首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Yuling Hu 《Talanta》2010,80(5):2099-46
The combination of molecular imprinting and solid-phase microextraction (SPME) technique provides a powerful sample preparation tool in terms of selectivity, simplicity, and flexibility. This paper reports a novel molecularly imprinted polymer (MIP) coated SPME fiber with 17β-estradiol as template by improved multiple co-polymerization method. The obtained fiber exhibits excellent characteristics such as high porosity, good thermal and chemical stability. Extraction performance shows that the MIP-coated fiber has stronger affinity to the template molecule as compared with the commercial SPME fibers and the control polymer-coated fiber without addition of template. Owing to the shape and structural compatibility, the obtained fiber also demonstrated specific selectivity to the structural related compounds of 17β-estradiol, such as estriol, estrone and 17α-ethynylestradiol, and thus can be applied to simultaneous determination of these estrogens from complex samples coupled with high performance liquid chromatography. The variables that influence extraction were investigated. The MIP-coated fiber demonstrated its efficiency for extraction of estrogens in fishery samples. The detection limits were in the range of 0.98-2.39 μg L−1, and the recoveries were 80.0-83.6% and 85.0-94.1% for fish and shrimp tissue samples, respectively.  相似文献   

2.
以苯基官能化MCM-41介孔复合体作为固相微萃取(SPME)的吸附涂层, 与高效液相色谱(HPLC)联用测定了不同水样中邻苯二甲酸二甲酯(DMP)、邻苯二甲酸二乙酯(DEP)、邻苯二甲酸二丁酯(DBP)和邻苯二甲酸二辛酯(DOP)的含量, 对SPME的吸附和解吸时间、温度、搅拌速度进行了优化, 线性范围分别为1.19×10-4~119 μg/L、 1.12×10-4~112 μg/L、 1.05×10-4~105 μg/L和9.80×10-5~98 μg/L, 检出限依次为0.030、 0.027、 0.029和0.022 ng/L. 使用该方法测定了多种水样中邻苯二羧酸酯类化合物.  相似文献   

3.
Ma X  Li Q  Yuan D 《Talanta》2011,85(4):2212-2217
The commercial solid phase microextraction (SPME) fibers are not stable enough in organic solvent and tend to swell and strip off from the silica fiber in the high performance liquid chromatography (HPLC) mobile phase, and therefore the application of SPME coupled online with HPLC is limited. In this study, an SPME fiber coated with single walled carbon nanotubes (SWCNTs), prepared by means of electrophoretic deposition, was coupled on line to HPLC for the determination of four endocrine-disrupting compounds, i.e. bisphenol A (BPA), estrone (E1), 17α-ethynylestradiol (EE2) and octylphenol (OP), in aqueous samples. The results showed that the SWCNTs coating on the prepared fiber did not swell and strip off from the platinum fiber throughout the experiment, thus indicating a high resistance to the HPLC mobile phase, the mixture of water and acetonitrile. The SWCNTs fiber had similar (for OP) or higher (for BPA, EE2 and E1) extraction efficiencies than the commonly used polyacrylate fiber, and had a lifetime of more than 120 operation times. Under the optimized conditions, the linearity of the proposed method was 1.0-30.0 μg/L for BPA and OP and 3.0-90.0 μg/L for E1 and EE2. The limits of detection (LODs; S/N = 3) and limits of quantification (LOQs; S/N = 10) of the method were 0.32-0.52 μg/L and 1.06-1.72 μg/L, respectively. Repeatability for one fiber (n = 3) was in the range of 1.3-7.1% and fiber-to-fiber reproducibility (n = 3) was in the range of 1.6-8.4%. The proposed method was successfully applied for the analysis of spiked tap water and seawater samples with recoveries from 81.8 to 97.3%.  相似文献   

4.
应用可忽略耗损固相微萃取与高效液相色谱联用技术测定了环境水样中双酚A的自由溶解态浓度。为了获得高的灵敏度并减小环境因素(如温度和搅拌等)的影响,采用商品化固相微萃取纤维CW/TPR进行平衡采样。在环境水样常见pH(5~8)、缓冲容量(5~200mmol/L)和盐度(0~500mmol/L)条件下,4h可以达到萃取平衡。100mL样品足以避免样品耗损。以配制在250mmol/L NaCl和125mmol/L磷酸盐溶液(pH6.4)中的双酚A标准溶液进行校准,可以将缓冲液(0~200mmol/L)、盐度(0~500mmol/L)和pH(5.7~8.5)的影响控制在15%偏差范围以内。如需更准确的测定,也可以对样品pH值的影响加以校正。pH为6.4时,方法的线性范围为0.1~250μg/L,检出限为0.03μg/L,相对标准偏差(5μg/L,n=3)为1.1%。采用本方法测定了污水处理厂排水口的双酚A的自由溶解态浓度。  相似文献   

5.
Summary Solid-phase microextraction is a relatively recent extraction technique for sample preparation. It has been used successfully to analyse environmental pollutants in a variety of matrices such as soils, water and air. In this work, a simple and rapid method for the analysis of volatile organic and polar compounds from polluted groundwater samples by SPME coupled with gas chromatography (GC) is described. Different types of fibres were studied and the extraction process was optimised. The fibre that proved to be the best to analyse this kind of samples was CAR-PDMS. The method was validated by analysis of synthetic samples and comparison with headspace—GC. The optimised method was successfully applied to the analysis of ground-water samples.  相似文献   

6.
The use of a functionalized latex nanoparticle coating as a new sorbent phase for solid-phase microextraction (SPME) was examined. By means of electrostatic absorption onto ionized silanol groups, a fused-silica rod was coated with polymeric nanoparticles functionalized with quaternary ammonium groups. Optimum conditions for the preparation of the coated fibre are presented. The fibre was used for the extraction of a mixture of seven anions from water samples which are analysed by coupling the SPME fibre to an ion chromatographic system via a special interface. The results obtained proved the suitability of this novel coating as a new SPME fibre. A linear calibration for the target analytes was achieved over the concentration range from 5 μg L−1 to 5 mg L−1 (r2 > 0.988), while limits of detection for these ions were all below 3.7 μg L−1 (S/N = 3). The reproducibility of a single fibre (n = 4) under similar conditions was between 7 and 12%, while the fibre to fibre reproducibility (n = 5) was between 8.9 and 14%.  相似文献   

7.
Huang SD  Huang HI  Sung YH 《Talanta》2004,64(4):887-893
Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) for the determination of triazine is described. Carbowax/templated resin (CW/TPR, 50 μm), polydimethylsiloxane/divinylbenzene (PDMS/DVB, 60 μm), polydimethylsiloxane (PDMS, 100 μm), and polyacrylate (PA, 85 μm) fibers were evaluated for extraction of the triazines. CW/TPR and PDMS/DVB fibers were selected for further study. Several parameters of the extraction and desorption procedure were studied and optimized (such as types of fibers, desorption mode, desorption time, compositions of solvent for desorption, soaking periods and the flow rate during desorption period, extraction time, temperature, pH, and ionic strength of samples). Both CW/TPR and PDMS/DVB fibers are acceptable; a simple calibration-curve method based on simple aqueous standards can be used. The linearity of this method for analyzing standard solution has been investigated over the range 5-1000 ng mL−1 for both PDMS/DVB and CW/TPR fibers. All the correlation coefficients in the range 5-1000 ng mL−1 were better than 0.995 except Simazine and Atratone by CW/TPR fiber. The R.S.D.s range from 4.4% to 8.8 % (PDMS/DVB fiber) and from 2.4% to 7.2% (CW/TPR fiber). Method-detection limits (MDL) are in the range 1.2-2.6 and 2.8-3.4 ng mL−1 for the two fibers. These methods were applied to the determination of trazines in environmental water samples (lake water).  相似文献   

8.
An ionic liquid foam floatation coupled with ionic liquid dispersive liquid–liquid microextraction method was proposed for the extraction and concentration of 17‐α‐estradiol, 17‐β‐estradiol‐benzoate, and quinestrol in environmental water samples by high‐performance liquid chromatography with fluorescence detection. 1‐Hexyl‐3‐methylimidazolium tetrafluoroborate was applied as foaming agent in the foam flotation process and dispersive solvent in microextraction. The introduction of the ion‐pairing and salting‐out agent NH4PF6 was beneficial to the improvement of recoveries for the hydrophobic ionic liquid phase and analytes. Parameters of the proposed method including concentration of 1‐hexyl‐3‐methylimidazolium tetrafluoroborate, flow rate of carrier gas, floatation time, types and concentration of ionic liquids, salt concentration in samples, extraction time, and centrifugation time were evaluated. The recoveries were between 98 and 105% with relative standard deviations lower than 7% for lake water and well water samples. The isolation of the target compounds from the water was found to be efficient, and the enrichment factors ranged from 4445 to 4632. This developing method is free of volatile organic solvents compared with regular extraction. Based on the unique properties of ionic liquids, the application of foam floatation, and dispersive liquid–liquid microextraction was widened.  相似文献   

9.
A new generation polymeric ionic liquid (PIL), poly(1-4-vinylbenzyl)-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide (poly(VBHDIm+ NTf2)), was synthesized and is shown to exhibit impressive selectivity towards the extraction of 12 polycyclic aromatic hydrocarbons (PAHs) from aqueous samples when used as a sorbent coating in direct-immersion solid-phase microextraction (SPME) coupled to gas chromatography (GC). The PIL was imparted with aromatic character to enhance π–π interactions between the analytes and the sorbent coating. For comparison purposes, a PIL with similar structure but lacking the π–π interaction capability, poly(1-vinyl-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide) (poly(HDIm+ NTf2)), as well as a commercial polydimethylsiloxane (PDMS) sorbent coating were evaluated and exhibited much lower extraction efficiencies. Extraction parameters, including stir rate and extraction time, were studied and optimized. The detection limits of poly(VBHDIm+ NTf2), poly(HDIm+ NTf2), and PDMS coatings varied between 0.003–0.07 μg L−1, 0.02–0.6 μg L−1, and 0.1–6 μg L−1, respectively. The partition coefficients (log Kfs) of eight PAHs to the three studied fiber coatings were estimated using a static SPME approach. This study represents the first report of analyte partition coefficients to any PIL-based material.  相似文献   

10.
Metal organic frameworks (MOFs) are a new class of nanoporous materials that have many potential advantages over traditional nanoporous materials for several chemical technologies including gas adsorption, catalysis, membrane-based gas separation, sensing, and biomedical devices. Knowledge on the interaction of guest molecules with the MOF surface is required to design and develop these MOF-based processes. In this review, we examine the importance of identification of gas adsorption sites in MOFs using the current state-of-the-art in experiments and computational modeling. This review provides guidelines to design new MOFs with useful surface properties that exhibit desired performances, such as high gas storage capacity, and high gas selectivity.  相似文献   

11.
A novel solid-phase microextraction (SPME) method based on molecularly imprinted polymer (MIP) monolith as the sorbent for the selective extraction of thiamphenicol (TAP) in milk and honey was developed. The newly developed MIP monolith was produced using TAP as the template molecule, 4-vinylpyridine (4-VP) as the functional monomer. The TAP-MIP monolith synthesized in a micropipette tip could be connected with syringes in different sizes simply to perform SPME process without any other treatment. The derivated MIP monolith showed high selectivity and enrichment ability for TAP. A simple, rapid and sensitive method for the determination of TAP in milk and honey using polymer monolith microextraction (PMME) based on the MIP monolith combined with high-performance liquid chromatography-photodiodes array detector was developed. Several parameters affecting MIP monolith microextraction were investigated, including the flow rate, volume, pH and salt concentration of sample, the type and volume of washing solution, the type and flow rate of eluent. The recovery of this method for TAP was investigated and high recoveries of 92.9-99.3% from milk and honey were obtained with relative standard deviations less than 4.9%.  相似文献   

12.
Malik AK  Kaur V  Verma N 《Talanta》2006,68(3):842-849
This paper reviews the practical applications of solid phase microextraction-High performance liquid chromatography in the analysis of toxic metal species as these are important contaminants and are carcinogenic. Their determination in formulations, in feed and food, and in complex environmental matrices (e.g., waste water and industrial effluents) often requires analytical methods capable of high efficiency, unique selectivity, and high sensitivity. Solid phase microextraction (SPME) requires low solvent consumption and is quick in use. SPME is used for extraction and online desorption of analytes with the mobile phase of HPLC and subsequent detection by UV, ICP-MS or ESI-MS as detectors. Different SPME-HPLC methods are summarized in this article to demonstrate the usefulness of this technique for metallic species of As, Cr, Pb, Hg and Se.  相似文献   

13.
Applications of solid-phase microextraction (SPME) to the sampling and analysis of volatile organic compounds in indoor air are reviewed, including a summary of quantification methods, coatings, compounds, concentrations, sampling locations and times, and detection limits. Strategies for on-site and off-site sampling and analysis, advantages and challenges associated with SPME for air sampling are discussed.  相似文献   

14.
A simple, rapid and sensitive method for the determination of five estrogens, estrone, 17beta-estradiol, estriol, ethynyl estradiol, and diethylstilbestrol, was developed using a fully automated method consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS). These estrogens were separated within 8 min by HPLC using an XDB-C8 column and 0.01% ammonia/acetonitrile (60/40, v/v) at a flow rate of 0.2 mL/min. Electrospray ionization conditions in the negative ion mode were optimized for MS/MS detection of the estrogens. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 microL of sample using a Supel-Q PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME LC/MS/MS method, good linearity of the calibration curve (r > or = 0.9996) was obtained in the concentration range from 10 to 200 pg/mL for all compounds examined. The limits of detection (S/N= 3) of the five estrogens examined ranged from 2.7 to 11.7 pg/mL. The in-tube SPME method showed 34-90-fold higher sensitivity than the direct injection method (5 microL injection). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several surface water and wastewater samples were collected from the area around Asahi River, and estriol was detected at 35.7 pg/mL in the effluent of a sewage treatment plant. The recoveries of estrogens spiked into river waters were above 86%, except for estriol, and the relative standard deviations were below 0.9-8.8%.  相似文献   

15.
Four polymeric ionic liquids based on two different cations, poly(1‐vinyl‐3‐hexylimidazolium) and poly(1‐vinyl‐3‐hexadecylimidazolium), combined with two different anions, bis[(trifluoromethyl)sulfonyl]imide (NTf) and chloride (Cl?), were combined in various weight percentages and used as sorbent coatings for solid‐phase microextraction gas chromatography (SPME‐GC). The selectivity of the fiber coatings for 12 test analytes was examined. The extraction efficiency of n‐alcohols increased with an increase in the weight percentage of chloride ion in the sorbent coating. The ability to tune the interactions between the coating material and the analytes was exploited and resulted in distinct changes in the limits of detection for hydrogen‐bonding analytes with varying chloride ion content in the sorbent coating.  相似文献   

16.
The extraction, identification, and quantification of wine aroma compounds are preliminary steps required for further investigation of wine quality, i.e. determination of the varieties of grapes used, the production process, and the origin and age of the wine. This paper deals with the optimization of solid-phase microextraction for the determination of compounds which produce wine bouquet. Optimum operating conditions have been determined to obtain high reproducibility at low cost and with low time-consumption. Several factors influencing the equilibrium of the aroma compounds between the sample and the fiber must be taken into account, including length of contact time between the two phases involved, speed of agitation of the sample, the matrix in which the process takes place, and, furthermore, the place, duration, and temperature of desorption in the injector of the chromatograph.  相似文献   

17.
A solid-phase microextraction (SPME) procedure using two commercial fibers coupled with high-performance liquid chromatography (HPLC) is presented for the extraction and determination of organochlorine pesticides in water samples. We have evaluated the extraction efficiency of this kind of compound using two different fibers: 60-μm polydimethylsiloxane–divinylbenzene (PDMS-DVB) and Carbowax/TPR-100 (CW/TPR). Parameters involved in the extraction and desorption procedures (e.g. extraction time, ionic strength, extraction temperature, desorption and soaking time) were studied and optimized to achieve the maximum efficiency. Results indicate that both PDMS-DVB and CW/TPR fibers are suitable for the extraction of this type of compound, and a simple calibration curve method based on simple aqueous standards can be used. All the correlation coefficients were better than 0.9950, and the RSDs ranged from 7% to 13% for 60-μm PDMS-DVB fiber and from 3% to 10% for CW/TPR fiber. Optimized procedures were applied to the determination of a mixture of six organochlorine pesticides in environmental liquid samples (sea, sewage and ground waters), employing HPLC with UV-diode array detector.  相似文献   

18.
A polymeric ionic liquid (PIL) poly(1-vinyl-3-hexylimidazolium chloride) (poly(ViHIm+Cl)) was designed as a coating material for solid phase microextraction (SPME) to extract polar compounds including volatile fatty acids (VFAs) and alcohols. The extracted analytes were analyzed by using gas chromatography (GC) coupled with flame ionization detection (FID). Extraction parameters of the HS–SPME–GC–FID method, such as ionic strength, extraction temperature, pH and extraction time were optimized. Calibration studies were carried out under the optimized conditions to further evaluate the performance of the PIL-based SPME coating. For comparison purposes, the PIL poly(1-vinyl-3-hexylimidazolium bis[(trifluoromethyl)sulfonyl]imide) (poly(ViHIm+NTf2)) was also used as the SPME coating to extract the same analytes. The results showed that the poly(ViHIm+Cl) PIL coating had higher selectivity towards more polar analytes due to the presence of the Cl anion which provides higher hydrogen bond basicity than the NTf2 anion. The limits of detection (LODs) determined by the designed poly(ViHIm+Cl) PIL coating ranged from 0.02 μg L−1 for octanoic acid and decanoic acid and 7.5 μg L−1 for 2-nitrophenol, with precision values (as relative standard deviation) lower than 14%. The observed performance of the poly(ViHIm+Cl) PIL coating was comparable to previously reported work in which commercial or novel materials were used as SPME coatings. The selectivity of the developed PIL coatings was also evaluated using heptane as the matrix solvent. This work demonstrates that the selectivity of PIL-based SPME coatings can be simply tuned by incorporating different counteranions to the sorbent coating.  相似文献   

19.
Zhou YY  Wang SW  Kim KN  Li JH  Yan XP 《Talanta》2006,69(4):970-975
Dichlorodiphenyltrichloroethane (DDT) and its metabolites are a typical kind of persistent organic pollutants (POPs). Development of a simple, cost-effective and sensitive methodology to monitor DDTs concentrations in water environment is of particular significance for understanding the fate and behavior of these pollutants. In this paper, a method on the basis of solid-phase extraction (SPE) using expanded graphite (EG) as sorbent coupled on-line with high performance liquid chromatography (HPLC) was developed for the determination of trace levels of p,p′-DDD (2,2-bis(4-chlorophenyl)-1,1-dichloroethane), p,p′-DDT, o,p′-DDT and p,p′-DDE (2,2-bis(4-chlorophenyl)-1,1-dichloroethene) in water. The analytes in water were preconcentrated onto the SPE column packed with expanded graphite, and subsequently eluted with methanol-water (90:10) mixed solvent. HPLC with a photodiode array detector was used for their separation and detection. The developed on-line solid-phase extraction protocol for HPLC permits the current HPLC separation and the next preconcentration proceeded in parallel, and thus allows one determination within 8 min. The precision (R.S.D.) for 10 replicate injections of a mixture of 1 μg l−1 of each analyte was 3.2-6.2% for the peak area measurement. The detection limits (S/N = 3) for preconcentrating 50 ml of sample solution ranged from 10 to 25 ng l−1 at a sample throughput of 7.5 samples h−1. The enhancement factors were about 700. The method was applied to the determination of trace p,p′-DDD, p,p′-DDT, o,p′-DDT and p,p′-DDE in local lake, river and tap water samples.  相似文献   

20.
Ultrasound-assisted emulsification microextraction based on the solidification of floating organic droplet combined with high-performance liquid chromatography-ultra violet (HPLC-UV) detection was applied for the extraction and determination of fluoxetine, citalopram, and venlafaxine as antidepressants drugs in biological samples. In total, 30 μL of undecanol was injected slowly into a glass-centrifuge tube containing 5 mL alkaline sample solution that was located inside the ultrasonic water bath. The formed emulsion was centrifuged and the fine droplets of solvent were floated at the top of the test tube. The test tube was then cooled in an ice bath and the solidified solvent transferred into a conical vial; it melted quickly at room temperature. Then the analysis of the extracts was carried out by high-performance liquid chromatography. Under optimal conditions, the preconcentration factors were between 174 and 316. Detection limits (LODs) of 3 μg/L were obtained and the calibration graphs were linear within the range of 10-1000 μg/L. Finally, the feasibility of the proposed method was successfully confirmed by extraction and determination of the antidepressant drugs in human urine and plasma samples in the range of microgram per liter and suitable results were obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号