共查询到20条相似文献,搜索用时 46 毫秒
1.
Ivan Pedrosa Long Ngo Jesse Wei Michael Schuster Houman Mahallati Martin Smith Neil M. Rofsky 《Magnetic resonance imaging》2009
Objective
The objective of this study was to retrospectively analyze the value of dynamic half-Fourier single-shot turbo spin echo (HASTE) imaging in patients with suspected deep venous thrombosis (DVT).Materials and Methods
Fifty-five veins in 24 patients were interrogated using a HASTE sequence with the patients relaxed and in various degrees of Valsalva. Veins were analyzed for changes in caliber (+CAL) and signal intensity (+SI) or in their absence (−CAL and −SI, respectively) and compared with the presence of thrombus on gadolinium-enhanced magnetic resonance imaging.Results
There was no thrombus in veins with the +CAL, +SI pattern (n=40) (P<.01). Five of seven veins (71.4%) with the −CAL, −SI pattern had thrombus (P<.01). A qualitative change in CAL had a sensitivity of 100% and a specificity of 91% for the presence of thrombus. An increase of 1.5 mm in CAL had a sensitivity of 100% and a specificity of 93% for this diagnosis.Conclusion
Dynamic HASTE imaging offers a physiological method to evaluate veins for deep venous thrombosis. 相似文献2.
Marco Moschetta Michele TelegrafoLeonarda Rella Arcangela CapolongoAmato Antonio Stabile Ianora Giuseppe Angelelli 《Magnetic resonance imaging》2014
Objectives
Diffusion imaging represents a new imaging tool for the diagnosis of breast cancer. This study aims to investigate the role of diffusion-weighted MRI with background body signal suppression (DWIBS) for evaluating breast lesions.Methods
90 patients were prospectively evaluated by MRI with STIR, TSE-T2, contrast enhanced THRIVE-T1 and DWIBS sequences. DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤ 1.44 × 10- 3 mm2/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated.Results
In 53/90 (59%) patients, DWIBS indicated the presence of breast lesions, 16 (30%) with ADC values of > 1.44 and 37 (70%) with ADC ≤ 1.44. The comparison with histology showed 25 malignant and 28 benign lesions. DWIBS sequences obtained sensitivity, specificity, DA, PPV and NPV values of 100, 82, 87, 68 and 100%, respectively.Conclusion
DWIBS can be proposed in the MRI breast protocol representing an accurate diagnostic complement. 相似文献3.
Weiland JD Faraji B Greenberg RJ Humayun MS Shellock FG 《Magnetic resonance imaging》2012,30(3):382-389
Objective
The objective was to evaluate magnetic resonance imaging (MRI) issues (magnetic field interactions, heating, artifacts and functional alterations) at 1.5 T and 3 T for the Argus II Retinal Prosthesis (Second Sight Medical Products, Sylmar, CA, USA).Materials and Methods
Standardized protocols were used to assess magnetic field interactions (translational attraction and torque; 3 T, worst case), MRI-related heating (1.5 and 3 T), artifacts (3 T; worst case) and functional changes (1.5 and 3 T) associated with MRI.Results
The magnetic field interactions were acceptable. MRI-related heating, which was studied at a relatively high, MR system-reported whole body averaged specific absorption rates, will not pose a hazard to the patient under the conditions used for testing. While artifacts were “moderate” in relation to the dimensions of the Argus II Retinal Prosthesis, optimization of MRI parameters can reduce the size of the artifacts. Exposures to MRI conditions at 1.5 and 3 T did not damage or alter the functional aspects of the Argus II Retinal Prosthesis.Conclusions
In consideration of the test results, a patient with the Argus II Retinal Prosthesis may undergo MRI at 1.5 T or 3 T when specific guidelines and MRI conditions are followed, including those advised by the manufacturer. 相似文献4.
Objective
Magnetic resonance spectroscopy (MRS) allows to monitor brain metabolites noninvasively in amyotrophic lateral sclerosis (ALS). The objective of this study was to use MRS to monitor the effect of minocycline treatment (200 mg/day) over a short period (6 weeks) on the brain metabolites in the precentral gyrus and brainstem in newly diagnosed ALS patients.Methods
Ten ALS patients (not on riluzole treatment) were recruited and submitted to single-voxel proton MRS longitudinal examinations (1) before minocycline treatment, (2) 3 weeks and (3) 6 weeks after initiation of treatment.Results
Results did not show the expected decrease of N-acetylaspartate/creatine (NAA/Cr) in the precentral gyrus, and an increased NAA/Cr ratio in the brainstem suggested neuronal recovery. The myo-inositol (mI)/Cr ratio was unchanged in the precentral gyrus, but increased in the brainstem, indicating a glial reaction.Conclusions
MRS results suggest that minocycline treatment could be beneficial in the early stages of ALS. 相似文献5.
Background
Since the advent of magnetic resonance imaging, metal artifacts have posed an important diagnostic problem in different fields of medicine. However, this has not been systematically studied in patients undergoing surgery for brain tumors.Objective
This study was planned to assess whether metal artifacts can occur in patients undergoing brain surgery without metallic implants.Methods
Of 40 individuals who could be included because of having a pre- and postoperative MRI and a postoperative computed tomography (CT) scan or a conventional skull X-ray for the detection of metallic artifacts, 26 patients agreed to participate in this study and gave informed consent.Results
Twenty-six subjects, 12 males and 14 females, with an age range of 12 to 54 years, were included in the study. Four patients were found to have gross metal particles in their postoperative brain CTs and were excluded. Of the remaining 22 subjects, 7 patients (31.8%) had metallic artifacts.Conclusion
Our study showed that simple bone drilling or chiseling during surgical manipulation of skull bones may result in separation of very tiny metal particles which can remain in the surgical site and cause artifacts in postoperative MRIs. This finding appeared to be independent of factors such as age, sex, tumor/incision site, tumor size, pathologic tumor type, total radiation dose, operation–MRI time interval and sequence of MRI. 相似文献6.
Background and Purpose
A recent report suggested that a serious burn injury was due to the presence of the identification (ID) wristband. As such, in lieu of removing or padding hospital ID wristbands in all patients prior to magnetic resonance imaging (MRI), testing may be performed to characterize risks for ID wristbands. Therefore, the purpose of this investigation was to evaluate the magnetic field interactions, heating and artifacts at 3 T for a hospital ID wristband.Materials and Methods
Standardized test methods were used to evaluate magnetic field interactions, MRI-related heating, and artifacts at 3 T for a hospital ID wristband.Results
There were no magnetic field interactions. MRI-related heating evaluated at a relatively high, MR system-reported, whole body-averaged specific absorption rate (2.9 W/kg) did not increase above the background level. The artifacts related to the ink used for printing were “small” for one toner and “large” for the other in relation to the dimensions of the printing.Conclusions
Based on the tests performed, this particular hospital ID wristband is considered MR safe and will not pose a hazard to a patient undergoing an MRI examination. Importantly, it is not necessary to remove this item for a patient referred for MRI. 相似文献7.
Eun Jeong Kim Sung Hun Kim Bong Joo Kang Byung Gil Choi Byung Joo Song Jae Jeong Choi 《Magnetic resonance imaging》2014
Purposes
To evaluate the diagnostic value of diffusion-weighted MRI (DWI) and combination of conventional MRI and DWI to predict metastatic axillary lymph nodes in breast cancer.Materials and methods
Two hundred fifty-two breast cancer patients with 253 axillae were included. The morphological parameters on axial T2-weighted images without fat saturation and apparent diffusion coefficient (ADC) values were retrospectively analyzed. An independent t-test/chi-square test and receiver operating characteristics (ROC) curve analysis were used.Results
On conventional MRI, short and long axis length, maximal cortical thickness, relative T2 value, loss of fatty hilum (p < 0.001 for each), and eccentric cortical thickening (p < 0.003) were statistically significantly different between the metastatic and nonmetastatic groups. The short axis to long axis ratio was not a statistically significant parameter. The ADC value was significantly different between the 2 groups, with an AUC that was higher than that of conventional MR parameters (AUC, 0.815; threshold, ≤ 0.986 × 10–3 mm2/sec; sensitivity, 75.8%; specificity, 83.9%). Using the adopted thresholds for each parameter, a total number of findings suggesting malignancy of 4 or higher was determined as the threshold, with high specificity (90.1%).Conclusion
Using conventional MRI and DWI, we can evaluate the axilla in breast cancer with high specificity. 相似文献8.
Sung Hun Kim Jafi A. Lipson Catherine J. Moran Ann Shimakawa James Kuo Debra M. Ikeda Bruce L. Daniel 《Magnetic resonance imaging》2013
Purpose
To compare the image quality of three techniques and diagnostic performance in detecting implant rupture.Materials and Methods
The study included 161 implants for the evaluation of image quality, composed of water-saturated short TI inversion recovery (herein called “water-sat STIR”), three-point Dixon techniques (herein called “Dixon”), and short TI inversion recovery fast spin-echo with iterative decomposition of silicone and water using least-squares approximation (herein called “STIR IDEAL”) and included 41 implants for the evaluation of diagnostic performance in detecting rupture, composed of water-sat STIR and STIR IDEAL.Six image quality categories were evaluated and three classifications were used: normal implant, possible rupture, and definite rupture.Results
Statistically significant differences were noted for the image quality categories (p < 0.001). STIR IDEAL was superior or equal to water-sat STIR in all image quality categories except artifact effects and superior to Dixon in all categories. Water-sat STIR performed the poorest for water suppression uniformity.The sensitivity and specificity in detecting implant rupture of STIR-IDEAL were 81.8 % and 77.8 % and the difference between two techniques was not statistically significant.Conclusion
STIR-IDEAL is a useful silicone-specific imaging technique demonstrating more robust water suppression and equivalent diagnostic accuracy for detecting implant rupture, than water-sat STIR, at the cost of longer scan time and an increase in minor motion artifacts. 相似文献9.
Yusuke Inoue Hirofumi Hata Ai Nakajima Yuji Iwadate Gou Ogasawara Keiji Matsunaga 《Magnetic resonance imaging》2014
Purpose
To optimize the navigator-gating technique for the acquisition of high-quality three-dimensional spoiled gradient-recalled echo (3D SPGR) images of the liver during free breathing.Materials and methods
Ten healthy volunteers underwent 3D SPGR magnetic resonance imaging of the liver using a conventional navigator-gated 3D SPGR (cNAV-3D-SPGR) sequence or an enhanced navigator-gated 3D SPGR (eNAV-3D-SPGR) sequence. No exogenous contrast agent was used. A 20-ms wait period was inserted between the 3D SPGR acquisition component and navigator component of the eNAV-3D-SPGR sequence to allow T1 recovery. Visual evaluation and calculation of the signal-to-noise ratio were performed to compare image quality between the imaging techniques.Result
The eNAV-3D-SPGR sequence provided better noise properties than the cNAV-3D-SPGR sequence visually and quantitatively. Navigator gating with an acceptance window of 2 mm effectively inhibited respiratory motion artifacts. The widening of the window to 6 mm shortened the acquisition time but increased motion artifacts, resulting in degradation of overall image quality. Neither slice tracking nor incorporation of short breath holding successfully compensated for the widening of the window.Conclusion
The eNAV-3D-SPGR sequence with an acceptance window of 2 mm provides high-quality 3D SPGR images of the liver. 相似文献10.
Thomas A. Hope John-Peder Escobar Kvitting Michael D. Hope D. Craig Miller Michael Markl Robert J. Herfkens 《Magnetic resonance imaging》2013
Background
Over the past two decades elective valve-sparing aortic root replacement (V-SARR) has become more common in the treatment of patients with aortic root and ascending aortic aneurysms. Currently there are little data available to predict complications in the post-operative population. The study goal was to determine if altered flow patterns in the thoracic aorta, as measured by MRI, are associated with complications after V-SARR.Methods
Time-resolved three-dimensional phase-contrast MRI (4D flow) was used to image 12 patients with Marfan syndrome after V-SARR. The patients were followed up for an average of 5.8 years after imaging and 8.2 years after surgery. Additionally 5 volunteers were imaged for comparison. Flow profiles were visualized during peak systole using streamlines. Wall shear stress estimates and normalized flow displacement were evaluated at multiple planes in the thoracic aorta.Results
During the follow-up period, a single patient developed a Stanford Type B aortic dissection. At initial imaging, prior to the development of the dissection, the patient had altered flow patterns, wall shear stress estimates, and increased normalized flow displacement in the thoracic aorta in comparison to the remaining V-SARR patients and volunteers.Conclusions
This is the first follow-up study of patients after 4D flow imaging. An aortic dissection developed in one patient with altered flow patterns and hemodynamic stresses in the thoracic aorta. These results suggest that flow and altered hemodynamics may play a role in the development of post-operative intramural hematomas and dissections. 相似文献11.
Purpose
To evaluate MRI artifacts at 3-Tesla for 38 commonly used cosmetics.Materials and Methods
Thirty-eight cosmetics (16, nail polishes; 5, eyeliners; 3, mascaras; 10, eye shadows; 1, lip gloss; 1, body lotion; 1, body glitter, and 1, hair loss concealer) underwent evaluation for MRI artifacts at 3-Tesla. The cosmetics were applied a copper-sulfate-filled, phantom and initially assessed using a “screening” gradient echo (GRE) pulse sequence. Of the 38 different cosmetics, 14 (37%) exhibited artifacts. For these 14 cosmetics, additional characterization of artifacts was performed using a GRE pulse sequence. A qualitative scale was applied to characterize the artifact size.Results
Artifacts were observed, as follows: 2, nail polishes; 5, eyeliners; 3, mascaras; 3, eye shadows; 1, hair loss concealer. Artifact size ranged from small (eye shadow) to very large (hair loss concealer) and tended to be associated with the presence of iron oxide or other metal-based ingredient.Conclusions
Commonly used cosmetics caused artifacts that may create issues if the area of interest is the same as where the cosmetic was applied or if its presence was unknown, thus, potentially causing it to be construed as pathology. Therefore, these findings have important implications for patients referred for MRI examinations. 相似文献12.
Background and Purpose
Fine-mesh braided, stent-like structures (flow diverters) have been proposed for treatment of brain aneurysms. To date, the safety of performing magnetic resonance imaging (MRI) in patients with these implants is unknown. Therefore, the purpose of this study was to evaluate MRI issues at 3-T for a new flow-diverting implant used to treat brain aneurysms.Methods
The Surpass NeuroEndoGraft (Surpass Medical, Ltd., Tel Aviv, Israel) underwent evaluation for magnetic field interactions, MRI-related heating and artifacts using standardized techniques. Magnetic field interactions were assessed for this implant with regard to translational attraction (i.e., using the deflection angle technique) and torque (qualitative assessment method). MRI-related heating was evaluated by placing the implant in a gelled-saline-filled, head/torso phantom and performing MRI using a transmit/receive radiofrequency body coil at a whole-body-averaged specific absorption rate of 2.9 W/kg for 15 min. Artifacts were characterized using T1-weighted, spin echo (SE) and gradient echo (GRE) pulse sequences.Results
The Surpass NeuroEndoGraft exhibited minor magnetic field interactions (21° deflection angle and no torque), which were acceptable from a safety consideration. Heating was not substantial, with the highest temperature change being 2.3°C (background temperature rise without the implant was 1.5°C). Artifacts may create issues if the area of interest is in the same area or close to this implant.Conclusions
The findings demonstrated that it would be acceptable for patients with this next-generation, flow-diverting implant to undergo MRI at 3-T or less. 相似文献13.
Hans-Peter Müller Heiko G. Niessen Thomas Kaulisch Albert C. Ludolph Jan Kassubek Detlef Stiller 《Magnetic resonance imaging》2013
Purpose
Body fat distribution changes are associated with multiple alterations in metabolism. Therefore, the assessment of body fat compartments by MRI in animal models is a promising approach to obesity research. Standard T1-weighted (T1w) whole body MRI was used here to quantify different effects in the subcutaneous and visceral fat compartments in rats under treatment with an anorexiant.Materials and methods
Twenty rats on a high caloric diet were investigated by the identical MRI protocol at baseline and after seven weeks. Ten rats received a treatment with sibutramine, 10 rats served as vehicle control group. To longitudinally assess body fat components, MRI analysis was used with two approaches: 2D slicewise graphic analysis (SGA) was compared with an automated 3D analysis algorithm (3DA).Results
At the group level, fat volume differences showed a longitudinal increase of subcutaneous and visceral fat volumes for the control group, whereas the sibutramine group showed stable subcutaneous fat volumes and decrease in visceral fat volumes. SGA and 3DA volume determination showed significant correlations for subcutaneous fat volume (C = 0.85, p < 0.001), visceral fat volume (C = 0.87, p < 0.001), and total fat volume (C = 0.90, p < 0.001).Conclusion
It could be demonstrated that computer-based analysis of T1w MRI could be used to longitudinally assess changes in body fat compartments in rats at the group level. In detail, it was possible to investigate the effect of sibutramine separate on the fat compartments in rats. 相似文献14.
Hirofumi Okuda Shigeru Matsushima Hideshi Sugiura Kenji Yamada Shunsuke Hamada Yoshihiro Nishida Naoki Ishiguro 《Magnetic resonance imaging》2014
Objective
Equivalent cross-relaxation rate imaging (ECRI) is an MRI technique used to evaluate qualitative changes in protein-water interactions. We aimed to prospectively evaluate the utility of ECRI for classification of adipocytic tumors.Materials and Methods
Institutional Review Board approval was obtained and all patients provided informed consent. Study participants included 40 patients with adipocytic tumors who were diagnosed with lipomas (n = 22), atypical lipomatous tissue/well-differentiated liposarcoma (ALT/WDL; n = 9), myxoid/round cell liposarcoma (MyL; n = 6), and dedifferentiated liposarcoma (DDL; n = 3), and 20 control patients for whom subcutaneous fat in the buttock or thigh was analyzed.Results
Mean ECR values of lipomas, ALT/WDL, and subcutaneous fat were low, and those of MyL and DDL were high. Mean ECR values of MyL and DDL were significantly higher than those of ALT/WDL. The cut-off value was 5.1%. There was a positive correlation between ECR value, pathological grade, and cell density in adipocytic tumors.Conclusion
The ECR value positively correlates with pathological grade and cell density of adipocytic tumors. Our findings suggest that ECRI is a useful method for preoperative evaluation of adipocytic tumors. 相似文献15.
Xiuzhong Yao Tiantao Kuang Li Wu Hao Feng Hao Liu Weizhong Cheng Shengxiang Rao He Wang Mengsu Zeng 《Magnetic resonance imaging》2014
Objectives
To investigate and optimize diffusion-weighted imaging (DWI) acquisitions for pancreatic cancer at 3.0 T.Methods
Forty-five patients with pancreatic cancer were examined by four DWI acquisitions with b values = 0 and 600 s/mm2 at 3.0 T, including breath-holding DWI (BH-DWI), respiratory-triggered DWI (TRIG-DWI), respiratory-triggered DWI with inversion–recovery technique (TRIGIR-DWI), and free-breathing DWI with inversion–recovery technique (FBIR-DWI). Artifacts, contrast ratio (CR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) of pancreatic cancer were statistically compared among DWI acquisitions.Results
TRIGIR-DWI displayed the lowest artifacts and highest CR compared to other DWI acquisitions. CNRs of pancreatic cancer in TRIG-DWI and TRIGIR-DWI were statistically higher than that in FBIR-DWI and BH-DWI. Different ADCs between pancreatic cancer and noncancerous pancreatic tissues were noticed by a paired-samples T test in TRIG-DWI (p = 0.017), TRIGIR-DWI (p = 0.00001) and FBIR-DWI (p = 0.000041).Conclusions
TRIGIR-DWI may be the optimal acquisition of DWI for pancreatic cancer at 3.0 T. 相似文献16.
Sharma R 《Magnetic resonance imaging》2009,27(2):240-255
Purpose
Quantitative imaging of the rat skin was performed using magnetic resonance imaging (MRI) at 900 MHz.Materials and methods
A number of imaging techniques utilized for multiple contrast included magnetization transfer contrast, spin-lattice relaxation constant (T1-weighting), combination of T2-weighting with magnetic field inhomogeneity (T2*-weighting), magnetization transfer weighting and diffusion tensor weighting. These were used to obtain 2D slices and 3D multislice-multiecho images with high magnetic resonance contrast. These 2D and 3D imaging techniques were combined to achieve high-resolution MRI.Results
Oil–water phantom showed distinct fat-water contrast. The dermis and epidermis, including the stratum corneum remnants, of nude rat skin were distinct due to their proton magnetic resonance as a result of proton interactions with the skin interstitial tissue. Combined details obtained from high-resolution, high-quality ex vivo skin images with different multicontrast characteristics generated better differentiation of skin layers, sublayers and significant correlation (r2=0.4927 for MRI area, r2=0.3068 for histology area; P<.0148) of MR data with co-registered histological areas of the epidermis as well as the hair follicle.Conclusion
The multiple contrast approach provided a noninvasive ex vivo MRI visualization with semi-quantitative assessment of the major skin structures including the stratum corneum remnants, epidermis, hair, papillary dermis, reticular dermis and hypodermis. 相似文献17.
Kolk A Pautke C Wiener E Schott V Wolff KD Horch HH Rummeny EJ 《Magnetic resonance imaging》2008,26(8):1167-1174
Objective
The cause of enophthalmos as a late complication after orbital reconstruction is poorly investigated. Multislice CT (MSCT) is usually employed for its assessment, in spite of limitations regarding soft tissue depiction/imaging, as well as the implication of radiation and production of artifacts. Magnetic resonance imaging (MRI) has been shown to be a valuable alternative. The aim of this study was to establish a bony and soft tissue orbital volume calculation method based on different high-resolution MRI sequences compared to MSCT.Materials and Methods
Thirty-seven patients were included in this prospective study investigating the origin of enophthalmos present 3–4 months after complex orbital reconstruction. Morphological and dimensional changes of the orbit, eye globes, extraocular muscles and fat content were investigated 3–4 months after surgery. To assess the site and size of bony and soft tissue changes in the traumatized orbits, we used MSCT and MR images as well as corresponding 3-D reconstructions.Results
All enophthalmic orbits revealed a significant bony volume increase compared to the contralateral side as well as a reduced sagittal eye projection. Mean orbital volume enlargements of 1.0 cm3 lead to 0.93 mm enophthalmos (P<.05). Hardly any fatty atrophy could be depicted by the different MRI techniques.Conclusions
For soft tissue depiction of the orbit, MRI was superior to MSCT. Particularly, proton density weighting proved to be the best sequence for soft tissue volume segmentation, allowing determination of the cause and degree of posttraumatic enophthalmos in reconstructed orbits. 相似文献18.
Laurence Gury-Paquet Antoine Millon Fatima Salami Alexandru Cernicanu Jean-Yves Scoazec Philippe Douek Loïc Boussel 《Magnetic resonance imaging》2012
Purpose
To assess the sensitivity and specificity of intra-plaque hemorrhage (IPH), large lipid-rich necrotic core (LR-NC) and ulceration or cap rupture (UCR) for symptomatic carotid plaque characterization and to evaluate a new imaging score [Hemorrhage, Ulceration or cap rupture, Lipid-rich necrotic Core (HULC) score based on the sum of presence/absence of IPH, UCR and LR-NC; range 0–3] for assessment of recently symptomatic carotid plaques.Material and methods
Twenty-seven recently symptomatic (< 8 weeks) and 36 asymptomatic patients with a carotid plaque thicker than 2 mm were prospectively imaged on a 3-T magnetic resonance (MR) system using high-resolution, multi-contrast MR sequences. Prior to analysis, all images were reviewed to assess image quality of each sequence. Sensitivity and specificity of IPH, LR-NC, UCR and HULC scores were calculated.Results
Fifty-one patients were analyzed (26 symptomatic carotids and 67 asymptomatic carotids) after exclusion of studies with poor image quality. Sensitivity and specificity for symptomatic carotid plaque was, respectively, 46.1% and 97% for IPH, 84.6% and 73.1% for UCR and 80.7% and 76.1% for LR-NC. A HULC score of 2 or more showed a sensitivity of 73% and a specificity of 92.5%.Conclusion
At 3 T, intra-plaque hemorrhage is the most specific criterion to characterize symptomatic carotid plaque. The HULC score offers the best compromise between sensitivity and specificity. 相似文献19.
Liana Sanches-Rocha Bruna Serpa Eduardo Figueiredo Nelson Hamerschlak Ronaldo Baroni 《Magnetic resonance imaging》2013
Purpose
To test a magnetic resonance image (MRI) technique that uses an additional pulse in multi-echo T2* sequence that works to suppress the fat signal, in subjects with liver iron overload and concomitant presence of fat in the liver, which have been revealed as a major drawback that compromises the correct iron quantification by MRI.Materials and Methods
Fifty magnetic resonance images of the liver (1.5 T scanner) of individuals with blood ferritin increases were retrospectively reviewed for the presence of steatosis, using the sequence in and out of phase, and iron overloading, using two sequences T2 * multi-echo: one standard and other with additional fat suppression pulse. T2 * values and their standard deviations were analyzed statistically.Results
Our results showed that a significantly lower standard deviation of T2* values is obtained when the fat saturation pulse is applied in patients with steatosis. We found that modulation of fat signal on liver iron overload resulted in a different categorization of some patients. In one case, the patient was re-classified within normal levels of liver iron.Conclusion
Our findings may contribute to a better measure of liver iron overload with relevant implications for patient treatment and care. 相似文献20.
Francesco Somma Daniela Berritto Francesca Iacobellis Nicola Landi Carlo Cavaliere Marco Corona Serena Russo Roberto Di Mizio Antonio Rotondo Roberto Grassi 《Magnetic resonance imaging》2013