首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work describes a novel approach for monitoring analyte diffusion in solution that is based on electrospray ionization mass spectrometry (ESI-MS). A mass spectrometer at the end of a laminar flow tube is used to measure the Taylor dispersion of an initially sharp boundary between two solutions of different analyte concentration. This boundary is dispersed by the laminar flow profile in the tube. However, this effect is diminished by analyte diffusion that continuously changes the radial position, and hence the flow velocity of individual analyte molecules. The steepness of the resulting dispersion profile therefore increases with increasing diffusion coefficient of the analyte. A theoretical framework is developed to adapt the equations governing the dispersion process to the case of mass spectrometric detection. This novel technique is applied to determine the diffusion coefficients of choline and cytochrome c. The measured diffusion coefficients, (11.9 +/- 1.0) x 10(-10) m(2) s(-1) and (1.35 +/- 0.08) x 10(-10) m(2) s(-1), respectively, are in agreement with the results of control experiments where the Taylor dispersion of these two analytes was monitored optically. Due to the inherent selectivity and sensitivity of ESI-MS, it appears that the approach described in this work could become a valuable alternative to existing methods for studying diffusion processes, especially for experiments on multicomponent systems.  相似文献   

2.
Negative quasimolecular ions of aromatic carboxylic acid amides have been observed unexpectedly under electrospray ionization conditions. Hypothetically, deprotonation of either carboxamide or carboximidic acid tautomers can produce anions with equivalent resonance structures, the stability of which is affected by conjugated aromatic substituents. In this study, a series of meta and para substituted benzamides were analyzed using electrospray ionization mass spectrometry in aqueous methanolic solutions. The degree of ionization was found to be pH dependent and was enhanced by electron-withdrawing substituents and suppressed by electron-donating groups. The observed effect on apparent acidity can be accounted for by resonance stabilization.  相似文献   

3.
4.
This work describes the synchronized dual-polarity (DP) electrospray ionization (ESI) method and demonstrates the first DP ESI mass spectra obtained using two mass spectrometers. Stable double Taylor cones were produced by applying two counter electric voltages with opposite polarities to one electrosprayer. The development of double Taylor cones required higher extraction voltages than conventional ESI, but DP ESI worked effectively at liquid flow rate range three times wider than conventional ESI. Using pure methanol, the emission currents of the two cones were neutralized and no current was drawn from the sprayer. Synchronized DP mass spectra were obtained using electrospray calibrants dissolved in methanol solution of low water content. For bovine insulin with conventional electrospray solution, the gas-assisted electrospray delivered satisfactory sensitivity and stability for routine mass analyses.  相似文献   

5.
Editorial Comment Last month we presented, as a Special Feature, a set of five articles that constituted a Commentary on the fundamentals and mechanism of electrospray ionization (ESI). These articles produced some lively discussion among the authors on the role of electrochemistry in ESI. Six authors participated in a detailed exchange of views on this topic, the final results of which constitute this month's Special Feature. We particularly hope that younger scientists will find value in this month's Special Feature, not only for the science that it teaches but also what it reveals about the processes by which scientific conclusions are drawn. To a degree, the contributions part the curtains on these processes and show science in action. We sincerely thank the contributors to this discussion. The give and take of intellectual debate is not always easy, and to a remarkable extent this set of authors has maintained good humor and friendships, even when disagreeing strongly on substance. Graham Cooks and Richard Caprioli Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

6.
7.
Using electrospray ionization (tandem) mass spectrometry (ESI-MS(/MS)) spectrometric experiments, the Sandmeyer reaction was monitored on-line, and key intermediates were intercepted and characterized for the first time. The mechanistic information provided by on-line ESI-MS(/MS) is in accordance with Sandmeyer's proposal, and was made possible by coupling a microreactor on-line to the ESI ion source, which allowed reactions to be screened from 0.7-2.0 s, identifying and characterizing all intermediates that were formed and consumed during the reaction.  相似文献   

8.
We have designed and constructed an atmospheric pressure laser desorption/chemical ionization (AP-LD/CI) source that utilizes a laser pulse to desorb intact neutral molecules, followed by chemical ionization via reagent ions produced by a corona discharge. This source employs a heated capillary atmospheric pressure inlet coupled to a quadrupole ion trap mass spectrometer and allows sampling under normal ambient air conditions. Preliminary results demonstrate that this technique provides approximately 150-fold increase in analyte ions compared to the ion population generated by atmospheric pressure infrared matrix-assisted laser desorption/ionization (AP-IR-MALDI).  相似文献   

9.
10.
11.
12.
13.
Desorption electrospray ionization mass spectrometry (DESI-MS) has been used for monitoring solid-state organic reaction in ambient air, specifically the Baeyer-Villiger (BV) type reaction involving the oxidation of ketones (benzophenone or deoxybenzoin) by m-chloroperbenzoic acid (m-CPBA) in solid-state. The DESI mass spectra obtained at regular intervals during the BV reaction processes are featured, with the amount of ester products increasing as those of ketone reactants decrease. Quantitative analyses of relative intensities of the product, made to quantify the reaction degree of typical solid-state organic reaction (SSOR), show a precision with RSDs of around 5% to 12%, though the RSDs for direct analysis of intensities of the reactant or the product in the solid-state are obviously larger. The kinetics of the Baeyer-Villiger type reactions in solid-state are shown to be dramatically different, in reaction rate, kinetic curve, as well as concentration dependence, from those of the same reactions taking place in solution.  相似文献   

14.
A one-step phosphoryl derivatization method has been used in a peptide sequencing procedure for electrospray ionization tandem mass spectrometry (ESI-MS/MS). The sodiated derivatized peptides exhibit very simple dissociation patterns, in which two kinds of fragment ions, [b(n) + OH + Na]+ and [a(n) + Na]+, are formed. Since the amino acid residues are lost sequentially from the C-terminus, peptide sequences can be identified easily. The fragmentation efficiency of peptides increased as a result of the phosphorylation, and also provided peaks of useful intensity at lower m/z. A peptide with lysine at the C-terminus was derivatized and analyzed by ESI-MS/MS. Similar mass spectra, from which the sequence could be read out, were obtained. This is a novel derivatization method yielding neutral derivatives that should be suitable for peptide sequencing by LC/ESI-MS/MS.  相似文献   

15.
Chemical standards for positive ion mode electrospray ionization ion mobility spectrometry/mass spectrometry (ESI(+)-IMS/MS) are suggested. The low clustering tendency of tetraalkylammonium halides makes them ideal chemical standards for ESI(+)-IMS/MS. A homologous series of these compounds forms a useful external standard for instrument testing and resolution calibration of an IMS instrument. Selected homologues or a mixture of tetraalkylammonium halides can be used as mobility standards in the analytical runs. Absolute and relative reduced mobilities were calculated for C2--C8, C10 and C12 tetraalkylammonium halides. Absolute reduced mobilities in nitrogen were 1.88, 1.56, 1.33, 1.15, 1.02, 0.92, 0.84, 0.73, and 0.67 cm2 V(-1) s(-1), for C2--C8, C10 and C12 tetraalkylammonium halides, respectively. Relative reduced mobilities (relative to 2,6-di-tert-butylpyridine) for the same compounds were 1.20, 1.00, 0.855, 0.743, 0.658, 0.59, 0.54, 0.47, and 0.43, respectively.  相似文献   

16.
17.
On-line monitoring of Stille reactions was performed via direct infusion electrospray ionization mass spectrometry (ESI-MS) and its tandem version (ESI-MS/MS). When operated in the positive ion mode, ESI(+)-MS was able to transfer, directly from solution to the gas phase, the species involved in all main steps of a Stille reaction, that is, the catalytically active palladium species Pd(PPh3)2, in its molecular ion form as well as the key cationic Pd(II) intermediates, including cyclic IPd-(CH2CH)Sn species. When searching for anionic species, ESI(-)-MS monitoring showed I- as the only anion detectable in the reaction medium. A detailed catalytic cycle for a Stille reaction was elaborated in which reaction intermediates and the previously elusive catalytically active Pd(0) species are shown in association with the respective ionic species intercepted by ESI-MS and further characterized by ESI-MS/MS.  相似文献   

18.
Supplemental infrared (IR) activation was applied to reduce background chemical noise and increase analyte ion signal in a linear ion trap mass spectrometer. Peptides, proteins, and small molecules were all introduced by electrospray ionization, and when regions of chemical noise were isolated and subjected to IR irradiation, protonated analyte molecules were observed in the product ion mass spectra. By isolating the entire mass range (e.g., m/z 400–2000) and then irradiating all ions in the trap, supplemental IR activation increased the signal of singly protonated peptides by almost 70% and by 40%–55% for the lower charge states of cytochrome c. This increase in analyte ion signal was less dramatic for the higher charge states of peptides and proteins. The chemical noise present in the mass spectra is attributed to incomplete desolvation of the electrospray, as the abundance of the protonated peptides observed upon supplemental IR activation of the chemical noise decreased with higher inlet capillary temperatures. Collision activation was not as effective for desolvating the ions present in the chemical noise.  相似文献   

19.
Rezenom YH  Dong J  Murray KK 《The Analyst》2008,133(2):226-232
We have used an infrared laser for desorption of material and ionization by interaction with electrosprayed solvent. Infrared laser-assisted desorption electrospray ionization (IR LADESI) mass spectrometry was used for the direct analysis of water-containing samples under ambient conditions. An ion trap mass spectrometer was modified to include a pulsed Er:YAG laser at 2.94 microm wavelength coupled into a germanium oxide optical fiber for desorption at atmospheric pressure and a nanoelectrospray source for ionization. Analytes in aqueous solution were placed on a stainless steel target and irradiated with the pulsed IR laser. Material desorbed and ablated from the target was ionized by a continuous stream of charged droplets from the electrosprayed solvent. Peptide and protein samples analyzed using this method yield mass spectra similar to those obtained by conventional electrospray. Blood and urine were analyzed without sample pretreatment to demonstrate the capability of IR LADESI for direct analysis of biological fluids. Pharmaceutical products were also directly analyzed. Finally, the role of water as a matrix in the IR LADESI process is discussed.  相似文献   

20.
A micelle solution of decyltrimethylammonium bromide (DTAB) was analyzed by electrospray ionization mass spectrometry. Finding an appropriate range of a capillary-skimmer potential was a prerequisite for obtaining a satisfactory spectrum. The mean molecular weight of DTAB aggregates, 10,500, was deduced from a series of mass spectra acquired at different capillary-skimmer potentials. The value was comparable with the micelle weight, previously determined by the light-scattering method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号