首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Aksoy  B.  K&#;&#;&#;kg&#;zel  &#;.  Rollas  S. 《Chromatographia》2007,66(1):57-63

The objective of the current study was the development and subsequent validation of a simple, sensitive, precise and stability-indicating reversed-phase HPLC method for the determination of ciprofloxacin HCl in pharmaceutical dosage forms in the presence of its potential impurities. The chromatographic separation of ciprofloxacin HCl and its related compounds was achieved on an Inertsil ODS3 column using UV detection. The optimized mobile phase consisted of phosphoric acid solution: acetonitril. The proposed method provided linear responses within the concentration range 250–750 μg mL−1 for ciprofloxacin HCl and 0.5–1.5 μg mL−1 for its related compounds. LOD and LOQ values for the active substance were 5.159 and 15.632 μg mL−1, respectively. Correlation coefficients (r) of the regression equations for the impurities were greater than 0.99 in all cases. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 1% in all instances. No interference from any components of pharmaceutical dosage forms or degradation products was observed.

  相似文献   

2.
Uslu  Bengi  &#;zden  Tugba 《Chromatographia》2013,76(21):1487-1494

High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL−1 of ENL, 0.260–399 μg mL−1 of HCZ for HPLC system and 0.270–399 μg mL−1 of ENL and 0.065–249 μg mL−1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL−1 and 31.477 ng mL−1 for HCZ, 2.804 ng mL−1 for ENL and 2.943 ng mL−1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.

  相似文献   

3.

A simple, rapid, and stability-indicating reversed-phase high-performance liquid chromatographic (LC) method for analysis for dutasteride has been successfully developed. Chromatography was performed on a 150 mm × 4.6 mm C18 column with acetonitrile–water 60:40 (v/v) as isocratic mobile phase at 1.0 mL min−1. Ultraviolet detection of dutasteride was at 210 nm. Its retention time was approximately 10 min and its peak was symmetrical. Response was a linear function of concentration over the range 0.2–1 μg mL−1 (R 2 = 0.997) and the limits of detection and quantitation were was 0.05 and 0.10 μg mL−1, respectively. The method was validated for linearity, precision, repeatability, sensitivity, and selectivity. Selectivity was validated by subjecting dutasteride stock solution to photolytic, acidic, basic, oxidative, and thermal degradation. The peaks from the degradation products did not interfere with that from dutasteride. The method was used to quantify dutasteride in pharmaceutical preparations.

  相似文献   

4.

A liquid chromatography method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical formulations. Optimum separation was achieved in less than 10 min using a C8 column (200 mm × 4.6 mm i.d., particle size 5 μm) and elution was accomplished by the application of a dual-mode solvent and flow-rate gradient system. Detection was carried out using a diode-array detector set at 240 nm. Canrenone was used as internal standard. The method was economical in terms of the time taken and the amount of solvent used for each analysis. It was also validated with respect to system suitability, specificity, limit of quantitation and detection, linearity, precision, accuracy, and recovery, respectively. The limits of quantitation for ezetimibe and simvastatin were 0.2 and 3 μg mL−1, respectively. Limits of detections were found to be 0.05 and 0.5 μg mL−1, for ezetimibe and simvastatin, respectively. The developed method was successfully applied to the simultaneous determination of ezetimibe and simvastatin in pharmaceutical formulations.

  相似文献   

5.
Xiong  Xunyu  Zhang  Qunzheng  Xiong  Fengmei  Tang  Yuhai 《Chromatographia》2008,67(11):929-934

A simple and sensitive method was developed for the determination of three nonsteroidal anti-inflammatory drugs (NSAIDs)—ibuprofen, naproxen and fenbufen in human plasma. The method involved in column liquid chromatographic separation and chemilumenescence (CL) detection based on the CL reaction of NSAIDs, potassium permanganate (KMnO4) and sodium sulfite (Na2SO3) in sulfuric acid (H2SO4) medium. The chromatographic separation was carried out using a reversed-phase C18 column, which allowed the selective determination of the three medicines in the complicated samples. The special features of the CL detector provided lower LOD for determination than that of existing chromatographic alternatives. The results indicated that the linear ranges were 0.01–10.0 μg mL−1 for ibuprofen, 0.001–1.0 μg mL−1 for naproxen, and 0.01–10.0 μg mL−1 for fenbufen. The limits of detection were 0.5 ng mL−1 for ibuprofen, 0.05 ng mL−1 for naproxen and 0.5 ng mL−1 for fenbufen (S/N = 3). All average recoveries were in the range of 90.0–102.3%. Finally, the method had been satisfactorily applied for the determination of ibuprofen, naproxen and fenbufen in human plasma samples.

  相似文献   

6.
Zhang  Beibei  Chen  Zuanguang  Yu  Yanyan  Yang  Jianping  Pan  Jianbin 《Chromatographia》2013,76(13):821-829

In this paper, we describe a compact and low-cost light-emitting diode-induced fluorescence (LED-IF) detection coupled to microchip electrophoresis for the determination of sulfonamides in pharmaceutical formulations and rabbit plasma. Three fluorescein isothiocyanate-labeled sulfonamides in rabbit plasma were separated in the running buffer of 40 mM phosphate buffer (pH 7.0) at the separation voltage of 2.0 kV, and detected by LED-IF detector in which the high-power blue LED was driven at the constant current of 150 mA and the emitted fluorescence over 510 nm was collected by a planar photodiode. The linear concentration ranged from 2.0 to 125.0 μg mL−1, both for sulfadiazine and sulfamethazine with the correlation coefficients (r 2) of 0.995 and 0.997, respectively, and from 2.0 to 100.0 μg mL−1 with the correlation coefficients (r 2) of 0.997 for sulfaguanidine. The limits of detection for the three sulfonamides were 0.36–0.50 μg mL−1 (S/N = 3). Intra-day and inter-day precision of migration time and peak area for the determination of sulfonamides were <4.5 %. This method has been successfully applied to the analysis of sulfonamides in pharmaceuticals, and could be used to study the pharmacokinetics of sulfonamides in rabbit.

  相似文献   

7.
Kadioglu  Yucel  Demirkaya  Fatma 《Chromatographia》2007,66(1):169-172

The present work describes the methodology and validation of gas chromatography with flame ionization detection (GC-FID) for the determination of carbamazepine with internal standard (diazepam) in pharmaceutical preparations. The method was linear from 2–30 μg mL−1. The RSD values for precision was less than 9%, accuracy (relative error) was better than 11% (n = 6). The developed method was successfully applied for the assay of pharmaceutical dosage forms which do not require any preliminary separation or treatment of the samples. The RSD values for Tegretol® tablets (200 mg) and Karberol® tablets (200 mg) was found to be 4.03 and 3.25%, respectively. The results obtained from this method were compared with the reference method (LC) reported in literature and no significant difference was found statistically.

  相似文献   

8.

A stability-indicating ultra-high-performance liquid chromatography (UHPLC) method with a diode array detector was developed and validated for the determination of cis/trans isomers of perindopril l-arginine in bulk substance and pharmaceutical dosage form. The separation was achieved on a Poroshell 120 Hilic (4.6 × 150 mm, 2.7 µm) column using a mobile phase composed of acetonitrile–0.1 % formic acid (20:80 v/v) at a flow rate of 1 mL min−1. The injection volume was 5.0 µL and the wavelength of detection was controlled at 230 nm. The selectivity of the UHPLC-DAD method was confirmed by determining perindopril l-arginine in the presence of degradation products formed during acid–base hydrolysis and oxidation as well as degradation in the solid state, at an increased relative air humidity and in dry air. The method’s linearity was investigated in the ranges 0.40–1.40 µg mL−1 for isomer I and 0.40–2.40 µg mL−1 for isomer II of perindopril l-arginine. The UHPLC-DAD method met the precision and accuracy criteria for the determination of the isomers of perindopril l-arginine. The limits of detection and quantitation were 0.1503 and 0.4555 µg mL−1 for isomer I and 0.0356 and 0.1078 µg mL−1 for isomer II, respectively.

  相似文献   

9.
Xu  Fan  Xu  Guili  Shang  Beicheng  Yu  Fang 《Chromatographia》2009,69(11):1421-1426

A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min−1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL−1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL−1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL−1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.

  相似文献   

10.
Horsk&#;  Jana  Ginterov&#;  Pavl&#;na  &#;ev&#;&#;k  Juraj  Petr  Jan 《Chromatographia》2014,77(21):1477-1482

Imatinib, bosutinib, dasatinib, pazopanib, erlotinib, canertinib and vatalanib are new developed anticancer drugs, especially for treatment of leukemia. In this article, a fast and high throughput capillary zone electrophoresis method has been developed and validated for analysis of these new drugs in pharmaceutical formulas. The method can be easily utilized for determination of all the drugs in one run what is advantageous for the quality control in pharmaceutical industry because there is no need for changing and optimization of separation conditions when changing the analyte. The separation was performed using an uncoated fused silica capillary with 100 mmol L−1 sodium phosphate buffer pH 2.75, voltage of 25 kV, hydrodynamic injection time of 5 s by 50 mbar, and detection at 214 nm. Under these conditions, the analysis took about 8 min. The validation of all the drugs resulted in recoveries in the range of 84–100 %. The method showed to be precise for all the drugs with RSDs of migration times lower than 0.9 % (interday precision). A very good linearity in the validated range (5–100 μg mL−1) and the limits of detection (LODs) in the range of 0.5–2.0 (μg mL−1) were achieved. Finally, we proved that the method is robust by the Youden’s test. Therefore, our method can be successfully applied for analysis of the real pharmaceutical samples.

  相似文献   

11.

A reversed phase LC method was developed and validated to analyze the in vitro release of AZT from microemulsions. A mobile phase of acetonitrile:water (15:85) was used. The method validation showed good selectivity and linearity (r = 0.9993) for sample concentrations ranging from 0.6 to 100.0 μg mL−1. The RSD values (0.7–4.3%) and percentage recovery (88.1–109.8%) were within acceptable limits. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.012 and 0.041 μg mL−1. Quantitative analysis of the values obtained in the drug release assay indicates that the microemulsions used promote sustained release of AZT, which follows a Fickian diffusion mechanism.

  相似文献   

12.

A reversed-phase ion-pairing liquid chromatographic method was developed and validated for the assay of Fe(II) in ferrous bisglycinate (Fe-bis-gly) capsules using 4-(2-pyridylazo) resorcinol reagent. The analysis was carried out using a Gemini RP-18 (150 mm × 4.6 mm I.D., particle size 5 μm) analytical column; the mobile phase consisted of a mixture of acetonitrile–water (28:72 v/v) containing 1 mM tetrabutylammonium hydrogensulfate and 1% phosphate buffer (pH 8.0). The flow rate was 1.0 mL min−1 and the detection was achieved with a photodiode array (PDA) detector at 706 nm. The specificity of the method was proved using stress conditions and evaluated using a PDA detector. The data validation showed that the method is specific, fast, accurate, and reproducible for the determination of Fe-bis-gly in dosage form. The response was linear over a range of 1.0–2.6 μg mL−1 (r = 0.9999). The accuracy of the method ranged from 98.02 to 102.75%. The RSD values for intra- and inter-day precision studies were below 1.3 and 1.1%, respectively. There was no interference of the excipients on the determination of the active pharmaceutical ingredient.

  相似文献   

13.
Kurbanoglu  Sevinc  Gumustas  Mehmet  Uslu  Bengi  Ozkan  Sibel A. 《Chromatographia》2013,76(21):1477-1485

A RP-LC method is presented, which is sensitive and selective for the simultaneous determination of enalapril–lercanidipine and enalapril–nitrendipine binary mixtures in their pharmaceutical dosage forms. The analyte peaks were detected using the LC method with the mobile phase ratio of methanol: water (70:30 v/v, pH 3.0) and a 1.0 mL min−1 flow rate. The detection wavelength was selected at 210 nm using photo diode array detector and column temperature was optimized to 30 °C. Linearity was obtained at different concentration ranges for all working pharmaceutically active compounds between 0.5 and 25 μg mL−1. The proposed methods were extensively validated according to USP 27 requirements and ICH guidelines. The methods were applied to the analysis of pharmaceutical dosage forms containing binary mixtures of enalapril–lercanidipine and enalapril–nitrendipine. Moreover, the proposed methods were applied for the degradation studies of the selected compounds. Degradation studies were conducted using stress conditions such as UV light, acidic and alkaline hydrolysis, oxidation and heat in oven, to evaluate the ability of the separation of the response of standard compounds from their degradation products.

  相似文献   

14.
Scher&#;bl  Rosmarie  Manns  Detlef  Heilmann  J&#;rg  Franz  Gerhard 《Chromatographia》2013,76(21):1537-1543

A HPLC and a HPTLC-densitometric method were developed for the quantification of prim-O-glucosylcimifugin and 4′-O-β-d-glucosyl-5-O-methylvisamminol the major chromone glucosides in the roots of Saposhnikovia divaricata. The validation of both methods resulted in comparable parameters regarding stability, specificity, linearity, robustness, precision and recovery, whereas complementary advantages were obtained concerning LOD and LOQ. The HPTLC-based densitometry revealed a lower LOD (1.11 versus 4.37 μg mL−1 in HPLC) and LOQ (3.36 versus 13.24 μg mL−1 in HPLC) for prim-O-glucosylcimifugin, whereas the HPLC resulted in a lower LOD (1.00 versus 4.10 μg mL−1 in HPTLC-densitometry) and LOQ (3.04 versus 12.46 μg mL−1 in HPTLC-densitometry) for 4′-O-β-d-glucosyl-5-O-methylvisamminol. Both methods revealed nearly matching contents of the chromones after analysis of different commercially available batches of Saposhnikoviae divaricatae radix with a total content for both chromone glycosides in the range from 0.31 ± 0.011 to 0.56 ± 0.021 % determined by HPLC and between 0.34 ± 0.011 and 0.61 ± 0.009 % determined by HPTLC. The plant material cultivated in Germany showed a very similar content and ratio of both chromone glucosides in comparison to the standard batches originating from China.

  相似文献   

15.
Liu  Yongmei  Liao  Mengya  Zhang  Cuiwei  Bai  Yuli  Song  Honglian  Zhang  Yiwen  Wang  Xin 《Chromatographia》2015,78(23):1485-1489

A precise and sensitive LC method for the determination of repertaxin enantiomeric purity has been developed and validated. Baseline separation with a resolution higher than 2.0 was accomplished within 20 min using a Chiralpak AD-H column (250 × 4.6 mm; particle size 5 μm) and n-hexane:2-propanol (90:10 v/v) as mobile phase at a flow rate of 1 mL min−1. Eluted analytes were monitored by UV detection at 260 nm. The effects of mobile phase composition, temperature and flow rate on enantiomeric selectivity and on resolution of enantiomers were investigated. Calibration curves were plotted within the concentration range between 0.002 and 1.0 mg mL−1 (n = 3), and relative standard deviation (RSD) of the inter-batch assay and intra-batch assay was less than 1.27 and 1.16 %. LOD and LOQ for repertaxin were 0.65 and 2.19 μg mL−1; those for its enantiomer were 0.70 and 2.34 μg mL−1, respectively. The method was evaluated and validated by analysis of bulk samples of repertaxin of different enantiomeric purity. It was demonstrated that the method was accurate, robust, and sensitive, and enabled practical analysis of real samples.

  相似文献   

16.
Zhang  Chunni  Sun  Xinguang  Zhao  Yang  Zhang  Jie  Ma  Fengxia  Long  Zhen  Liang  Lina  Wang  Yingzi  Ma  Baiping 《Chromatographia》2016,79(19):1381-1386

In this work, a simple and rapid high-performance liquid chromatography coupled with charged aerosol detector (HPLC-CAD) method was first developed for the quantitation of toosendanin, the major constituent of the dried fruit of Melia toosendan Sieb. Et Zucc. Samples were well separated on an Agilent ZOBAX SB C18 column (4.6 mm × 250 mm, 5 μm) by isocratic elution using 33 % acetonitrile and 67 % water containing 0.1 % formic acid (v/v) at the flow rate of 1.0 mL min−1. The nitrogen inlet pressure of the charged aerosol detector (CAD) was 35 psi, and the nebulizer chamber temperature was 35 °C. The established method was well validated. Satisfactory linearity was achieved (r 2 > 0.9997) in a relatively wide concentration range (5–500 μg mL−1). The intra- and inter-day precisions, repeatability, and stability of the method were good with relative standard deviations (RSDs) of 1.05, 2.23, 2.39, and 2.03 %, respectively. The method also showed excellent accuracy with recovery rates of 97.42–101.87 %. Particularly, CAD showed much better sensitivity (LOQ 4 μg mL−1) than evaporative light scattering detector (LOQ 100 μg mL−1) for toosendanin’s determination. The established method was further applied in the quantitation of toosendanin in 39 batches of raw and stir-fried toosendan fructus. The HPLC-CAD method was rapid and accurate, and could be used for the routine analysis and quality control of toosendan fructus and its preparations.

  相似文献   

17.

A simple and rapid development of a stability-indicating LC method for determination of chloroquine diphosphate in the presence of its hydrolysis, oxidative and photolysis degradation products is described. Stress testing showed that chloroquine diphosphate was degraded under basic conditions and by photolytic treatment but was stable under the other stress conditions investigated. Separation of the drug from its degradation products was achieved with a Nova Pack C18 column, 0.01 M PIC B7 and acetonitrile (40:60 v/v) pH 3.6, as mobile phase. Response was linear over the range 0.08–5.70 μg mL−1 (= 0.996), with limits of detection and quantification (LOD and LOQ) of 0.17 and 0.35 μg mL−1, respectively.

  相似文献   

18.
19.

This paper discusses the development of a stability-indicating reversed-phase LC method for analysis of cholecalciferol as the bulk drug and in formulations. The mobile phase was acetonitrile–methanol–water 50:50:2 (v/v). The calibration plot for the drug was linear in the range 0.4–10 μg mL−1. The method was accurate and precise with limits of detection and quantitation of 64 and 215 ng, respectively. Mean recovery was 100.71%. The method was used for analysis of cholecalciferol in pharmaceutical formulations in the presence of its degradation products and commonly used excipients.

  相似文献   

20.
Fang  Lina  Wang  Qiudi  Bi  Kaishun  Zhao  Xu 《Chromatographia》2016,79(23):1659-1663

A sensitive and simple HPLC method for simultaneous determination of PAC-1 (first procaspase-activating compound), phenol red, and permeability markers (carbamazepine and furosemide) in perfusion samples was developed and validated to assess intestinal absorption of PAC-1 using single-pass intestinal perfusion technique (SPIP) in rats. The chromatographic separation was carried out on a Kromasil C18 column (150 mm × 4.6 mm, 5 μm) with acetonitrile–methanol–30 mmol L−1 phosphate buffer (pH 3.0, 25:10:65, v/v/v) as mobile phase at a flow rate of 1.0 mL min−1, and the wavelength of the UV detector was set at 281 nm. The calibration curves were linear in the ranges of 2.40–48.0 μg mL−1 for PAC-1; 3.60–72.0 μg mL−1 for carbamazepine; 3.20–64.0 μg mL−1 for furosemide, and 4.80–96.0 μg mL−1 for phenol red (r > 0.999). Both the intra- and inter-day precisions (RSD%) of all analytes were less than 6.8 % at three concentration levels, while accuracy ranged from 95.4 to 104.5 %. Data obtained in all method validation studies indicated that the method was suitable for the intended purpose. The effective permeability values (P eff) considering water flux with the help of non-permeable marker phenol red was calculated to be 0.42 × 10−4, 0.62 × 10−4, 0.32 × 10−4 cm s−1 for PAC-1; 0.72 × 10−4, 0.77 × 10−4, 0.52 × 10−4 cm s−1 for carbamazepine; 0.20 × 10−4, 0.16 × 10−4, 0.12 × 10−4 cm s−1 for furosemide in duodenum, jejunum and ileum, respectively. The P eff value can be increased by co-perfusion with verapamil, indicating that absorption of PAC-1 is efficiently transported by P-glycoprotein (P-gp) in the gut wall.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号