首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
In this paper, the electrogenerated chemiluminescence (ECL) from thiol-capped CdTe quantum dots (QDs) was reported. The ECL emission was occurred at −1.1 V and reached a maximum value at −2.4 V when the potential was cycled between 0.0 and −2.5 V. The reduced species of CdTe QDs could react with the coreactants to produce the ECL emission. The CdTe QD concentration (6.64 × 10−7 mol L−1) of ECL is lower than that (1.0 × 10−3 mol L−1) of chemiluminescence (CL). Based on the enhancement of light emission from thiol-capped CdTe QDs by H2O2 in the negative electrode potential, a novel method for the determination of H2O2 was developed. The light intensity was linearly proportional to the concentration of H2O2 between 2.0 × 10−7 and 1.0 × 10−5 mol L−1 with a detection limit of 6.0 × 10−8 mol L−1. Compared with most of previous reports, the proposed method has higher sensitivity for the determination of H2O2. In addition, the ECL spectrum of thiol-capped CdTe QDs exhibited a peak at around 620 nm, which was substantially red shifted from the photoluminescence (PL) spectrum, suggesting the surface states play an important role in this ECL process.  相似文献   

2.
Lijuan Hua  Xueji Zhang 《Talanta》2009,77(5):1654-4893
Water-soluble CdTe quantum dots (QDs) with five sizes (2.25, 2.50, 2.77, 3.12, and 3.26 nm) were synthesized with the hydrothermal method. The electrochemiluminescence (ECL) of CdTe QDs was investigated in detail in air-saturated solution without adding foreign oxidant. It was found that the ECL of CdTe QDs displayed a size-dependent property. With the increasing in the particle size of the CdTe QDs, the ECL intensity was gradually increased, in addition, both ECL peak potentials and ECL onset potentials of CdTe QDs were shifted positively. Influences of some factors on the ECL intensity were investigated. Under the optimal conditions, the ECL intensity had a linear relationship with the concentration of l-cysteine (l-Cys) in the range from 1.3 × 10−6 to 3.5 × 10−5 mol L−1 (R2 0.996) with a detection limit of 8.7 × 10−7 mol L−1 (S/N = 3). The proposed method was applied to the determination of l-Cys in real samples with satisfactory results. Compared with previous reports, it has better selectivity for the determination of l-Cys.  相似文献   

3.
In this study, an electrogenerated chemiluminescence (ECL) sensing platform for carbofuran detection was constructed based on ECL energy transfer (ECRET) and carbon dot (C-dot)-tagged aptamers as the recognition element. Fullerene (C60)-loaded gold nanoparticles (C60-Au) were used as the energy donor, modified on a glassy carbon electrode. C-dot-tagged DNA aptamers were used as the receptor, and ECRET then occurred between C60-Au and C-dots. After accepting the energy, the C-dots acted as a signal indicator and showed decreased signal intensity in the presence of targets, which competitively bound to DNA aptamers and blocked energy transfer. Using this robust, straight-forward strategy, the sensor showed a linear ECL response to carbofuran at concentrations from 2.0 × 10−11 mol L−1 to 8.0 × 10−9 mol L−1. The detection limit of this assay was shown to be 8.8 × 10−13 mol L−1. Thus, the sensing approach described in this study could be adapted for use in the detection of various pesticide residue targets.  相似文献   

4.
Xiaofei Hu  Wenrui Jin 《Talanta》2010,80(5):1737-18828
A new electrochemiluminescence (ECL) DNA assay is developed using quantum dots (QDs) as DNA labels. When nanoporous gold leaf (NPGL) electrodes are used, sensitivity of the ECL assay is remarkably increased due to ultra-thin nanopores. In this assay, target DNA (t-DNA) is hybridized with capture DNA (c-DNA) bound on the NPGL electrode, which is fabricated by conjugating amino-modified c-DNA to thioglycolic acid (TGA) modified at the activated NPGL electrode. Following that, amino-modified probe DNA is hybridized with the t-DNA, yielding sandwich hybrids on the NPGL electrode. Then, mercaptopropionic acid-capped CdTe QDs are labeled to the amino group end of the sandwich hybrids. Finally, in the presence of S2O82− as coreactant, ECL emission of the QD-labeled DNA hybrids on the NPGL electrode is measured by scanning the potential from 0 to −2 V to record the curve of ECL intensity versus potential. The maximum ECL intensity (Im,ECL) on the curve is proportional to t-DNA concentration with a linear range of 5 × 10−15 to 1 × 10−11 mol/L. The ECL DNA assay can be used to determine DNA corresponding to mRNA in cell extracts in this study.  相似文献   

5.
A new electrochemical biosensor was developed to demonstrate the effect of Acridine Orange (AO) on DNA damage. Then, the biosensor was used to check the inhibitors effect of three flavonols antioxidants (myricetin, fisetin and kaempferol) on DNA damage. Acridine Orange (AO) was used as a damaging agent because it shows a high affinity to nucleic acid and stretch of the double helical structure of DNA. Decreasing on the oxidation signals of adenine and guanine (in the DNA) in the presence of AO were used as probes to study the antioxidants power, using DNA-modified screen printed graphene electrode (DNA/SPGE). The results of our study showed that the DNA-biosensor could be suitable biosensor to investigate the inhibitors ability of the flavonols antioxidants on the DNA damage. The linear dependency was detected in the two regions in the ranges of 1.0–15.0 and 15.0–500.0 pmol L−1. The detection limit was found 0.5 pmol L−1 and 0.6 pmol L−1 for guanine and adenine, respectively. To confirm the electrochemical results, Uv–Vis and fluorescence spectroscopic methods were used too. Finally molecular dynamic (MD) simulation was performed on the structure of DNA in a water box to study any interaction between the antioxidant, AO and DNA.  相似文献   

6.
The present work describes the development of an amperometric sensor based on hemin immobilized on a titanium oxide modified silica toward detection of artemisinin (ARN) in neutral medium at an applied potential of −0.5 V vs. Ag/AgCl. The sensor presented its best performance in 0.1 mol L−1 phosphate buffer solution, at pH 7.0. After optimizing the operational conditions, the sensor provided a linear response range for ARN reduction from 50 nmol L−1 to 1000 nmol L−1 with a sensitivity, detection and quantification limits of 24.66 A L mol−1, 15 nmol L−1 and 52 nmol L−1, respectively. The proposed sensor showed a stable response for at least 80 successive determinations. The repeatability of the measurements with the sensor and the preparation of a series of electrodes, evaluated in terms of relative standard deviation, were 4.1% and 5.0%, respectively, for n = 10. The developed sensor was applied for the determination of ARN in the crude extracts of A. vulgaris L and the average recovery for these samples is 101.4 (± 3.1)%.  相似文献   

7.
In this paper, a novel colorimetric biosensor for Hg2+ and DNA molecules is presented based on Hg2+ stimulated oxidase-like activity of bovine serum albumin protected silver clusters (BSA-Ag NCs). Under mild conditions, Hg2+ activated BSA-Ag NCs to show high catalytic activity toward the oxidation of 3,3′,5, 5′-tetramethylbenzidine (TMB) using ambient dissolved oxygen as an oxidant. The oxidase-like activity of BSA-Ag NCs was “switched-on” selectively in the presence of Hg2+, which permitted a novel and facile colorimetric sensor for Hg2+. As low as 25 nmol L−1 Hg2+ could be detected with a linear range from 80 nmol L−1 to 50 mmol L−1. In addition, the sensing strategy was also employed to detect DNA molecules. Hg2+ is known to bind very strongly and specifically with two DNA thymine bases (T) to form thymine–Hg2+–thymine (T–Hg2+–T) base pairs. The hairpin-structure was disrupted and Hg2+ ions were released after hybridization with the DNA target. By coupling the Hg2+ switched-on the oxidase-mimicking activity of BSA-Ag NCs, we developed a novel label-free strategy for facile and fast colorimetric detection of DNA molecules. More important, target DNA can be detected as low as 10 nmol L−1 with a linear range from 30 to 225 nmol L−1. Compared with other methods, this method presents several advantages such as the independence of hydrogen peroxide, high sensitivity and good selectivity, avoiding any modification or immobilization of DNA, which holds a great potential of metal NCs for clinical application in biosensing and biotechnology.  相似文献   

8.
Here for the first time, we present a novel electrochemiluminescence (ECL) sensor based on graphitic carbon nitride/graphene oxide (g-C3N4/GO) hybrid for the ultrasensitive detection of Cu2+, which is a common pollutant in environmental system. The g-C3N4/GO shows stable ECL signal in the presence of the self-produced coreactant from oxygen reduction, and the ECL signal could be effectively quenched by Cu2+, the possible ECL detection mechanism has been proposed in detail. GO can not only significantly enhance the cathodic ECL signal of g-C3N4 (∼3.8 times), but also serve as immobilization platform for g-C3N4. After optimization of experimental conditions, the proposed protocol can offer an ultrasensitive, highly selective and recyclable method for the detection of Cu2+ with a low detection limit of 1.0 × 10−11 M and a wide linear range from 1.0 × 10−11 to 1.0 × 10−7 M. Moreover, the practicability of the ECL sensor in real wastewater samples is also tested, showing that the proposed ECL sensor could be a promising alternative method for the emergency and routine monitoring of Cu2+ in real sample.  相似文献   

9.
It was found that tripropylamine (TPA) could be used as a coreactant to initiate the electrochemiluminescence (ECL) of acridinium NHS ester (AE NHS) labels attached to DNA. The radicals generated in the electro-oxidation process of TPA reacted with AE NHS to form the excited N-methylacridone, giving rise to light emission. The AE/TPA ECL system was for the first time used as the detection system for developing an ECL-based DNA sensor. In the protocol, streptavidin-modified gold nanoparticles were firstly immobilized onto a thiol-treated gold electrode. The streptavidin could specifically interact with the biontinylated capture DNA. Afterwards, the target DNA and the AE-labeled report DNA were conjugated onto the electrode step by step due to the hybridization reactions, and a sandwich-type sensor was fabricated. The ECL signals of the sensor were obtained under pulse potential condition in alkaline solution containing 50.0 mmol L−1 TPA. Under optimized experimental conditions, the linear range of the DNA sensor for the determination of the target DNA was from 5.0 × 10−15 to 5.0 × 10−12 mol L−1. The detection limit (S/N = 3) was 3.0 × 10−15 mol L−1. Moreover, the sensor could specifically recognize the target DNA against one base-pair mismatched sequences, two base-pair mismatched sequences, and the noncomplementary sequences. It is of great application potential in clinic analysis.  相似文献   

10.
Wei J  He JB  Cao SQ  Zhu YW  Wang Y  Hang GP 《Talanta》2010,83(1):190-196
A nonionic poly(2-amino-5-mercapto-thiadiazole) film was electrodeposited on a solid carbon paste electrode via a potential scanning procedure, and used for amperometric sensing of ascorbic acid (AA), dopamine (DA) and serotonin (ST). The highly electrocatalytic activity of the sensor to the three analytes was demonstrated from the sensitive and well separated voltammetric signals. The polymer film did not show significant accumulation effect on all the three species, reducing the fouling and deactivation of the electrode surface as well as the mutual interference among the analytes. The sensor achieved amperometric sensitivities of 1.92 nA (nmol L−1)−1 cm−2 to AA in the linear range of 0.025-1.95 μmol L−1, 3.76 nA (nmol L−1)−1 cm−2 to DA and 7.00 nA (nmol L−1)−1 cm−2 to ST both in the linear range of 0.02-1.56 μmol L−1. The lowest detection limits were found to be 1.5, 0.7 and 0.4 nmol L−1 for AA, DA and ST, respectively. This sensor was successfully employed for the successive determination of AA, DA and ST in pharmaceutical samples. The good antifouling property and reproducibility of the proposed sensor can be attributed to the nonionic polymer film without electrostatic attraction to the ionized species in the solutions.  相似文献   

11.
In this study, thioglycolic acid capped-CdTe quantum dots (QDs) were modified by polyethylenimine (PEI), and then combined with fluorescein isothiocyanate (FITC) to fabricate FITC–CdTe conjugates. The self-assembly of FITC, CdTe and PEI was ascribed to electrostatic interactions in aqueous solution. The resulting conjugates were developed toward two routes. In route one, ratiometric photoluminescence (PL) intensity of conjugates (IFITC/IQDs) was almost linear toward pH from 5.3 to 8.7, and a ratiometric PL sensor of pH was favorable obtained. In route two, firstly added S2− induced remarkable quenching of QDs PL peak (at the “OFF” state), which was restored due to following addition of Cd2+ (at the “ON” state). In the conjugates, successive introduction of S2− and Cd2+ hardly influenced on FITC PL peaks. According to this PL “OFF-ON” mode, a ratiometric PL method for the detection of Cd2+ was achieved. Experimental results confirmed that the IFITC/IQDs exhibited near linear proportion toward Cd2+ concentration in the range from 0.1 to 15 μM, and the limit of detection was 12 nM. Interferential experiments adequately testified that the proposed sensors of pH and Cd2+ were practicable in real samples and complex systems. In comparison with conventional analytical techniques, the ratiometric PL method was simple, rapid, economic and highly selective.  相似文献   

12.
Herein, high quality DNA-CuInS2 QDs are facilely synthesized through a one-pot hydrothermal method with fluorescence quantum yield as high as 23.4%, and the strongly fluorescent DNA-CuInS2 QDs have been utilized as a novel fluorescent biosensor for label-free and ultrasensitive detection of anthrax lethal factor DNA. L-Cysteine (L-Cys) and a specific-sequence DNA are used as co-ligands to stabilize the CuInS2 QDs. The specific-sequence DNA consists of two domains: phosphorothiolates domain (sulfur-containing variants of the usual phosphodiester backbone) controls the nanocrystal passivation and serves as a ligand, and the functional domain (non-phosphorothioates) controls the biorecognition. The as-prepared DNA-CuInS2 QDs have high stability, good water-solubility and low toxicity. Under the optimized conditions, a linear correlation was established between the fluorescence intensity ratio I/I0 (I0 is the original fluorescence intensity of DNA-CuInS2 QDs, and I is the fluorescence intensity of DNA-CuInS2 QDs/GO with the addition of various concentrations of anthrax lethal factor DNA) and the concentration of anthrax lethal factor DNA in the range of 0.029–0.733 nmol L−1 with a detection limit of 0.013 nmol L−1. The proposed method has been successfully applied to the determination of anthrax lethal factor DNA sequence in human serum samples with satisfactory results. Because of low toxicity and fine biocompatibility, DNA-CuInS2 QDs also hold potential applications in bioimaging.  相似文献   

13.
14.
15.
Haghighi B  Bozorgzadeh S 《Talanta》2011,85(4):2189-2193
ZnO nanoparticles (nanoZnO) were decorated on multiwalled carbon nanotubes (MWCNTs) and then the prepared nano-hybrids, nanoZnO-MWCNTs, were immobilized on the surface of a glassy carbon electrode (GCE) to fabricate nanoZnO-MWCNTs modified GCE. The prepared electrode, GCE/nanoZnO-MWCNTs, showed excellent electrocatalytic activity towards luminol electrochemiluminescence (ECL) reaction. The electrode was then further modified with lactate oxidase and Nafion to fabricate a highly sensitive ECL lactate biosensor. Two linear dynamic ranges of 0.01-10 μmol L−1 and 10-200 μmol L−1 were obtained for lactate with the correlation coefficient better than 0.9996. The detection limit (S/N = 3) was 4 nmol L−1 lactate. The relative standard deviation for repetitive measurements (n = 6) of 10 μmol L−1 lactate was 1.5%. The fabrication reproducibility for five biosensors prepared and used in different days was 7.4%. The proposed ECL lactate biosensor was used for determination of lactate in human blood plasma samples with satisfactory results.  相似文献   

16.
A label-free and enzyme-free sensitive fluorescent detection of human immunodeficiency virus (HIV) deoxyribonucleic acid (DNA) based on isothermal hybridization chain reaction (HCR) was developed. A G-quadruplex sequence which was incorporated into one of the two hairpin probes was inactive in the absence of target DNA. However, at the presence of target DNA numerous G-quadruplexes along DNA nanowires were self-assembled through HCR. Using N-methyl mesoporphyrin IX (NMM) as the fluorophore, a “turn-on” fluorescent response would be achieved and detected as low as 0.5 nmol L−1 of HIV DNA. This proposed method was applied to detect HIV DNA in biologic samples with satisfactory results.  相似文献   

17.
This work reported for the first time the use of flow injection electrochemiluminescence (FI-ECL) sensor for the determination of durabolin in an aqueous system based on CdTe quantum dot (QD) films. Aqueous CdTe colloidal solutions were prepared using thioglycolic acid as a capping agent. Zetasizer Nano ZS (Malvern, UK) was employed to characterize the size of CdTe QDs. The UV–vis and photoluminescence spectra of samples were systematically characterized. Indium tin oxide (ITO) slide glass was modified with CdTe QDs by layer-by-layer self-assembly. CdTe QD films were packed into a homemade cell and used as a recognizer of the FI-ECL sensor to determine durabolin. The intensive anodic ECL emission was obtained at a starting potential of +1.3 V (vs. Ag/AgCl) in a carbonate bicarbonate buffer solution with a pH of 9.93 at an ITO electrode. The ECL intensity was correlated linearly with the concentration of durabolin over the range of 1.0 × 10−8–1.0 × 10−5 g mL−1, and the detection limit was 2.5 × 10−9 g mL−1. The relative standard deviation for the determination of 1.0 × 10−6 g mL−1 durabolin was 1.04% (n = 11). This simple and sensitive sensor revealed good reproducibility for ECL analysis. As a result, the new FI-ECL sensor had been successfully applied to the determination of durabolin in food samples. This strategy could be easily realized and opened new avenues for the applications of QDs in ECL biosensing.  相似文献   

18.
In the present paper we describe a robust and simple method to measure dissolved iron (DFe) concentrations in seawater down to <0.1 nmol L−1 level, by isotope dilution multiple collector inductively coupled plasma mass spectrometry (ID-MC-ICP-MS) using a 54Fe spike and measuring the 57Fe/54Fe ratio. The method provides for a pre-concentration step (100:1) by micro-columns filled with the resin NTA Superflow of 50 mL seawater samples acidified to pH 1.9. NTA Superflow is demonstrated to quantitatively extract Fe from acidified seawater samples at this pH. Blanks are kept low (grand mean 0.045 ± 0.020 nmol L−1, n = 21, 3× S.D. limit of detection per session 0.020–0.069 nmol L−1 range), as no buffer is required to adjust the sample pH for optimal extraction, and no other reagents are needed than ultrapure nitric acid, 12 mM H2O2, and acidified (pH 1.9) ultra-high purity (UHP) water. We measured SAFe (sampling and analysis of Fe) reference seawater samples Surface-1 (0.097 ± 0.043 nmol L−1) and Deep-2 (0.91 ± 0.17 nmol L−1) and obtained results that were in excellent agreement with their DFe consensus values: 0.118 ± 0.028 nmol L−1 (n = 7) for Surface-1 and 0.932 ± 0.059 nmol L−1 (n = 9) for Deep-2. We also present a vertical DFe profile from the western Weddell Sea collected during the Ice Station Polarstern (ISPOL) ice drift experiment (ANT XXII-2, RV Polarstern) in November 2004–January 2005. The profile shows near-surface DFe concentrations of 0.6 nmol L−1 and bottom water enrichment up to 23 nmol L−1 DFe.  相似文献   

19.
A novel sequential injection method for the determination of nitrite at nanomolar level in seawater samples has been developed. The pink azo compound was formed based on the Griess reaction and quantitatively adsorbed onto a Sep-Pak C18 cartridge. The enriched azo compound was rinsed with water and ethanol (28%, v/v) in turn, and then eluted with an eluent containing 26.6% (v/v) ethanol and 0.108 mol L−1 H2SO4. Finally the azo compound was measured using a spectrophotometer at 543 nm. Under the optimized conditions, the linear calibration ranges were 0.71–42.9 nmol L−1 for a 150-mL sample and 35.7–429 nmol L−1 for a 15-mL sample. The relative standard deviation of 8 measurements was 1.44% for 14.3 nmol L−1 nitrite. For the 150 mL sample, the detection limit was estimated to be 0.1 nmol L−1. The throughput of the method was about 4 samples per hour. The proposed method has been successfully applied to the in-field determination of nanomolar concentrations of nitrite in seawater.  相似文献   

20.
In this paper, the comparison of two kinds of electrochemically reduced graphene oxide (ERGNO) and zirconia composites, obtained by one-step (ZrO2–ERGNO) and stepwise (ZrO2/ERGNO) electrodeposition for DNA sensing, is systematically studied. The resulting composites were characterized by scanning electron microscopy, cyclic voltammetry, and differential pulse voltammetry. The results indicated that the ZrO2–ERGNO presented fine globular nanostructure. However, ZrO2/ERGNO presented agglomerate massive microstructure due to the absence of the oxygen-containing groups of graphene oxide, confirming the oxygen-containing groups provided a better affinity for the deposition of ZrO2. Due to the strong binding of the phosphate groups of DNA with the zirconia film, DNA probes were attached on the ZrO2-based composites. ZrO2–ERGNO/Au owning fine nanostructure presented larger surface area than microstructured ZrO2/ERGNO/Au. Moreover, compared with microstructured ZrO2/ERGNO, the nanostructured ZrO2–ERGNO provided more accessible space for immobilized DNA probe hybridization with target sequence, which consequently resulted in higher hybridization efficiency. Therefore, the ZrO2–ERGNO was chosen for fabricating DNA sensor with a limit of detection 1.21 × 10−14 mol L−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号