首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This work presents a simple design for a mobile single-sided nuclear magnetic resonance (NMR) apparatus with a relatively homogeneous static magnetic field (B0) distribution. In the proposed design, the B0 magnetic field of the apparatus is synthesized using only two permanent magnet blocks, i.e., a cube (main) magnet and a small shim magnet placed above the main magnet. The magnetic flux of the shim magnet partially cancels out that of the main magnet, subsequently creating a smooth B0 profile above the shim magnet where low-resolution NMR experiments are performed. Compared with many previously published designs, this straightforward design simplifies the construction of the apparatus and simultaneously generates a B0 field parallel to the apparatus surface, allowing the use of a simple loop-type radiofrequency (RF) coil. Additionally, an apparatus prototype is constructed according to the proposed design. Weighing only 1.8 kg, the constructed apparatus has a compact structure and can be held in the palm of a hand. The apparatus generates a B0 strength of about 0.0746 T. Within a B0 field deviation of 3 mT, the region with a relatively homogeneous B0 distribution extends to about 11 mm above the shim magnet. The proposed apparatus can detect a clear Hahn echo or Carr-Purcell-Meiboom-Gill (CPMG) echoes of a pencil eraser block or a bottle of oil placed on the apparatus in 5 s with signal averaging using an RF transmitter power of only 19 W; the detection range of the apparatus exceeds 6 mm. The strength of the residual static magnetic field gradient of the apparatus is roughly estimated at 0.58 T/m. Applying different CPMG echo spacings in this residual static gradient leads to various transverse relaxation time (T2) contrasts for liquids with distinct viscosities such as water and oil. Two nondestructive inspection applications of the apparatus, including correlating the concentrations of magnetic nanoparticle solutions with their measured transverse relaxation rates (R2) and monitoring the outgassing from an opened bottle of oxygen-supersaturated water by measuring its longitudinal relaxation rate (R1), are also demonstrated.  相似文献   

2.
唐昕  洪礼明  俎栋林 《中国物理 B》2010,19(7):78702-078702
This paper presents an approach of active ferromagnetic shimming for C-type permanent magnetic resonance imaging (MRI) magnet.It is designed to reduce inhomogeneity of magnetostatic field of C-type permanent magnet to meet the stringent requirement for MRI applications.An optimal configuration (locations and thicknesses) of active ferromagnetic pieces is generated through calculation according to the initial field map and the demanded final homogeneity specifications.This approach uses a minimisation technique which makes the sum of squared magnetic moment minimum to restrict the amount of the active ferromagnetic material used and the maximal thickness of pieces stacked at each hole location in the shimming boards.Simulation and experimental results verify that the method is valid and efficient.  相似文献   

3.
俎栋林  郭华  宋枭禹  包尚联 《中国物理》2002,11(10):1008-1012
The approach of expanding the magnetic scalar potential in a series of Legendre polynomials is suitable for designing a conventional superconducting magnetic resonance imaging magnet of distributed solenoidal configuration. Whereas the approach of expanding the magnetic vector potential in associated Legendre harmonics is suitable for designing a single-solenoid magnet that has multiple tiers, in which each tier may have multiple layers with different winding lengths. A set of three equations to suppress some of the lowest higher-order harmonics is found. As an example, a 4T single-solenoid magnetic resonance imaging magnet with 4×6 layers of superconducting wires is designed. The degree of homogeneity in the 0.5m diameter sphere volume is better than 5.8 ppm. The same degree of homogeneity is retained after optimal integralization of turns in each correction layer. The ratio Bm/B0 in the single-solenoid magnet is 30% lower than that in the conventional six-solenoid magnet. This tolerates higher rated superconducting current in the coil. The Lorentz force of the coil in the single-solenoid system is also much lower than in the six-solenoid system. This novel type of magnet possesses significant advantage over conventional magnets, especially when used as a super-high field functional magnetic resonance imaging magnet.  相似文献   

4.
Modeling of water diffusion in white matter is useful for revealing microstructure of the brain tissue and hence diagnosis and evaluation of white matter diseases. Researchers have modeled diffusion in white matter using mathematical and mechanical analysis at the cellular level. However, less work has been devoted to evaluate these models using macroscopic real data such as diffusion tensor magnetic resonance imaging (DTMRI) data. DTMRI is a noninvasive tool for evaluating white matter microstructure by measuring random motion of water molecules referred to as diffusion. It reflects directional information of microscopic structures such as fibers. Thus, it is applicable for evaluation and modification of mathematical models of white matter. Nevertheless, a realistic relation between a fiber model and imaging data does not exist. This work opens a promising avenue for relating DTMRI data to microstructural parameters of white matter. First, we propose a strategy for relating DTMRI and fiber model parameters to evaluate mathematical models in light of real data. The proposed strategy is then applied to evaluate and extend an existing model of white matter based on clinically available DTMRI data. Next, the proposed strategy is used to estimate microstructural characteristics of fiber tracts. We illustrate this approach through its application to approximation of myelin sheath thickness and fraction of volume occupied by fibers. Using sufficiently small imaging voxels, the proposed approach is capable of estimating model parameters with desirable precision.  相似文献   

5.
邓东阁  左苏  武新军 《物理学报》2018,67(17):178103-178103
便捷获取铁磁承载构件应力对维护基础设施安全具有重要意义.其关键在于准确快速地确定随应力变化灵敏度高、线性度好的表征参数.现有电磁检测法一般在时变磁场线圈激励下,逐点分析实验结果来确定合适的表征参数,会带来线圈发热、涡流影响结果的问题,表征磁参数的确立繁琐.为此,本文提出基于表面磁感应强度的铁磁构件应力恒磁表征方法,采用永磁恒定磁化器产生全局衰减局部均匀的空间变化磁场作激励,用正交磁场测量单元拾取构件表面轴向和法向磁感应强度以表征应力.着重阐述基于表面磁感应强度的应力表征原理:根据退磁场理论、磁场强度切向连续性和磁场高斯定理,建立表面轴向和法向磁感应强度关于应力导函数之间的关系方程.最后开展实验验证.结果表明:根据该关系方程可快速准确地确定随应力灵敏度最高的表面磁感应强度,且其随应力变化线性度较好,拟合优度R2大于0.98,可作为应力表征磁参数.本文所提方法可为在线检测铁磁构件应力提供新途径.  相似文献   

6.
A new method for the ultrafast generation of diffusion-weighted images is reported. The technique combines a quick echo split NMR imaging sequence with the principle of Stejskal and Tanner. It allows to determine the diffusion constant with nearly the same accuracy as the conventional spin-echo technique, requiring only a fraction of the time. The determined values for water doped with 1 g Cu(NO3)2 per liter of H2O and pure acetone were Dwater = (1.95 ± 0.02) × 10−9 m2/s and Dacetone = (4.05 ± 0.02) × 10−9 m2/s at 18.5°C. They are in good agreement both with literature and our own reference measurements using a diffusion-weighted spin-echo sequence. In addition, the temperature dependence of Dwater was measured in the range of 18.5–45.9°C and a good correspondence with reported data was found.  相似文献   

7.
Hou-Rong Zhou 《中国物理 B》2022,31(5):57401-057401
Superconducting nanowire single-photon detectors (SNSPDs) are typical switching devices capable of detecting single photons with almost 100% detection efficiency. However, they cannot determine the exact number of incident photons during a detection event. Multi-pixel SNSPDs employing multiple read-out channels can provide photon number resolvability (PNR), but they require increased cooling power and costly multi-channel electronic systems. In this work, a single-flux quantum (SFQ) circuit is employed, and PNR based on multi-pixel SNSPDs is successfully demonstrated. A multi-input magnetically coupled DC/SFQ converter (MMD2Q) circuit with a mutual inductance M is used to combine and record signals from a multi-pixel SNSPD device. The designed circuit is capable of discriminating the amplitude of the combined signals in accuracy of Φ0/M with Φ0 being a single magnetic flux quantum. By employing the MMD2Q circuit, the discrimination of up to 40 photons can be simulated. A 4-parallel-input MMD2Q circuit is fabricated, and a PNR of 3 is successfully demonstrated for an SNSPD array with one channel reserved for the functional verification. The results confirm that an MMD2Q circuit is an effective tool for implementing PNR with multi-pixel SNSPDs.  相似文献   

8.
Firstly, an X-band relativistic backward wave oscillator with a low guiding magnetic field is simulated, whose output microwave power is 520 MW. Then, an experiment is carried out on an accelerator to investigate a relativistic backward wave oscillator with a permanent magnetic field whose strength is 0.46 T. When the energy of the electron is 630 keV and the current of the electron beam is 6.7 kA, a 15 ns width pulsed microwave with 510 MW output power at 8.0 GHz microwave frequency is achieved.  相似文献   

9.
An approach that enables the acquisition of multidimensional NMR spectra within a single scan has been recently proposed and demonstrated. The present paper explores the applicability of such ultrafast acquisition schemes toward the collection of two-dimensional magnetic resonance imaging (2D MRI) data. It is shown that ideas enabling the application of these spatially encoded schemes within a spectroscopic setting, can be extended in a straightforward manner to pure imaging. Furthermore, the reliance of the original scheme on a spatial encoding and subsequent decoding of the evolution frequencies endows imaging applications with a greater simplicity and flexibility than their spectroscopic counterparts. The new methodology also offers the possibility of implementing the single-scan acquisition of 2D MRI images using sinusoidal gradients, without having to resort to subsequent interpolation procedures or non-linear sampling of the data. Theoretical derivations on the operational principles and imaging characteristics of a number of sequences based on these ideas are derived, and experimentally validated with a series of 2D MRI results collected on a variety of model phantom samples.  相似文献   

10.
There has been much recent interest in extending the technique of magnetic resonance imaging (MRI) down to the level of single spins with sub-optical wavelength resolution. However, the signal to noise ratio for images of individual spins is usually low and this necessitates long acquisition times and low temperatures to achieve high resolution. An exception to this is the nitrogen-vacancy (NV) color center in diamond whose spin state can be detected optically at room temperature. Here we apply MRI to magnetically equivalent NV spins and demonstrate fully resolved spectra with resolution well below the optical wavelength of the readout light. In addition, using a microwave version of MRI we achieved a resolution that is 1/270 in size of the coplanar striplines, which define the effective wavelength of the microwaves that were used to excite the transition. This technique can eventually be extended to imaging of large numbers of NVs in a confocal spot and possibly to image nearby dark spins via their mutual magnetic interaction with the NV spin.  相似文献   

11.
In severe perinatal asphyxia, the prognostic value of apparent diffusion coefficient (ADC) measurements is still open to question. We hypothesized that temporal and anatomical changes of brain ADC values occurring early after the hypoxic-ischemic insult could predict the outcome at 36 months. To demonstrate this, mean ADC values were calculated for 16 brain structures in 59 term neonates who underwent an MR examination during the first month of life. Neonates were divided into two groups according to their 36-month outcome: unfavorable (death/severe disability) or favorable outcome. ADC values were plotted against age at scan.In neonates with favorable outcomes (n=32), ADC values were constant over the study period. In babies with unfavorable outcomes (n=27), ADCs exhibited two different patterns. In infratentorial structures, ADCs were constant and normal. In supratentorial areas, ADCs followed a biphasic temporal evolution: ADC values were at their lowest at day 2, showed a rapid increase until Days 5-7, and were thereafter similar to those of neonates with favorable outcomes. Using receiver operating characteristic analysis, during the first 3-5 days of life, all neonates with decreased ADC had an unfavorable outcome.These temporal and anatomical changes of ADC values imply that individual prognosis of asphyxiated neonates can only be predicted by measurement of ADC in supratentorial areas within the first 3-5 days of life.  相似文献   

12.

Purpose

To evaluate the use of the intravoxel incoherent motion (IVIM) technique in half-Fourier single-shot turbo spin-echo (HASTE) diffusion-weighted imaging (DWI), and to compare its accuracy to that of apparent diffusion coefficient (ADC) to predict malignancy in head and neck tumors.

Patients and methods

HASTE DW images of 33 patients with head and neck tumors (10 benign and 23 malignant) were evaluated. Using the IVIM technique, parameters (D, true diffusion coefficient; f, perfusion fraction; D*, pseudodiffusion coefficient) were calculated for each tumor. ADC values were measured over a range of b values from 0 to 1000 s/mm2. IVIM parameters and ADC values in benign and malignant tumors were compared using Student's t test, receiver operating characteristics (ROC) analysis, and multivariate logistic regression modeling.

Results

Mean ADC and D values of malignant tumors were significantly lower than those of benign tumors (P < 0.05). Mean D* values of malignant tumors were significantly higher than those of benign tumors (P < 0.05). There was no significant difference in mean f values between malignant and benign tumors (P > 0.05). The technique of combining D and D* was the best for predicting malignancy; accuracy for this model was higher than that for ADC.

Conclusions

The IVIM technique may be applied in HASTE DWI as a diagnostic tool to predict malignancy in head and neck masses. The use of D and D* in combination increases the diagnostic accuracy in comparison with ADC.  相似文献   

13.
More than a dozen Nuclear Magnetic Resonance (NMR) imaging methods have been described using different radio-frequency pulse sequences, magnetic field gradient variations, and data processing. In order to have a theoretical understanding in the most general case, we have conceived a computer program for the simulation of NMR imaging techniques. The algorithm uses the solution of the Bloch equations at each point of a simulated object. The direction of every elementary magnetic moment is computed at each instant, and stored in an array giving the global signal to be processed, whatever the pulse and gradient sequence. To test the validity of this program, we have simulated some well-known experimental results. Some applications are presented which contribute to the understanding of image distortions and to techniques such as selective radio-frequency pulse or oscillating gradients. This program can be used to unravel physical and technological causes of image distortions, to have a "microscopic" look at any parameter of an experiment, and to study the contrast given by various NMR imaging techniques as a function of the three NMR parameters, i.e., the hydrogen nuclei density rho and the relaxation times T1 and T2.  相似文献   

14.
Images of the rat head reflecting glucose utilization were obtained using 2-fluoro-2-deoxy-D-glucose (2-FDG) and 19F nuclear magnetic resonance (NMR) imaging. Spatial heterogeneity of glucose utilization in the rat head was clearly demonstrated showing significantly higher glucose utilization in the brain as compared to the surrounding tissues. Although the potential adverse effects of the high doses of 2-FDG (400 mg/kg) needed to perform the study preclude immediate application of this technique to clinical quantitative glucose utilization studies, the present study shows potential for future development of glucose utilization imaging by NMR.  相似文献   

15.
16.
The detection of samples in a microfluidic nuclear magnetic resonance chip is generally performed under flow condition. To study the effect of sample flow on the apparent transverse relaxation time in a microfluidic nuclear magnetic resonance chip, theoretical calculations were performed on three microfluidic samples (including deionized water, absolute ethanol, and copper sulfate pentahydrate) for flow velocities in the range 1.7–25?mm/s. A microfluidic nuclear magnetic resonance device with a low cost microfluidic solenoid coil was fabricated to verify the theoretical calculations by experiments. The results show that the apparent transverse relaxation time of the sample is a monoexponential decay with respect to flow velocity. In addition, it was found that the experimental values and the theoretical values of the apparent transverse relaxation time are identical when the samples are prepolarized completely; but for the samples that are not prepolarized completely, all the experimental values are smaller than the theoretical values and their difference increases with the flow velocity of the sample. After further study, it was discovered that the relative error between the experimental values and the theoretical values is a monoexponential decay to the level of the sample to be prepolarized. This discovery is very useful, because it can be used to modify the theoretical calculation model of the apparent transverse relaxation time for the samples that are prepolarized incompletely, as well as improve the application of microfluidics on nuclear magnetic resonance.  相似文献   

17.
Diffusion weighted magnetic resonance imaging (DWI) has been mostly acquired using single-shot echo-planar imaging (ss EPI) to minimize motion induced artifacts. The spatial resolution, however, is inherently limited in ss EPI especially for abdominal imaging, even with the advances in parallel imaging. A novel method of reduced Field of View ss EPI (rFOV ss EPI) has achieved high resolution DWI in human carotid artery, spinal cord with reduced blurring and higher spatial resolution than conventional ss EPI, but it has not been used to pancreas imaging. In the work, comparisons between the full FOV ss-DW EPI and rFOV ss-DW EPI in image qualities and ADC values of pancreatic tumors and normal pancreatic tissues were performed to demonstrate the feasibility of pancreatic high resolution rFOV DWI. There were no significant differences in the mean ADC values between full FOV DWI and rFOV DWI for the 17 subjects using b = 600 s/mm2 (P = 0.962). However, subjective scores of image quality was significantly higher at rFOV ss DWI (P = 0.008 and 0.000 for b-value = 0 s/mm2 and 600 s/mm2 respectively). The spatial resolution of DWI for pancreas was increased by a factor of over 2.0 (from almost 3.0 mm/pixel to 1.25 mm/pixel) using rFOV ss EPI technique. Reduced FOV ss EPI can provide good DW images and is promising to benefit applications for pancreatic diseases.  相似文献   

18.
The purpose of this study was to determine whether proton magnetic resonance spectroscopy (PMRS) and diffusion tensor imaging (DTI) indices, fractional anisotropy (FA) and mean diffusivity (MD) can be used to distinguish brain abscess from cystic brain tumors, which are difficult to distinguish by conventional magnetic resonance imaging (MRI). Fifty-three patients with intracranial cystic mass lesions and 10 normal controls were studied. Conventional MRI, PMRS and DTI of all the patients were performed on a 1.5-T GE scanner. Forty patients were with brain abscess and 13 with cystic tumors. Cytosolic amino acids (AAs) were present in 32 of 40 brain abscess patients. Out of 13 patients with cystic tumors, lactate and choline were seen in 3 and only lactate was present in 10 patients on PMRS. All 40 cases of abscess had high FA, while all 13 cases of tumor cysts had high MD values. We conclude that FA measurements are more sensitive in predicting the abscess, while PMRS and MD are more specific in differentiating abscess from cystic tumors. We suggest that PMRS should be combined with DTI rather than with diffusion-weighted imaging as FA can be used as an additional parameter for separation of abscess from other cystic intracranial mass lesions.  相似文献   

19.
The 1H and 2H spin-lattice relaxation times in the monohydride phase of the V-H-D and Ti0.1V0.9-H-D systems have been re-analyzed by Bloembergen-Purcell-Pound (BPP) equations with a log-normal distribution of correlation times, and the obtained parameters have been compared with those of the Ti0.33V0.67-H-D system. The mean activation energy and the magnitude of the distribution of H and D diffusions are discussed in relation to the metal compositions, the hydrogen site, the crystal structure and the [H]/[D] ratios.  相似文献   

20.
NMR velocimetry has been used to observe the steady-shear rheological behaviour of a concentrated suspension of hard-sphere like 370 nm diameter PMMA core-shell latex particles at the volume fraction Φ = 0.46, the liquid core of the spheres rendering possible NMR observation of the particles themselves. Rheological measurements in a cone-and-plate geometry indicate that when aged (i.e. left at rest for two weeks), the material exhibits yield stress behaviour at very low shear rates. For shear rates greater than 1 s - 1 a transition to liquid-like behaviour was observed, leading to a rejuvenated fluid state which exhibits shear-thinning behaviour over a wide range of shear rates. A similar yield stress behaviour was reflected in NMR velocimetry measurements in a Couette geometry, where the solid-to liquid transition could be clearly observed. Under steady-state flow, the fluid state inside the radius at which yield stress was observed, exhibited shear-thinning behaviour with a power law exponent n slowly approaching unity with increasing shear rate. This behaviour has some similarities with a model of Derec et al. in which aging and rejuvenation effects compete. Substantial wall slip was observed both at the inner and at the outer wall, an effect which disappeared as the shear rate was increased. No radial particle migration from the high-shear region at the inner wall was observed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号