首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Monolithic materials have quickly become a well‐established stationary phase format in the field of capillary electrochromatography (CEC). Both the simplicity of their in situ preparation method and the large variety of readily available chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials. This review summarizes the contributions of numerous groups working in this rapidly growing area, with a focus on monolithic capillary columns prepared from synthetic polymers. Various approaches employed for the preparation of the monoliths are detailed, and where available, the material properties of the resulting monolithic capillary columns are shown. Their chromatographic performance is demonstrated by numerous separations of different analyte mixtures in variety of modes. Although detailed studies of the effect of polymer properties on the analytical performance of monolithic capillaries remain scarce at this early stage of their development, this review also discusses some important relationships such as the effect of pore size on the separation performance in more detail.  相似文献   

2.
This review summarizes the contributions to the rapidly growing area of monolithic columns based on both silica and synthetic polymers for capillary electrochromatography and chip electrochromatography, with a focus on those published during the year 2004. A wide variety of both modified approaches to the "old" monoliths and new monoliths have been reported despite the very short period of time covered. This demonstrates that monolithic stationary phases have become a well-established format in the field of electrochromatography. The simplicity of their preparation as well as the good control over their porous properties and surface chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials.  相似文献   

3.
Monolithic columns invented in chromatographic praxis almost 40 years ago gained nowadays a lot of popularity in separations by liquid chromatographic technique. At the same time, application of monolithic columns in gas chromatography is less common and only a single review published by Svec et al. [1] covers this field of research. Since that time a lot of new findings on application and properties of monolithic columns in gas chromatography have been published in the literature deserving consideration and discussion. This review considers preparation of monolithic columns for GC, an impact of preparation conditions on column performance, optimization of separation conditions for GC analysis on monolithic columns and other important aspects of preparation and usage of monolithic capillary columns in GC. A final part of the review discusses the modern trends and possible applications in the future of capillary monolithic columns in GC.  相似文献   

4.
溶胶-凝胶法制备毛细管硅胶整体柱的研究进展   总被引:3,自引:0,他引:3  
陈雅顺  贾丽 《分析化学》2008,36(6):853-859
毛细管硅胶整体柱作为一种新型的分离介质,在色谱领域显示出了强大的生命力。本评述介绍了溶胶-凝胶法制备毛细管硅胶整体柱的方法,重点分析了溶胶-凝胶法制备毛细管硅胶整体柱的影响因素,总结了近几年毛细管硅胶整体柱在高效液相色谱和电色谱中的应用。  相似文献   

5.
Monolithic columns for capillary electrochromatography are receiving quite remarkable attention. This review summarizes results excerpted from numerous papers concerning this rapidly growing area with a focus on monoliths prepared from synthetic polymers. Both the simplicity of the in situ preparation and the large number of readily available chemistries make the monolithic separation media a vital alternative to capillary columns packed with particulate materials. Therefore, they are now a well-established stationary phase format in the field of capillary electrochromatography. A wide variety of synthetic approaches as well as materials used for the preparation of the monolithic stationary phases are presented in detail. The analytical potential of these columns is demonstrated with separations involving various families of compounds and different chromatographic modes.  相似文献   

6.
Hilder EF  Svec F  Fréchet JM 《Electrophoresis》2002,23(22-23):3934-3953
This review summarizes the contributions of a number of groups working in the rapidly growing area of monolithic columns for capillary electrochromatography (CEC), with a focus on those prepared from synthetic polymers. Monoliths have quickly become a well-established stationary phase format in the field of CEC. The simplicity of their in situ preparation method as well as the good control over their porous properties and surface chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials. A wide variety of approaches as well as materials used for the preparation of the monolithic stationary phases are detailed. Their excellent chromatographic performance is demonstrated by numerous separations of different analytes.  相似文献   

7.
In recent years, the use of organic polymer monolithic capillary columns in separation science has gained popularity due to the fact that they are easy to fabricate and do not require retaining frits. These materials have been applied in different fields including foods, proteomics, and pharmaceuticals. The interest in food analysis still needs to develop in order to increase the sensitivity towards micro/nano‐scale food applications for food samples of < 5 μg (e.g., foodomics). In this regard, polymer monolithic capillary columns offer great separation capability in the food analytical separation science. We review the most important applications in food analysis using polymer monolithic capillary columns. In addition, several examples of the use of capillary separation methods combined with mass spectrometry detection in food analysis are summarized.  相似文献   

8.
Capillary liquid chromatography (cLC) has great potential for protein and peptide separation, with advantages of high efficiency, high resolution, low sample consumption, and high sensitivity when coupled with mass spectrometry. In recent years, monoliths have been widely used as the stationary phases for capillary columns, owing to easy preparation, high permeability, fast mass transfer, and low backpressure. This review summarizes recent advances (2007–2012) in monolithic columns for protein and peptide separation by cLC. After a brief introduction on the preparation of monolithic capillary columns, the emphasis of this review is focused on the recent application of such columns for protein and peptide separation by cLC. Furthermore, the challenges and potential hot points of monolithic capillary columns in the future are discussed.  相似文献   

9.
Wu M  Wu R  Zhang Z  Zou H 《Electrophoresis》2011,32(1):105-115
Organic-silica hybrid monolithic columns have drawn more and more attention due to the ease of preparation and good mechanical stability in recent years. Many synthetic approaches have been developed and a variety of hybrid monolithic capillary columns have been prepared. The sol-gel process is well recognized in the fabrication of hybrid monolithic columns, which can be mainly classified as one-step, acid/base two-step procedures. The new approaches such as the "one-pot" and nano-scaled inorganic-organic hybrid reagent of polyhedral oligomeric silsesquioxane used as a cross-linker have also emerged for the preparation of hybrid monolithic columns. The applications of the organic-silica hybrid monolithic capillary columns for capillary electrochromatography, micro high-performance liquid chromatography, solid-phase micro-extraction and enzymatic reactor etc. are included in this review.  相似文献   

10.
Eeltink S  Svec F 《Electrophoresis》2007,28(1-2):137-147
This review focuses on developments in the field of polymer-based monolithic columns for CEC published in the literature since the beginning of the year 2005. The possibility of in-situ preparation as well as easy control over their porous properties and surface chemistries clearly make monolithic separation media an attractive alternative to capillary columns packed with particles. Different variables such as polymerization conditions, morphology, and surface chemistry are shown to directly affect performance of monolithic capillary columns in terms of efficiency, analysis time, and retention.  相似文献   

11.
During the past decade, CEC has been one of the few novel achievements in the field of separation science attracting a wide interest. The technology progress permitted the realization of the long-sought idea to employ an electroosmotically driven flow through the columns improving the separations in terms of both resolution and efficiency. The early practical obstacles related to the use of conventional bead-packed columns have been solved by the introduction of continuous beds, also known as monoliths. Hitherto, various synthesis approaches have been successfully developed producing monolithic beds in situ in capillary columns, sharing similar physical structure built up of tiny particles (in the sub-microm range) that are covalently linked together and to the capillary wall. Parallel with the practical column technology studies, the theory of electrochromatography has been continuously developed, focusing on such basic issues as EOF characterization, separation efficiency, and peak dispersion effects. This review provides a short introduction to the theory of CEC with special attention to monolithic separation beds. The paper also summarizes the latest achievements in CEC and discusses the nomenclature, EOF characteristics, and some specific advantages of monolithic column technology.  相似文献   

12.
Monolithic columns for capillary electrochromatography (CEC) are receiving quite remarkable attention. Both the simplicity of the in situ preparation and the large number of readily available chemistries make the monolithic separation media a vital alternative to capillary columns packed with particulate materials. This review summarizes the current state-of-the-art in this rapidly growing area of CEC with a focus on monolithic capillary columns prepared from synthetic polymers. Recent achievements in column technologies for both high-performance liquid chromatography and capillary electrophoresis are used as the starting point to highlight the influence of these well established analytical methods on the development of monolithic capillary columns for CEC. The effects of individual variables on the separation properties of monolithic capillaries are discussed in detail. The analytical potential of these columns is demonstrated with separations involving various families of compounds in different chromatographic modes.  相似文献   

13.
毛细管电色谱中整体式高聚物毛细管柱技术的进展   总被引:7,自引:0,他引:7  
对近期毛细管电色谱(CEC)中利用高分子聚合反应制备整体式(monolithic)毛细管柱的技术,特别对各种不同类型的整体式毛细管的制备方法进行了详细介绍;对该类毛细管用于不同样品的分离情况进行了总结。  相似文献   

14.
Capillary electrochromatography, which combined the high selectivity of high‐performance liquid chromatography and the high separation efficiency of capillary electrophoresis, is an attractive separation tool. In this review, the developments on monolithic and open tubular capillary electrochromatography during 2017 to August 2019 are summarized. Considering the development of novel stationary phases is the most active research field in capillary electrochromatography, monolithic capillary electrochromatography is classified according to the polymer‐based and hybrid monolithic columns, while open‐tubular capillary electrochromatography is categorized by cyclodextrin, silica, polymer, nanomaterials, microporous materials, and biomaterials‐based open tubular columns.  相似文献   

15.
整体柱离子色谱的研究进展   总被引:1,自引:0,他引:1  
陈倩  于泓 《分析测试学报》2011,30(6):705-712
该文介绍了离子色谱的分类,整体柱的分类、制备及特点,并以此为依据归纳总结了常规整体柱在离子色谱中的应用和毛细管整体柱在毛细管离子色谱中的应用,其中包括硅胶基质整体柱和聚合物基质整体柱,评述并展望了整体柱离子色谱的发展前景.  相似文献   

16.
In recent years, continuous separation media have attracted considerable attention because of the advantages they offer over packed columns. This research resulted in two useful monolithic material types, the first based on modified silica gel and the second on organic polymers. This work attempts to review advances in the development, characterization, and applications of monolithic columns based on synthetic polymers in capillary chromatography, with the main focus on monolithic beds prepared from methacrylate-ester based monomers. The polymerization conditions used in the production of polymethacrylate monolithic capillary columns are surveyed, with attention being paid to the concentrations of monomers, porogen solvents, and polymerization initiators as the system variables used to control the porous and hydrodynamic properties of the monolithic media. The simplicity of their preparation as well as the possibilities of controlling of their porous properties and surface chemistries are the main benefits of the polymer monolithic capillary columns in comparison to capillary columns packed with particulate materials. The application areas considered in this review concern mainly separations in reversed-phase chromatography, ion-exchange chromatography, hydrophobic and hydrophilic interaction modes; enzyme immobilization and sample preparation in the capillary chromatography format are also addressed.  相似文献   

17.
Bedair M  El Rassi Z 《Electrophoresis》2004,25(23-24):4110-4119
This review article summarizes the advances made over the last two years in polymeric monoliths for capillary electrochromatography (CEC). It covers the scientific literature in the period extending form the second half of 2002 until the end of first half of 2004. Currently, there is an increasing interest in monolithic stationary phases in CEC as an alternative to particulate packed capillary columns due in major part to the simplicity of the in situ preparation of monolithic stationary phases and the availability of a wide chemistry for surface ligands, which allow for tailoring the chromatographic sorbent needed for solving a given separation problem(s). The various approaches, formats, and chemistries used for the preparation of monolithic stationary phases are described.  相似文献   

18.
Kang J  Wistuba D  Schurig V 《Electrophoresis》2002,23(22-23):4005-4021
Recent progress in enantiomeric separations by capillary electrochromatography (CEC) is reviewed. The development of simple and robust CEC column technologies plays an important role for popularization of CEC. During the last several years, various approaches for the preparation of enantioselective columns have been reported. Currently, the monolithic column technology (continuous beds) represents the most advanced approach for the preparation of CEC columns. The development of new chiral stationary phase used for CEC is another important issue in this field. Fundamental investigations on electrochromatographic behaviors of various CSPs are necessary in order to understand the separation mechanism and thus improve the separation performance. Some chiral stationary phases performed better under nonaqueous CEC conditions than reversed-phase conditions. Coupling CEC with mass spectrometry (MS) provides a powerful tool for enantiomeric separation. Finally, some applications of enantiomeric separation by CEC are summarized.  相似文献   

19.
Chen Z  Ozawa H  Uchiyama K  Hobo T 《Electrophoresis》2003,24(15):2550-2558
We describe beta- and gamma-cyclodextrins (beta- and gamma-CD)-modified monolithic columns prepared by sol-gel process and chemical modifications. The monolithic silica column was fabricated inside a fused-silica capillary with 100 microm inner diameter by sol-gel process. The monolithic silica matrix was chemically modified chiral selectors of beta- or gamma-CDs with a spacer of 3-glycidoxypropyltrimethoxysilane by on-column reactions. Gamma-CD-modified monolithic column has successfully been applied for the separation of dansyl amino acid enantiomers. Beta-CD-modified monolithic column has been used for the separation of the positional isomers of o-, m-, and p-cresols and the enantioseparation of racemates of benzoin and several dansyl amino acids by capillary electrochromatography, respectively. For the separation of neutral positional isomers, a positive electric field was applied. However, for the separation of negatively charged analytes, a negative electric field was applied at the inlet of column. The separation efficiency of 5.0 x 10(4) theoretical plates/m for dansyl-L-threonine was obtained at electric field strength of -300 V/cm in the mobile phase of 50 mM 2-(N-morpholino)ethanesulfonic acid (MES)-Tris/methanol (70/30) buffer at pH 7.0. L-enantiomers were eluted as the first peak. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pores.  相似文献   

20.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号