (MR) imaging is presented. The measurement sequence is essentially of a RACE-type (Real Time Acquisition and Evaluation) with interleaved acquisition in two not necessarily parallel slices. In each slice the blood flow velocity perpendicular to the slice orientation was monitored. From the relative time difference of blood flow activity and the slice distance, pulsewave velocities were calculated. With a time resolution of 13 ms an overall acquisition time of 3.3 s was achieved. A method for suppression of signal contributions from stationary tissue along the axis of projection is discussed on the basis of a simplified mathematical model. Preliminary volunteer studies show that pulsewave velocities in the range of 1–10 m/s can be measured with an uncertainty of about 0.6 m/s at a conventional 1.5 T imager with a gradient system of maximal 10 mT/m.  相似文献   

20.
Fourier-series windowing, a technique used to obtain spatially localized in vivo NMR spectra, is extended to fields-of-view containing a number of arbitrarily shaped regions of interest. For each volume, k-space weighting functions are derived and then combined to give an overall k-space sampling pattern - the number of signal acquisitions per phase-encoding vector - which can then be used to obtain spatially localized spectra of optimal sensitivity, consistent with a specified degree of localization. The technique is compared with the related methods of chemical-shift imaging and spectral localization by imaging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号