首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
A simple, selective, rapid, precise and accurate reverse phase high pressure liquid chromatographic method has been developed for the simultaneous estimation of diclofenac sodium and rabeprazole sodium from pharmaceutical formulations. The method was developed using a HiQ SiL C18 (250 mm × 4.6 mm i.d.) column with a mobile phase consisting of methanol:water, (80:20 v/v), at a flow rate of 1.25 mL min?1. Detection was carried out at 284 nm. Indapamide was used as an internal standard. The developed method was validated for linearity, accuracy, precision, limit of detection and limit of quantitation. The proposed method can be used for the estimation of these drugs in combined dosage forms.  相似文献   

2.
Alberti  Agnes  Blazics  Balazs  Kery  Agnes 《Chromatographia》2008,67(1):107-111

A reversed-phase high-performance liquid chromatography method with UV detection was developed for determination of [(N-morpholine)methylene]daunorubicin hydrochloride (DD-M) during studies of its stability. In this LC method the following were used: an RP-column, the mobile phase—acetonitrile:methanol:solution A (9:1:10 v/v/v) [solution A contains 2.88 g of sodium laurilsulfate and 1.6 mL of phosphoric acid(V)] with a flow rate of 1.4 mol L−1 and quinine hydrochloride as an internal standard. The detection wavelength was 254 nm. The method was validated with regard to linearity, limit of detection, limit of quantitation, selectivity and precision. Hydrolysis of the DD-M catalyzed by hydrogen ions in hydrochloric acid and a spontaneous reaction of the DD-M degradation under the influence of the water in sodium hydroxide took place. The thermodynamic parameters of these reactions—energy, enthalpy and entropy of activation—were calculated. It was observed that a positive salt effect occurred in hydrochloric acid.

  相似文献   

3.
Ate&#;  Z.  &#;zden  T.  &#;zilhan  S.  Toptan  S. 《Chromatographia》2007,66(1):123-127

A simple method for the determination of carbamazepine and its active metabolite carbamazepine-10,11-epoxide by ultra performance liquid chromatography (UPLC) with ultraviolet absorbance detection (TUV) was developed. The method involves a two-step protein precipitation by liquid–liquid extraction. Phenytoin sodium was used as the internal standard. The separation was carried out on Acquity C18 column with acetonitrile:methanol:KH2PO4 buffer (adjusting pH to 4.6 with 85% o-phosphoric acid) (180/180/170, v/v/v) as the mobile phase at a flow rate of 0.4 mL min−1. Linear detection response was obtained for concentrations ranging from 50 to 5,000 ng mL−1. The limit of quantification (LOQ) was 50 ng mL−1. The method was validated successfully for the determination of carbamazepine and its active metabolite carbamazepine-10,11-epoxide, which can be applied through pharmacokinetics and bioequivalence studies.

  相似文献   

4.
《Analytical letters》2012,45(14):2180-2191
Abstract

A reliable and sensitive RP-HPLC method was developed and validated for the quantitative estimation of ceftriaxone sodium (CFTZ) in pure drug and pharmaceutical dosage forms. The separation of ceftriaxone sodium was achieved on a Waters XTerra RP-18 (5 µm, 250 × 4.6 mm i.d.) column using photodiode array detector at 240 nm. The mobile phase consisted of 0.1 M triethylammoniumacetate–acetonitrile (60:40 v/v) mixture delivered at a flow rate of 1.0 ml/min. Accuracy, evaluated by means of the spike recovery method, was excellent, with percent recovery in the range 99.5–102% with precision in the range 0.3–1.2%.  相似文献   

5.
Dogan-Topal  B.  Uslu  B.  Ozkan  S. A. 《Chromatographia》2007,66(1):97-101

This paper describes the validation of an isocratic high-performance liquid chromatographic method for the assay of valganciclovir in raw materials, tablets and human serum samples. Valganciclovir and fluvastatin (internal standard) were well separated using a reversed phase column and a mobile phase consisting of a mixture of acetonitrile:methanol:KH2PO4 (0.02 M) (40:20:40; v/v/v) (at pH 5.0). The mobile phase was pumped at 1.0 mL min−1 flow rate and valganciclovir was detected by diode-array detection at 255 nm. The retention times for valganciclovir and fluvastatin were 3.41 and 5.60 min, respectively. A linear response (r > 0.999) was observed in the range of 10–30,000 ng mL−1 in mobile phase and serum. The limit of detection and limit of quantification were found as 2.95 and 9.82 ng mL−1 in mobile phase and 1.73 and 5.77 ng mL−1 in human serum samples, respectively. Validation parameters as precision, accuracy, selectivity, reproducibility and system suitability tests were also determined. The method can be used for valganciclovir assay of tablets and human serum samples as the method separates valganciclovir from tablet excipients and endogenous substances.

  相似文献   

6.

An accurate, simple, reproducible, and sensitive liquid chromatographic method was developed and validated for the captopril determination in controlled release tablets. The analyses were performed at room temperature on a reversed-phase Phenomenex Luna C18 column (250 mm × 4.6 mm). The mobile phase was composed of water:methanol (45:55; v/v) pH 2.5, and it was eluted isocratically at a 1.0 mL min−1 flow rate. The method was validated in terms of specificity, linearity, quantification limit, detection limit, accuracy, precision and robustness. The response was linear in the range 0.3–1.5 mg mL−1 (r 2 = 0.9983). The relative standard deviation values for inter-and intra-day precision were 0.77% and 0.50%, respectively. Recoveries ranged between 97.7 and 99.1%. The method was successfully applied for the determination of captopril in the developed formulations.

  相似文献   

7.

A reversed phase LC method was developed and validated to analyze the in vitro release of AZT from microemulsions. A mobile phase of acetonitrile:water (15:85) was used. The method validation showed good selectivity and linearity (r = 0.9993) for sample concentrations ranging from 0.6 to 100.0 μg mL−1. The RSD values (0.7–4.3%) and percentage recovery (88.1–109.8%) were within acceptable limits. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.012 and 0.041 μg mL−1. Quantitative analysis of the values obtained in the drug release assay indicates that the microemulsions used promote sustained release of AZT, which follows a Fickian diffusion mechanism.

  相似文献   

8.
Zah&#;lka  L.  Matysov&#;  L.  &#;klubalov&#;  Z.  Klovrzov&#;  S.  Solich  P. 《Chromatographia》2013,76(21):1553-1558

A simple, selective and sensitive HPLC–UV method for quantification of propranolol hydrochloride and sodium benzoate in oral liquid preparations was developed and fully validated. Separation was performed by Supelco Discovery® C18 (25 cm × 4.6 mm, particles 5 μm) column. UV/VIS absorbance detector was set at wavelength 230 nm. Column oven was conditioned to 25 °C. Mobile phase was prepared by dissolving 1.6 g of sodium dodecyl sulphate and 0.31 g of tetrabutylammonium dihydrogen phosphate in 450 mL of ultrapure water; 1 mL of sulphuric acid (95–97 %) and 550 mL of acetonitrile were added. Sodium hydroxide solution (2.1 M) was used for adjusting pH to value 3.3 (±0.05). Retention times of sodium benzoate, propranolol hydrochloride and butylparaben (internal standard) were 2.2, 3.3 and 4.1 min, respectively. Newly developed method is suitable for simultaneous determination of propranolol hydrochloride and sodium benzoate in oral liquid preparations which are used for therapy of haemangiomas in paediatric patients. Method has been applied for stability testing of extemporaneous paediatric oral formulations containing propranolol hydrochloride.

  相似文献   

9.
Radhakrishnanand  P.  Subba Rao  D. V.  Himabindu  V. 《Chromatographia》2008,68(11):1059-1062

A new and accurate chiral liquid chromatographic method has been developed for the determination of enantiomeric purity of darifenacin [(S)-enantiomer] in bulk drugs and extended release tablets. Normal phase chromatographic separation was performed on an immobilized cellulose based chiral stationary phase (Chiralpak-IC) with n-hexane:ethanol:diethylamine (50:50:0.3, v/v/v) as mobile phase at a flow rate of 1.0 mL min−1. The elution time was ~15 min. The resolution (R s ) between the enantiomers was greater than four and interestingly the (R)-enantiomer was eluted prior to darifenacin in the developed method. The limit of detection (LOD) and limit of quantification (LOQ) for the (R)-enantiomer were 0.02 μg and 0.07 μg, respectively, for a 10 μL injection volume. The method was extensively validated in terms of linearity, precision and accuracy and satisfactory results were obtained. Robustness studies were also conducted. The sample solution stability of darifenacin was determined and the compound was found to be stable for a study period of 48 h.

  相似文献   

10.

A simple, sensitive and specific liquid chromatographic method with UV detection (228 nm) was developed for the simultaneous estimation of rosiglitazone and glimepride in human plasma. Rosiglitazone and glimepride were extracted from plasma using liquid–liquid extraction. Separation was achieved with an RP C18 Column using a mixture of phosphate buffer (50 mM) with octane sulfonic acid (10 mM), methanol and acetonitrile as a mobile phase (55:10:35, v/v). pH was adjusted to 7.0. Amlodipine was used as an internal standard (IS). LOD of the method was found to be 20 ng mL−1 for both drugs. Results were linear over the studied range 40.994–2007.556 ng mL−1 for rosiglitazone (r ≥ 0.99) and 41.066–2094.84 ng mL−1 for glimepride( r ≥ 0.99). The method was found to be simple, selective, precise and reproducible for the estimation of both drugs from spiked human plasma.

  相似文献   

11.
A liquid chromatographic method for the simultaneous determination of dextromethorphan hydrobromide, pyrilamine maleate and sodium benzoate in cough cold syrup has been developed. The method was based on replacing heptane sulfonate by sodium chloride as ion pairing agent. The addition of sodium chloride to the mobile phase has changed the retention behaviour of the basic drugs. The separation of these compounds was achieved in less than 8 min with an isocratic mobile phase consisting of acetonitrile/0.1 M dihydrogenphosphate buffer containing 0.1 M sodium chloride (29:71 v/v) at pH 2.5 and using a Kromasil C18 column. The analysis was performed at a flow rate of 1 mL min?1 and at a detection wavelength of 220 nm. The selectivity, linearity of calibration, accuracy, within and between days precision, limit of detection and quantification, recovery were examined as parts of the method validation. Calibration curves were linear in the range 1–140 μg mL?1 with a regression coefficient (R 2) better than 0.999. The results of the method repeatability (intra-day) and reproducibility (inter-day) were all less than 2% (= 6). The lowest detectable concentration of dextromethorphan hydrobromide and pyrilamine maleate varied between 0.10 and 0.12 μg mL?1. The proposed liquid chromatographic method was satisfactorily applied for the routine quality control of dextromethorphan hydrobromide, pyrilamine maleate and sodium benzoate in cough cold syrup formulations.  相似文献   

12.

This paper describes the validation of an isocratic LC method for the assay of linezolid in tablets. Validation parameters such as linearity, precision, accuracy, specificity, limit of detection, limit of quantitation and robustness were determined. LC was carried out by reversed phase technique on an RP-18 column with a mobile phase composed of 1% acetic acid:methanol:acetonitrile (50:25:25, v/v/v). Linezolid and your combination drug product were exposed to acid, base, oxidation, dry heat and photolytic stress conditions. A linear response (r > 0.9999) was observed in the range of 8.0–20.0 μg mL−1. The retention time of linezolid was 4.6 min. The method showed good recoveries and intra- and inter-day relative standard deviations were less than 1.0%. The LOD and LOQ were 0.21 and 0.63 μg mL−1, respectively. The developed LC method for determination of related substances and assay determination of linezolid can be used to evaluate the quality of regular production samples. It can also be used to test the stability samples of linezolid.

  相似文献   

13.
Radhakrishnanand  P.  Subba Rao  D. V.  Himabindu  V. 《Chromatographia》2009,69(3-4):369-373

A new and accurate chiral liquid chromatographic method has been developed for the separation of palonosetron hydrochloride (PALO) and its (R,R)-enantiomer in bulk drug samples with an elution time of about 20 min. The chromatographic separation was carried out by normal phase chromatography using an immobilized cellulose based chiral stationary phase (Chiralpak-IC) with a mobile phase composed of n-hexane:ethanol:1,4 dioxane:trifluoroacetic acid:diethylamine (65:30:5:0.3:0.3, v/v) pumped at a flow rate of 1.0 mL min−1. The resolution (R s ) between the enantiomers was found to be greater than 3.0 and interestingly the (R,R)-enantiomer was eluted prior to the (S,S)-enantiomer (PALO) in the developed method. Mobile phase additives, trifluoroacetic acid and diethylamine played a key role in achieving chromatographic resolution between the enantiomers and also in enhancing chromatographic efficiency. The limit of detection (LOD) and limit of quantification (LOQ) of the (R,R)-enantiomer were found to be 0.03 and 0.1 μg respectively for 10 μL injection volume. The developed method shows excellent linearity (r 2 > 0.999) over a range of LOQ to 0.3% for the (R,R)-enantiomer. The percentage recovery of the (R,R)-enantiomer in bulk drug samples ranged from 97.2 to 102.3 revealing good sensitivity of the developed method. Robustness studies were also carried out on the developed method.

  相似文献   

14.
&#;&#;leyen  E. A. &#;.  &#;zden  T.  &#;zilhan  S.  Toptan  S. 《Chromatographia》2007,66(1):109-113

A simple, rapid, sensitive and selective LC-MS method was developed and validated for quantification of fexofenadine in human plasma. The LC-MS system was operated under the positive electrospray ionisation mode (ESI). After liquid–liquid extraction, fexofenadine analysis was performed on a C18 column with a mobile phase of acetonitrile: 10 mM ammonium acetate: formic acid, 70:30:0.1 (v/v/v) at a flow rate of 1 mL min−1 by using loratadine as internal standard. The lower limit of quantitation was 3 ng mL−1 for fexofenadine. The assay precision ranged between 1.05 and 12.56% and accuracy ranged between 82.00 and 109.07%. The validated method was successfully used to analyze human plasma samples in bioequivalence studies.

  相似文献   

15.
Ate&#;  Z.  &#;zden  T.  &#;zilhan  S.  Eren  S. 《Chromatographia》2007,66(1):119-122

A simple, rapid, sensitive and selective method for the analysis of indapamide in human plasma, utilizing ultra performance liquid chromatography (UPLC), has been developed and validated to satisfy FDA guidelines for bioanalytical methods. The analyte and the internal standard, sulfamethazine, were isolated from plasma samples by liquid–liquid extraction with diethyl ether. Separation was performed with an Acquity C18 column. The gradient composition of mobile phase was composed of acetonitrile and sodium dihydrogenphosphate buffer (adjusted to pH 3.33 with 85% o-phosphoric acid) at a flow rate of 0.5 mL min−1. The assay exhibited a linear dynamic range of 1–100 ng mL−1 for indapamide in human plasma. The limit of quantification (LOQ) was 1 ng mL−1. The method was successfully applied to the pharmacokinetic and bioequivalence studies of indapamide formulations.

  相似文献   

16.

A selective and specific high-performance liquid chromatography method for the determination of daclatasvir enantiomers has been developed and validated. Various immobilized polysaccharide-based chiral stationary phases were used to define a separation strategy utilizing normal-phase and polar organic chromatography modes. Excellent resolution between daclatasvir and its enantiomer was achieved on amylose tris (3-chlorophenylcarbamate) stationary phase, namely CHIRALPAK ID-3, using binary gradient containing acetonitrile:diethylamine and methanol:diethylamine as the mobile phase. The flow rate of the mobile phases was maintained at 1.0 mL min−1 while the column oven temperature was maintained at 40 °C. The column effluent was monitored by UV detection at 315 nm. In comparison with isocratic method, the binary gradient method offered excellent peak shape and improved resolution between daclatasvir and its enantiomer while maintaining the specificity with diastereomers. The method was found to be precise, accurate, and linear (R 2 > 0.999). Limit of detection and limit of quantitation of the enantiomer were found to be 0.083 µg mL−1 as and 0.25 µg mL−1, respectively. Recovery of the enantiomer was found to be in the range of 90 to 112 %.

  相似文献   

17.

A simple, rapid, and precise method is developed for the quantitative determination of lumefantrine (Lume) in active pharmaceutical ingredient (API). A chromatographic separation of Lume and its degradants were achieved with an X-Terra RP18, 250 × 4.6 mm, and 5 μ analytical column using buffer–acetonitrile (30:70 v/v). The buffer used in mobile phase contains 0.1 M sodium perchlorate monohydrate in double distilled water pH adjusted to 2.1 with trifluoroacetic acid. The instrumental settings are flow rate of 0.5 mL (L), column temperature at 35 °C, and detector wavelength of 235 nm using a photodiode array detector. Lume was exposed to thermal, photolytic, hydrolytic and oxidative stress conditions, and the stressed samples were analysed by the proposed method. Peak homogeneity data of Lume obtained by photodiode array detection, in the stressed sample chromatograms, demonstrated the specificity of the method for estimation in the presence of degradants. The described method shows excellent linearity over a range of 10–200 μg L−1 for Lume. The correlation coefficient is 1. The relative standard deviation of peak area for six measurements is always less than 2% between days. The proposed method was found to be suitable and accurate for quantitative determination and stability study of Lume in API.

  相似文献   

18.
《Analytical letters》2012,45(1):151-162
Abstract

A novel developed spectrofluorimetric method for the determination of trazodone hydrochloride in the presence of sodium dodecyl sulfate (SDS) surfactant micelles was described. Under optimal conditions, there was a good linear relationship between fluorescence intensity and trazodone hydrochloride concentration in the range of 4.0×10?9 to 8.0×10?6 mol · l?1with the detection limit of 1.3×10?9 mol · l?1 (S/N=3). This method has been used to determine trazodone hydrochloride in biological fluids.  相似文献   

19.
Dincel  A.  Basci  N. E.  Atilla  H.  Bozkurt  A. 《Chromatographia》2007,66(1):51-56

A sensitive high performance liquid chromatographic method has been developed and validated for the determination of proparacaine in human aqueous humour. The procedure involved extraction of proparacaine from aqueous humour with cyclohexane. The separation was achieved using a Bondesil C8 (250 × 4.6 mm i.d., particle size 5 μm) analytical column with a mobile phase consisted of acetonitrile and sodium dihydrogen phosphate (pH 3.0, 20 mM) (30:70, v/v). Proparacaine and lidocaine (internal standard, IS) detection was performed by UV–Vis detector at 220 nm. The retention times for proparacaine and IS were 12.01 and 5.58 min, respectively. HPLC–UV–Vis method was linear in the range of 75–4,000 ng mL−1. The limit of detection (LOD) was 25 ng mL−1 and the limit of quantification (LOQ) of proparacaine was found to be 75 ng mL−1 (RSD ≤ 15%, = 6). In intra- and inter-day precision and accuracy analysis, the relative standard deviation was found to be in the range of 0.96 and 7.98%, the bias values were 0.64 and 3.33%. Recovery of proparacaine from human aqueous humour was 99.98% at 500 ng mL−1. Proparacaine solutions were stable at least 6 months at +4 and −20 °C. Proparacaine levels of aqueous humour in fifteen volunteers’ were in the range of 80.21 and 459.00 ng mL−1. According to system suitability tests and Shewhart’s quality control charts the proparacaine responses were in the acceptance ranges. Developed method was providing a sufficient quality at least over 3 months for determination of proparacaine in human aqueous humour.

  相似文献   

20.
A simple, sensitive, precise and accurate reversed phase liquid chromatographic method has been developed for the simultaneous estimation of atorvastatin (AT) calcium, ramipril (RA) and aspirin (AS) from capsule dosage form. The method was developed using a Phenomenex Luna C18 (250 mm, 4.6 mm i.d., 5 µm) column with a mobile phase consisting of 0.1%, orthophosphoric acid buffer:acetonitrile:methanol (45:50:5 v/v/v), pH 3.3, at a flow rate of 1 mL min?1. Detection was carried out with ultra-violet detection at 210 nm. The retention times were about 12.19, 2.35, and 3.95 min for AT calcium, RA and AS, respectively. The developed method was validated for linearity, accuracy, precision, limit of detection, limit of quantitation and robustness. The linearity ranges were 1–6 µg mL?1 for AT calcium, 0.5–3 µg mL?1 for RA and 7.5–45 µg mL?1 for AS with mean recoveries of 100.59 ± 0.68, 100.62 ± 0.83 and 100.49 ± 0.73% for AT calcium, RA and AS, respectively. Limit of detection obtained were 29.85 ng mL?1 for AT calcium, 4.71 ng mL?1 for RA and 85.13 ng mL?1 for AS. Impurity of salicylic acid was found in capsule dosage form at the retention time of about 4.84 min. The proposed method can be used for the estimation of these drugs in combined dosage forms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号