A new, sensitive, stability indicating gradient RP-LC related substances and assay method has been developed for the quantitative determination of entacapone in bulk drugs. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination of buffer and acetonitrile. Buffer consisted of 0.1% orthophosphoric acid, delivered in a gradient mode and quantitation was carried out using ultraviolet detection at 220 nm with a flow rate of 1.5 mL min−1. In the developed LC method the resolution (R s ) between entacapone and its three potential process impurities were found to be >2.0. Regression analysis showed an r 2 value (correlation coefficient) >0.99 for entacapone and its three potential impurities. This method was capable to detect all three process impurities of entacapone at a level of 0.003% with respect to test concentration of 0.5 mg mL−1 for a 20 μL injection volume. The inter- and intra-day precision values for all three impurities and for entacapone was found to be within 2.0% RSD. The method has shown good and consistent recoveries for entacapone in bulk drugs (99.2–101.5%) and its three impurities (99.5–102.2%). The test solution was found to be stable in diluent for 48 h. The drug substances were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress, base stress and oxidative conditions. The stressed test solutions were assayed against the qualified working standard of entacapone and the mass balance in each case was close to 99.7% indicating that the developed method was stability-indicating. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.
相似文献A novel liquid chromatographic method for analysis three potential impurities in brimonidine tartrate drug substance has been developed and validated. Efficient chromatographic separation was achieved on a C8 column (250 mm × 4.6 mm, 5-μm particles) with a simple mobile-phase gradient at a flow rate of 1.0 mL min−1. Quantification was achieved by use of ultraviolet detection at 248 nm. Resolution between brimonidine tartrate and its three potential impurities was greater than 3.0. Regression analysis showed the r value (correlation coefficient) was >0.999 for brimonidine and its three impurities. The method was capable of detecting all three impurities of brimonidine tartrate at levels below 0.07 μg in a test concentration of brimonidine tartrate of 1.0 mg mL−1 and for an injection volume of 10 μL. A solution of brimonidine tartrate in acetonitrile–water 2:8 (v/v) was stable for 48 h. The drug was subjected to stress conditions as prescribed by the ICH. Degradation was found to occur slightly under oxidative stress conditions but the drug was stable to aqueous, acidic, and basic hydrolysis, and photolytic and thermal stress. The assay of the stressed samples was calculated relative to a qualified reference standard and the mass balance was found close to 99.8%. The method was validated for linearity, accuracy, precision, and robustness.
相似文献A simple, rapid, and stability-indicating reversed-phase high-performance liquid chromatographic (LC) method for analysis for dutasteride has been successfully developed. Chromatography was performed on a 150 mm × 4.6 mm C18 column with acetonitrile–water 60:40 (v/v) as isocratic mobile phase at 1.0 mL min−1. Ultraviolet detection of dutasteride was at 210 nm. Its retention time was approximately 10 min and its peak was symmetrical. Response was a linear function of concentration over the range 0.2–1 μg mL−1 (R 2 = 0.997) and the limits of detection and quantitation were was 0.05 and 0.10 μg mL−1, respectively. The method was validated for linearity, precision, repeatability, sensitivity, and selectivity. Selectivity was validated by subjecting dutasteride stock solution to photolytic, acidic, basic, oxidative, and thermal degradation. The peaks from the degradation products did not interfere with that from dutasteride. The method was used to quantify dutasteride in pharmaceutical preparations.
相似文献A novel, simple and reliable reversed-phase liquid chromatography (LC)–spectrophotometric UV stability-indicating method was developed and validated for the simultaneous assay of marbofloxacin, clotrimazole and dexamethasone acetate in the presence of their impurities and degradation products in a pharmaceutical formulation for veterinary use. A C18 (75 × 4.6 mm, 4 µm) column was used with an acetonitrile–ammonium acetate mixture as mobile phase delivered with gradient elution. A diode-array detection was used in the 200–400 nm range and the detection wavelength was set at 260 nm. Validation carried out on the pharmaceutical dosage form, according to Veterinary International Conference on Harmonization guidelines, demonstrated excellent specificity, linearity, precision, accuracy and robustness. Excellent specificity with respect to vehicle and degradation products obtained after forced degradation (i.e., oxidation, acid, alkaline and thermal degradation) was demonstrated. As for linearity, the LC–UV assay method is applicable in the 0.180–0.420 mg mL−1 concentration range for marbofloxacin (r 2 = 0.99), 0.060–0.140 mg mL−1 for dexamethasone acetate (r 2 = 0.97) and 0.600–1.400 mg mL−1 for clotrimazole (r 2 = 0.98). Very good repeatability (RSD < 0.8 %) and inter-day precision (RSD < 2.5 %) were observed for all analytes. Accuracy was in the 93–104 %, 98–111 % and 99–108 % confidence interval (95 %) for marbofloxacin, dexamethasone acetate and clotrimazole, respectively. The variations (±20 %) of mobile phase flow rate and pH, and oven column temperature did not exhibit an impact on the analyte content accuracy, demonstrating the robustness of the method. The LC–UV method here developed and validated may be used routinely for quality control.
相似文献A simple reverse-phase method for the selective quantification of pitavastatin calcium (PIT) and its related substances was developed. The method demonstrated an excellent separation between PIT and each of 15 impurities (including its isomers and degradants) within a short run time of 12 min by HPLC. A rapid resolution similar to that of UHPLC was achieved using high flow rate on superficially porous C18 stationary phase. A synergistic combination of quality by design approach and use of a superficially porous column delivered a HPLC method with ultra-high performance. Forced degradation studies proved the method to be highly specific (mass balance > 98 %) and the structures of major degradation products were proposed based on LC–MS analysis. The results of validation proved the method to be highly precise (%RSD < 4), accurate (recoveries in range of 100 ± 7 %), linear (r 2 > 0.999) and sensitive (LOQ ≤ 0.02 % and LOD ≤ 0.005 %) for all the impurities and drug. Use of multivariate analysis helped to incorporate high robustness in the method. The method is valuable for quantification of PIT and its related substances in both drug substance and oral solid dosage form.
相似文献A selective and validated stability-indicating LC method was developed for the kinetic study of the degradation of PAC-1, which was carried out in aqueous solutions at 37, 60, 80 and 100 °C with pH 1.5–9.0. Separation was performed on a Kromasil C18 column with acetonitrile–water–fomic acid (30:70:0.1, v/v/v) as mobile phase with a flow rate of 1.0 mL min−1 at 281 nm. The degradation rate obtained indicated a first-order reaction law and the activation energy (E a) was calculated. The results showed that temperature and pH values were significant factors affecting the degradation of PAC-1. An unknown degradation product in alkaline condition was isolated using a reverse-phase semi-preparative LC system. The structure of the degradation product is identified as 2-hydroxy-3-(2-propenyl)-[[2-hydroxy-3-(2-propenyl)phenyl]methylene]hydrazone utilizing the 1H NMR, 13C NMR, IR and Q-TOF-MS techniques.
相似文献A simple, selective, precise, rapid and accurate stability-indicating high-performance thin-layer chromatography (HPTLC) method was developed and validated for the estimation of dapagliflozin and metformin in tablet dosage form. In this work, methanol–ethyl acetate–ammonium acetate (6:4:0.1, V/V) as the mobile phase and aluminum-backed TLC plates pre-coated with 250 µm layer of silica gel 60F254 as the stationary phase were used for the estimation of dapagliflozin and metformin. The wavelength selected for detection was 220 nm. The linearity range was found to be 20–100 ng/spot (r2 = 0.9985) for dapagliflozin and 500–2500 ng/spot (r2 = 0.9984) for metformin. Validation of the developed method was performed as per the International Council for Harmonisation (ICH) guidelines. Stress testing of dapagliflozin and metformin was performed under acidic, alkaline, oxidative, photolytic and dry-heat degradation conditions. The chromatographic conditions successfully resolved dapagliflozin and metformin from their degradation products, formed under various stress conditions. From stress testing, dapagliflozin was found to be significantly degrading under acidic, alkaline, oxidative, photolytic and dry-heat degradation conditions, while metformin was found to be significantly degrading in acidic and alkaline degradation conditions and stable under oxidative, photolytic and dry-heat degradation conditions. Tablet dosage form of dapagliflozin and metformin was analyzed by the developed method.
相似文献A simple, rapid, and precise method is developed for the quantitative determination of lumefantrine (Lume) in active pharmaceutical ingredient (API). A chromatographic separation of Lume and its degradants were achieved with an X-Terra RP18, 250 × 4.6 mm, and 5 μ analytical column using buffer–acetonitrile (30:70 v/v). The buffer used in mobile phase contains 0.1 M sodium perchlorate monohydrate in double distilled water pH adjusted to 2.1 with trifluoroacetic acid. The instrumental settings are flow rate of 0.5 mL (L), column temperature at 35 °C, and detector wavelength of 235 nm using a photodiode array detector. Lume was exposed to thermal, photolytic, hydrolytic and oxidative stress conditions, and the stressed samples were analysed by the proposed method. Peak homogeneity data of Lume obtained by photodiode array detection, in the stressed sample chromatograms, demonstrated the specificity of the method for estimation in the presence of degradants. The described method shows excellent linearity over a range of 10–200 μg L−1 for Lume. The correlation coefficient is 1. The relative standard deviation of peak area for six measurements is always less than 2% between days. The proposed method was found to be suitable and accurate for quantitative determination and stability study of Lume in API.
相似文献A short ionic liquids-based monolithic cartridge was prepared and used as the selective extraction sorbent. Characteristic and evaluation are investigated by field emission scanning electron microscopy (FE-SEM), and a new approach was developed for the extraction and determination of β-sitosterol from Salicornia herbacea L. using the ionic liquids-based monolithic cartridge. Chromatographic analysis was conducted on a C18 column with UV detection at 210 nm, and an eluting solution consisting of acetonitrile–water (60/40, v/v) was used as the mobile phase at a flow rate of 0.8 mL min−1. The linearity was confirmed in the concentration range of 0.50–100.00 μg mL−1, with RSDs within 4.20%, and a recovery of β-sitosterol ranging from 97.20 to 102.93%. This method effectively removed the impurities without any tedious pretreatment, and it provided a fast, economic and effective way to assay trace drugs from natural plants.
相似文献The objective of the current study was the development and subsequent validation of a simple, sensitive, precise and stability-indicating reversed-phase HPLC method for the determination of ciprofloxacin HCl in pharmaceutical dosage forms in the presence of its potential impurities. The chromatographic separation of ciprofloxacin HCl and its related compounds was achieved on an Inertsil ODS3 column using UV detection. The optimized mobile phase consisted of phosphoric acid solution: acetonitril. The proposed method provided linear responses within the concentration range 250–750 μg mL−1 for ciprofloxacin HCl and 0.5–1.5 μg mL−1 for its related compounds. LOD and LOQ values for the active substance were 5.159 and 15.632 μg mL−1, respectively. Correlation coefficients (r) of the regression equations for the impurities were greater than 0.99 in all cases. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 1% in all instances. No interference from any components of pharmaceutical dosage forms or degradation products was observed.
相似文献A simple, sensitive, selective, precise and stability indicating high-performance thin-layer chromatographic method was developed for the determination of tamsulosin (TAM) in bulk and tablet formulation. Validation was carried out in compliance with International Conference on Harmonization guidelines. The method employed thin-layer chromatography aluminium plates pre-coated with silica gel 60F254 as the stationary phase and the mobile phase consisted of acetonitrile/methanol/dichloromethane (2.0: 1.0: 2.0, v/v/v). This solvent system was found to give compact spots for tamsulosin (R f = 0.27 ± 0.02). Densitometric analysis of TAM was carried out in the absorbance mode at 286 nm. Linear regression analysis showed good linearity (r 2 = 0.9993) with respect to peak area in the concentration range of 300–800 ng per band. The method was validated for precision, accuracy, ruggedness and recovery. Limits of detection and quantitation were 8.49 and 25.72 ng per band, respectively. TAM was subjected to acid and alkali hydrolysis, oxidation, photo degradation, dry heat and wet heat treatment. The drug underwent degradation under acidic, basic and photolytic conditions. The degraded products were well separated from the pure drug. Statistical analysis proved that the developed method, used for quantification of TAM as a bulk drug and present in pharmaceutical tablets, was reproducible and selective.
相似文献Zofenoprilat is an active metabolite of zofenopril, which is very unstable in plasma because of oxidative degradation of its thiol group. In this method, p-bromophenacyl bromide was used as derivatization reagent, immediately after plasma separation, to react with the free thiol group of zofenoprilat and form the derivative zofenoprilat-p-BPB. After acidification with 50% acetic acid, the derivatized plasma samples were extracted with methyl tert-butyl ether and separated on a C18 column with 40:60 (v/v) 10 mM ammonium acetate buffer solution containing 0.1% formic acid–acetonitrile as mobile phase. Calibration plots were linear over the concentration range 1–500 ng mL−1 for zofenopril and 2–1,800 ng mL−1 for zofenoprilat. The method was successfully used to study the bioavailability of zofenopril calcium capsules relative to that of zofenopril calcium tablets in healthy Chinese volunteers.
相似文献A sensitive and rapid liquid chromatographic method was successfully developed and validated for the determination of sibutramine hydrochloride in bulk and capsules. Sibutramine in the presence of its degradation products was analyzed using UV detection at 225 nm. Chromatography was performed on a reversed-phase C8 (150 × 4.0 mm I.D., 5 μm) analytical column under isocratic conditions. The mobile phase was composed of acetonitrile:water (aqueous phase containing 0.3% triethylamine and pH adjusted to 7.0) (75:25, v/v) at a flow-rate of 1.1 mL min−1. No chromatographic interference was found during the analysis. Light was the stress condition which most contributed to sibutramine degradation. The method showed a linear response (r > 0.999) from 30 to 90 μg mL−1. The mean recovery for capsules was 101.2%. Inter-day assays showed relative standard deviations of 0.42 and 1.62% for bulk and capsules, respectively. The developed method is able to separate sibutramine from its major degradation products and it may be used in the quality control of this active pharmaceutical ingredient in both bulk and capsules.
相似文献