首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This work presents a simple design for a mobile single-sided nuclear magnetic resonance (NMR) apparatus with a relatively homogeneous static magnetic field (B0) distribution. In the proposed design, the B0 magnetic field of the apparatus is synthesized using only two permanent magnet blocks, i.e., a cube (main) magnet and a small shim magnet placed above the main magnet. The magnetic flux of the shim magnet partially cancels out that of the main magnet, subsequently creating a smooth B0 profile above the shim magnet where low-resolution NMR experiments are performed. Compared with many previously published designs, this straightforward design simplifies the construction of the apparatus and simultaneously generates a B0 field parallel to the apparatus surface, allowing the use of a simple loop-type radiofrequency (RF) coil. Additionally, an apparatus prototype is constructed according to the proposed design. Weighing only 1.8 kg, the constructed apparatus has a compact structure and can be held in the palm of a hand. The apparatus generates a B0 strength of about 0.0746 T. Within a B0 field deviation of 3 mT, the region with a relatively homogeneous B0 distribution extends to about 11 mm above the shim magnet. The proposed apparatus can detect a clear Hahn echo or Carr-Purcell-Meiboom-Gill (CPMG) echoes of a pencil eraser block or a bottle of oil placed on the apparatus in 5 s with signal averaging using an RF transmitter power of only 19 W; the detection range of the apparatus exceeds 6 mm. The strength of the residual static magnetic field gradient of the apparatus is roughly estimated at 0.58 T/m. Applying different CPMG echo spacings in this residual static gradient leads to various transverse relaxation time (T2) contrasts for liquids with distinct viscosities such as water and oil. Two nondestructive inspection applications of the apparatus, including correlating the concentrations of magnetic nanoparticle solutions with their measured transverse relaxation rates (R2) and monitoring the outgassing from an opened bottle of oxygen-supersaturated water by measuring its longitudinal relaxation rate (R1), are also demonstrated.  相似文献   

2.
Modeling of water diffusion in white matter is useful for revealing microstructure of the brain tissue and hence diagnosis and evaluation of white matter diseases. Researchers have modeled diffusion in white matter using mathematical and mechanical analysis at the cellular level. However, less work has been devoted to evaluate these models using macroscopic real data such as diffusion tensor magnetic resonance imaging (DTMRI) data. DTMRI is a noninvasive tool for evaluating white matter microstructure by measuring random motion of water molecules referred to as diffusion. It reflects directional information of microscopic structures such as fibers. Thus, it is applicable for evaluation and modification of mathematical models of white matter. Nevertheless, a realistic relation between a fiber model and imaging data does not exist. This work opens a promising avenue for relating DTMRI data to microstructural parameters of white matter. First, we propose a strategy for relating DTMRI and fiber model parameters to evaluate mathematical models in light of real data. The proposed strategy is then applied to evaluate and extend an existing model of white matter based on clinically available DTMRI data. Next, the proposed strategy is used to estimate microstructural characteristics of fiber tracts. We illustrate this approach through its application to approximation of myelin sheath thickness and fraction of volume occupied by fibers. Using sufficiently small imaging voxels, the proposed approach is capable of estimating model parameters with desirable precision.  相似文献   

3.
A new method for the ultrafast generation of diffusion-weighted images is reported. The technique combines a quick echo split NMR imaging sequence with the principle of Stejskal and Tanner. It allows to determine the diffusion constant with nearly the same accuracy as the conventional spin-echo technique, requiring only a fraction of the time. The determined values for water doped with 1 g Cu(NO3)2 per liter of H2O and pure acetone were Dwater = (1.95 ± 0.02) × 10−9 m2/s and Dacetone = (4.05 ± 0.02) × 10−9 m2/s at 18.5°C. They are in good agreement both with literature and our own reference measurements using a diffusion-weighted spin-echo sequence. In addition, the temperature dependence of Dwater was measured in the range of 18.5–45.9°C and a good correspondence with reported data was found.  相似文献   

4.
An approach that enables the acquisition of multidimensional NMR spectra within a single scan has been recently proposed and demonstrated. The present paper explores the applicability of such ultrafast acquisition schemes toward the collection of two-dimensional magnetic resonance imaging (2D MRI) data. It is shown that ideas enabling the application of these spatially encoded schemes within a spectroscopic setting, can be extended in a straightforward manner to pure imaging. Furthermore, the reliance of the original scheme on a spatial encoding and subsequent decoding of the evolution frequencies endows imaging applications with a greater simplicity and flexibility than their spectroscopic counterparts. The new methodology also offers the possibility of implementing the single-scan acquisition of 2D MRI images using sinusoidal gradients, without having to resort to subsequent interpolation procedures or non-linear sampling of the data. Theoretical derivations on the operational principles and imaging characteristics of a number of sequences based on these ideas are derived, and experimentally validated with a series of 2D MRI results collected on a variety of model phantom samples.  相似文献   

5.
There has been much recent interest in extending the technique of magnetic resonance imaging (MRI) down to the level of single spins with sub-optical wavelength resolution. However, the signal to noise ratio for images of individual spins is usually low and this necessitates long acquisition times and low temperatures to achieve high resolution. An exception to this is the nitrogen-vacancy (NV) color center in diamond whose spin state can be detected optically at room temperature. Here we apply MRI to magnetically equivalent NV spins and demonstrate fully resolved spectra with resolution well below the optical wavelength of the readout light. In addition, using a microwave version of MRI we achieved a resolution that is 1/270 in size of the coplanar striplines, which define the effective wavelength of the microwaves that were used to excite the transition. This technique can eventually be extended to imaging of large numbers of NVs in a confocal spot and possibly to image nearby dark spins via their mutual magnetic interaction with the NV spin.  相似文献   

6.
In severe perinatal asphyxia, the prognostic value of apparent diffusion coefficient (ADC) measurements is still open to question. We hypothesized that temporal and anatomical changes of brain ADC values occurring early after the hypoxic-ischemic insult could predict the outcome at 36 months. To demonstrate this, mean ADC values were calculated for 16 brain structures in 59 term neonates who underwent an MR examination during the first month of life. Neonates were divided into two groups according to their 36-month outcome: unfavorable (death/severe disability) or favorable outcome. ADC values were plotted against age at scan.In neonates with favorable outcomes (n=32), ADC values were constant over the study period. In babies with unfavorable outcomes (n=27), ADCs exhibited two different patterns. In infratentorial structures, ADCs were constant and normal. In supratentorial areas, ADCs followed a biphasic temporal evolution: ADC values were at their lowest at day 2, showed a rapid increase until Days 5-7, and were thereafter similar to those of neonates with favorable outcomes. Using receiver operating characteristic analysis, during the first 3-5 days of life, all neonates with decreased ADC had an unfavorable outcome.These temporal and anatomical changes of ADC values imply that individual prognosis of asphyxiated neonates can only be predicted by measurement of ADC in supratentorial areas within the first 3-5 days of life.  相似文献   

7.

Purpose

To evaluate the use of the intravoxel incoherent motion (IVIM) technique in half-Fourier single-shot turbo spin-echo (HASTE) diffusion-weighted imaging (DWI), and to compare its accuracy to that of apparent diffusion coefficient (ADC) to predict malignancy in head and neck tumors.

Patients and methods

HASTE DW images of 33 patients with head and neck tumors (10 benign and 23 malignant) were evaluated. Using the IVIM technique, parameters (D, true diffusion coefficient; f, perfusion fraction; D*, pseudodiffusion coefficient) were calculated for each tumor. ADC values were measured over a range of b values from 0 to 1000 s/mm2. IVIM parameters and ADC values in benign and malignant tumors were compared using Student's t test, receiver operating characteristics (ROC) analysis, and multivariate logistic regression modeling.

Results

Mean ADC and D values of malignant tumors were significantly lower than those of benign tumors (P < 0.05). Mean D* values of malignant tumors were significantly higher than those of benign tumors (P < 0.05). There was no significant difference in mean f values between malignant and benign tumors (P > 0.05). The technique of combining D and D* was the best for predicting malignancy; accuracy for this model was higher than that for ADC.

Conclusions

The IVIM technique may be applied in HASTE DWI as a diagnostic tool to predict malignancy in head and neck masses. The use of D and D* in combination increases the diagnostic accuracy in comparison with ADC.  相似文献   

8.
More than a dozen Nuclear Magnetic Resonance (NMR) imaging methods have been described using different radio-frequency pulse sequences, magnetic field gradient variations, and data processing. In order to have a theoretical understanding in the most general case, we have conceived a computer program for the simulation of NMR imaging techniques. The algorithm uses the solution of the Bloch equations at each point of a simulated object. The direction of every elementary magnetic moment is computed at each instant, and stored in an array giving the global signal to be processed, whatever the pulse and gradient sequence. To test the validity of this program, we have simulated some well-known experimental results. Some applications are presented which contribute to the understanding of image distortions and to techniques such as selective radio-frequency pulse or oscillating gradients. This program can be used to unravel physical and technological causes of image distortions, to have a "microscopic" look at any parameter of an experiment, and to study the contrast given by various NMR imaging techniques as a function of the three NMR parameters, i.e., the hydrogen nuclei density rho and the relaxation times T1 and T2.  相似文献   

9.
Images of the rat head reflecting glucose utilization were obtained using 2-fluoro-2-deoxy-D-glucose (2-FDG) and 19F nuclear magnetic resonance (NMR) imaging. Spatial heterogeneity of glucose utilization in the rat head was clearly demonstrated showing significantly higher glucose utilization in the brain as compared to the surrounding tissues. Although the potential adverse effects of the high doses of 2-FDG (400 mg/kg) needed to perform the study preclude immediate application of this technique to clinical quantitative glucose utilization studies, the present study shows potential for future development of glucose utilization imaging by NMR.  相似文献   

10.
11.
Diffusion weighted magnetic resonance imaging (DWI) has been mostly acquired using single-shot echo-planar imaging (ss EPI) to minimize motion induced artifacts. The spatial resolution, however, is inherently limited in ss EPI especially for abdominal imaging, even with the advances in parallel imaging. A novel method of reduced Field of View ss EPI (rFOV ss EPI) has achieved high resolution DWI in human carotid artery, spinal cord with reduced blurring and higher spatial resolution than conventional ss EPI, but it has not been used to pancreas imaging. In the work, comparisons between the full FOV ss-DW EPI and rFOV ss-DW EPI in image qualities and ADC values of pancreatic tumors and normal pancreatic tissues were performed to demonstrate the feasibility of pancreatic high resolution rFOV DWI. There were no significant differences in the mean ADC values between full FOV DWI and rFOV DWI for the 17 subjects using b = 600 s/mm2 (P = 0.962). However, subjective scores of image quality was significantly higher at rFOV ss DWI (P = 0.008 and 0.000 for b-value = 0 s/mm2 and 600 s/mm2 respectively). The spatial resolution of DWI for pancreas was increased by a factor of over 2.0 (from almost 3.0 mm/pixel to 1.25 mm/pixel) using rFOV ss EPI technique. Reduced FOV ss EPI can provide good DW images and is promising to benefit applications for pancreatic diseases.  相似文献   

12.
The purpose of this study was to determine whether proton magnetic resonance spectroscopy (PMRS) and diffusion tensor imaging (DTI) indices, fractional anisotropy (FA) and mean diffusivity (MD) can be used to distinguish brain abscess from cystic brain tumors, which are difficult to distinguish by conventional magnetic resonance imaging (MRI). Fifty-three patients with intracranial cystic mass lesions and 10 normal controls were studied. Conventional MRI, PMRS and DTI of all the patients were performed on a 1.5-T GE scanner. Forty patients were with brain abscess and 13 with cystic tumors. Cytosolic amino acids (AAs) were present in 32 of 40 brain abscess patients. Out of 13 patients with cystic tumors, lactate and choline were seen in 3 and only lactate was present in 10 patients on PMRS. All 40 cases of abscess had high FA, while all 13 cases of tumor cysts had high MD values. We conclude that FA measurements are more sensitive in predicting the abscess, while PMRS and MD are more specific in differentiating abscess from cystic tumors. We suggest that PMRS should be combined with DTI rather than with diffusion-weighted imaging as FA can be used as an additional parameter for separation of abscess from other cystic intracranial mass lesions.  相似文献   

13.
The 1H and 2H spin-lattice relaxation times in the monohydride phase of the V-H-D and Ti0.1V0.9-H-D systems have been re-analyzed by Bloembergen-Purcell-Pound (BPP) equations with a log-normal distribution of correlation times, and the obtained parameters have been compared with those of the Ti0.33V0.67-H-D system. The mean activation energy and the magnitude of the distribution of H and D diffusions are discussed in relation to the metal compositions, the hydrogen site, the crystal structure and the [H]/[D] ratios.  相似文献   

14.
NMR velocimetry has been used to observe the steady-shear rheological behaviour of a concentrated suspension of hard-sphere like 370 nm diameter PMMA core-shell latex particles at the volume fraction Φ = 0.46, the liquid core of the spheres rendering possible NMR observation of the particles themselves. Rheological measurements in a cone-and-plate geometry indicate that when aged (i.e. left at rest for two weeks), the material exhibits yield stress behaviour at very low shear rates. For shear rates greater than 1 s - 1 a transition to liquid-like behaviour was observed, leading to a rejuvenated fluid state which exhibits shear-thinning behaviour over a wide range of shear rates. A similar yield stress behaviour was reflected in NMR velocimetry measurements in a Couette geometry, where the solid-to liquid transition could be clearly observed. Under steady-state flow, the fluid state inside the radius at which yield stress was observed, exhibited shear-thinning behaviour with a power law exponent n slowly approaching unity with increasing shear rate. This behaviour has some similarities with a model of Derec et al. in which aging and rejuvenation effects compete. Substantial wall slip was observed both at the inner and at the outer wall, an effect which disappeared as the shear rate was increased. No radial particle migration from the high-shear region at the inner wall was observed.  相似文献   

15.
NMR of laser-polarized xenon is used to probe the dissolution behaviour of the noble gas in different liquids. The dissolution and self-relaxation rates are extracted via a macroscopic model, and comparison of the decay rate of the xenon magnetization in deuterated and non-deuterated solvent pairs allows the determination of the pure dipole-dipole contribution to relaxation. A transient convective effect, tentatively assigned to the xenon concentration gradient, is observed and characterized by diffusion encoding MRI experiments. The flow of xenon penetrates inside the solvent near the walls of the NMR tube, the longitudinal images showing a “” shape, the transverse ones a “O” shape. This convection effect has implications for delivery conditions of laser-polarized xenon in continuous flow experiments and magnetic resonance imaging. Received 29 April 2002 / Received in final form 26 July 2002 Published online 22 October 2002 RID="a" ID="a"e-mail: hdesvaux@cea.fr RID="b" ID="b"URA CNRS/CEA 331  相似文献   

16.
Motor imagery is an experimental paradigm implemented in cognitive neuroscience and cognitive psychology. To investigate the asymmetry of the strength of cortical functional activity due to different single-hand motor imageries, functional magnetic resonance imaging (fMRI) data from right handed normal subjects were recorded and analyzed during both left-hand and right-hand motor imagery processes. Then the average power of blood oxygenation level-dependent (BOLD) signals in temporal domain was calculated using the developed tool that combines Welch power spectrum and the integral of power spectrum approach of BOLD signal changes during motor imagery. Power change analysis results indicated that cortical activity exhibited a stronger power in the precentral gyrus and medial frontal gyrus with left-hand motor imagery tasks compared with that from right-hand motor imagery tasks. These observations suggest that right handed normal subjects mobilize more cortical nerve cells for left-hand motor imagery. Our findings also suggest that the approach based on power differences of BOLD signals is a suitable quantitative analysis tool for quantification of asymmetry of brain activity intensity during motor imagery tasks.  相似文献   

17.

Purpose

To optimize the navigator-gating technique for the acquisition of high-quality three-dimensional spoiled gradient-recalled echo (3D SPGR) images of the liver during free breathing.

Materials and methods

Ten healthy volunteers underwent 3D SPGR magnetic resonance imaging of the liver using a conventional navigator-gated 3D SPGR (cNAV-3D-SPGR) sequence or an enhanced navigator-gated 3D SPGR (eNAV-3D-SPGR) sequence. No exogenous contrast agent was used. A 20-ms wait period was inserted between the 3D SPGR acquisition component and navigator component of the eNAV-3D-SPGR sequence to allow T1 recovery. Visual evaluation and calculation of the signal-to-noise ratio were performed to compare image quality between the imaging techniques.

Result

The eNAV-3D-SPGR sequence provided better noise properties than the cNAV-3D-SPGR sequence visually and quantitatively. Navigator gating with an acceptance window of 2 mm effectively inhibited respiratory motion artifacts. The widening of the window to 6 mm shortened the acquisition time but increased motion artifacts, resulting in degradation of overall image quality. Neither slice tracking nor incorporation of short breath holding successfully compensated for the widening of the window.

Conclusion

The eNAV-3D-SPGR sequence with an acceptance window of 2 mm provides high-quality 3D SPGR images of the liver.  相似文献   

18.
Quantification of the living human visual system using MRI methods has been challenging, but several applications demand a reliable and time-efficient data acquisition protocol. In this study, we demonstrate the utility of high-spatial-resolution diffusion tensor fiber tractography (DTT) in reconstructing and quantifying the human visual pathways. Five healthy males, age range 24–37 years, were studied after approval of the institutional review board (IRB) at The University of Texas Health Science Center at Houston. We acquired diffusion tensor imaging (DTI) data with 1-mm slice thickness on a 3.0-Tesla clinical MRI scanner and analyzed the data using DTT with the fiber assignment by continuous tractography (FACT) algorithm. By utilizing the high-spatial-resolution DTI protocol with FACT algorithm, we were able to reconstruct and quantify bilateral optic pathways including the optic chiasm, optic tract, optic radiations free of contamination from neighboring white matter tracts.  相似文献   

19.
The 1H and 23Na spin–lattice and spin–spin relaxation times of NaH3(SeO3)2 single crystals grown using the slow-evaporation method were measured as functions of temperature and frequency in the ferroelectric and paraelectric phases. The changes in the symmetry of the (SeO3)2− dimers as a result of the ferroelectric–paraelectric phase transition are associated with large changes in the spin–lattice and spin–spin relaxation times, and in the number of resonance lines. The large changes in the relaxation times at 195 K indicate that the H and Na ions are significantly affected by this transition. The change in the number of resonance lines for the 1H and 23Na nuclei means that the orientations of the (SeO3)2− dimers and the environments of the Na ions change at TC. Therefore, the orientations of the (SeO3)2− dimers and the environments of the Na ions play important roles in the phase transitions. In conclusion, the ferroelectric–paraelectric phase transition of NaH3(SeO3)2 is accompanied by changes in hydrogen-bond structure and distortions of the (SeO3)2− and Na+ ion lattices, which form a slightly distorted octahedron.  相似文献   

20.
The first step in quantitative pharmacokinetic modeling is to determine the arterial input function (AIF) by deriving the contrast medium (CM) concentration from an appropriate imaging sequence by monitoring changes in either the amplitude or the phase signal of an accommodative artery. The bolus passage is best detected on T2- or T2*-weighted images, while extravasation is best assessed on T1-weighted images. Here, an imaging sequence is used that employs a parallel acquisition technique for the interleaved acquisition of an inversion-prepared T1-weighted image and a T1/T2*-mixed-weighted image for determination of the AIF.

The sequence was applied in six patients with prostate cancer. A method is presented for quantifying the AIF derived from the signal intensity-time courses of both the T1/T2*-mixed-weighted and the T1-weighted image. Furthermore, in some patients the signal intensity-time course of the T1-weighted image exhibits flow-induced signal modulations. To reduce the effect of this flow-related signal enhancement the corresponding phase information was used.

The sequence presented here has the potential to improve the quantification of the AIF at all time points and pharmacokinetic modeling of the CM dynamics of the prostate.  相似文献   