首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A high-performance liquid chromatography (LC)–tandem mass spectrometry (MS/MS) method has been developed and validated for the determination of 19 drugs of abuse and metabolites and used in whole blood. The following compounds were included: amphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethamphetamine, methamphetamine, cocaine, benzoylecgonine, morphine, 6-acetylmorphine, codeine, methadone, buprenorphine, norbuprenorphine, ketobemidone, tramadol, O-desmethyltramadol, zaleplone, zolpidem, and zopiclone. The sample pretreatment consisted of solid-phase extraction using mixed-mode columns (Isolute Confirm HCX). Deuterated analogues were used as internal standards for all analytes, except for ketobemidone and O-desmethyltramadol. The analytes were separated by a methanol/ammonium formate gradient using high-performance LC (Agilent HPLC 1100) with a 3 mm × 100 mm Varian Pursuit 3 C18 column, 3-μm particle size, and were quantified by MS/MS (Waters Quattro micro tandem quadrupole mass spectrometer) using multiple reaction monitoring in positive mode. Two transitions were used for all analytes, except for tramadol and O-desmethyltramadol. The run time of the method was 35 min including the equilibration time. For all analytes, responses were linear over the range investigated, with R 2 > 0.99. One-point calibration was found to be adequate by validation, thereby saving analysis of multiple calibrators. The limits of quantification (LOQs) for the analytes ranged from 0.0005 to 0.01 mg/kg. Absolute recoveries of the analytes were from 34 to 97%, except for zaleplone (6%). Both the interday precision and the intraday precision were less than 15% (20% at the LOQ) for all analytes, except buprenorphine, norburprenorphine, and zaleplone (less than 18%). Accuracy (bias) was within ±15% (±20% at the LOQ) for all analytes, except MDMA and O-desmethyltramadol (within ±19%). No ion suppression or enhancement was seen nor was suppression from coeluted analytes seen. Matrix effects were found to be less than 23% for all analytes, except zopiclone (64%). High-concentration and low-concentration quality control samples gave acceptable values, and the method has been tried in international proficiency test schemes with good results. The present LC-MS/MS method provides a simple, specific, and sensitive solution for the quantification of some of the most frequent drugs of abuse and their metabolites in whole blood. The quantification by LC-MS/MS was successfully applied to 412 forensic cases from October 2008 to mid February 2009, where 267 cases were related to zero-tolerance traffic legislation.  相似文献   

2.
The first method for quantifying cannabinoids and cannabinoid glucuronides in whole blood by liquid chromatography–tandem mass spectrometry (LC–MS/MS) was developed and validated. Solid-phase extraction followed protein precipitation with acetonitrile. High-performance liquid chromatography separation was achieved in 16 min via gradient elution. Electrospray ionization was utilized for cannabinoid detection; both positive (Δ9-tetrahydrocannabinol [THC] and cannabinol [CBN]) and negative (11-hydroxy-THC [11-OH-THC], 11-nor-9-carboxy-THC [THCCOOH], cannabidiol [CBD], THC-glucuronide, and THCCOOH-glucuronide) polarity were employed with multiple reaction monitoring. Calibration by linear regression analysis utilized deuterium-labeled internal standards and a 1/x 2 weighting factor, yielding R 2 values >0.997 for all analytes. Linearity ranged from 0.5 to 50 μg/L (THC-glucuronide), 1.0–100 μg/L (THC, 11-OH-THC, THCCOOH, CBD, and CBN), and 5.0–250 μg/L (THCCOOH-glucuronide). Imprecision was <10.5% CV, recovery was >50.5%, and bias within ±13.1% of target for all analytes at three concentrations across the linear range. No carryover and endogenous or exogenous interferences were observed. This new analytical method should be useful for quantifying cannabinoids in whole blood and further investigating cannabinoid glucuronides as markers of recent cannabis intake.  相似文献   

3.
4.
Quantification of chromium in whole blood has been performed by ICP–quadrupole MS. The spectrometer was equipped with a dynamic reaction cell (DRC) with ammonia as reaction gas. The rejection parameter q (RPq) of the DRC and the flow rate of ammonia (NH3) were optimized and set at 0.7 and 0.6 mL min−1, respectively. Blood was diluted 1:51 (v/v) with an aqueous solution containing 0.1 mg L−1 NH4OH, 0.1 g L−1 EDTA, 5 mg L−1 n-butanol, and 0.1‰ Triton X100. Non-spectral matrix effects observed when using the DRC were confirmed by use of vanadium. External calibration with blank and standard solutions prepared in purified water led to biased results for quality control samples. Standard addition calibration was therefore used and its validity verified. By comparing the slopes and calculating residues, it was proved that the plot obtained with standard additions and the plot obtained from blood samples of different concentrations were aligned down to 0.05 μg L−1 after dilution.  相似文献   

5.
A novel method based on the coupling of membrane-supported headspace single-drop microextraction with gas chromatography?mass spectrometry (GC–MS) is developed for the determination of chlorobenzenes in water samples. For the determination of five chlorobenzenes, a 15 μL toluene microdrop was placed inside the plastic membrane and exposed for 10 min for headspace extraction while stirring at 1000 rpm. The microdrop was then picked up by a microsyringe and directly injected into the injector block of the GC–MS instrument. Under the optimized operation conditions, the calculated calibration curves gave a high level of linearity for all targets with correlation coefficients range from 0.9945 to 0.9987. The limits of detection range from 0.01 to 0.05 μg/L and the RSDs for most of chlorobenzenes were below 7%. The method is simple, sensitive, and stable for single drop microextraction. Its applicability is demonstrated by the determination of chlorobenzenes in tap water samples.  相似文献   

6.
Forensic investigations involving acute or lethal intoxication, drug-facilitated sexual assault, driving or workplace impairment frequently require the analysis of fresh or postmortem blood samples to check out a wide variety of pharmaceutical and illicit drugs, even after single-dose consumption. A sensitive and selective ultrahigh-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) screening method was developed for fast screening of 88 psychoactive drugs and metabolites in blood samples, including the ones most frequently involved in acute intoxications and forensic investigations in Italy. The new method allows short sample processing and analysis time (the whole procedure can be accomplished in less than 30 min) together with the simultaneous monitoring of a large number of pharmaceutical substances. These features represent crucial factors in the approach of acute intoxications, when the patient requires urgent and appropriate therapy. Blood sample treatment was limited to protein precipitation. Two UHPLC–MS/MS runs in positive and negative electrospray ionization modes were performed. The data were acquired at unit mass resolution in the selected reaction monitoring mode. According to international guidelines, linearity range, precision, trueness, detection and quantification limits, recovery, selectivity, specificity, carryover, and matrix effect phenomena were determined. Despite the limited sample purification and the inherent decreased chance of eliminating any potential interference, the present multiresidue screening method proved extremely effective and sensitive, allowing the detection of all tested drugs, even those belonging to structurally different classes of substances. Moreover, the developed method is easily susceptible to further expansion to encompass more drugs, either new or those becoming important for criminal investigation. This protocol was also applied to the analysis of authentic blood samples collected from victims of various crimes in routine casework, whose relevance in forensic investigations is presented in five cases.  相似文献   

7.
Ciguatera fish poisoning (CFP) is a food intoxication caused by exposure to ciguatoxins (CTXs) in coral reef fish. Rapid analytical methods have been developed recently to quantify Pacific-CTX-1 (P-CTX-1) in fish muscle, but it is destructive and can cause harm to valuable live coral reef fish. Also fish muscle extract was complex making CTX quantification challenging. Not only P-CTX-1, but also P-CTX-2 and P-CTX-3 could be present in fish, contributing to ciguatoxicity. Therefore, an analytical method for simultaneous quantification of P-CTX-1, P-CTX-2, and P-CTX-3 in whole blood of marketed coral reef fish using sonication, solid-phase extraction (SPE), and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed. The optimized method gave acceptable recoveries of P-CTXs (74–103 %) in fish blood. Matrix effects (6–26 %) in blood extracts were found to be significantly reduced compared with those in muscle extracts (suppressed by 34–75 % as reported in other studies), thereby minimizing potential for false negative results. The target P-CTXs were detectable in whole blood from four coral reef fish species collected in a CFP-endemic region. Similar trends in total P-CTX levels and patterns of P-CTX composition profiles in blood and muscle of these fish were observed, suggesting a relationship between blood and muscle levels of P-CTXs. This optimized method provides an essential tool for studies of P-CTX pharmacokinetics and pharmacodynamics in fish, which are needed for establishing the use of fish blood as a reliable sample for the assessment and control of CFP.
Figure
Chromatograph of P-CTXs in whole blood of wild-caught moray eel  相似文献   

8.
Determination of phosphorus in small amounts of protein samples by ICP–MS   总被引:3,自引:0,他引:3  
Inductively coupled plasma mass spectrometry (ICP-MS) is used for phosphorus determination in protein samples. A small amount of solid protein sample (down to 1 micro g) or digest (1-10 micro L) protein solution was denatured in nitric acid and hydrogen peroxide by closed-microvessel microwave digestion. Phosphorus determination was performed with an optimized analytical method using a double-focusing sector field inductively coupled plasma mass spectrometer (ICP-SFMS) and quadrupole-based ICP-MS (ICP-QMS). For quality control of phosphorus determination a certified reference material (CRM), single cell proteins (BCR 273) with a high phosphorus content of 26.8+/-0.4 mg g(-1), was analyzed. For studies on phosphorus determination in proteins while reducing the sample amount as low as possible the homogeneity of CRM BCR 273 was investigated. Relative standard deviation and measurement accuracy in ICP-QMS was within 2%, 3.5%, 11% and 12% when using CRM BCR 273 sample weights of 40 mg, 5 mg, 1 mg and 0.3 mg, respectively. The lowest possible sample weight for an accurate phosphorus analysis in protein samples by ICP-MS is discussed. The analytical method developed was applied for the analysis of homogeneous protein samples in very low amounts [1-100 micro g of solid protein sample, e.g. beta-casein or down to 1 micro L of protein or digest in solution (e.g., tau protein)]. A further reduction of the diluted protein solution volume was achieved by the application of flow injection in ICP-SFMS, which is discussed with reference to real protein digests after protein separation using 2D gel electrophoresis.The detection limits for phosphorus in biological samples were determined by ICP-SFMS down to the ng g(-1) level. The present work discusses the figure of merit for the determination of phosphorus in a small amount of protein sample with ICP-SFMS in comparison to ICP-QMS.  相似文献   

9.
A rapid, sensitive, and environmental-friendly multi-residue method has been developed for the simultaneous determination of seven neonicotinoid insecticides (dinotefuran, nitenpyram, thiamethoxam, imidacloprid, clothianidin, acetamiprid, and thiacloprid) residues in eel samples. Subcritical water extraction was investigated as a novel and alternative technology for the extraction of neonicotinoids from eel matrices and the results were compared with the conventional ultrasonic and shaking extraction. The target compounds were identified and quantitatively determined by ultra-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC–MS/MS) operated in multiple reaction monitoring mode. Under the current optimized chromatographic conditions, each LC run was completed in 5 min. Average recoveries of the seven analytes from fortified samples ranged between 84.6% and 102.0%, with relative standard deviations (RSD) lower than 10.8%. The limits of detection (LODs) and quantification (LOQs) for neonicotinoids were in the ranges of 0.12–0.36 μg kg−1 and 0.42–1.12 μg kg−1, respectively. The proposed method is fast, sensitive, easy to perform, water-based thus more environmentally acceptable, making it applicable for high-throughput monitoring of insecticides residues in aquatic products.  相似文献   

10.
A sensitive and accurate method is described for the determination of ultra-trace nickel in environmental samples with in-situ trapping of volatile species in iridium-palladium coated graphite furnace atomic absorption spectrometry. The effects of the conditions for the generation and collection of volatile nickel species, such as medium acidity, potassium borohydride concentration, enhancement reagent concentration, reaction temperature, as well as graphite tube coating, carrier gas flow rate and trapping time were investigated. Phenanthroline was selected as the enhancement reagent due to its good enhancing effect, and iridium–palladium coating was used for the in-situ trapping of volatile nickel species at 300°C. Under the optimal conditions, the calibration curve was linear from 0.21 up to 30.0 ng mL?1 with correlation coefficient of 0.9991, the detection limit (S/N = 3) was 0.21 ng mL?1 for 4 mL sample volumes and the relative standard deviation for 11 determinations of Ni at 10 ng mL?1 was 3.5%. The results found by the proposed methods are accordant with the certified values of water, soil and tea certified reference materials. The proposed methods have been applied for the determination of ultra-trace Ni in tap, river and wastewater, as well as rice and soil samples, with recoveries ranging from 97.3 to 100.5%.  相似文献   

11.
A method using microextraction by packed sorbent (MEPS) and gas chromatography–tandem mass spectrometry (GC-MS/MS) is described for the determination of seven antipsychotic drugs in human plasma. The studied compounds were chlorpromazine (CPZ), haloperidol (HAL), cyamemazine, quetiapine, clozapine, olanzapine (OLZ), and levomepromazine; promazine, protriptyline, and deuterated CPZ were used as internal standards. The validation parameters included selectivity, linearity and limits of detection and quantitation, intra- and interday precision and trueness, recovery, and stability and were studied according to internationally accepted guidelines. The method was found to be linear between the lower limit of quantitation and 1000 ng/mL, except for OLZ and HAL (200 ng/mL), with determination coefficients higher than 0.99 for all analytes, and extraction efficiencies ranged from 62 to 92 %. Intra- and interday precision ranged from 0.24 to 10.67 %, while trueness was within a ±15 % interval from the nominal concentration for all analytes at all studied levels. MEPS has shown to be a rapid procedure for the determination of the selected antipsychotic drugs in human plasma, allowing reducing the handling time and the costs of analysis. Furthermore, GC-MS/MS has demonstrated to be a powerful tool for the simultaneous quantitation of the studied compounds, enabling obtaining adequate selectivity and sensitivity using a sample volume of as low as 0.25 mL.  相似文献   

12.
Methamphetamine and amphetamine were extracted from human whole blood samples using pipette tip solid-phase extraction (SPE) with MonoTip C18 tips, on which C18-bonded monolithic silica gel was fixed. Human whole blood (0.1 mL) containing methamphetamine and amphetamine, with N-methylbenzylamine as an internal standard, was mixed with 0.4 mL of distilled water and 50 μL of 5 M sodium hydroxide solution. After centrifugation, the supernatant was extracted to the C18 phase of the tip (pipette tip volume, 200 μL) by 25 repeated aspirating/dispensing cycles using a manual micropipettor. Analytes retained in the C18 phase were eluted with methanol by five repeated aspirating/dispensing cycles. After derivatization with trifluoroacetic anhydride, analytes were measured by gas chromatography – mass spectrometry with selected ion monitoring in the positive-ion electron impact mode. Recoveries of methamphetamine and amphetamine spiked into whole blood were more than 87.6 and 81.7%, respectively. Regression equations for methamphetamine and amphetamine showed excellent linearity in the range of 0.5–100 ng/0.1 mL. The limits of detection for methamphetamine and amphetamine were 0.15 and 0.11 ng/0.1 mL, respectively. Intra- and interday coefficients of variation for both stimulants were not greater than 9.6 and 13.8%, respectively. The determination of methamphetamine and amphetamine in autopsy whole blood samples is presented, and was shown to validate the present methodology.  相似文献   

13.
Evodiamine and rutecarpine are two kinds of indole alkaloids contained in the fruit of Evodiae fructus, which have been shown to exhibit various bioactivities in humans. A liquid chromatography–tandem mass spectrometric method (LC–MS/MS) was developed for the determination of evodiamine and rutecarpine in human serum. The serum was extracted by solid-phase extraction (SPE) and analyzed using a C18 column and a mobile phase consisting of methanol–water (85:15) solution containing 5 mmol/L ammonium formate at a flow rate of 0.5 mL/min. The mass spectrometer was operated in positive mode, employing the extracted ion chromatogram (EIC) for detection and quantitation of evodiamine (m/z 288) and rutecarpine (m/z 304). Good linear relationships between the peak area and the concentration were obtained in the ranges of 5.2–1040 ng/mL and 10.2–1020 ng/mL, with correlation coefficients (r) of 0.999 and 0.998, for evodiamine and rutecarpine, respectively. The repeatabilities (RSD, n=6) of quantitation for evodiamine and rutecarpine were 2.18–4.00% and 2.99–5.67%, respectively, and the recovery ranged from 90.5% to 98.1%. A comparative study of the different ionization and quantitation modes, including ESI–MS, ESI–MS/MS, APCI–MS and APCI–MS/MS, was also accomplished. The MS/MS fragmentation mechanism of the base peak ([M+H]+, m/z 304) of evodiamine was investigated in order to identify the analytes in more complicated body fluid samples.   相似文献   

14.
Ecgonine is suggested to be a promising marker of cocaine (COC) ingestion. A combined mass spectrometry (MS) and tandem MS (MS/MS) method was developed to simultaneously determine ecgonine and seven other metabolites of cocaine in human urine and whole blood with ultra-high-pressure liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. The compounds were extracted from as little as 100 μL of sample by solid-phase extraction with a 96-well μElution solid-phase extraction plate. The protonated molecules or fragment ions at accurate mass acquired in MS mode were used to quantify specific analytes, following by dedicated MS/MS identification. The assay was linear in the range from 5 to 50-100 ng/mL for urine samples, except for ecgonine methyl ester (10-200 ng/mL) and ecgonine (40-400 ng/mL), and was linear from 1-2 to 50 ng/mL for whole blood samples, except for ecgonine methyl ester (20-1,000 ng/mL) and ecgonine (40-2,000 ng/mL). The correlation coefficients were all greater than 0.99. The limits of detection ranged from 0.2 to 16 ng/mL, and the lower limits of quantification ranged from 1 to 40 ng/mL. The repeatability and intermediate precision were 18.1 % or less. The accuracy was in the range from 80.0 to 122.9 %, process efficiencies were in the range from 8.6 to 177.4 %, matrix effects were in the range from 28.7 to 171.0 %, and extraction recoveries were in the range from 41.0 to 114.3 %, except for ecgonine (12.8 % and 9.3 % at low and high concentrations, respectively). This method was highly sensitive in comparison with previously published methods. The validated method was successfully applied to the analysis of real samples derived from forensic cases, and the results verified that, on the basis of data from four positive samples, ecgonine is a promising marker of cocaine ingestion.
Figure
Procedure for the determination of ecgonine and seven other cocaine metabolites in human urine and whole blood using a combined mass spectrometry and tandem MS method aIer the solid‐phase extraction of the anaytes  相似文献   

15.
An efficient method for analyzing illegal and medicinal drugs in whole blood using fully automated sample preparation and short ultra-high-performance liquid chromatography–tandem mass spectrometry (MS/MS) run time is presented. A selection of 31 drugs, including amphetamines, cocaine, opioids, and benzodiazepines, was used. In order to increase the efficiency of routine analysis, a robotic system based on automated liquid handling and capable of handling all unit operation for sample preparation was built on a Freedom Evo 200 platform with several add-ons from Tecan and third-party vendors. Solid-phase extraction was performed using Strata X-C plates. Extraction time for 96 samples was less than 3 h. Chromatography was performed using an ACQUITY UPLC system (Waters Corporation, Milford, USA). Analytes were separated on a 100 mm?×?2.1 mm, 1.7 μm Acquity UPLC CSH C18 column using a 6.5 min 0.1 % ammonia (25 %) in water/0.1 % ammonia (25 %) in methanol gradient and quantified by MS/MS (Waters Quattro Premier XE) in multiple-reaction monitoring mode. Full validation, including linearity, precision and trueness, matrix effect, ion suppression/enhancement of co-eluting analytes, recovery, and specificity, was performed. The method was employed successfully in the laboratory and used for routine analysis of forensic material. In combination with tetrahydrocannabinol analysis, the method covered 96 % of cases involving driving under the influence of drugs. The manual labor involved in preparing blood samples, solvents, etc., was reduced to a half an hour per batch. The automated sample preparation setup also minimized human exposure to hazardous materials, provided highly improved ergonomics, and eliminated manual pipetting.
Figure
Robotic setup for fully automated solid-phase extraction of whole blood  相似文献   

16.
A new, fast and efficient multiple reaction monitoring (MRM) high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method for the determination of cyclopiazonic acid (CPA) in mixed feed, wheat, peanuts and rice is presented. The analytical methodology involves sample extraction with an alkaline methanol–water mixture, defatting with hexane and quantification using HPLC–MS/MS without further treatment of sample extracts. Reversed-phase liquid chromatography using a C18 stationary phase coupled to negative mode electrospray triple quadrupole tandem mass spectrometry was applied. The limit of detection was 5 μg/kg while the limit of quantification was 20 μg/kg in the matrices investigated. The detector response was found to be linear over the range 25–250 μg/kg in feed and 25–500 μg/kg in wheat, peanuts and rice. The mean overall recoveries (n = 18) of CPA varied from 79% to 114% in the range of concentrations studied over a period of 4 months. Mean recoveries (n = 3 or 6) of CPA in wheat, peanuts and rice varied from 70% to 111%, 77% to 116% and 69% to 92%, respectively. The method was successfully applied to the analysis of feed and rice samples artificially infected with the fungal strain Penicillium commune, where the toxin was found at different levels.  相似文献   

17.
Liu W  Kong Y  Zu Y  Fu Y  Luo M  Zhang L  Li J 《Journal of chromatography. A》2010,1217(28):4723-4731
A novel method using liquid chromatography coupled to electrospray ionization mass spectrometry (LC-ESI-MS) has been optimized and established for the qualitative and quantitative analysis of ten active phenolic compounds originating from the pigeon pea leaves and a medicinal product thereof (Tongluo Shenggu capsules). In the present study, the chromatographic separation was achieved by means of a HiQ Sil C18V reversed-phase column with a mobile phase consisting of methanol and 0.1% formic acid aqueous solution. Low-energy collision-induced dissociation tandem mass spectrometry (CID-MS/MS) using the selected reaction monitoring (SRM) analysis was employed for the detection of ten analytes which included six flavonoids, two isoflavonoids and two stilbenes. All calibration curves showed excellent coefficients of determination (r(2) ≥ 0.9937) within the range of tested concentrations. The intra- and inter-day variations were below 5.36% in terms of relative standard deviation (RSD). The recoveries were 95.08-104.98% with RSDs of 2.06-4.26% for spiked samples of pigeon pea leaves. The method developed was a rapid, efficient and accurate LC-MS/MS method for the detection of phenolic compounds, which can be applied for quality control of pigeon pea leaves and related medicinal products.  相似文献   

18.
Using the bottom-up approach and liquid chromatography (LC) in combination with mass spectrometry, the primary structure and sequence microheterogeneity of a plaque-specific anti-β-amyloid (1–17) monoclonal antibody (clone 6E10) was characterized. This study describes the extent of structural information directly attainable by a high-performance LC–tandem mass spectrometric method in combination with both protein database searching and de novo sequence determination. Using trypsin and chymotrypsin for enzymatic digestion, 95% sequence coverage of the light chain and 82% sequence coverage of the heavy chain of the 6E10 antibody were obtained. The primary structure determination of a large number of peptides from the antibody variable regions was obtained through de novo interpretation of the data. In addition, N-terminal truncations of the heavy chain were identified as well as low levels of pyroglutamic acid formation. Surprisingly, pronounced sequence microheterogeneities were determined for the CDR 2 region of the light chain, indicating that changes at the protein level derived from somatic hypermutation of the Ig VL genes in mature B-cells might contribute to unexpected structural diversity. Furthermore, the major glycoforms at the conserved heavy chain N-glycosylation site, Asn-292, were determined to be core-fucosylated, biantennary, complex-type structures containing zero to two galactose residues. Figure Primary structure and sequence microheterogeneities of a β-amyloid plaque-specific monoclonal antibody were identified by high-performance LC-tandem-mass spectrometry. Sequence heterogeneities of the light chain CDR2 reveal unexpected diversity from VL-gene hypermutations. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

19.
A gas chromatography–tandem mass spectrometric (GC-MS/MS) method has been developed for the determination of carbofuran (2,3-dihydro-2,2-dimethylbenzofuran-7-yl methylcarbamate), carbaryl (1-naphthyl-N-methylcarbamate) and their main metabolites in human blood plasma. Optimization of the isolation of the compounds from plasma matrix included the precipitation, denaturation and digestion of plasma proteins. Derivatization was achieved by the use of trifluoroacetic acid anhydride and was optimized for temperature, time and volume of derivatization agent. In the proposed method, a mild precipitation technique was applied using β-mercaptoethanol and ascorbic acid in combination with solid-phase extraction technique using Oasis HLB (Hydrophobic Lipophilic Balance) cartridges for further clean up of samples. Carbamate linkage was not hydrolyzed to its phenol product, but both carbamate phenol and ketones were transformed into trifluoroacetyl derivatives in order to become volatile compounds and were determined using tandem mass spectrometry. The linearity of the method was shown for nine concentrations in the range of 0.50–250 ng mL−1 in fortified plasma aliquots. Limits of detection (LODs) for all compounds ranged from 0.015–0.151 ng mL−1. Inter-day and intra-day assays (RSD) for all compounds, at three concentration levels of 2.5, 25 and 100 ng mL−1 (n=3) in fortified plasma samples were less than 18%. Accuracy (%E r) was calculated at three concentration levels, 8, 80 and 160 ng mL−1 (n=3), and ranged from −12.0 to 15.0%. Matrix effect was evaluated so mean recoveries were calculated for all compounds and ranged from 81–107%. Specificity for the use of this method to biological monitoring studies was achieved including four main metabolites of CF, 1-naphthol and 2-naphthol from the naphthalene metabolism pathways, and both the parent compound of carbofuran and carbaryl. The proposed method was applied to plasma samples of pesticide users.  相似文献   

20.
A multiresidue method using gas chromatography coupled to ion trap tandem mass spectrometry (GC–ITD–MS/MS) associated with solid phase microextraction (SPME) was developed for the analysis of 20 pesticides commonly used in the Alsace region in rainwater samples. Since the pesticides were expected to be present at very low concentrations and in complex matrices, the analytical method used was both highly selective and sensitive. Therefore, fibers coated with polyacrylate (PA), polydimethylsiloxane (PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB) were tested, and the parameters affecting the precision and accuracy of the SPME method were investigated and optimized. These parameters include the type of fiber, the adsorption time, the effect of salt, and the extraction temperature. The PDMS fiber was the most polyvalent for the extractions of the different pesticides studied. Detection limits of between 5 and 500 ng L−1, depending on the compounds under study (except for those which could not be analyzed: captan and mevinphos), were obtained with this analytical procedure. This method was applied to the analysis of rainwater samples collected simultaneously on a weekly basis at one rural and one urban site between March 2002 and July 2003. While some of the 20 pesticides analyzed were constantly detected (such as lindane and atrazine), a strong temporal variability was observed for some of the others (including alachlor, metolachlor, atrazine).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号