共查询到9条相似文献,搜索用时 0 毫秒
1.
J.H. Espina-Hernndez R. Grssinger J.M. Hallen 《Journal of magnetism and magnetic materials》2008,320(14):e300-e303
This work presents new eddy current measurements in pulsed fields. A commercial point pick-up coil is used to detect the induction signal along the radius of Cu and Al samples with cylindrical shape and diameters between 5 and 35 mm. Local eddy current measurements were performed on the surface of conducting materials due to the small dimensions of the coil. A simple electrical circuit, used as a model, is proposed to describe the local eddy current effect in pulsed fields. The proposed model allows to calculate the phase shift angle between the signal proportional to eddy currents and the applied external field in a pulsed field magnetometer. 相似文献
2.
Eddy current-induced geometric distortions of single-shot, diffusion-weighted, echo-planar (DW-EP) images are a major confounding factor to the accurate determination of water diffusion parameters in diffusion tensor MRI (DT-MRI). Previously, it has been suggested that these geometric distortions can be removed from brain DW-EP images using affine transformations determined from phantom calibration experiments using iterative cross-correlation (ICC). Since this approach was first described, a number of image-based registration methods have become available that can also correct eddy current-induced distortions in DW-EP images. However, as yet no study has investigated whether separate eddy current calibration or image-based registration provides the most accurate way of removing these artefacts from DT-MRI data. Here we compare how ICC phantom calibration and affine FLIRT (http://www.fmrib.ox.ac.uk), a popular image-based multi-modal registration method that can correct both eddy current-induced distortions and bulk subject motion, perform when registering DW-EP images acquired with different slice thicknesses (2.8 and 5 mm) and b-values (1000 and 3000 s/mm(2)). With the use of consistency testing, it was found that ICC was a more robust algorithm for correcting eddy current-induced distortions than affine FLIRT, especially at high b-value and small slice thickness. In addition, principal component analysis demonstrated that the combination of ICC phantom calibration (to remove eddy current-induced distortions) with rigid body FLIRT (to remove bulk subject motion) provided a more accurate registration of DT-MRI data than that achieved by affine FLIRT. 相似文献
3.
Udomchai Techavipoo John Lackey Jianrong Shi Xin Guan Song Lai 《Magnetic resonance imaging》2009,27(9):1281-1292
Diffusion tensor imaging requires correction of eddy current distortion in diffusion-weighted images. An effective retrospective correction approach is to transform a diffusion-weighted image to maximize the mutual information (MI) between the transformed diffusion-weighted image and the corresponding T2-weighted image. In the literature, either linear interpolation or partial volume interpolation is applied to estimate the MI objective function. However, these interpolation methods induce artifacts to the MI objective function, thus compromising correction results. In this work, the MI objective function is estimated based on interpolation using Fourier shift theorem. This method eliminates the artifacts incurred with the aforementioned interpolation methods. The algorithm is further improved by approximating pixel values using their nearest neighbors in the up-sampled spatial domain, resulting in dramatically increased computational efficiency without compromising the correction results. The effects of varying the number of quantization levels and using Parzen window filtering to smooth the MI objective function are also investigated to obtain optimized algorithm parameters. The diffusion tensor image quality after applying the proposed distortion correction method is significantly improved visually. 相似文献
4.
5.
Exact analytical expressions for forces on moving rectangular current-carrying coils above and below an infinite conducting
sheet track of arbitrary thickness are developed. These general expressions for the lift and drag forces acting on the excitation
coils as functions of speed are investigated for normal flux, null flux and brake flux systems and discussed with the aid
of numerical calculations. A concise parameter study is also made. The system velocity characteristics with constant load
(technologically more relevant) are given for the first time for normal and null flux systems. 相似文献
6.
Elevations of diffusion anisotropy are associated with hyper-acute stroke: a serial imaging study 总被引:1,自引:0,他引:1
Bhagat YA Hussain MS Stobbe RW Butcher KS Emery DJ Shuaib A Siddiqui MM Maheshwari P Al-Hussain F Beaulieu C 《Magnetic resonance imaging》2008,26(5):683-693
Diffusion tensor imaging (DTI) studies of human ischemic stroke within 24 h of symptom onset have reported variable findings of changes in diffusion anisotropy. Serial DTI within 24 h may clarify these heterogeneous results. We characterized longitudinal changes of diffusion anisotropy by analyzing discrete ischemic white matter (WM) and gray matter (GM) regions during the hyperacute (2.5-7 h) and acute (21.5-29 h) scanning phases of ischemic stroke onset in 13 patients. Mean diffusivity (MD), fractional anisotropy (FA) and T2-weighted signal intensity were measured for deep and subcortical WM and deep and cortical GM areas in lesions outlined by a > or =30% decrease in MD. Average reductions of approximately 40% in relative (r) MD were observed in all four brain regions during both the hyperacute and acute phases post stroke. Overall, 9 of 13 patients within 7 h post symptom onset showed elevated FA in at least one of the four tissues, and within the same cohort, 11 of 13 patients showed reduced FA in at least one of the ischemic WM and GM regions at 21.5-29 h after stroke. The fractional anisotropy in the lesion relative to the contralateral side (rFA, mean+/-S.D.) was significantly elevated in some patients in the deep WM (1.10+/-0.11, n=4), subcortical WM (1.13+/-0.14, n=4), deep GM (1.07+/-0.06, n=1) and cortical GM (1.22+/-0.13, n=5) hyperacutely (< or =7 h); however, reductions of rFA at approximately 24 h post stroke were more consistent (rFA= 0.85+/-0.12). 相似文献
7.
Masaharu Komiyama Tomoya Fujimura Toshimi Takagi Shinichi Kinoshita 《Proceedings of the Combustion Institute》2005,30(1):465-473
Instantaneous and simultaneous measurements of two-dimensional temperature and OH-LIF profiles by combining Rayleigh scattering with laser induced fluorescence (LIF) were demonstrated in a nitrogen-diluted hydrogen (H2 30% + N2 70%) laminar normal diffusion flame interacting with a large-scale vortex by oscillating central fuel flow or in an inverse diffusion flame by oscillating central airflow. The dynamic behavior of the diffusion flame extinction and reignition during the flame–vortex interaction processes was investigated. The results obtained are described as follows. (1) The width of the reaction zone decreases remarkably, and a decrease in flame temperature and OH-LIF is seen with increasing central airflow in an inverse diffusion flame. OH-LIF increases, and temperature does not change with increasing central fuel flow in a normal diffusion flame. The computations predict the experimental results well, and it is revealed that flame temperature characteristics result from the preferential diffusion of heat and species, which induces excess enthalpy or on enthalpy deficit, and an increase or decrease in H2 mole fraction in the flame. (2) When a large velocity fluctuation is given to the central flow, the temperature and the OH-LIF at the reaction zone become thin at the convex and circumferential part of the vortex where a high temperature layer exists, and the temperature at the reaction zone is lowered in the inverse flame and the normal flame. (3) The width and temperature of the reaction zone interacting with the vortex recover quickly to that of the laminar steady flame after the vortex passing in the normal flame, but the recovery to that of the steady flame after the vortex passing is delayed in the inverse flame. (4) When a remarkably large velocity fluctuation is given to the central airflow in the inverse flame, thinning of temperature and reaction zone starts at the convex and circumferential part of the vortex, resulting in a and flame extinction completely occurs at the tail part of the vortex and makes the pair of edge flames. The outside edge flame reignites and connects with the upstream reaction zone. The inside edge flame finally extinguishes as the supply of fuel is interrupted by the outside edge flame. 相似文献
8.
Mori N Miki Y Fushimi Y Kikuta K Urayama S Okada T Fukuyama H Hashimoto N Togashi K 《Magnetic resonance imaging》2008,26(6):835-840
Moyamoya disease (MMD) is a rare disorder of unknown etiology in which terminal portions of the internal carotid arteries become steno-occlusive, with fine collateral "moyamoya vessels" formed secondarily, resulting in serial ischemic strokes throughout its clinical course. Whole-brain histogram (WBH) of diffusion tensor imaging (WBH-DTI) is an analytical tool whose feasibility has been ascertained in various pathologies. To elucidate whether WBH-DTI could detect any difference between ischemic MMD and normal controls, we examined 27 consecutive MMD patients without hemorrhage and 48 normal controls in this prospective study using a 3.0-T magnetic resonance scanner. WBHs of fractional anisotropy (FA) (WBH-FA) and mean diffusivity (MD) (WBH-MD) were compared among three groups: Group 1, MMD patients with infarct (n=15); Group 2, MMD patients without infarct (n=12); and Group 3, normal controls (n=48). Group 1 showed significantly higher peak height and significantly lower mean value on WBH-FA, as well as significantly lower peak height and significantly higher mean value on WBH-MD, compared with Groups 2 and 3. No significant difference was seen in parameters at either WBH-FA or WBH-MD between Groups 2 and 3. These results might reflect the pathological severity of each group, and WBH-DTI could feasibly detect differences between ischemic MMD with infarction and MMD without infarction and normal controls. 相似文献
9.
Mode shift and stability control of a current mode controlled buck-boost converter operating in discontinuous conduction mode with ramp compensation
下载免费PDF全文
![点击此处可从《中国物理 B》网站下载免费的PDF全文](/ch/ext_images/free.gif)
By establishing the discrete iterative mapping model of a
current mode controlled buck-boost converter, this paper studies the
mechanism of mode shift and stability control of the buck-boost
converter operating in discontinuous conduction mode with a ramp
compensation current. With the bifurcation diagram, Lyapunov
exponent spectrum, time-domain waveform and parameter space map, the
performance of the buck-boost converter circuit utilizing a
compensating ramp current has been analysed. The obtained results
indicate that the system trajectory is weakly chaotic and strongly
intermittent under discontinuous conduction mode. By using ramp
compensation, the buck-boost converter can shift from discontinuous
conduction mode to continuous conduction mode, and effectively
operates in the stable period-one region. 相似文献