共查询到20条相似文献,搜索用时 0 毫秒
1.
Electrospray ionization mass spectrometry was applied to the study of the amines IQ, Trp-P-1, Trp-P-2, PhIP and AC and the co-mutagens harman and norharman. The results obtained on a triple quadrupole mass spectrometer equipped with a pneumatically assisted electrospray source are reported. The chromatographic conditions were optimized with a reversed-phase column (1 mm I.D.) using acetonitrile-5 mM ammonium acetate (pH 6.7) (50:50) as the mobile phase at a flow-rate of 50 μl min−1. Different parameters influencing the mass spectra were investigated. For these compounds [M + H]+ in the positive-ion mode and also some fragments produced through collisionally activated decomposition in the interface were observed. Detection limits of 5.4–44 pg were obtained for standard solutions of these amines. Analysis of a meat extract was performed by HPLC-MS using single-ion monitoring after a solid-phase extraction clean-up. 相似文献
2.
Heterocyclic amines are a group of potent mutagenic compounds which are generated when muscle meat is cooked. Since they are possible human carcinogens, these mutagens have received considerable attention in recent years, and several analytical techniques have been developed for their quantification. Although the purification step is one of the most important, there are a great number of variables influencing the recovery of the amines, especially when real samples are analysed. In this work we studied the influence of sample spiking mode on the recoveries. Furthermore, on the basis of a previously developed clean-up method, the effect of changing commercial source and structure of the sorbents used in two solid-phase extraction steps was examined. This purification method was applied to the quantification of the heterocyclic aromatic amines present in a lyophilised meat extract by means of liquid chromatography–mass spectrometry. 相似文献
3.
建立了液相色谱-离子阱-飞行时间串联质谱法(LC-IT-TOF MS)同时测定葡萄酒中14种杂环胺(HAAs)残留量的分析方法。样品于乙酸乙酯碱性条件下提取,内标法定量,Phenomenex Kinetex C18 100A色谱柱(100 mm×2.1 mm, 2.6 μm)分离,以乙腈和30 mmol/L甲酸铵为流动相进行梯度洗脱。实验结果表明,2-氨基-3,7,8-三甲基咪唑[4,5-f]喹喔啉在1~500 μg/L、2-氨基-3,8-二甲基咪唑[4,5-f]喹喔啉在10~500 μg/L、其他12种杂环胺在5~500 μg/L质量浓度范围内线性良好,相关系数均不小于0.9945,检出限(以信噪比为3计) 0.33~1.77 μg/L。14种杂环胺在加标水平为10、50、100 μg/L时的回收率分别为71.6%~96.4%、72.9%~101.9%、74.5%~103.3%,相对标准偏差(RSD, n=6)分别为2.9%~7.9%、1.7%~5.3%、1.8%~4.8%。结果显示该方法线性范围宽,精密度和准确度较高,分析时间短,净化效果好,可满足葡萄酒中多种杂环胺残留同时检测的要求。 相似文献
4.
A method was developed for the quantitative determination of alachlor, benalaxyl, clomazone, diflubenzuron, dimethomorph, diphenamid, ethofumesate, metalaxyl, methoprene, metobromuron and piperonyl butoxide on tobacco. The pesticides were extracted with water and methanol from five different types of tobacco. The extracts were purified by partition on an extraction cartridge containing diatomaceous earth. The purified extracts were analysed by reversed-phase high-performance liquid chromatography connected to an atmospheric pressure ionisation–electrospray-triple quadrupole mass spectrometer operating in the positive ion mode. Two different transitions and their relative intensities were monitored for unambiguous identification. All pesticides presented overall recovery rates between 35% and 110%. The trueness is near 100% and the interday precision is below 15%. The limits of quantifications are equal or below the guidance residue levels proposed by the Agrochemical Advisory Committee of CORESTA, an association of organisations having scientific research relative to tobacco. 相似文献
5.
The fragmentation of heterocyclic amines (HAs) in an ion trap was studied by means of the infusion of methanolic solutions containing the compounds under assay, and using an atmospheric pressure chemical ionization (APCI) as ion source. The MS(n) spectra obtained for compounds included in the same family, either aminoimidazoazaarenes (AIAs) or carbolines, were compared in order to propose fragmentation pathways for each HA. Moreover, labelled AIAs were used to establish the mechanisms. The protonated molecule was always obtained, but subsequent fragmentation was different for both families. In the case of AIAs, major product ions came from the fragmentation of the aminoimidazole moiety, thus the base peak in MS(2) corresponded to the loss of the methyl group, and losses of C(2)NH(3) and CN(2)H(2) were also observed. Further fragmentation occurred in the heterocyclic rings, mainly with losses of HCN and CH(3)CN. For carbolines, the most important product ions came from the loss of ammonia, except for harman and norharman, the loss of a methyl group for methylated carbolines or the loss of diverse fragments from the heterocyclic rings. In some cases, ion-molecule reactions into the ion trap were observed. For instance, for AalphaC or MeAalphaC one ion originating from these reactions corresponded to the base peak. 相似文献
6.
建立了检测油脂及油炸食品中7种杂环胺类物质的超高效液相色谱-三重四极杆质谱(UPLC-MS/MS)的检测方法。以含1%(体积分数)氨水的乙腈溶液为提取液,采用乙腈饱和的正己烷脱脂,以PCX固相萃取柱为净化柱,10 mmol/L甲酸铵溶液(pH 6.8)和乙腈为流动相,采用Waters ACQUITY UPLC BEH C18反相色谱柱(50 mm×2.1 mm, 1.7μm)梯度洗脱,流速为0.3 mL/min,在正离子扫描、多反应监测模式下测定,内标法定量。结果表明,杂环胺类物质在各自范围内,线性关系良好,相关系数大于0.999;在3个加标水平下,杂环胺类物质在油脂和油炸食品中的平均回收率为64.31%~113.8%,相对标准偏差为0.18%~9.26%,检出限(S/N=3)和定量限(S/N=10)分别为0.01~0.14 ng/g和0.09~0.38 ng/g。该方法具有灵敏、准确等优点,适用于油脂和油炸食品中杂环胺的确证检测。 相似文献
7.
Summary Improved HPLC and ESMS conditions have been established, allowing the separation and analysis of oligodesoxyribonucleotides by coupled HPLC-ESMS. 相似文献
8.
Zanolari B Wolfender JL Guilet D Marston A Queiroz EF Paulo MQ Hostettmann K 《Journal of chromatography. A》2003,1020(1):75-89
The bark of catuaba (Erythroxylum vacciniifolium Martius, Erythroxylaceae), a tree native to the northern part of Brazil, was investigated for its alkaloid content. With the aim of obtaining preliminary structure information on-line, the alkaloid extract was analysed by high-performance liquid chromatography coupled to diode array UV detection, to mass spectrometry and to nuclear magnetic resonance. Interpretation of on-line spectroscopic data obtained from this extract led to structural elucidation of six new alkaloids and partial identification of 18 potentially original alkaloids bearing the same tropane skeleton esterified in positions 3 and 6 by 1-methyl-1H-pyrrol-2-carboxylic acid and/or 4-hydroxy-3,5-dimethoxybenzoic acid. 相似文献
9.
The reports of this series tabulate a number of features of analytical instruments that should be considered when making comparison
between various systems. Scoring these features in a rational manner allows a scientific comparison to be made between instruments
as an aid to selection. This is the XXIInd report of the series and deals with instrumentation for liquid chromatography/mass
spectrometry. 相似文献
10.
Markus Haapala Ville Saarela Jaroslav Pól Kai Kolari Sami Franssila Risto Kostiainen 《Analytica chimica acta》2010,662(2):163-169
A new integrated microchip for liquid chromatography-mass spectrometry (LC-MS) is presented. The chip is made from bonded silicon and glass wafers with structures for a packed LC column channel, a micropillar frit, a channel for optional optical detection, and a heated vaporizer section etched in silicon and platinum heater elements on the glass cover. LC eluent is vaporized and mixed with nebulizer gas in the vaporizer section and the vapor is sprayed out from the chip. Nonpolar and polar analytes can be efficiently ionized in the gas phase by atmospheric pressure photoionization (APPI) as demonstrated with polycyclic aromatic hydrocarbons (PAHs) and selective androgen receptor modulators (SARMs). This is not achievable with present LC-MS chips, since they are based on electrospray ionization, which is not able to ionize nonpolar compounds efficiently. The preliminary quantitative performance of the new chip was evaluated in terms of limit of detection (down to 5 ng mL−1), linearity (r > 0.999), and repeatability of signal response (RSD = 2.6-4.0%) and retention time (RSD = 0.3-0.5%) using APPI for ionization and PAHs as standard compounds. Determination of fluorescent compounds is demonstrated by using laser-induced fluorescence (LIF) for detection in the optical detection channel before the vaporizer section. 相似文献
11.
Natividad García-Villar Santiago Hernández-CassouJavier Saurina 《Journal of chromatography. A》2009,1216(36):6387-6393
A new HPLC method for determining biogenic amines in wines is developed. This method is based on pre-column amine derivatization, further separation of derivatives and on-line hyphenation of HPLC to atmospheric pressure chemical ionization mass spectrometry (APCI-MS). Biogenic amines have been derivatized with 1,2-naphthoquinone-4-sulfonate at 65 °C and pH 9.2 for 5 min. The separation of derivatives has been accomplished in a C18 analytical column using an elution gradient based on increasing the percentage of methanol. Derivatives have been ionized in positive mode and detected by selected ion monitoring. The operating conditions of the APCI-MS system (voltages, temperatures and gases) have been thoroughly optimized to obtain the maximum sensitivity for all analytes. In the selected conditions, APCI-MS spectra display little fragmentation and good signal-to-noise ratio. Depending on the amine characteristics, the main spectral peaks are due to mono- and di-derivative products. Figures of merit of the method have been established under the selected conditions using red wine samples. Recoveries ranging from 94% to 106% have been obtained which prove excellent accuracy of the method in the determination of histamine, putrescine, cadaverine, tryptamine, phenylethylamine, tyramine and serotonin in red wines. The proposed method has been applied to the analysis of commercial wines from different Spanish regions. 相似文献
12.
Yuan Zhang Wen‐jie Wu Wei‐e Zhou Zhi‐qin Ren Xue‐song Feng Feng Zhang 《Journal of separation science》2020,43(7):1372-1381
A novel, simple, and sensitive method has been developed for simultaneous determination of 14 heterocyclic aromatic amines in meat product using solid‐phase extraction combined with ultrahigh‐performance supercritical fluid chromatography coupled to tandem quadrupole mass spectrometry. The analytes could be separated within 7 min and identified using their retention times and mass. The developed method was validated based on the linearity, limits of quantification, precision, and accuracy. The recovery ranged from 52.3 to 97.5% with an acceptable standard deviation, which is not higher than 6%. The limits of quantitation ranged from 0.03 to 0.17 µg/kg. The selectivity and sensitivity were satisfactory in multiple reaction monitoring mode. The method was applied to commercial meat products, and the results demonstrated that the novel method has potential for the analysis of the targets in food matrices. This is the first work reporting the simultaneous quantification of 14 heterocyclic aromatic amines by means of ultrahigh‐performance supercritical fluid chromatography coupled to tandem quadrupole mass spectrometry. 相似文献
13.
14.
Zhao C Wu Z Xue G Wang J Zhao Y Xu Z Lin D Herbert G Chang Y Cai K Xu G 《Journal of chromatography. A》2011,1218(23):3669-3674
Nanoflow liquid chromatography/mass spectrometry (nano-LC/MS) has attracted increasing interest in virtue of high sensitivity, low sample consumption, and minimal matrix effect. In this work a HPLC-Chip/quadrupole time-of-flight (Q-TOF) MS device with a new ultra-high capacity small molecule chip (UHC-Chip) which features a 500 nL enrichment column and a 150 mm × 75 μm analytical column, was evaluated with a drug mixture covering a wide range of polarities. Excellent chromatographic precision with 0.1-0.5% RSD for retention time and 1.7-9.0% RSD for peak area, low limit of detection, good chip-to-chip reproducibility and linearity were obtained by using this UHC-Chip. Compared with the standard HPLC-Chip with 40 nL trapping column, the UHC-Chip showed higher enrichment capability and hence gave a higher response in signal detection. Additionally, 4-30 times increase in sensitivity was obtained compared with conventional LC/MS, which indicated that UHC-Chip/MS was a valuable tool for the quantitative analysis of low level impurities and degradation products in pharmaceuticals. Moreover, satisfactory results obtained from trace drug analysis of serum samples further proved its practicality and potential for use in drug testing and development. 相似文献
15.
We report an enabling mass spectrometric method for the analysis of lipid metabolites in order to define better the lipid metabolome in terms of chemical diversity and generate fragment ion spectra of these metabolites as a potential resource for unknown metabolite identification. This work focuses on the analysis of one important class of lipid metabolites, the acylcarnitines. Current analytical methods have only detected and identified a limited number of these metabolites. The method described herein provides the most comprehensive acylcarnitine profile in urine of healthy individuals up to date. It involves an optimized solid phase extraction technique for selective analyte extraction using cartridges containing both lipophilic and cation-exchange properties. The captured analytes are then subjected to ultra-high performance liquid chromatography (UPLC) separation, followed by tandem mass spectrometry (MS/MS) analysis using information-dependent acquisitions and selected reaction monitoring (SRM). The urine of six healthy individuals was analyzed using this method. A total of 355 acylcarnitines were detected; only 43 of them have been previously reported in the urine of healthy individuals. Detection of this large number of acylcarnitines illustrates the great diversity of the lipid metabolome as well as the usefulness of the method for profiling acylcarnitines. Furthermore, the MS/MS spectra of the 355 acylcarnitines will be uploaded to a public human metabolome database as a mass spectrometric resource for unknown metabolite identification. 相似文献
16.
Bomke S Seiwert B Dudek L Effkemann S Karst U 《Analytical and bioanalytical chemistry》2009,393(1):247-256
A liquid chromatography (LC)/mass spectrometry method was developed for the determination of selected biogenic amines in various
fish and other food samples. It is based on a precolumn derivatization of the amines with succinimidylferrocenyl propionate
under formation of the respective amides and their reversed-phase liquid-chromatographic separation with subsequent electrospray
ionization mass-spectrometric detection. Deuterated putescine, cadaverine, and histamine are added prior to the derivatization
as internal standards that are coeluted, thus allowing excellent reproducibility of the analysis to be achieved. Depending
on the analyte, the limits of detection were between 1.2 and 19.0 mg/kg, covering between 2 and 3 decades of linearity. The
limit of detection and the linear range for histamine are suitable for the surveillance of the only defined European threshold
for biogenic amines in fish samples. Compared with the established ortho-phthalaldehyde (OPA)/LC/fluorescence method, the
newly developed method allows an unambiguous identification of the biogenic amines by their mass spectra in addition to only
retention times, a fivefold acceleration of the separation, and independency from the sample matrix owing to the isotope-labeled
internal standards. Various fish, calamari, and salami samples were successfully analyzed with the new method and validated
with an independent OPA/LC/fluorescence method. 相似文献
17.
建立了测定植物中痕量脱落酸 (ABA) 的液相色谱-电喷雾串联质谱联用分析方法. 植物提取液先采用固相萃取 (SPE) 富集脱落酸并消除基体干扰, 然后以C18柱为固定相, V(甲醇)∶V(2 g/L甲酸水溶液)=50∶50为流动相分离脱落酸. 电喷雾(ESI)串联质谱采用负离子模式. 选择反应监测 (SRM) 模式用于脱落酸定量, 选择的离子对是263→153, 219. 脱落酸的线性范围为0.005~10 μg/mL, 检测限 (S/N=3) 为0.003 μg/mL, 加标0.02 μg和0.05 μg的回收率分别为98.3% 和103.5%. 该方法用于冬青芽中脱落酸的分析, 结果表明所建立的SPE-LC-MS/MS方法对于分析植物中的痕量脱落酸是有效的. 相似文献
18.
The efficiencies of three derivatisation reagents that react with either the amine (9-fluorenylmethyl chloroformate (FMOC)) or the carboxylic acid group (butanol) of amino acid or with both types of functional groups (propyl chloroformate) were compared in the analysis of amino acids by liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS). Separation of 20 amino acids derivatised with these three reagents was studied on reversed-phase chromatography. Linearity, repeatability and limits of detection of the LC-ESI-MS/MS method were determined by analysing FMOC-, butanol- and propyl chloroformate-derivatised lysine, β-aminobutyric acid, threonine and glutamic acid. The limits of detection for the derivatised amino acids (7.5-75 fmol) were as much as 2-60 times lower than those of the corresponding underivatised molecules. The best linearity was observed for amino acids derivatised with propyl chloroformate or butanol (r2 = 0.996-0.999, range = 100-8500 nmol L−1). Propyl chloroformate was the best suited of the reagents tested for the analysis of amino acids with LC-MS/MS and was used for the analysis of amino acids in rat brain microdialysis samples. 相似文献
19.
Analysis of proteoglycans derived sulphated disaccharides by liquid chromatography/mass spectrometry
A method has been developed for the identification and quantitative determination of sulphated disaccharides derived from chondroitin sulphate (CS) and dermatan sulphate (DS) chains attached to proteoglycans (PGs). After digestion with Chondroitinase ABC, the pool of disaccharides can be directly separated by liquid chromatography on a porous graphitized carbon (PGC) column and identified by on-line electrospray mass spectrometry under negative ionization conditions. The relative intensities of the fragment ions obtained by MS/MS allow to distinguish the sulphate position. Calibration with standard disaccharides allows the quantification of the different isomers. The method showed good repeatability in terms of relative standard deviation (RSD < 2%) and linearity between 0.5 and 50 ng (total injected amount) for both 4- and 6-sulphated disaccharides. The limit of detection achieved in full scan mode was 0.1 ng. The methodology was applied to different types of biological samples obtained from patients suffering from chronic lung inflammation such as: lung tissue, bronchoalveolar lavage fluid (BALF), induced sputum and urine. 相似文献
20.
In the experiment, a high-performance liquid chromatography and electrospray ionization-tandem mass spectrometry with selected reaction monitoring was used to simultaneously determine various classes of phytohormones, including indole-3-acetic acid, α-naphthaleneacetic acid, 2-chlorobenzoic acid, 4-chlorobenzoic acid, indole-3-butyric acid, gibberellic acid, 2,4-dichlorophenoxyacetic acid, 2-naphthoxyacetic acid, abscisic acid, 2,3,5-triiodobenzoic acid, uniconazole, paclobutrazol and 2,4-epibassinolide in rape tissues. The analyses were separated by an HPLC equipped with a reversed-phase column using a binary solvent system composed of methanol and water, both containing 0.1% of formic acid. The matrix effect was also considered and determined. The technology was applied to analyze rape tissues, including roots, stems, leaves, flowers, immature pods and rape seeds. The rape tissues were subjected to ultrasound-assisted extraction and purified by dispersive solid-phase extraction, and then transferred into the liquid chromatography system. The detection limit for each plant hormone was defined by the ratio of signal/background noise (S/N) of 3. The results showed perfect linearity (R(2) values of 0.9987-1.0000) and reproducibility of elution times (relative standard deviations, RSDs,<1%) and peak areas (RSDs,<7%) for all target compounds. 相似文献