首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
A simple, rapid, and sensitive non-aqueous capillary electrophoresis procedure for the quantitative determination of matrine and oxymatrine is established. Optimum separation conditions were obtained when the sample was injected under pressure for 3 s at 50 mbar and separated with the buffer containing 70 mM ammonium acetate, 7.0% (v/v) acetic acid, and 10% (v/v) acetonitrile in methanol medium at 25 kV applied voltage. The analytes were detected at 205 nm. The two alkaloids can be separated within 12 min and quantified with high sensitivity. The method was validated in terms of reproducibility, linearity, and accuracy when applied to the analysis of matrine and oxymatrine in Sophora flavescens and its medicinal preparations.  相似文献   

2.
A simple, rapid, and sensitive non-aqueous capillary electrophoresis procedure for the quantitative determination of matrine and oxymatrine is established. Optimum separation conditions were obtained when the sample was injected under pressure for 3 s at 50 mbar and separated with the buffer containing 70 mM ammonium acetate, 7.0% (v/v) acetic acid, and 10% (v/v) acetonitrile in methanol medium at 25 kV applied voltage. The analytes were detected at 205 nm. The two alkaloids can be separated within 12 min and quantified with high sensitivity. The method was validated in terms of reproducibility, linearity, and accuracy when applied to the analysis of matrine and oxymatrine in Sophora flavescens and its medicinal preparations.  相似文献   

3.
《Analytical letters》2012,45(4):651-662
A simple, rapid, and sensitive nonaqueous capillary electrophoresis-electrospray ionization-ion trap-mass spectrometry (NACE-ESI-IT-MS) method was developed for determination of matrine and oxymatrine in Sophora Flavescens and medicinal preparations. The conditions for NACE separation and MS detection were systematically optimized. The optimum NACE buffer contained 30 mM ammonium acetate, 1% acetic acid, and 15% acetonitrile in methanol and the applied voltage on separation capillary was set at 25 kV. Berberine was selected as internal standard. In order to generate a stable electrospray, a sheath liquid (isopropanol/H2O, 2/1, v/v) was used, which could also boost the flow through the ESI needle. The matrine and oxymatrine solutions were introduced into MS detection by a syringe pump for collecting the MSn spectra to investigate the main fragment ions and its possible cleavage pathways. Both matrine and oxymatrine showed good linearity in the concentration ranges from 0.5 to 400 µg/mL, with linear correlation coefficient R > 0.99 and the limit of detections were 37.5 ng/mL for matrine and 50.0 ng/mL for oxymatrine, respectively. The recoveries at different content of Sophora Flavescens were 98.3%–102.9% for MT and 95.3%–100.6% for OMT, which indicates the reliability of this method.  相似文献   

4.
Yang  Xiao-ming  Zhang  Xiu-li  Chen  Yong-chang  Liu  Fang 《Chromatographia》2009,69(5-6):593-596

A sensitive and simple LC method for the quantification of ginkgolic acids in mice plasma has been developed. Following acetonitrile deproteinization, samples were separated on a SinoChrom ODS-AP C18 column. The mobile phase was 3% (v/v) acetic acid water solution–methanol (8:92, v/v) at a flow rate of 1.0 mL min−1. Detection was at 310 nm. Calibration curve was linear over the range of 0.25–50 μg mL−1 with intra- and inter-day precisions (RSD%) of less than 9.5%. The extraction recovery ranged from 87.0 to 90.2% (RSD 2.4–6.4%) for ginkgolic acids. The method was successfully applied to the pharmacokinetic study of ginkgolic acids in mice after oral dosing of 1.0 g kg−1.

  相似文献   

5.
A simple and highly selective method, based upon solid-phase extraction (SPE), ion-pair HPLC and UV absorbance detection, was developed and validated to determine lamivudine, oxymatrine and its active metabolite matrine in dog plasma. The analytes and famotidine (internal standard) were simultaneously extracted from plasma samples by SPE, and separated on a C18 column. The mobile phase consisted of acetonitrile-water (13:87, v/v, 5 mmol L?1 sodium heptanesulfonate, at pH 3.2). The lower limit of quantification of the method was 0.1 mg L?1 for these analytes. The linear calibration curves of the analytes were obtained in the concentration range of 0.1–40 mg L?1. This method was successfully applied to the quantitative determination of plasma concentration of lamivudine, oxymatrine and its active metabolite matrine in dogs after single oral co-administration of 5.0 mg kg?1 lamivudine and 30.0 mg kg?1 oxymatrine.  相似文献   

6.
Rajan  N.  Anver Basha  K. 《Chromatographia》2014,77(21):1545-1552

Ultra-performance liquid chromatography coupled with photodiode-array detection has been used to develop a simple, sensitive, and reproducible reversed-phase method for quantitative determination of fingolimod hydrochloride and all possible process-related impurities. Chromatographic separation was achieved on a Waters Acquity BEH C18 (100 mm × 2.1 mm, 1.7 µm) column. The mobile phase was a gradient prepared from potassium dihydrogen phosphate (20 mM) containing 0.1 % (v/v) triethylamine and adjusted to pH 6.5 with trifluoroacetic acid (component A) and 85:15 (v/v) acetonitrile–water (component B); the gradient program (time (min)/% B) was: 0.01/20, 2.0/20, 6.0/75, 9.0/90, 12.0/90, 14.0/20, 16.0/20; the run time was 16 min and fingolimod hydrochloride and its six impurities were well separated. Eluting compounds were monitored at 220 nm. The method was validated for precision, specificity, linearity, limit of detection, limit of quantification, accuracy, and robustness in accordance with International Conference on Harmonization guidelines. Fingolimod hydrochloride was subjected to oxidative, acid, base, hydrolytic, thermal, and photolytic stress, and analysis was conducted to determine the amounts of related impurities formed.

  相似文献   

7.

A simple stability-indicating reversed-phase liquid chromatographic method with diode-array detection was developed and validated for the quantitative determination of ebastine in tablets and syrup. The LC method was carried out on a C18 column with acetonitrile:phosphoric acid 0.1% pH 3.0 (55:45, v/v) as mobile phase, at a flow rate of 1.2 mL min−1. Ultraviolet detection of ebastine was at 254 nm. A linear response (r = 0.9999) was observed in the range of 10–80 μg mL−1. The RSD values for intra- and inter-day precision studies showed good results (RSD < 2%) and accuracy was greater than 98%. Validation parameters such as specificity and robustness were also determined. The method was found to be stability-indicating and can be applied to quantitative determination of ebastine in tablets and syrup.

  相似文献   

8.
Kan  Y.  G&#;kbulut  A.  Kartal  M.  Konuklugil  B.  Y&#;lmaz  G. 《Chromatographia》2007,66(1):147-152

An accurate, simple, reproducible, and sensitive method for determination of rosmarinic, caffeic, chlorogenic, and gallic acids in 12 Salvia species growing naturally in Anatolia, has been developed and validated. The phenolic acids were separated using a μBondapack C18 column by gradient elution with a flow rate of 1.0 mL min−1, which was adjusted to deliver firstly o-phosphoric acid 0.085% in water, 0.085% in methanol, and 0.085% in 2-propanol (80:10:10, v/v/v), then decreased gradually (60:20:20, v/v/v) during 20 min with a flow rate of 1.0 mL min−1. The samples were monitored at 220 nm for gallic acid and 330 nm for rosmarinic, caffeic, and chlorogenic acids using photo-diode array detection. The linear range of detection for gallic, chlorogenic, caffeic, and rosmarinic acids were between 0.051–101.4, 0.207–103.6, 0.100–100, and 0.201–100.5 μg mL−1, respectively. The linearity, range, peak purity, selectivity, system performance parameters, precision, accuracy, and robustness had also acceptable values. The developed method was applied to the flower, leaf, stem, and root parts of the Salvia species.

  相似文献   

9.
Dogrukol-Ak  D.  Dal  A. G.  Tun&#;el  M. 《Chromatographia》2007,66(1):159-163

A validated capillary zone electrophoretic method for analysis of sotalol is described. Analysis was performed in a fused-silica capillary with 20 mM phosphate buffer (pH 4.20) containing 10% (v/v) acetonitrile as background electrolyte. The applied potential was +20 kV, the injection time 0.08 min, signal detection was at 200 nm, and 3,4-dihydoxybenzylamine was used as internal standard. The method was validated over the concentration range 1.98 × 10−5 to 9.90 × 10−5 M; repeatability was good and there was no interference. Highly satisfactory results were obtained from analysis of tablets and serum, indicating the method is specific, accurate, and precise, and suitable for routine analysis of sotalol in pharmaceutical tablets and in pharmacokinetic studies.

  相似文献   

10.
Bhushan  Ravi  Agarwal  Charu 《Chromatographia》2008,68(11):1045-1051

Direct resolution of the enantiomers of the racemic drugs ketamine and lisinopril has been achieved by TLC. Enantiomerically pure tartaric acid and mandelic acid were used as chiral impregnating reagents and as mobile phase additives. When (−)-mandelic acid was used as chiral impregnating reagent use of ethyl acetate–methanol–water 3:1:1 (v/v) as mobile phase enabled successful resolution of the enantiomers of both compounds. For lisinopril, the mobile phase acetonitrile–methanol–water–dichloromethane 7:1:1:0.5 (v/v) was successful when (+)-tartaric acid was used as impregnating agent. When (+)-tartaric acid was used as mobile phase additive the mobile phase acetonitrile–methanol(+)-tartaric acid (0.5% in water, pH 5)–glacial acetic acid 7:1:1.1:0.7 (v/v) enabled successful resolution of the enantiomers of lisinopril. The effects on resolution of temperature, pH, and the amount of chiral selector were also studied. The separated enantiomers were isolated and identified. Spots were detected with iodine vapour. LODs were 0.25 and 0.27 μg for each enantiomer of ketamine with (+)-tartaric acid and (−)-mandelic acid, respectively, whereas for lisinopril LODs were 0.14 and 0.16 μg for each enantiomer with (+)-tartaric acid (both conditions) and (−)-mandelic acid, respectively.

  相似文献   

11.

This paper describes development and validation of a high-performance liquid chromatographic method for simultaneous analysis of tramadol hydrochloride (TR) and aceclofenac (AC) in a tablet formulation. When the combination formulation was subjected to ICH-recommended stress conditions, adequate separation of TR, AC, and the degradation products formed was achieved on a C18 column with 65:35 (v/v) 0.01 M ammonium acetate buffer, pH 6.5—acetonitrile as mobile phase at a flow rate of 1 mL min−1. UV detection was performed at 270 nm. The method was validated for specificity, linearity, LOD and LOQ, precision, accuracy, and robustness. The method was specific against placebo interference and also during forced degradation. The linearity of the method was investigated in the concentration ranges 15–60 μg mL−1 (r = 0.9999) for TR and 40–160 μg mL−1 (r = 0.9999) for AC. Accuracy was between 98.87 and 99.32% for TR and between 98.81 and 99.49% for AC. Because degradation products were well separated from the parent compounds, the method was stability-indicating.

  相似文献   

12.

A new method involving matrix solid-phase dispersion (MSPD) extraction and UPLC in conjunction with photodiode array detection was developed for the rapid and simple determination of Sudan dyes in chili powder. Separation of Sudan I, Sudan II, Sudan III, and Sudan IV was achieved within 2 min on the 1.7 μm Acquity UPLC BEH C18 column by using gradient elution with a mobile phase consisting of acetonitrile–water at a flow rate of 0.5 mL min−1. Optimization of MSPD extraction parameters, such as type of solid sorbent and elution solvent were carried out. Optimal conditions selected for MSPD extraction were 0.25 g of sample, 0.5 g of silica gel as solid sorbent, and 7 mL of acetonitrile–methanol (9:1, v/v) as eluting solvent. Limits of detection ranged between 0.25 and 0.30 mg kg−1 depending on the dye involved. All analytes provided average recoveries from spiked (at 1, 1.5, and 2 mg kg−1) chili powder samples ranging from 81 to 106%. The method was applied to the analysis of chili powder samples obtained from different countries.

  相似文献   

13.
Li  Ting-Ting  Fang  Fang  Chen  Xi-Jing  Ji  Hui 《Chromatographia》2009,70(11):1755-1758

A sensitive, specific and rapid high-performance liquid chromatography method was developed for determination of 5,6,7,8,3′,4′-hexamethoxy-3-sulfonyl flavone in rat plasma. A simple methanol-induced protein precipitation was applied to extract 5,6,7,8,3′,4′-hexamethoxy-3-sulfonyl flavone and Picroside II (the internal standard) from rat plasma. Chromatographic separation was achieved on a Hypersil ODS2 analytical column (200 mm × 4.6 mm, 5 μm) with acetonitrile–0.04% triethylamine solution (adjusted to pH 5.8 using phosphoric acid) (24:76, v/v) as mobile phase. The calibration curves were linear over the range of 0.2–40 μg mL−1. Absolute recoveries of 5,6,7,8,3′,4′-hexamethoxy-3-sulfonyl flavone were 82.7–95.9% from rat plasma. The intra- and inter-day relative standard deviation precisions were less than 5 and 9%, respectively. The method was successfully applied to the pharmacokinetic study of 5,6,7,8,3′,4′-hexamethoxy-3-sulfonyl flavone in rats after intravenous administration.

  相似文献   

14.
Zou  Jian-Jun  Fan  Hong-Wei  Guo  Da-Qing  Li  Ying-Bin  Lin  Song  Zhu  Yu-Bing  Yu  Cui-Xia  Zhou  Jie  Liu  Jiang-Hui  Hu  Yun-Fang 《Chromatographia》2009,70(11):1581-1586

A sensitive and specific liquid chromatography-tandem-mass spectrometry method was developed and validated for the simultaneous determination of clopidogrel and its carboxylic acid metabolite (SR26334) in human plasma using nateglinide and pioglitazone as internal standards. Analytes were extracted from 0.50 mL of plasma using diethyl ether–n-hexane (4:1, v/v). Chromatographic separation was performed on a Teknokroma C18 column with a mobile phase of methanol–water (containing 0.1% formic acid) (80:20, v/v) at a flow rate of 0.20 mL min−1 within 5.6 min. Linearity was established over the concentration range of 0.005–5 ng mL−1 for clopidogrel and 20–2,500 ng mL−1 for SR26334. Intra- and inter-batch standard deviations were less than 9.2% and the accuracy of this assay was found to fall within an acceptable range ≤10.0%. The method was successfully applied to the therapeutic drug monitoring of clopidogrel.

  相似文献   

15.

An accurate, simple, reproducible, and sensitive liquid chromatographic method was developed and validated for the captopril determination in controlled release tablets. The analyses were performed at room temperature on a reversed-phase Phenomenex Luna C18 column (250 mm × 4.6 mm). The mobile phase was composed of water:methanol (45:55; v/v) pH 2.5, and it was eluted isocratically at a 1.0 mL min−1 flow rate. The method was validated in terms of specificity, linearity, quantification limit, detection limit, accuracy, precision and robustness. The response was linear in the range 0.3–1.5 mg mL−1 (r 2 = 0.9983). The relative standard deviation values for inter-and intra-day precision were 0.77% and 0.50%, respectively. Recoveries ranged between 97.7 and 99.1%. The method was successfully applied for the determination of captopril in the developed formulations.

  相似文献   

16.
Bari  P. D.  Rote  A. R. 《Chromatographia》2009,69(11):1469-1472

Two new, rapid, precise, accurate and specific chromatographic methods were described for the simultaneous determination of olmesartan medoxomil and hydrochlorothiazide in combined tablet dosage forms. The first method was based on reversed phase liquid chromatography using an Eurosphere 100 RP C18 column (250 × 4.6 mm ID, 5 μm). The mobile phase was methanol–0.05% o-phosphoric acid (60:40 v/v) at a flow rate of 1.0 mL min−1. Commercially available tablets and laboratory mixtures containing both drugs were assayed and detected using a UV detector at 270 nm. The second method involved silica gel 60 F254 high performance thin layer chromatography and densitometric detection at 254 nm using acetonitrile–ethyl acetate–glacial acid (7:3:0.4 v/v/v) as the mobile phase. Calibration curves ranged between 200–600 and 125–375 ng spot−1 for olmesartan and hydrochlorothiazide, respectively.

  相似文献   

17.
Shen  Mingyue  Xie  Mingyong  Nie  Shaoping  Wang  Yuanxing  Chen  Junhui  Li  Chang  Li  Jing 《Chromatographia》2008,67(11):999-1001

High speed counter-current chromatography in semi-preparative scale was used to separate and purify ergosta-4,6,8(14),22-tetraen-3-one from Ganoderma atrum, a famous traditional Chinese medicine. A two-phase solvent system composed of a mixture of n-hexane–ethanol–water (6: 5: 1, v/v/v) was used and the separation conditions were optimized. In a typical run in less than 400 min, 100 mg of samples can be separated to yield 14 mg of ergosta-4,6,8(14),22-tetraen-3-one with 99.1% purity. The structure of this compound was elucidated by UV, EI-MS, 1H NMR and 13C NMR.

  相似文献   

18.

A simple, isocratic, rapid, and accurate reversed-phase high-performance liquid chromatographic method has been established for quantitative determination of zonisamide. The method is also applicable to determination of related substances in the bulk drug. Chromatographic separation was achieved on a 250 mm × 4.6 mm, 5-μm particle, C18 column; the mobile phase was a 70:30 (v/v) mixture of 0.1% (v/v) aqueous triethylamine, adjusted to pH 2.5 with dilute orthophosphoric acid, and acetonitrile. Chromatographic resolution of zonisamide from its potential impurity, A, was found to be >2. The limits of detection and quantification of zonisamide and impurity A were 0.04 and 0.12 μg mL−1, respectively, for 20 μL injection volume. Recovery of zonisamide ranged from 98.5 to 101.2% and recovery of impurity A from a sample of zonisamide ranged from 97.4 to 102.7%. The method was validated for linearity, accuracy, precision, and robustness.

  相似文献   

19.
Deng  Weijie  Zhang  Xiangnian  Sun  Zhiping  Yin  Jilin  Zhou  Zheng  Han  Liping  Zhao  Shujin 《Chromatographia》2012,75(11):629-633

A new and simple high-performance liquid chromatography with evaporative light scattering detector method for the determination of Kryptofix 2.2.2 (K-222) in the radiopharmaceuticals of 2-deoxy-2-[18F]fluoro-d-glucose ([18F]FDG) and 3′-deoxy-3′-[18F]fluorothymidine ([18F]FLT) was developed. A C18 column was used and the mobile phase was 10 % (v/v) methanol and 90 % (v/v) water (0.1 % trifluoroacetic acid, v/v) at a flow rate of 0.2 mL min−1. The drift tube temperature was 40 °C. The pressure of nebulizing gas (N2) was 3.0 bar. The gain was 10. Good separation of K-222 from main related substances could be achieved. Excellent linearity (r 2 = 0.9995) was obtained over the range of 5–100 μg mL−1. The precision ranged from 0.68 to 5.16 % (RSD) and the accuracy ranged from −3.05 to 2.62 % (RE). The limit of detection was 2 μg mL−1. This method offers simple, rapid and quantitative detection of K-222, thus making it acceptable for routine determination.

  相似文献   

20.
Dinkci  N.  Akal&#;n  A. S.  G&#;nc  S.  &#;nal  G. 《Chromatographia》2007,66(1):45-49

Reverse-phase HPLC was assessed for the determination of most important organic acids in Kargı Tulum cheese. The method with a simple treatment of the sample succeeded in eluting nine organic acids in a single chromatographic run with the aid of buffer–acetonitrile gradient. A gradient programme using a mobile phase of aqueous 0.5% (w/v) (NH4)2HPO4–0.4% (v/v) acetonitrile at pH 2.24 was used to separate organic acids on a C18 column. The best flow rate–time program was applied to take the chromatogram in 35 min with a high linearity and excellent repeatability. The main organic acids of Kargı Tulum cheese were lactic, acetic, citric, propionic and formic acids. Pyruvic, uric and orotic acids were found to be lower in content while butyric acid was not detected in the samples.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号